• 제목/요약/키워드: Left ventricular strain

검색결과 17건 처리시간 0.017초

Multi-scale modelling of the blood chamber of a left ventricular assist device

  • Kopernik, Magdalena;Milenin, Andrzej
    • Advances in biomechanics and applications
    • /
    • 제1권1호
    • /
    • pp.23-40
    • /
    • 2014
  • This paper examines the blood chamber of a left ventricular assist device (LVAD) under static loading conditions and standard operating temperatures. The LVAD's walls are made of a temperature-sensitive polymer (ChronoFlex C 55D) and are covered with a titanium nitride (TiN) nano-coating (deposited by laser ablation) to improve their haemocompatibility. A loss of cohesion may be observed near the coating-substrate boundary. Therefore, a micro-scale stress-strain analysis of the multilayered blood chamber was conducted with FE (finite element) code. The multi-scale model included a macro-model of the LVAD's blood chamber and a micro-model of the TiN coating. The theories of non-linear elasticity and elasto-plasticity were applied. The formulated problems were solved with a finite element method. The micro-scale problem was solved for a representative volume element (RVE). This micro-model accounted for the residual stress, a material model of the TiN coating, the stress results under loading pressures, the thickness of the TiN coating and the wave parameters of the TiN surface. The numerical results (displacements and strains) were experimentally validated using digital image correlation (DIC) during static blood pressure deformations. The maximum strain and stress were determined at static pressure steps in a macro-scale FE simulation. The strain and stress were also computed at the same loading conditions in a micro-scale FE simulation.

Global Left Ventricular Myocardial Work Efficiency in Patients With Severe Rheumatic Mitral Stenosis and Preserved Left Ventricular Ejection Fraction

  • Estu Rudiktyo;Amiliana M Soesanto;Maarten J Cramer;Emir Yonas;Arco J Teske;Bambang B Siswanto;Pieter A Doevendans
    • Journal of Cardiovascular Imaging
    • /
    • 제31권4호
    • /
    • pp.191-199
    • /
    • 2023
  • BACKGROUND: Assessment of left ventricular (LV) function plays a pivotal role in the management of patients with valvular heart disease, including those caused by rheumatic heart disease. Noninvasive LV pressure-strain loop analysis is emerging as a new echocardiographic method to evaluate global LV systolic function, integrating longitudinal strain by speckle-tracking analysis and noninvasively measured blood pressure to estimate myocardial work. The aim of this study was to characterize global LV myocardial work efficiency in patients with severe rheumatic mitral stenosis (MS) with preserved ejection fraction (EF). METHODS: We retrospectively included adult patients with severe rheumatic MS with preserved EF (> 50%) and sinus rhythm. Healthy individuals without structural heart disease were included as a control group. Global LV myocardial work efficiency was estimated with a proprietary algorithm from speckle-tracking strain analyses, as well as noninvasive blood pressure measurements. RESULTS: A total of 45 individuals with isolated severe rheumatic MS with sinus rhythm and 45 healthy individuals were included. In healthy individuals without structural heart disease, the mean global LV myocardial work efficiency was 96% (standard deviation [SD], 2), Compared with healthy individuals, median global LV myocardial work efficiency was significantly worse in MS patients (89%; SD, 4; p < 0.001) although the LVEF was similar. CONCLUSIONS: Individuals with isolated severe rheumatic MS and preserved EF, had global LV myocardial work efficiencies lower than normal controls.

