• Title/Summary/Keyword: Left to right ratio

Search Result 597, Processing Time 0.03 seconds

Congenital Diaphragmatic Eventration: Report of 4 Cases (선천성 횡경막 내번증)

  • 김자억
    • Journal of Chest Surgery
    • /
    • v.11 no.1
    • /
    • pp.92-96
    • /
    • 1978
  • Congenital diaphragmatic eventration is a rare disease and generally accepted as an abnormally high position of part or all of the diaphragm, usually associated with a marked decrease in muscle fibers and a membranous appearance of the abnormal area. There were 4 cases of the congenital diaphragmatic eventration at the Dept. of Thoracic Surgery, Seoul National University Hospital, from 1957 to 1977. They were two boys and two girls and ranging from 1 day to 3 years of age. They were all repaired by surgical operation and one was expired postoperatively, another one was dead one year later due to complication. The ratio between right and left was 1:3 and their symptoms were cyanosis, dyspnea and frequent respiratory disease. In physical examination there was noted decreased breathing sound on the affected lung field and bowel sound was audible in some cases. Diagnosis was done by Chest X-ray and plication of the affected diaphragm was usually done in operation. There were noted atelectasis and cystic change of the affected side lung. And the liver, colon, spleen and small intestine were found in the dome of the eventrated diaphragm.

  • PDF

Directivity Pattern Simulation of the Ears with Two Pairs' Hearing Aid Microphone Arrays by BEM

  • Jarng Soon Suck;Kwon You Jung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.2E
    • /
    • pp.38-45
    • /
    • 2005
  • The noise reduction of the In-The-Ear (ITE) hearing aid (HA) can be achieved by arrays of microphones. Each of the right and the left ears was assumed to have two HA microphones. These arrays of HA microphones produce particular patterns of directivity by some time delay between two microphones. The directivity pattern geometrically increase the S/N ratio. The boundary element method (BEM) was used for the three dimensional simulation of the HA directivity pattern with the two pairs' microphone arrays. The separation between two microphones was fixed to 10 mm. The time delay between the two microphones was calculated to produce the most narrow directivity pattern in the fore front of the head. The variation of the time delay was examined in accordance with input frequencies. This numerical analysis may be then applied for the calculation of the time delay parameter of the digital hearing aid DSP chip.

Behavior of Lateral Earth Pressure around the Underpass Constructed by the STS Construction Method

  • Jin, Kyu-Nam;Kim, Hyo-Jin;Sim, Young-Jong
    • Land and Housing Review
    • /
    • v.7 no.4
    • /
    • pp.271-279
    • /
    • 2016
  • Recently developed trenchless construction methods ensure stability for the ground settlement by inserting steel pipes along the underpass section and integrating steel pipes before ground excavation to form pipe-roof. This study is to confirm the reinforcing effect of pipe-roof by measuring lateral earth pressure acting on the underpass constructed by the STS (Steel Tube Slab) construction method. For this purpose, lateral earth pressure was measured at the left and right side of the pipe-roof after installing earth pressure cells. As a result, lateral earth pressure was measured with considerable reduction because the integrated pipe-roof shared surcharge. Therefore, economic design for the underpass could be expected by sharing design load by pipe-roof. In addition, construction cost was analyzed according to the design-load sharing ratio by pipe-roof. As pipe-roof shares design load by 40%, the total construction cost can decrease by almost 10% in the case of four-lane underpass.

Traumatic Diaphragmatic Injuries -Report of 12 cases- (외상성 횡경막 손상치험 12예)

  • 이종국
    • Journal of Chest Surgery
    • /
    • v.13 no.1
    • /
    • pp.52-59
    • /
    • 1980
  • Twelve cases of traumatic diaphragmatic injuries were treated at the Chosun University Hospital from Feb. 1977 to Inn. 1980. The following results were obtained. l. Sex ratio incidence was 5:1, which male patients were predominant. 2. The age distribution at these cases, were ranged from 16 to 43 years of age, and average age was 27 years. 3. Left sided traumatic diaphragmatic injuries were far more common than right, which approximately incidence of 5:1 diaphragmatic injuries were due to blunt trauma [7 cases-traffic accident, 1 case-fall down], and stab wound [4 cases] in etiology. 4. Surgical repairs were done through only thoracotomy incision in blunt trauma cases, and through each thoracic and abdominal incision same time in 2 cases of stab wound. 5. 2 cases {16.7%] of blunt trauma were died before operation at emergency room, and no man died during or following operation. An overall mortality was 16.7%.

