• 제목/요약/키워드: Left heart failure

검색결과 303건 처리시간 0.02초

심실의 부하감소 측면에서 좌심실 보조장치의 최적 치료시기 예측을 위한 시뮬레이션 연구 (Prediction of Pumping Efficacy of Left Ventricular Assist Device according to the Severity of Heart Failure: Simulation Study)

  • 김은혜;임기무
    • 한국기계가공학회지
    • /
    • 제12권4호
    • /
    • pp.22-28
    • /
    • 2013
  • It is important to begin left ventricular assist device (LVAD) treatment at appropriate time for heart failure patients who expect cardiac recovery after the therapy. In order to predict the optimal timing of LVAD implantation, we predicted pumping efficacy of LVAD according to the severity of heart failure theoretically. We used LVAD-implanted cardiovascular system model which consist of 8 Windkessel compartments for the simulation study. The time-varying compliance theory was used to simulate ventricular pumping function in the model. The ventricular systolic dysfunction was implemented by increasing the end-systolic ventricular compliance. Using the mathematical model, we predicted cardiac responses such as left ventricular peak pressure, cardiac output, ejection fraction, and stroke work according to the severity of ventricular systolic dysfunction under the treatments of continuous and pulsatile LVAD. Left ventricular peak pressure, which indicates the ventricular loading condition, decreased maximally at the 1st level heart-failure under pulsatile LVAD therapy and 2nd level heart-failure under continuous LVAD therapy. We conclude that optimal timing for pulsatile LVAD treatment is 1st level heart-failure and for continuous LVAD treatment is 2nd level heart-failure when considering LVAD treatment as "bridge to recovery".

개심술시 병발한 좌심실 기능부전에 대한 Partial Left Heart Bypass 치험 (Partial Left Heart Bypass for Perioperative Left Ventricular Failure [A Report of 2 Clinical Cases])

  • 이종국
    • Journal of Chest Surgery
    • /
    • 제18권2호
    • /
    • pp.193-204
    • /
    • 1985
  • During the period from February to March, 1984, we employed a partial left heart bypass [left atrium to ascending aorta] in 2 patients who could not weaned from cardiopulmonary bypass with inotropic agents and cardiac pacing after coronary bypass surgery. These two patients showed significant improvement in ventricular function 18 to 47 hours after inserting the left heart bypass and were able to wean from the left heart bypass under using inotropic agents. Two patients died of multiple organ failures 11 days and 15 days postoperatively. These results indicate that early institution of left heart bypass in ventricular failure patients after open heart surgery can provide satisfactory long-term result.

  • PDF

The medical management of mitral stenosis in a Bull Terrier

  • Kun Ho Song;Aleksandra Domanjko Petric
    • 한국동물위생학회지
    • /
    • 제46권1호
    • /
    • pp.75-79
    • /
    • 2023
  • An eight-year-old, 28-kg male bull terrier who showed signs of lethargy and cough was referred for further evaluation of congestive heart failure. On presentation, physical examination revealed a systolic murmur at the left apex of the heart. Moreover, chest radiograph evaluation confirmed the mild alveolar and interstitial patterns in the caudal lung lobes and a grossly enlarged left atrium and left ventricle. Electrocardiography showed atrial fibrillation with a wide QRS complex, and transthoracic echocardiography revealed marked enlargement of the left atrium with abnormal morphology of the mitral valve. The thickened, hammer-like appearance and abnormal diastolic motion of the mitral valve leaflets were characterized by decreased leaflet separation and doming of the valve. The diagnosis was mitral stenosis with congestive heart failure and atrial fibrillation. The owner declined interventional valvuloplasty. Medical treatment included furosemide, pimobendan and diltiazem. Regular health check-ups have shown that vitality and clinical signs have improved considerably, and the dog have remained stable for 6 months after the presentation.

