• Title/Summary/Keyword: Length Dimension

Search Result 665, Processing Time 0.023 seconds

Application of Simulated Three Dimensional CT Image in Orthognathic Surgery (악교정 수술에서 모의 조종된 3차원 전산화 단층촬영상의 응용)

  • Kim Hyung-Don;Yoo Sun-Kook;Lee Kyoung-Sang;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.2
    • /
    • pp.363-385
    • /
    • 1998
  • In orthodontics and orthognathic surgery. cephalogram has been routine practice in diagnosis and treatment evaluation of craniofacial deformity. But its inherent distortion of actual length and angles during projecting three dimensional object to two dimensional plane might cause errors in quantitative analysis of shape and size. Therefore, it is desirable that three dimensional object is diagnosed and evaluated three dimensionally and three dimensional CT image is best for three dimensional analysis. Development of clinic necessitates evaluation of result of treatment and comparison before and after surgery. It is desirable that patient that was diagnosed and planned by three dimensional computed tomography before surgery is evaluated by three dimensional computed tomography after surgery. too. But Because there is no standardized normal values in three dimension now and three dimensional Computed Tomography needs expensive equipments and because of its expenses and amount of exposure to radiation. limitations still remain to be solved in its application to routine practice. If postoperative three dimensional image is constructed by pre and postoperative lateral and postero-anterior cephalograms and preoperative three dimensional computed tomogram. pre and postoperative image will be compared and evaluated three dimensionally without three dimensional computed tomography after surgery and that will contribute to standardize normal values in three dimension. This study introduced new method that computer-simulated three dimensional image was constructed by preoperative three dimensional computed tomogram and pre and postoperative lateral and postero-anterior cephalograms. and for validation of new method. in four cases of dry skull that position of mandible was displaced and four patients of orthognathic surgery. computer-simulated three dimensional image and actual postoperative three dimensional image were compared. The results were as follows. 1. In four cases of dry skull that position of mandible was displaced. range of displacement between computer-simulated three dimensional images and actual postoperative three dimensional images in co-ordinates values was from -1.8 mm to 1.8 mm and 94% in displacement of all co-ordinates values was from -1.0 mm to 1.0 mm and no significant difference between computer-simulated three dimensional images and actual postoperative three dimensional images was noticed(p>0.05). 2. In four cases of orthognathic surgery patients, range of displacement between computer­simulated three dimensional images and actual postoperative three dimensional images in coordinates values was from -6.7 mm to 7.7 mm and 90% in displacement of all co-ordinates values was from -4.0 to 4.0 mm and no significant difference between computer-simulated three dimensional images and actual postoperative three dimensional images was noticed(p>0.05). Conclusively. computer-simulated three dimensional image was constructed by preoperative three dimensional computed tomogram and pre and postoperative lateral and postero-anterior cephalograms. Therefore. potentiality that can construct postoperative three dimensional image without three dimensional computed tomography after surgery was presented.

  • PDF

Three Dimensional Analysis of Primary Maxillary Central and Lateral Anterior Zirconia Crown (상악 유절치 지르코니아 전장관 수복을 위한 3차원 분석)

  • Lee, Jungmin;Lee, Hyoseol;Nam, Okhyung;Kim, Misun;Choi, Sungchul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.43 no.2
    • /
    • pp.176-186
    • /
    • 2016
  • This study was performed to compare the shape and dimension of anterior zirconia crowns to other pediatric crowns using a three-dimensional scanner to investigate adequate amount of tooth preparation. Primary central and lateral anterior zirconia crowns, stainless steel crowns and celluloid strip crowns were scanned by a three-dimensional scanner. Outer and inner surfaces of zirconia and stainless steel crowns, and outer surface of celluloid strip crowns were analyzed. In outer scanned images, all sizes of central and lateral size 1 zirconia crown had the largest labiolingual diameter among the three crowns. In inner scanned images, zirconia crown's mesiodistal diameter was 0.7-1.0 mm smaller and crown length was approximately 1 mm shorter than those of stainless steel crowns. Zirconia crown's labiolingual diameter was larger in central crowns whereas it was smaller in lateral crowns than that of stainless steel crowns. Recommended preparation required for zirconia crown is incisal 2.5-3.0 mm, mesiodistal 1.5-2.0 mm, labial 0.5-1.0 mm. Cingulum should be trimmed parallel to the long axis. No more lingual reduction is needed in central incisors whereas additional 0.5 mm reduction is suggested in lateral incisors.

