• 제목/요약/키워드: Leakage reduction

검색결과 478건 처리시간 0.024초

지방중소도시의 누수관리방법에 대한 효율성 평가 (Efficiency evaluation of water leakage management methods in local small and medium cities)

  • 황진수;최태호;김기범;구자용
    • 상하수도학회지
    • /
    • 제35권2호
    • /
    • pp.121-133
    • /
    • 2021
  • This study set up the estimates of leakage management efficiency evaluation and leakage management goal that could be used in local water distribution networks efficiency business and modernization business. The data were analyzed using data envelopment analysis and multiple regression analysis. To this end, with leakage management input indices concerning leakage reduction activities (e.g., aged pipe replacement, water meter replacement, leakage restoration, and leakage detection) and leakage management calculation indices (e.g., the increase of revenue water ratio and the reduction of leakage ratio), the data on 22 K-water consignment local water supply systems were analyzed for the years from 2004 through 2018. Using the results of efficiency analysis by data envelopment analysis, the other DMUs (Decision Making Unit) benchmarked the DMU with the highest efficiency to maximize the leakage management efficiency for all DMUs. Through this, leakage management goal estimates were drawn with the input indices of four leakage reduction activities and calculation indices of the increase of revenue water ratio and the reduction of leakage ratio by multiple regression analysis for each group based on the revenue water ratio and leakage ratio. The correlation coefficients of the leakage management goal estimate for the criteria for the revenue water ratio amounted to 0.553 and 0.771. The correlation coefficients of the leakage management goal estimate for the criteria for leakage ratio were 0.397 and 0.865. Accordingly, we estimated the quantity and priority of four leakage reduction activities for the target leakage ratio and revenue water ratio.

수치계산에 의한 축류터보기계의 유동장과 유동온실의 평가 III [회전차 익말단의 누설손실과 효율저하에 대한 평가] (Evaluation of Flowfield and Flow Losses insied Axial Turbomachinery Using Numerical Calculation [Evaluation of Tip Leakage Loss and Reduction of Efficiency by Tip Clearance])

  • 노수혁;조강래
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1998년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.240-247
    • /
    • 1998
  • Leakage vortices formed near blade tip causes an increase of total pressure loss near casing endwall region and as a result, the efficiency of rotor decreases. The reduction of rotor efficiency is related to the size of tip clearance. In this study, the three-dimensional flowfields in an axial flow rotor were calculated with varying tip clearance under various flow rates, and the numerical results were compared with experimental ones. The effects of tip clearance and attack angle on the leakage vortex and overall performance, and the less distributions were investigated through numerical calculations. In this study, tip leakage flow rate and total pressure loss by tip clearance were evaluated using numerical results and aprroximate equations were presented to evaluate the reduction of rotor efficiency by tip leakage flow.

  • PDF

수치계산에 의한 축류터보기계의 회전차 익말단의 누설손실과 효율저하에 대한 평가 (Evaluation of Tip Leakage Loss and Reduction of Efficiency of Axial Turbomachinery Using Numerical Calculation)

  • 노수혁;조강래
    • 한국유체기계학회 논문집
    • /
    • 제2권1호
    • /
    • pp.73-80
    • /
    • 1999
  • Leakage vortices formed new blade tip causes an increase of total pressure loss near the casing endwall region and as a result, the efficiency of rotor decreases. The reduction of rotor efficiency is related to the size of the tip clearance. In this study, the three-dimensional flowfields in an axial flow rotor were calculated by varying the tip clearance under various flow rates, and the numerical results were compared with experimental ones. The effects of tip clearance and attack angle on the leakage vortex and overall performance, and the loss distributions were investigated through numerical calculations. In this study, tip leakage flow rate and total pressure loss by tip clearance were evaluated using numerical results and approximate equations were presented to evaluate the reduction of rotor efficiency by tip leakage flow.