What Is Normal for an Aging Heart?: A Prospective CMR Cohort Study

  • Johannes Kersten;Carsten Hackenbroch;Muriel Bouly;Benoit Tyl;Peter Bernhardt
    • Journal of Cardiovascular Imaging
    • /
    • 제30권3호
    • /
    • pp.202-211
    • /
    • 2022
  • BACKGROUND: This study aims to investigate normal changes throughout aging of the heart in cardiac magnetic resonance (CMR) imaging in healthy volunteers. While type 2 diabetes mellitus is a frequent finding in the elderly population, also the influence of this circumstance in otherwise healthy persons is part of our study. METHODS: In this prospective single-center trial, 75 healthy subjects in distinct age groups and 10 otherwise healthy diabetics were enrolled. All subjects underwent functional, flow sensitive, native T2- and T1-mapping in a 1.5T CMR scanner. RESULTS: No differences in right and left ventricular ejection fractions were observed between aging healthy groups. Bi-ventricular volumes lowered significantly (p<0.001) between the age groups. There was also a significant decrease in myocardial T1 values, aortic distensibility, and left ventricular peak diastolic strain rates. There were no differences in T2 mapping and the other deformation parameters. Patients with type 2 diabetes mellitus had lower end-diastolic volume indexes; all the other measurements were comparable. CONCLUSIONS: Aging processes in the healthy heart involve a decrease in ventricular volumes, with ejection fractions remaining normal. Stiffening of the myocardium and aorta and a decrease in T1 values are potential indications of age-related remodeling. Type 2 diabetes mellitus seems to have no major influence on aging processes of the heart.

Echocardiography Core Laboratory Validation of a Novel Vendor-Independent Web-Based Software for the Assessment of Left Ventricular Global Longitudinal Strain

  • Ernest Spitzer;Benjamin Camacho;Blaz Mrevlje;Hans-Jelle Brandendburg;Claire B. Ren
    • Journal of Cardiovascular Imaging
    • /
    • 제31권3호
    • /
    • pp.135-141
    • /
    • 2023
  • BACKGROUND: Global longitudinal strain (GLS) is an accurate and reproducible parameter of left ventricular (LV) systolic function which has shown meaningful prognostic value. Fast, user-friendly, and accurate tools are required for its widespread implementation. We aim to compare a novel web-based tool with two established algorithms for strain analysis and test its reproducibility. METHODS: Thirty echocardiographic datasets with focused LV acquisitions were analyzed using three different semi-automated endocardial GLS algorithms by two readers. Analyses were repeated by one reader for the purpose of intra-observer variability. CAAS Qardia (Pie Medical Imaging) was compared with 2DCPA and AutoLV (TomTec). RESULTS: Mean GLS values were -15.0 ± 3.5% from Qardia, -15.3 ± 4.0% from 2DCPA, and -15.2 ± 3.8% from AutoLV. Mean GLS between Qardia and 2DCPA were not statistically different (p = 0.359), with a bias of -0.3%, limits of agreement (LOA) of 3.7%, and an intraclass correlation coefficient (ICC) of 0.88. Mean GLS between Qardia and AutoLV were not statistically different (p = 0.637), with a bias of -0.2%, LOA of 3.4%, and an ICC of 0.89. The coefficient of variation (CV) for intra-observer variability was 4.4% for Qardia, 8.4% 2DCPA, and 7.7% AutoLV. The CV for inter-observer variability was 4.5%, 8.1%, and 8.0%, respectively. CONCLUSIONS: In echocardiographic datasets of good image quality analyzed at an independent core laboratory using a standardized annotation method, a novel web-based tool for GLS analysis showed consistent results when compared with two algorithms of an established platform. Moreover, inter- and intra-observer reproducibility results were excellent.

Prognostic Role of Right VentricularPulmonary Artery Coupling Assessed by TAPSE/PASP Ratio in Patients With Acute Heart Failure