Development of $^{192}Ir$ Small-Focal Source for Non-Destructive Testing Application by Using Enriched Target Material (고농축 표적을 이용한 비파괴검사용 $^{192}Ir$ 미세초점선원 개발)

  • Son, K.J;Hong, S.B.;Jang, K.D.;Han, H.S.;Park, U.J.;Lee, J.S.;Kim, D.H.;Han, K.D.;Park, C.D.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.1
    • /
    • pp.31-37
    • /
    • 2007
  • A $^{192}Ir$ small-focal source has been developed by using the HANARO reactor and the radioisotope production facility at the Korea Atomic Energy Research Institute (KAERI). The small-focal source with the dimension of 0.5 mm in diameter and 0.5 mm in length was fabricated as an aluminum-encapsulated form by a specially designed pressing equipment. For the estimation of the radioactivity, neutron self-shielding and ${\gamma}-ray$ self-absorption effects on the measured activity was considered. From this estimation, it is realized that $^{192}Ir$ small-focal sources over 3 Ci activities can be produced from the HANARO. Field performance tests were performed by using a conventional source and the developed source to take images of a computer CPU and a piece of a carbon steel. The small-focal source showed better penetration sensitivity and geometrical sharpness than the conventional source does. It is concluded from the tests that the focal dimension of this source is small enough to maximize geometrical sharpness in the image taking for the close proximity shots, pipeline crawler applications and contact radiography.

Three Dimensional Implementation of Intelligent Transportation System Radio Frequency Module Packages with Pad Area Array (PAA(Pad Area Array)을 이용한 ITS RF 모듈의 3차원적 패키지 구현)

  • Jee, Yong;Park, Sung-Joo;Kim, Dong-Yong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.1
    • /
    • pp.13-22
    • /
    • 2001
  • This paper presents three dimensional structure of RF packages and the improvement effect of its electrical characteristics when implementing RF transceivers. We divided RF modules into several subunits following each subunit function based on the partitioning algorithm which suggests a method of three dimension stacking interconnection, PAA(pad area array) interconnection and stacking of three dimensional RF package structures. 224MHz ITS(Intelligent Transportation System) RF module subdivided into subunits of functional blocks of a receiver(RX), a transmitter(TX), a phase locked loop(PLL) and power(PWR) unit, simultaneously meeting the requirements of impedance characteristic and system stability. Each sub­functional unit has its own frequency region of 224MHz, 21.4MHz, and 450KHz~DC. The signal gain of receiver and transmitter unit showed 18.9㏈, 23.9㏈. PLL and PWR modules also provided stable phase locking, constant voltages which agree with design specifications and maximize their characteristics. The RF module of three dimension stacking structure showed $48cm^3$, 76.9% reduction in volume and 4.8cm, 28.4% in net length, 41.8$^{\circ}C$, 37% in maximum operating temperature, respectively. We have found that three dimensional PAA package structure is able to produce high speed, high density, low power characteristics and to improve its functional characteristics by subdividing RF modules according to the subunit function and the operating frequency, and the features of physical volume, electrical characteristics, and thermal conditions compared to two dimensional RF circuit modules.

  • PDF

INFLUENCE OF CAVITY SIZE AND RESTORATION METHODS ON THE CUSP DEFLECTION IN COMPOSITE RESTORATION (복합레진 수복시 와동의 크기 및 수복 방법이 교두 굴곡에 미치는 영향)

  • Lee Mi-Ra;Lee In-Bog;Seok Chang-In;Lee Sang-Tag;Um Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.6
    • /
    • pp.532-540
    • /
    • 2004
  • The aim of this study was to measure the cusp deflection during composite restoration for MOD cavity in premolar and to examine the influence of cavity dimension, C-factor and restoration method on the cusp deflection. Thirty extracted maxillary premolar were prepared to four different sizes of MOD cavity and divided into six groups. The width and depth of the cavity were as follows. Group 1; $1.5{\;}{\times}{\;}1{\;}mm$, Group 2; $1.5{\;}{\times}{\;}2{\;}mm$, Group 3; $3{\;}{\times}{\;}1{\;}mm$, and Group 4-6; $3{\;}{\times}{\;}2{\;}mm$ respectively. Group 1-4 were restored using bulk filling method with Z-250 composite. However, Group 5 was restored incrementally, and Group 6 was restored with an indirect resin inlay. The cusp deflection was recorded at the buccal and lingual cusp tips using LVDT probe for 10,000 seconds. The measured cusp deflections were compared between groups, and the relationship between the cube of the length of cavity wall/the cube of the thickness of cavity wall ($L^3/T^3$). C-factor and cusp deflection or % flexure ($100{\;}{\times}$ cuspal deflection / cavity width) was analyzed. The cusp deflection of Group 1-4 were $12.1{\;}\mu\textrm{m},{\;}17.2{\;}\mu\textrm{m},{\;}16.2{\;}\mu\textrm{m}{\;}and{\;}26.4{\;}\mu\textrm{m}$ respectively. The C-factor was related to the % flexure rather than the cusp deflection. There was a strong positive correlationship between the $L^3/T^3$ and the cusp deflection. The cusp deflection of Group 5 and 6 were $17.4{\;}\mu\textrm{m}{\;}and{\;}17.9{\;}\mu\textrm{m}$ respectively, which are much lower value than that of Group 4.