  • PDF

A Study on Hadamard Transform Imaging Spectrometers utilizing Grill Spectrometers (그릴 스펙트로미터를 적용한 하다마드 트랜스폼 이미징 스펙트로미터에 대한 연구)

  • Park, Yeong-Jae;Park, Jin-Bae;Choi, Yoon-Ho;Yoon, Tae-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1998.07b
    • /
    • pp.601-603
    • /
    • 1998
  • In this paper, Hadamard transform imaging spectrometers utilizing Grill spectrometers are proposed. General Hadamard Transform Spectrometers (HTS) carry out one-encoding through input masks, but Grill spectrometers carry out double-encoding through entrance and exit masks. Thus Grill spectrometers increase the signal-to-noise ratio by double-encoding. we reconfigure the system by using the Grill spectrometers which use a left cyclic S-matrix instead of the conventional right cyclic one. Then, we model the system and apply the mask characteristics method, i.e. $T^{I}$ method, to complete fast algorithm. Through computer simulations, we want to prove the superiority of the proposed system by comparing with the conventional HTS. From Observations concerning the average mean square error(AMSE) associated with estimates from the $T^{I}$ spectrum-recovery method, the relative performances of the two systems are compared.

  • PDF

Analysis of esthetic factors and evaluation of esthetic perception for maxillary anteriors of dental students (치과대학생의 상악 전치부의 심미적 요소 분석 및 인식도 평가)

  • Kim, Seon-Kyung;Kim, Ok-Su
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.118-126
    • /
    • 2019
  • Purpose: This research is to investigate factors that affect dental aesthetics and analyze whether individual perception affects and difference of genders affects the esthetic factors. Materials and methods: Seventy dental students of Chonnam University aged from 25 to 35 years old without periodontal problems were included. Maxillary dental cast for participants were made, and standardized photo was taken with a digital camera. Maximum visual width and the position of gingival zenith of maxillary anterior teeth and maximum height of the maxillary central incisors were measured by a measurement program and the shape of central incisor was categorized. Questionnaire was conducted to evaluate esthetic perception. SPSS program was used to perform statistical analysis. Results: The average visual width ratio of right maxillary anteriors was 1.38:1:0.78 and 1.41:1:0.81 for the left which differ from the golden ratio. The width to height ratio for right and left central incisor was 0.84 and 0.83 respectively. The gingival zenith position was determined to be: mostly, central incisors and canines were located in the distal side, lateral incisors were located in the center. The visual width ratio of right maxillary anterior teeth, ratio of width to height of central incisor, gingival zenith position, crown morphology and amounts of gingival exposure upon smiling were not significantly different between genders, and facial patterns and these dental esthetic factors were not related to aesthetic perception. Conclusion: Even though participants had the visual width ratio of maxillary anteriors or ideal width to ideal height of central incisors that did not agree with the golden ratio, they had high satisfaction for dental esthetics. Esthetic perception depends more on subjective judgements of participants than objective indices.

Is Currency Appreciation or Depreciation Expansionary in Thailand?

  • Hsing, Yu
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.5 no.1
    • /
    • pp.5-9
    • /
    • 2018
  • Many developing countries have attempted to depreciate their currencies in order to make their products cheaper, stimulate exports, shift aggregate demand to the right, and increase aggregate output. However, currency depreciation tends to increase import prices, raise domestic inflation, reduce capital inflows, and shift aggregate supply to the left. The net impact is unclear. The paper incorporates the monetary policy function in the model, which is determined by the inflation gap, the output gap, the real effective exchange rate, and the world real interest rate. Applying an extended IS-MP-AS model (Romer, 2000), the paper finds that real depreciation raised real GDP during 1997.Q1-2005.Q3 whereas real appreciation increased real GDP during 2005.Q4-2017.Q2. In addition, a higher government debt-to-GDP ratio, a lower U.S. real federal funds rate, a higher real stock price, a lower real oil price or a lower expected inflation rate would help increase real GDP. Hence, real depreciation or real appreciation may increase or reduce aggregate output, depending upon the level of economic development. Although expansionary fiscal policy is effective in stimulating the economy, caution needs to be exercised as there may be a debt threshold beyond which a further increase in the debt-to-GDO ratio would hurt economic growth.