호흡곤란을 주소로 내원한 환자에서 혈청 B-type Natriuretic Peptide 검사의 유용성 : 폐성심과 좌심부전의 감별에 대하여 (The Application of B-Type Natriuretic Peptide Level of the Dyspneic Patients : Differentiation Between Cor Pulmonale and Left Ventricular Dysfunction)

  • 박홍훈;김세현;최정은;김강호;천석철;이지현;이용구;김인재;차동훈;홍상범;이지현
    • Tuberculosis and Respiratory Diseases
    • /
    • 제54권3호
    • /
    • pp.320-329
    • /
    • 2003
  • 연구배경 : 혈청 내 B-type natriuretic peptide (BNP)는 심실의 부피 증가나 압력 부하에 의해 주로 심실에서 분비된다. 몇몇의 보고에서 호흡곤란을 주소로 응급실에 내원한 환자들에서 BNP의 측정이 심부전과 폐질환을 감별하는데 도움이 된다고 보고하였다. 저자들은 호흡곤란을 주소로 내원한 환자에서 BNP의 측정이 우심실부전과 좌심실부전의 감별에 도움이 될 수 있는지를 알고자 이 연구를 시작하게 되었다. 방 법 : 포천중문의대 분당차 병원에 2002년 6월에서 2003년 3월까지 호흡곤란을 주소로 응급실을 내원한 환자 89명과, 정상 대조군으로 29명에서 방사선면역측정법을 이용하여 BNP를 측정하였다. 결 과 : 호흡곤란을 주소로 내원한 좌심실부전군(1군)과 우심실부전군(2군) 사이에는 유의한 BNP 값의 차이($682{\pm}314$ pg/mL vs. $149{\pm}94$ pg/mL, p=0.000)가 있었다. ROC 곡선을 이용하여 BNP 기준값을 219 pg/mL로 했을 때 좌심실부전군과 우심실부전군을 감별할 수 있는 민감도는 94.3%, 특이도는 92.9%, 양성 예측도는 97%, 그리고 음성 예측도는 86.7%였다. 결 론 : BNP는 호흡곤란을 주소로 응급실을 내원한 환자에서 좌심실부전과 우심실부전을 감별하는데 도움을 줄 수 있는 빠르고 유용한 검사방법이다.

Temporary Right Ventricular Assist Device Insertion via Left Thoracotomy after Left Ventricular Assist Device Implantation

  • Park, Ilkun;Cho, Yang Hyun;Chung, Su Ryeun;Jeong, Dong Seop;Sung, Kiick;Kim, Wook Sung;Lee, Young Tak
    • Journal of Chest Surgery
    • /
    • 제52권2호
    • /
    • pp.105-108
    • /
    • 2019
  • Right heart failure is a relatively common complication after left ventricular assist device (LVAD) implantation. Severe right heart failure can be managed by temporary right ventricular assist device (RVAD) implantation. However, trans-sternal RVAD insertion requires a subsequent third sternotomy for cannula removal. Herein, we present a case of RVAD insertion via a left anterior mini-thoracotomy after LVAD implantation in a patient with alcohol-induced cardiomyopathy.

Recovery of complete left bundle branch block in dilated cardiomyopathy after optimal heart failure treatment: a case report

  • Geum Ko;Jae-Geun Lee
    • Journal of Medicine and Life Science
    • /
    • 제21권3호
    • /
    • pp.112-116
    • /
    • 2024
  • Complete left bundle branch block (CLBBB) is a significant cardiac conduction abnormality often associated with dilated cardiomyopathy (DCM). This case report highlights the improvement in CLBBB and symptom relief through reverse cardiac remodeling in a patient diagnosed with DCM following an optimized heart failure treatment regimen consisting of an angiotensin-converting enzyme inhibitor, beta-blocker, and mineralocorticoid receptor antagonist. This case highlights the potential of electrical remodeling and conduction system improvement in patients with DCM receiving optimized medical therapy.

Cardiac Resynchronization Therapy Defibrillator Treatment in a Child with Heart Failure and Ventricular Arrhythmia

  • Kim, Hak Ju;Cho, Sungkyu;Kim, Woong-Han
    • Journal of Chest Surgery
    • /
    • 제49권4호
    • /
    • pp.292-294
    • /
    • 2016
  • Cardiac resynchronization therapy (CRT) is a new treatment for refractory heart failure. However, most patients with heart failure treated with CRT are adults, middle-aged or older with idiopathic or ischemic dilated cardiomyopathy. We treated a 12-year-old boy, who was transferred after cardiac arrest, with dilated cardiomyopathy, left bundle-branch block, and ventricular tachycardia. We performed cardiac resynchronization therapy with a defibrillator (CRT-D). After CRT-D, left ventricular ejection fraction improved from 22% to 4 4% assessed by echocardiogram 1 year postoperatively. On electrocardiogram, QRS duration was shortened from 206 to 144 ms. The patient's clinical symptoms also improved. For pediatric patients with refractory heart failure and ventricular arrhythmia, CRT-D could be indicated as an effective therapeutic option.