  • Youngnam Bok;Ji-Yeon Kim;Jae-Hyeong Park
    • Journal of Cardiovascular Imaging
    • /
    • 제31권4호
    • /
    • pp.200-206
    • /
    • 2023
  • BACKGROUND: Right ventricular (RV) dysfunction is a significant risk of major adverse cardiac events in patients with acute heart failure (AHF). In this study, we evaluated RV-pulmonary artery (PA) coupling, assessed by tricuspid annular plane systolic excursion (TAPSE)/pulmonary artery systolic pressure (PASP) and assessed its prognostic significance, in AHF patients. METHODS: We measured the TAPSE/PASP ratio and analyzed its correlations with other echocardiographic parameters. Additionally, we assessed its prognostic role in AHF patients. RESULTS: A total of 1147 patients were included in the analysis (575 men, aged 70.81 ± 13.56 years). TAPSE/PASP ratio exhibited significant correlations with left ventricular (LV) ejection fraction(r = 0.243, p < 0.001), left atrial (LA) diameter(r = -0.320, p < 0.001), left atrial global longitudinal strain (LAGLS, r = 0.496, p < 0.001), mitral E/E' ratio(r = -0.337, p < 0.001), and right ventricular fractional area change (RVFAC, r = 0.496, p < 0.001). During the median follow-up duration of 29.0 months, a total of 387 patients (33.7%) died. In the univariate analysis, PASP, TAPSE, and TAPSE/PASP ratio were significant predictors of mortality. After the multivariate analysis, TAPSE/PASP ratio remained a statistically significant parameter for all-cause mortality (hazard ratio [HR], 0.453; p = 0.037) after adjusting for other parameters. In the receiver operating curve analysis, the optimal cut-off level of TAPSE/PASP ratio for predicting mortality was 0.33 (area under the curve = 0.576, p < 0.001), with a sensitivity of 65% and a specificity of 47%. TAPSE/PASP ratio < 0.33 was associated with an increased risk of mortality after adjusting for other variables (HR, 1.306; p = 0.025). CONCLUSIONS: In AHF patients, TAPSE/PASP ratio demonstrated significant associations with RVFAC, LA diameter and LAGLS. Moreover, a decreased TAPSE/PASP ratio < 0.33 was identified as a poor prognostic factor for mortality.

Left Atrial Velocity Vector Imaging Can Assess Early Diastolic Dysfunction in Left Ventricular Hypertrophy and Hypertrophic Cardiomyopathy

  • Se-Jung Yoon;Sungha Park;Eui-Young Choi;Hye-Sun Seo;Chi Young Shim;Chul Min Ahn;Sung-Ai Kim;Jong-Won Ha
    • Journal of Cardiovascular Imaging
    • /
    • 제31권1호
    • /
    • pp.41-48
    • /
    • 2023
  • BACKGROUND: The function of left atrium (LA) is difficult to assess because of its ventricle-dependent, dynamic movement. The aim of this study was to assess LA function using velocity vector imaging (VVI) and compare LA function in patients with hypertrophic cardiomyopathy (HCMP) and left ventricular hypertrophy (LVH) with normal controls. METHODS: Fourteen patients with HCMP (72% male, mean age of 52.6 ± 9.8), 15 hypertensive patients with LVH (88% male, mean age of 54.0 ± 15.3), and 10 age-matched controls (83% male, mean age of 50.0 ± 4.6) were prospectively studied. Echocardiographic images of the LA were analyzed with VVI, and strain rate (SR) was compared among the 3 groups. RESULTS: The e' velocity (7.7 ± 1.1; 5.1 ± 0.8; 4.5 ± 1.3 cm/sec, p = 0.013), E/e' (6.8 ± 1.6; 12.4 ± 3.3; 14.7 ± 4.2, p = 0.035), and late diastolic SR at mid LA (-1.65 ± 0.51; -0.97 ± 0.55; -0.82 ± 0.32, p = 0.002) were significantly different among the groups (normal; LVH; HCMP, respectively). The e' velocity, E/e', and late diastolic SR at mid LA were significantly different between normal and LVH (p = 0.001; 0.022; 0.018), whereas LA size was similar between normal and LVH (p = 0.592). The mean late diastolic peak SR of mid LA was significantly correlated with indices of diastolic function (E/e', e', and LA size). CONCLUSIONS: The SR is a useful tool for detailed evaluation of LA function, especially early dysfunction of LA in groups with normal LA size.

고혈압 청소년에서 tissue Doppler imaging과 strain rate imaging을 이용한 좌심실 기능 이상에 대한 연구 (Left ventricular dysfunction measured by tissue Doppler imaging and strain rate imaging in hypertensive adolescents)