Interrelationships and Differences of Brachial-Ankle Pulse Wave Velocity (baPWV), Body Composition and Cardiovascular Variables between Genders Who Have Been Exercised or Not in Elderly (운동참여 여부와 성별에 따른 노인의 맥박파전파속도, 신체구성과 심혈관계 변인의 상관성 및 재변인의 차이)

  • Lee, Jong-Woo;Kim, Dae-Sik;Cho, Eun-Kyung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.4
    • /
    • pp.378-387
    • /
    • 2016
  • This study sought to investigate interrelationships and differences of brachial-ankle pulse wave velocity (baPWV), body composition and cardiovascular variables between genders who have been exercised or not in elderly. One hundred fifty participants were classified four groups. Especially out of variables, in male elderly group who had participated in exercise program the PWV range were significantly correlated with muscle mass (r=0.357, p=0.026), SBP (r=0.468, p=0.003), right baPWV (r=0.406, p=0.010), and left baPWV (r=0.333, p=0.038). In male elderly group who had not participated in exercise program, the PWV range were significantly correlated with heart rate (r=0.395, p=0.014), right baPWV (r=0.598, p=0.000), and left baPWV (r=0.602, p=0.000). In female elderly group who had participated in exercise program, the PWV range were significantly correlated with name of diagnosis (r=0.321, p=0.044), SBP (r=0.399, p=0.011), DBP (r=0.545, p=0.000), right baPWV (r=0.648, p=0.000), and left baPWV (r=0.676, p=0.000). In female elderly group who had not participated in exercise program, the PWV range were significantly correlated with age (r=0.471, p=0.003), right baPWV (r=0.836, p=0.000), and left baPWV (r=0.801, p=0.000). The PWV among four groups were not significant different after experiment. However, there were significant differences in the waist/hip ratio (F=9.197, p=0.000), muscle mass (F=74.295, p=0.000), and %fat (F=35.045, p=0.000) from body composition. And there were significant differences in the SBP (F=3.525, p=0.017) after experiment. In conclusion, these data show that regular exercise is associated with arterial compliance (PWV range, right or left PWV) and differed from genders. In other words, this paper may support the concept that regular exercise program may exert a protective effect on arterial compliance, body composition and cardiovascular systems.

First Successful Dynamic Cardiomyoplasty in Korea (심근 성형술 1례 보고)

  • ;;;;;;;;Igor Dubrovski, Ph.D.
    • Journal of Chest Surgery
    • /
    • v.31 no.4
    • /
    • pp.393-397
    • /
    • 1998
  • A 25-year-old man with viral cardiomyopathy and chronic active hepatitis successfully underwent dynamic cardiomyoplasty for the first time in Korea on July 30, 1996. The patient had been intermittently dyspneic for 5 years and was admitted to our center twice because of heart failure. For the past 2 years, he was NYHA functional class III status with a left ventricular ejection fraction(LVEF) of around 30%. The patient was born with scoliosis and showed a short stature. The liver function showed elevated liver enzymes, and hepatitis B antigen was positive. The liver biopsy revealed chronic active hepatitis. The preoperative echocardiogram showed decreased left ventricular function with grade II mitral and grade II tricuspid regurgitation with dilated left and right atrium. Recently his symptoms worsened and we decided to perform a dynamic cardiomyoplasty. The left latissmus dorsi muscle(LDM) was mobilized and tested with lead placement on his right lateral decubitus position. The patient was positioned into supine and, after median sternotomy, the heart was wrapped with the mobilized muscle. The Russian made cardiomyostimulator(EKS-445) and leads (Myocardial PEMB for heart and PEMP-1 for LDM) were used. The total operation time was 8 hours and there were no perioperative episodes. Postoperatively the LDM had been trained for a 10 week period and currently the stimulation ratio is maintained at 1:4. The postoperative LVEF did not increase with the value of 30-35%. However, the patient feels better postoperatively with slightly increased activity.

  • PDF

Optical Principles of Beam Splitters

  • Lee, Chang-Kyung
    • Korean Journal of Geomatics
    • /
    • v.1 no.1
    • /
    • pp.69-74
    • /
    • 2001
  • In conventional photogrammetry, three-dimensional coordinates are obtained from two consecutive images of a stationary object photographed from two exposure stations, separated by a certain distance. However, it is impossible to photograph moving objects from two stations with one camera at the same time. Various methods to overcome this obstacle were devised e. g. taking the left and right scenes simultaneously with one camera using a beam splitter attached to the front, thus creating a stereo scene in one image. A beam splitter consists of two outer mirrors and two inner mirrors. This paper deals with research where the optical principles of the beam splitter were evaluated based on light path phenomena between the outer mirrors and the inner mirrors. A mathematical model of the geometric configuration was derived for the beam splitter. This allows us to design and control a beam splitter to obtain maximum scale and maximum base-height ratio by stepwise application of the mathematical model. The results show that the beam splitter is a very useful tool for stereophotography with one camera. The optimum geometric configurations ensuring maximum scale and base-height ratio are closely related to inner and outer reflector sizes, their inclination angles and the offsets between the outer mirrors.

  • PDF