• Title/Summary/Keyword: Left atrial mechanical function

Search Result 5, Processing Time 0.075 seconds

Change of the Left Atrial Dimension and Transport Function after the Cox-Maze Procedure for Treating Atrial Fibrillation Associated with Mitral Valve Disease: the Short-term and Mid-Term Results (승모판막 질환과 동반된 심방세동에 대한 Cox-Maze 술식 후 좌심방 크기 및 기계적 수축력 변화: 중.단기 경과 관찰 분석)

  • Kim, Hwan-Wook;Lee, Jae-Won;Cho, Won-Chul;Jung, Sung-Ho;Choo, Suk-Jung;Song, Hyun;Chung, Cheol-Hyun
    • Journal of Chest Surgery
    • /
    • v.42 no.3
    • /
    • pp.317-323
    • /
    • 2009
  • Background: Although high efficiency of conversion into sinus rhythm has been demonstrated after performing the Cox-Maze procedure in patients with atrial fibrillation associated with mitral valve disease, the changes in the mechanical function and size of the left atrium have not been determined. The aim of the study was to evaluate the effect of the Maze procedure on the left atrial size and contractile transport function. Material and Method: From July 1997 to July 2008, 647 consecutive patients were operated on for chronic atrial fibrillation associated with mitral valve disease. Among these, 211 patients that (1) were able to be followed up for 2 years after surgery, (2) had sustained normal sinus rhythm, regardless of whether they were taking anti-arrhythmic medications and (3) did not have valvular regurgitation greater than grade III or they did not have moderate grade valvular stenosis were selected for evaluation. The left atrial size and contractile transport function were assessed by transthoracic echocardiography at the postoperative base line (1 year) and at regular follow-up periods (2 years, 3 years, 4 years and 6 year). Result: The left atrial dimension was increased and the contractile transport function was decreased during the follow-up period. The longer the follow-up period, the greater was the statistical significance of the left atrial size increase and contractile transport function decrease. Conclusion: In patients who sustain normal sinus rhythm conversion after a Maze III procedure with a mitral valve operation, there is a gradual increase of the left atrial dimensions and a decrease of contractile transport function during the follow-up period. Therefore, scrupulous follow-up is needed for these patients.

Is It Safe to Preserve Left Atrial Appendage During Maze Procedure?

  • Kyungsub Song;Woo Sung Jang;Namhee Park;Yun Seok Kim;Jae Bum Kim
    • Korean Circulation Journal
    • /
    • v.53 no.8
    • /
    • pp.566-577
    • /
    • 2023
  • Background and Objectives: The left atrial appendage (LAA) can contribute significantly to LA mechanical contraction. Nevertheless, the preventive effect of LAA occlusion during the maze procedure against cerebral infarction remains controversial. In this study, we compared the surgical, cardiac hemodynamic, and neurologic outcomes between LAA preservation and occlusion performed during the maze procedure. Methods: Between January 2015 and August 2021, 252 patients underwent the maze procedure using cryoablation at our medical center. After excluding patients according to our exclusion criteria (i.e., mechanical prosthesis implantation, preexisting LAA thrombus), LAA was preserved in 113 patients (non-occlusion group) and occluded in 75 patients (occlusion group). Outcomes were compared using propensity score matching (PSM). Results: PSM did not reveal significant intergroup differences in baseline characteristics between the non-occlusion (n=53) and occlusion (n=53) groups. During a median follow-up of 44 months, 2 patients in the non-occlusion group (3.8%) experienced ischemic strokes. There was no significant difference in the rate of freedom from stroke (p=0.19) and major adverse cardiac events (p=0.43) between the 2 groups. Through echocardiography at 1-year follow-up, a statistically significant difference in LA mechanical contraction was observed between the non-occlusion group and occlusion group (24 of 33 [72.7%] vs. 18 of 37 [48.6%], respectively; p=0.04). Conclusions: In this study, preservation of the LAA during the maze procedure resulted in better LA function than LAA occlusion, with similar rates of stroke.

Development and in Vivo Test of an Electrohydraulic Total Artificial Heart at the National Cardiovascular Center in Japan (일본 국립 순환기 센타형 전기유압식 인공심장의 개발과 동물실험)

