• 제목/요약/키워드: Length

검색결과 39,114건 처리시간 0.055초

가속도계와 기압계를 이용한 경사면에서의 보행 거리 추정 (Step Length Estimation on a Slope Using Accelerometers and a Barometer)

  • 트란나헝;서영수
    • 제어로봇시스템학회논문지
    • /
    • 제19권4호
    • /
    • pp.334-340
    • /
    • 2013
  • Using a relationship between step length and accelerometer output, step length can be estimated. In this paper, we propose a new step length estimation algorithm, which can be used both for the plane and the slope by compensating the slope angle. The slope angle is estimated using a barometer and the slope angle is compensated by observing how the slope affects the step length estimation. The proposed algorithm is verified using five adult man walking data, where the average length error is about 3% regardless of the slope.

프리텐션 프리스트레스트 콘크리트 부재의 정착길이 평가 (Experimental study on development length of prestressing strand in pretensioned prestressed concrete members)

  • 김의성
    • 건설안전기술
    • /
    • 통권49호
    • /
    • pp.84-91
    • /
    • 2009
  • By bond mechanism between the prestressing strand and the concrete surrounding it, the effective force of prestressing must be transferred to the concrete entirely. The distance required to transfer the effective force of prestressing is called the transfer length, and the development length is the bond length required to anchor the strand as it resists external loads on the member. Transfer length was determined from the concrete strain profile at the level of the strands at transfer and development length was determined from various external loading lengths and compared with current code equation. Through the test results, bond failure is predicted based on the distress caused by cracks when they propagate within the transfer zone of prestressing strand. The current code equation was found to be conservative in comparison with the measured value.

  • PDF

한글 Graphic Image Date의 통계적 특성에 관한 연구 (A Study on the Statistical characteristics of Hagul Graphic Image Date)

  • 김재석;김재균
    • 대한전자공학회논문지
    • /
    • 제17권2호
    • /
    • pp.15-22
    • /
    • 1980
  • Graphic image data의 효율적인 coding을 위해서, 한글 image와 영문 image의 통계적인 특성들이 측정 비교되었다. 또한 Markov model에 의한 run length의 확률분포와 측정된 run length의 확률분포가 비교 검토되었다. 측정된 run length 분포는 negative-power 분포에 유사하며, 이것은 한글 image 에서 더욱 뚜렷한 것으로 나타났다. 대표적 네가지 run length code의 coding 특성이 비교되었는데, 영문 image보다 한글image의 coding 특성이 더욱 우수한 것으로 밝혀졌다.

  • PDF

Y-Jet 노즐에서의 혼합관 길이변화에 따른 분무특성 연구 (Change of Spray Characteristics with Mixing Port Length of Y-Jet Atomizers)

  • 송시홍;이상용
    • 대한기계학회논문집
    • /
    • 제18권11호
    • /
    • pp.3021-3031
    • /
    • 1994
  • Experiments have been performed to find out the effect of the mixing port length of Y-jet atomizers on the spray performance, using air and water as the test fluids. Water and air flow rates and drop sizes were measured at each injection pressure condition for different mixing port length. The air flow rate was almost unaffected by the change of the mixing port length. However, the water flow rate was relatively susceptible to the change of the mixing port length. The mixing point pressure was very much influenced by the mixing port length. Variations of spatial distribution of Sauter Mean Diameter (SMD, $D_{32}$) and the cross-section-averaged SMD ($D_{32,m}$) with different mixing port length and air/water mass flow rate ratio were examined. Generally, when the mixing port length was reduced, the mean drop size decreased and became spatially even.

부재의 길이가 콘크리트의 휨압축강도에 미치는 영향 (Effects of Specimen Length on Flexural Compressive Strength of Concrete)

  • 김진근;이성태;이태규
    • 콘크리트학회논문집
    • /
    • 제11권4호
    • /
    • pp.63-71
    • /
    • 1999
  • In evaluating the ultimate strength of a section for a reinforced concrete flexural member, the effect of member length is not usually considered, even though the strength tends to decrease with increase of member length. In this paper the influence of specimen length on flexural compressive strength of concrete was evaluated. For this purpose, a series of C-shaped specimens subjected to axial compression and bending moment were tested using four different length-to-depth ratios (from 1,2,3 and 4) of specimens with compressive strength of 590 kgf/$\textrm{cm}^2$. Results indicate that for the region of h/c <3.0 the reduction in flexural compressive strength with increase of length-to-depth ratios was apparent. A model equation was depth of an equivalent rectangular stress block was larger than that by ACI. It was also founded that the effect of specimen length on ultimate strain was negligible. Finally more general model equation is also suggested.

Optimization of a Thermally Asymmetric Rectangular Fin: Based on Fixed Fin Height

  • Kang, Hyung-Suk
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제13권3호
    • /
    • pp.145-151
    • /
    • 2005
  • A thermally asymmetric straight rectangular fin is analysed and optimized using the two-dimensional separation of variables method. The optimum heat loss is presented as a function of bottom to top Biot number ratio, fin base length and top Biot number. Decreasing rate of the optimum fin length with the increase of the fin base length is listed. The optimum fin tip length is shown as a function of bottom to top Biot number ratio, fin base length and tip to top Biot number ratio. One of the results shows that the optimum heat loss and the actual optimum fin length decrease while the optimum fin tip length increases as the fin base length increases.