  • 안혜미;정선옥;권정현;홍영미
    • Clinical and Experimental Pediatrics
    • /
    • 제53권1호
    • /
    • pp.72-79
    • /
    • 2010
  • 목 적 : 고혈압에서 이완기 기능 이상은 수축기 기능 장애가 나타나기 전에 질환 경과에 일찍 발견되고 흔하게 관찰된다. 이완기 심기능을 평가하기에는 TDI가 고식적 심초음파보다 더 우수한 것으로 알려져 있다. 그러나 소아 및 청소년에서의 연구는 많지 않은 실정이다. 청소년 고혈압에서 심실 기능 이상을 발견하는데 있어서 SRI의 유용성을 알아보고자 본 연구를 실시하였다. 방 법: 수축기 혈압이 140 mmHg 이상이거나 이완기 혈압이 90 mmHg이상인 고혈압을 가진 16-17세 사이의 38명의 청소년을 대상군으로 하였고, 같은 연령의 정상 혈압을 가진 청소년 19명을 대조군으로 하였다. M-mode 심초음파로 심실 중격 두께, 좌심실 후벽 두께를 측정하였고, 이면성 심초음파로 ejection fraction (EF), myocardial performance index (MPI)를 측정하였다. TDI를 이용하여 심근 수축기 심근속도, E 심근속도, A 심근속도를 측정하였고, SRI를 이용하여 strain과 strain rate을 측정하였다. 결 과: M-mode 심초음파 소견상 심실벽 두께, 좌심실 후벽 두께가 고혈압군에서 유의하게 증가하였다. EF, MPI와 modified MPI는 두군간에 유의한 차이가 없었다. 고식적 심초음파 검사결과 고혈압군에서 A 혈류속도가 유의하게 증가되었고, TDI 검사상 A 심근 속도는 고혈압군에서 유의하게 증가하였고 E/A 심근속도비는 유의하게 감소되었다. SRI에 의한 E strain rate은 고혈압군에서 기저, 중간 부위, 심첨부에서 유의하게 감소되었고, strain은 중격에서 고혈압군은 $19.15{\pm}8.65%$, 정상군은 $22.63{\pm}5.55%$으로 고혈압군에서 유의하게 감소하였다(P<0.05). 결 론 : 고식적 초음파로는 좌심실 이완기 기능 이상만 관찰되었으나 SRI로 좌심실 이완 기능 외에 수축 기능이 유의하게 감소됨을 알 수 있었다. SRI를 이용하여 심실 기능의 이상을 조기에 발견할 수 있었다. 앞으로 더 많은 고혈압 청소년을 대상으로 한 연구가 필요할 것으로 생각한다.

Seven-day and In-hospital Mortality According to Left and Right Ventricular Dysfunction in Patients With Septic Shock

  • Sua Kim;Hyeri Seok;Beong Ki Kim;Yu Jin Kim;Seung Heon Lee;Je Hyeong Kim;Yong-Hyun Kim
    • Korean Circulation Journal
    • /
    • 제53권12호
    • /
    • pp.813-825
    • /
    • 2023
  • Background and Objectives: The prognostic implications of septic cardiomyopathy have not been clearly demonstrated. We evaluated serial changes in left ventricular (LV) and right ventricular (RV) function in patients with septic shock and their prognostic value on 7-day and in-hospital mortality. Methods: Transthoracic echocardiography was performed within 48 hours of the diagnosis of septic shock and 7 days after the initial evaluation. In addition to traditional echocardiographic parameters, LV and RV function was evaluated using global longitudinal strain (GLS), and tricuspid annular plane systolic excursion (TAPSE). Results: A total of 162 patients (men, 83, 51.5%; 70.7±13.4 years; Acute Physiology and Chronic Health Evaluation [APACHE] II, 30.6±9.2) were enrolled. Initial GLS and TAPSE were -14.9±5.2% and 16.9±5.5 mm, and improved in the follow-up evaluation (GLS, -17.6±4.9%; TAPSE, 19.2±5.4 mm). Seven-day and in-hospital mortality were 24 (14.9%) and 64 (39.8%). Seven-day mortality was significantly associated with initial GLS >-16% (odds ratio [OR], 14.066, 95% confidence interval [CI], 1.178-167.969, p=0.037) and APACHE II score (OR, 1.196, 95% CI, 1.047-1.365, p=0.008). The in-hospital mortality of 7-day survivors was associated with follow-up TAPSE <16 mm (OR, 10.109, 95% CI, 1.640-62.322, p=0.013) and Sequential Organ Failure Assessment score (OR, 1.340, 95% CI, 1.078-1.667, p=0.008). GLS was not associated with in-hospital mortality of 7-day survivors. Conclusions: Fluctuation of both ventricular function was common in septic shock. Seven-day mortality of patients with septic shock was related to GLS, whereas in-hospital mortality of 7-day survivors was related to TAPSE, not to GLS.