  • 손영상
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.2
    • /
    • pp.163-170
    • /
    • 1998
  • The ultimate goal of total artificial heart is permanent substitute for a failed heart in a patient without any other therapeutic modality. Until now, infection has been the main problem related to the mechanical circulatory support system. The best way to solve this catastrophic complication and to improve the quality of life of TAH patients in terms of tethering must be implantation of TAH totally. The EH-TAH has been developed in NCVC from 1987 for this purpose. The system consists of an energy converter and pumps, which are designed to be placed in abdomen and pericardial space separately for a good anatomical fit. To evaluate the anatomical fit and hemodynamic performance of the EH-TAH, in vivo test was done. General condition of the animal and hemodynamic status had been stable until the TAH stopped on the 11th pumping day. The estimated cardiac output was about 7.7L/min. The values of mean aortic pressure, left and right atrial pressure were 93$\pm$10, 19$\pm$3 and 15$\pm$4 mmHg, respectively. The correlation coefficient between left and right atrial pressure was 0.96, which represents the dynamic function of the interatrial shunt in controlling left-right imbalance of cardiac output. During pumping days, the temperature on the surface of actuator had been maintained at 39.7$\pm$0.4$^{\circ}C$, less than 1$^{\circ}C$ higher than the rectal temperature. The TAH stopped on the 11th day due to mechanical problems. We concluded that the EH-TAH possessed satisfactory basic performance including anatomic fit and hemodynamic adequacy, although there were several mechanical problems to be solved yet.

  • PDF

Postoperative Transesophageal Echocardiographic Evaluation in Patients with Cardiac Valve Replacement (경식도 심초음파 검사를 이용한 판막대치술 환자의 평가)

  • 조건현
    • Journal of Chest Surgery
    • /
    • v.24 no.3
    • /
    • pp.265-270
    • /
    • 1991
  • Since advent of the prosthetic cardiac valve replacement, much efforts for accurate assessing value function in-vivo have been attempted. To evaluate the postoperative functional and morphological status of the replaced cardiac valve prosthesis, 33 patients with valve replacement were studied by transthoracic and transesophageal 2-dimensional echocardiac imaging as well as by color Doppler flow velocity imaging. Twenty four patients had mitral valve replacement. 6 patients had aortic valve replacement and 3 patients had both mitral and aortic valve replacement. There were 34 mechanical and 2 biological prosthesis. Comparing to transthoracic echocardiography, transesophageal approach showed transvalvular regurgitant jet flow amid the prosthetic mitral valve ring during. systole and much clear visualization of cardiac chamber behind prosthesis which could give shadowing effect to ultrasound beam. According to the quantitative grading by the length and area of mitral regurgitant flow, 24 out of 27 mitral valves revealed mild degree regurgitation considered as physiological after prosthetic bileaflet valve replacement and the other 3 valves including 2 biological prosthesis had moderate degree regurgitation which was regarded as pathologic one. 2 cases of left atrial thromboses and 1 case of paravalvular leakage which were not visible by transthoracic approach were identified by transesophageal echocardiography in patients with mitral valve replacement and patients with aortic valve replacement respectively. We conclude that in patients with prosthetic mitral valve replacement, transesophageal 2-dimensional imaging with color Doppler can suggest reliable information beyond that available from the transthoracic access even though it gives patient some discomfort to proceed.

  • PDF

Respiratory Assist by Use of Electrical Diaphragmatic Pacing (전기자극에 의한 횡격막 조율을 이용한 호흡보조장치)

  • 오중환;김은기;서재정;박일환;김부연;이상헌;이종국;이영희
    • Journal of Chest Surgery
    • /
    • v.34 no.6
    • /
    • pp.441-446
    • /
    • 2001
  • Background: Electrical breathing pacing has many advantages over mechanical ventilation. However, clinically permanent diaphragmatic pacing has been applied to limited patients and few temporary pacing has been reported. Our purpose is to investigate the feasibility of temporary electrical diaphragm pacing in explothoracotomy canine cases. Methods: Five dogs were studied under the general anesthesia. Left 5th intercostal space was opened. Self designed temporary pacing leads were placed around the left phrenic nerve and connected to the myostimulator. Chest wall was closed after tube insertion with underwater drainage. Millar catheter was introduced to the aorta and right atrium. Swan-Ganz catheter was introduced to the pulmonary artery. When the self respiration was shallow with deep anesthesia, hemodynamic and tidal volume were measured with the stimulator on. Results: Tidal volume increased from 143.3$\pm$51.3 ml to 272.3$\pm$87.4 ml(p=0.004). Right atrial diastolic pressure decreased from 0.7$\pm$4.0 mmHg to -10.5$\pm$4.7 mmHg(p=0.005). Pulmonary arterial diastolic pressure decreased from 6.1+2.5 mmHg to 1.2$\pm$4.8 mmHg(p<0.001). The height of water level in chest tube to show intrathoracic pressure change was from 10.3$\pm$6.7cmH$_{2}$O to 20.0$\pm$5.3 cmH$_{2}$O. Conclusion: Temporary electrical diaphragmatic pacing is a simple method to assist respiration in explothoracotomy canine cases. Self designed pacing lead is implantable and removable. Negative pressure ventilation has favorable effects on the circulatory system. Therefore, clinical application of temporary breathing pacing is feasible in thoracotomy patients to assist cardiorespiratory function.

  • PDF