프리텐션 프리스트레스트 콘크리트 부재의 정착길이 정가 (Experimental Study on Development Length of Prestressing Strand in Pretensioned Prestressed Concrete Members)

  • 김의성
    • 한국안전학회지
    • /
    • 제23권6호
    • /
    • pp.115-121
    • /
    • 2008
  • By bond mechanism between the prestressing strand and the concrete surrounding it, the effective force of prestressing must be transferred to the concrete entirely. The distance required to transfer the effective force of prestressing is called the transfer length, and the development length is the bond length required to anchor the strand as it resists external loads on the member. Transfer length was determined from the concrete strain profile at the level of the strands at transfer and development length was determined from various external loading lengths and compared with current code equation. Through the test results, bond failure is predicted based on the distress caused by cracks when they propagate within the transfer zone of prestressing strand. The current code equation was found to be conservative in comparison with the measured value.

전단동축형 분사기들의 미립화 특성에 대한 연구 (Study on Atomization Characteristics of Shear Coaxial Injectors)

  • 안종현;이근석;안규복
    • 한국분무공학회지
    • /
    • 제26권1호
    • /
    • pp.9-17
    • /
    • 2021
  • Six shear coaxial injectors with different recess length and taper angle were manufactured. Cold-flow tests on the injectors were performed at room temperature and pressure using water and air as simulants. By changing the water mass flow rate and air mass flow rate, spray images were taken under single-injection and bi-injection. Breakup length and spray angle were analyzed from instantaneous and averaged spray images using image processing techniques. For all the injectors, the breakup length generally decreased as the momentum flux ratio increased at the same gas mass flow rate. The injectors with 7.5° taper angle usually had the longest breakup length and the smallest spray angle. When the taper angle was 15° or more, it hardly affected breakup length and spray angle. The recess length did not influence breakup length but its effect on spray angle depended on the taper angle.

A WEAKER NOTION OF THE FINITE FACTORIZATION PROPERTY

  • Henry Jiang;Shihan Kanungo;Hwisoo Kim
    • 대한수학회논문집
    • /
    • 제39권2호
    • /
    • pp.313-329
    • /
    • 2024
  • An (additive) commutative monoid is called atomic if every given non-invertible element can be written as a sum of atoms (i.e., irreducible elements), in which case, such a sum is called a factorization of the given element. The number of atoms (counting repetitions) in the corresponding sum is called the length of the factorization. Following Geroldinger and Zhong, we say that an atomic monoid M is a length-finite factorization monoid if each b ∈ M has only finitely many factorizations of any prescribed length. An additive submonoid of ℝ≥0 is called a positive monoid. Factorizations in positive monoids have been actively studied in recent years. The main purpose of this paper is to give a better understanding of the non-unique factorization phenomenon in positive monoids through the lens of the length-finite factorization property. To do so, we identify a large class of positive monoids which satisfy the length-finite factorization property. Then we compare the length-finite factorization property to the bounded and the finite factorization properties, which are two properties that have been systematically investigated for more than thirty years.

골-슬개건-골을 이용한 관절경적 전방십자인대 재건술시 이식물-터널 길이의 부조화를 줄이는 방법 (The Resolving Method of Graft-Tunnel Mismatch in Arthroscopic ACL Reconstruction Using Bone-Patellar Tendon-Bone Graft)

  • 조세현;박형빈;하성진
    • 대한관절경학회지
    • /
    • 제3권2호
    • /
    • pp.97-101
    • /
    • 1999
  • 목 적 : 각 환자의 슬개건 길이, 터널간 길이, 경골 터널 길이, 경골 골편의 길이를 측정하여 이식물과 터널 길이의 부조화를 예방하는 수기를 찾고자 하였다. 대상 및 방법 : 1997년 3월부터 1999년 6월까지 골-슬개건-골을 이용하여 전방십자인대 재건술을 시행 받았던 환자 15례를 대상으로 하였다. 수술시 Tibial Tunnel Guide의 각도는 $40^{\circ}$(Acufex, MA, USA)로 고정하였으며, 터널간 길이(X), 경골 터널 길이(T), 슬개건 길이(N), 경골 골편 길이(Y)를 측정하였다. 대퇴골 터널 길이(F)와 슬개골 골편 길이(P)는 공히 25mm로 일치시켰다. 터널 길이 부조화를 예방하기 위해 임의적으로 조절이 용이한 경골 골편의 길이는 경골 터널 길이와 터널간 길이를 합하여 슬개건 길이를 뺀 단순 공식(Y=X+T-N)으로 계산하였다. 결 과 : 대상환자에게 측정한 지표들의 평균값은 터널간 길이(X) $23.4{\pm}1.4mm$, 경골 터널 길이(T) $43.6{\pm}1.7mm$, 슬개건 길이(N) $40{\pm}2.4mm$, 경골 골편 길이(Y) $27{\pm}2.4mm$였다. 결 론 : 저자들의 방법은 터널의 총길이를 측정한 후 이식물의 총길이를 경골 골편 길이로 조정함으로써 경골터널 내에서의 이식물-터널 길이 부조화를 방지할 수 있었다.

  • PDF