A STUDY ON THE CORRELATIONSHIP OF SUBMENTOVERTEX VIEW AND LATERAL CEPHALOGRAM MEASUREMENTS (이하두정방사선사진과 측모두부방사선사진상에서의 계측치 상호연관성에 관한연구)

  • Cho, Jae-Hyung;Ryu, Young-Kyu
    • The korean journal of orthodontics
    • /
    • v.26 no.4
    • /
    • pp.414-420
    • /
    • 1996
  • Cephalometric measureements have disadvantage of representing cranio-facial structures in two dimension only and therefore they pose limitations in describing three-dimentional structures of cranio-facial region. More interests have been put on the correlation between the two planes. This study evaluated correlations between facial type score, which allows effects on malocclusion, growth change prediction and establishment of treatment method and prognosis, and measurements from submentovertex view. Cephalometric view and submentovertex view were taken of skeletal Class I adults with optimal profile and correlations between them have been observed. Following results were obtained: 1. To learn about factors that influence average condylar angulation, FACE, INT-CO-ANG, MN-CORPUS, CON-RATIO, GON-RATIO, MN-RATIO were used as variables and underwent multiple regression analysis. As a result, the following equation was obtained : CON-AVE=.l73(FACE)-.322(INT-CO-ANG)+36.34(GON-RATIO) +.420(MN-CORPUS) (($R^2=.85451$) 2. The following equation was obtained concerning facial type score. FACE= .050(CON-ANG)+.023(INT-CO-ANG)-.075(MN-CORPUS)($R^2=.31547$) 3. Among the submentovertex measurements, MN-CORPUS, CON-RATIO, GON-RATIO, MN-RATIO showed close correlations. (P<0.05) 4. Average condylar angualtions were $23.37^{\circ}$ on the right and $20.71^{\circ}$ on left. There was a difference between the two. FACE : facial type soore. CON-ANG: mean value of condylar angulation. CON-AVE: mean value of Rt. Lt condylar angulation. INT-CO-ANG : angle between Rt. Lt condylar axis. MN-CORPUS : angle formed between RT. Lt gonion & pogonion. CON-RATIO: lntercondylar distance/mandibular body length. GON-RATIO : intergonion distanoe/mandibular body length. MN-RATIO: lntermylohyoid distance/mandibular body length. MX-RATIO: intermaxillary tuberosity distance/ANS-PNS distance.

  • PDF

A Study on Branchwood Fiber of Quercus serrata Thunb. (졸참나무 지재(枝材) 섬유(纖維)에 관한 연구(硏究))

  • Lee, Phil Woo;Eom, Young Guen
    • Journal of Korean Society of Forest Science
    • /
    • v.60 no.1
    • /
    • pp.45-50
    • /
    • 1983
  • According to the worldwide decreasing tendency in raw materials and increase in wood demands since 1970, the efficient utilization of raw materials was required internationally. Therefore this study dealt with the dimensional characteristics of branchwood fiber of Quercus serrata Thunb for the complete utilization of whole tree. According to the branch individuals, parts and positions within a tree, fiber length, width and wall-thickness were measured. The results obtained are as follows: 1) As the height of individual branchwood increases from ground toward, fiber length and width, and wall-thickness decreased linearly and their regression equations obtained, were Y=770.03-22.643X, Y=27.444-0.71385X and Y=12.308-0.57320X respectively 2) From the main stem to branch in distal direction, fiber length, width and wall-thickness linearly decreased and their regression equations obtained were Y=752.70-0.6724X, Y=26.152-0.0084867X and Y=11.258-0.006205X, respectively. 3) As the radial direction from pith to hark increases, fiber length, width and wall-thickness increased linearly and their regression equations obtained were Y=679.73+11.231X Y=25.382+0.0925X and Y=10.521+0.11787X, respectively. 4) Mean value of fiber length, width and wall-thickness were 625-765, 26 and $11{\mu}m$, respectively.