송아지에 이식한 공기구동형 인공심장의 혈역학적 연구 (Hemodynamic study of Pneumatic Artificial Heart Implanted in Calves)

  • 박표원
    • Journal of Chest Surgery
    • /
    • 제23권3호
    • /
    • pp.438-451
    • /
    • 1990
  • Pneumatic total artificial heart[TAH] has been clinically applied for the purpose of permanent or temporary use followed by cardiac transplantation in the patients with end stage heart diseases. In spite of the good durability of the pneumatic TAH, thrombus formation, bleeding and infection resulted in death. The Tomasu heart, which is a type of pneumatic TAH, was used in this study. This model is a modified Jarvik heart and consists of atrial cuffs, outflow vascular grafts and thin-layer seamless diaphragm type of ventricles. Cardiac outputs of the left artificial heart were measured by Donovan`s mock circulation under variable conditions of driving parameters, and an experimental artificial heart implantation was performed in 4 calves to observe the changes of hemodynamic parameters in early postoperative period and hematologic and bio-chemical changes in a long-term survival case. In the mock circulation test, cardiac output of the heart was increased with the increase of the left atrial pressure and left driving pressure. Maximum cardiac output was obtained at the heart rate of 120 to 130/min and percent systole of 40 to 45Zo under the condition of a constant left driving pressure of 180mmHg and left atrial pressure of 10mmHg. During the first 24 hours of TAH pumping, driving pressure ranged from 178$\pm$5mmHg to 187$\pm$8mmHg for the left heart and from 58$\pm$6mmHg to 78$\pm$28mmHg for the right heart. The Mean arterial pressure significantly increased between 2 and 8 hours after the start of pumping. The survival time ranged from 27 hours to 46 days. The causes of death were respiratory failure in 2 cases, mechanical valve failure in one, and left ventricular outflow obstruction due to thrombus in a 46-day survival case. This study demonstrated that Tomasu artificial heart operated effectively during the first 24 hours of artificial heart pumping, but thrombus formation around the valve holding area was the main problem in long-term survival case.

  • PDF

좌심실 부전증에서의 IABP 치험 - 5예 보고- (Intra-Aortic Balloon Pump in the Left Heart Failure)

  • 소동문
    • Journal of Chest Surgery
    • /
    • 제21권1호
    • /
    • pp.116-120
    • /
    • 1988
  • From July 1986 to June 1987, five patients were underwent IABP [intra aortic balloon pulsation] because of sever left heart failure in spite of maximum medication. These patients were reviewed as prophylactic IABP [1 patient], During operation [3 patients] and postoperative IABP [1 patients]. All patients were showed stable hemodynamic status with improved LV function during and after IABP. there was no IABP related complication or mortality. Advanced disease needs more effective methods of mechanical circulatory assistance and heart replacement.

  • PDF

개에서 대동맥판막협착에 의한 좌심부전 증례 (A Report of Left Heart Failure by Aortic Valvular Stenosis in a Mongrel Dog)

  • 김관우;황순신;김방실;김유정;조경오;오기석;김종택;박인철;손창호
    • 한국임상수의학회지
    • /
    • 제21권1호
    • /
    • pp.83-86
    • /
    • 2004
  • A 4 year old mixed female dog was presented dyspnea, anorexia and syncope. In blood smear test, a lot of heartworm larvae were observed. In thoracic radiography, "reverse D" shape was observed. So, this case was considered with heartworm disease. In echocardiography, marked left heart hypertrophy was presented. In M-mode view, aortic valvular stenosis was found. After mongrel dog died, aortic valvular stenosis was reconfirmed in necropsy. After all, the dog died of pulmonary edema because of aortic valvular stenosis caused left heart failure.t failure.