• 제목/요약/키워드: Least Suare Method

검색결과 1건 처리시간 0.019초

IV 방법을 이용한 잡음이 포함된 베어링 실험 장치의 동특성 파라미터 추출 (An Application of the Instrumental Variable Method(IVM) to a Parameter Identification of a Noise Contaminated Bearing Test Rig)

  • 이용복;김창호;최동훈
    • 소음진동
    • /
    • 제6권5호
    • /
    • pp.679-684
    • /
    • 1996
  • The Instrumental Variable Method(IVM), modified from least square algorithm, is applied to parameter identification of a noise contaminated bearing test rig. The signal to noise ratio included in Frequency Response Function(FRF) can cause significant errors in parameter identification. Therefore, among several candidates of parameter identification method, results of the applied IVM were compared with noise-contaminated least square method. This study shows that the noise-contaminated least square method can have indonsistent accuracy depending on the degree of noise level, while the IVM has robuster performance to signal to noise ratio than least square method.

  • PDF