  • PDF

A LONGITUDINAL ROENTGENO-CEPHALOMETRIC STUDY ON THE CEPHALO-FACIO-DENTAL RELATIONSHIPS OF NORMAL KOREAN CHILDREN AGED FROM 6 TO 11 YEARS BY SASSOUNI'S ANALYSIS (Sassouni분석법에 의한 한국 아동의 두개, 안모, 치아의 상호관계 변화에 관한 누년적 연구)

  • Ryu, Young Kyu
    • The korean journal of orthodontics
    • /
    • v.17 no.2
    • /
    • pp.165-183
    • /
    • 1987
  • The purpose of this study is to investigate the cephalo-facio-dental relationships in the craniofacial complex and their changes with age, and to use them for diagnostic and treatment purposes in the orthodontics The author studied on the changes of the cephalo-facio-dental relationships, using serial lateral cephalometric roentgenograms of 46 boys and 47 girls aged from 6 to 11 years of normal Korean children Following results were obtained 1 Means and Standard deviation of Korean children were obtained. 2 In the evaluation of the craniofacial vertical proportions, lower anterior face was larger than the upper, and upper posterior face was larger than the lower at all ages 3 The growth change was more prominent in the anterior craniofacial vertical proportion than in the posterior, and growth increment in the upper anterior facial height dimension was larger than m the lower anterior. 4 In the evaluation of the craniofacial horizontal proportion, ANS, Pog, Go and 6 were all situated posterior to their reference ares, and point B was always situated anterior to the arc passing by point A. 5. Anteroposterior growth change was the most prominent in the mandible, and there was no significant difference between the horizontal growth increment in the cranial base and that in the maxilla 6 Growth increment in the horizontal direction was larger in the mandibular apical base than in the maxillary apical base 7 The upper central incisor and the upper first molar were gradually anterior positioned against their reference ares with age increase 8 The length of mandibular corpus was larger than that of cranial base from the seven years old, and the difference was increased as the age increased 9 With age, there was slight difference in the angular relationships formed by craniofacial reference planes and axial inclinations of upper and lower permanent teeth.

  • PDF

Computer Tomography as a Tool for Physical Analysis in an Anthropogenic Soil

  • Chun, Hyen Chung;Park, Chan Won;Sonn, Yeon Kyu;Cho, Hyun Joon;Hyun, Byung Keun;Song, Kwan Cheol;Zhang, Yong Seon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.46 no.6
    • /
    • pp.549-555
    • /
    • 2013
  • Human influence on soil formation has dramatically increased as the development of human civilization and industry. Increase of anthropogenic soils induced research of those soils; classification, chemical and physical characteristics and plant growth of anthropogenic soils. However there have been no reports on soil pore properties from the anthropogenic soils so far. Therefore the objectives of this study were to test computer tomography (CT) to characterize physical properties of an anthropogenic paddy field soil and to find differences between natural and anthropogenic paddy field soils. Soil samples of a natural paddy field were taken from Ansung, Gyeonggi-do (Ansung site), and samples of an anthropogenic paddy field were from Gumi in Gyeongsangnam-do (Gasan) where paddy fields were remodeled in 2011-2012. Samples were taken at three different depths and analyzed for routine physical properties and CT scans. CT scan provided 3 dimensional images to calculate pore size, length and tortuosity of soil pores. Fractal analysis was applied to quantify pore structure within soil images. The results of measured physical properties (bulk density, porosity) did not show differences across depths and sites, but hardness and water content had differences. These differences repeated within the results of pore morphology. Top soil samples from both sites had greater pore numbers and sizes than others. Fractal analyses showed that top soils had more heterogeneous pore structures than others. The bottom layer of the Gasan site showed more degradation of pore properties than ploughpan and bottom layers from the Ansung site. These results concluded that anthropogenic soils may have more degraded pore properties as depth increases. The remodeled paddy fields may need more fundamental remediation to improve physical conditions. This study suggests that pore analyses using CT can provide important information of physical conditions from anthropogenic soils.

High-Q Spiral Zeroth-Order Resonators for Wireless Power Transmission (무선 전력 전송용 High-Q 스파이럴 영차 공진기)

  • Park, Byung-Chul;Park, Jae-Hyun;Lee, Jeong-Hae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.3
    • /
    • pp.343-354
    • /
    • 2012
  • In this paper, various spiral zeroth-order resonators are proposed for wireless power transmission. Since a zerothorder resonance(ZOR) mode of meta-material transmission lines has the characteristic of an infinite wavelength, its frequency is independent of physical length. Also, to obtain high transmission efficiencies high-Q resonators and strong coupling coefficient between coupled resonators are required. Therefore, the resonators consist of spiral inductor and lumped capacitor to use the ZOR mode and they are optimized via parametric study and circuit analysis for a high-Q resonator design. The optimized resonators are simulated and compared with a conventional spiral resonator and one of them was fabricated and measured. The fabricated one has a dimension of $20cm{\times}20cm{\times}8cm$($0.009{\lambda}_0{\times}0.009_{\lambda}_0{\times}0.004{\lambda}_0$) and the transmission efficiency of 80 % is measured at 13.56 MHz at transmitted distance of 40 cm.