Subclinical left ventricular dysfunction in children after hematopoietic stem cell transplantation for severe aplastic anemia: a case control study using speckle tracking echocardiography

  • Kim, Beom Joon;Moon, Kyung Pil;Yoon, Ji-Hong;Lee, Eun-Jung;Lee, Jae Young;Kim, Seong Koo;Lee, Jae Wook;Chung, Nack Gyun;Cho, Bin;Kim, Hack Ki
    • Clinical and Experimental Pediatrics
    • /
    • 제59권4호
    • /
    • pp.190-195
    • /
    • 2016
  • Purpose: Severe aplastic anemia (SAA), a fatal disease, requires multiple transfusion, immunosuppressive therapy, and finally, hematopoietic stem cell transplantation (HSCT) as the definitive treatment. We hypothesized that iron overloading associated with multiple transfusions and HSCT-related complications may adversely affect cardiac function. Left ventricular (LV) function was assessed in children after HSCT for SAA. Methods: Forty-six consecutive patients with a median age of 9.8 years (range, 1.5-18 years), who received HSCT for SAA and who underwent comprehensive echocardiography before and after HSCT, were included in this study. The data of LV functional parameters obtained using conventional echocardiography, tissue Doppler imaging (TDI), and speckle-tracking echocardiography (STE) were collected from pre- and post-HSCT echocardiography. These data were compared to those of 40 age-matched normal controls. Results: In patients, the LV ejection fraction, shortening fraction, end-diastolic dimension, mitral early diastolic E velocity, TDI mitral septal E' velocity, and STE LV longitudinal systolic strain rate (SSR) decreased significantly after HSCT. Compared to normal controls, patients had significantly lower post-HSCT early diastolic E velocity and E/A ratio. On STE, patients had significantly decreased LV deformational parameters including LV longitudinal systolic strain (SS), SSR, and diastolic SR (DSR), and circumferential SS and DSR. Serum ferritin levels showed weak but significant correlations (P<0.05) with LV longitudinal SS and SSR and circumferential SS and DSR. Conclusion: Subclinical LV dysfunction is evident in patients after HSCT for SAA, and was associated with increased iron load. Serial monitoring of cardiac function is mandatory in this population.

Changes in Cardiac Structure and Function After Kidney Transplantation: A New Perspective Based on Strain Imaging

  • Darae Kim;Minjeong Kim;Jae Berm Park;Juhan Lee;Kyu Ha Huh;Geu-Ru Hong;Jong-Won Ha;Jin-Oh Choi;Chi Young Shim
    • Journal of Cardiovascular Imaging
    • /
    • 제31권2호
    • /
    • pp.98-104
    • /
    • 2023
  • BACKGROUND: We aimed to investigate left ventricular (LV) global longitudinal strain (GLS) in end-stage renal disease patients and its change after kidney transplantation (KT). METHODS: We retrospectively reviewed patients who underwent KT between 2007 and 2018 at two tertiary centers. We analyzed 488 patients (median age, 53 years; 58% male) who had obtained echocardiography both before and within 3 years after KT. Conventional echocardiography and LV GLS assessed by two-dimensional speckle-tracking echocardiography were comprehensively analyzed. Patients were classified into three groups according to the absolute value of pre-KT LV GLS (|LV GLS|). We compared longitudinal changes of cardiac structure and function according to pre-KT |LV GLS|. RESULTS: Correlation between pre-KT LV EF and |LV GLS| were statistically significant, but the constant was not high (r = 0.292, p < 0.001). |LV GLS| was widely distributed at corresponding LV EF, especially when the LV EF was > 50%. Patients with severely impaired pre-KT |LV GLS| had significantly larger LV dimension, LV mass index, left atrial volume index, and E/e' and lower LV EF, compared to mildly and moderately reduced pre-KT |LV GLS|. After KT, the LV EF, LV mass index, and |LV GLS| were significantly improved in three groups. Patients with severely impaired pre-KT |LV GLS| showed the most prominent improvement of LV EF and |LV GLS| after KT, compared to other groups. CONCLUSIONS: Improvements in LV structure and function after KT were observed in patients throughout the full spectrum of pre-KT |LV GLS|.