  • PDF

Risk of Carbon Leakage and Border Carbon Adjustments under the Korean Emissions Trading Scheme

  • Oh, Kyungsoo
    • Journal of Korea Trade
    • /
    • 제26권2호
    • /
    • pp.45-64
    • /
    • 2022
  • Purpose - This paper examines South Korea's potential status as a carbon leakage country, and the level of risk posed by the Korean emissions trading scheme (ETS) for Korean industries. The economic effects of border carbon adjustments (BCAs) to protect energy-intensive Korean industries in the process of achieving the carbon reduction target by 2030 through the Korean ETS are also analyzed. Design/methodology - First, using the Korean Input-Output (IO) table, this paper calculates the balance of emissions embodied in trade (BEET) and the pollution terms of trade (PTT) to determine Korean industries' carbon leakage status. Analyses of the risk level posed by carbon reduction policy implementation in international trade are conducted for some sectors by applying the EU criteria. Second, using a computable general equilibrium (CGE) model, three BCA scenarios, exemption regulations (EXE), reimbursement (REB), and tariff reduction (TAR) to protect the energy-intensive industries under the Korean ETS are addressed. Compared to the baseline scenario of achieving carbon reduction targets by 2030, the effects of BCAs on welfare, carbon leakage, outputs, and trading are analyzed. Findings - As Korea's industrial structure has been transitioning from a carbon importing to a carbon leaking country. The results indicate that some industrial sectors could face the risk of losing international competitiveness due to the Korean ETS. South Korea's industries are basically exposed to risk of carbon leakage because most industries have a trade intensity higher than 30%. This could be interpreted as disproving vulnerability to carbon leakage. Although the petroleum and coal sector is not in carbon leakage, according to BEET and PTT, the Korean ETS exposes this sector to a high risk of carbon leakage. Non-metallic minerals and iron and steel sectors are also exposed to a high risk of carbon leakage due to the increased burden of carbon reduction costs embodied in the Korean ETS, despite relatively low levels of trade intensity. BCAs are demonstrated to have an influential role in protecting energy-intensive industries while achieving the carbon reduction target by 2030. The EXE scenario has the greatest impact on mitigation of welfare losses and carbon leakage, and the TAF scenario causes a disturbance in the international trade market because of the pricing adjustment system. In reality, the EXE scenario, which implies completely exempting energy-intensive industries, could be difficult to implement due to various practical constraints, such as equity and reduction targets and other industries; therefore, the REB scenario presents the most realistic approach and appears to have an effect that could compensate for the burden of economic activities and emissions regulations in these industries. Originality/value - This paper confirms the vulnerability of the Korean industrial the risk of carbon leakage, demonstrating that some industrial sectors could be exposed to losing international competitiveness by implementing carbon reduction policies such as the Korean ETS. The contribution of this paper is the identification of proposed approaches to protect Korean industries in the process of achieving the 2030 reduction target by analyzing the effects of BCA scenarios using a CGE model.

KTX 감속구동장치 수분유입 및 누유 방지를 위한 구조개선 (Improvement of Structure to Prevent Water Infiltration and oil leakage for Reduction Units of KTX)

  • 이민수;김용기
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.20-25
    • /
    • 2007
  • KTX is being operated on Kyung-Pu High Speed Railroad Line and Ho-Nam Railroad Line from April 2004. Reduction units is occurring water infiltration at heavy snow and oil leakage because of labyrinth structure. This paper describes design method and evaluation technology to improve structure to prevent water infiltration and oil leakage for reduction units of KTX. This reduction units need high power and high speed to run and they have to make optimal lubricant without change current interface.

  • PDF

축류 회전차 익말단 틈새유동에 대한 수치해석 (III) - 회전차 익말단의 누설손실과 효율저하에 대한 평가 - (Numerical Analysis on the Blade Tip Clearance Flow in the Axial Rotor (III) - Evaluation of Tip Leakage Loss and Reduction of Efficiency near Blade Tip Clearance Region of a Rotor -)

  • 노수혁;조강래
    • 대한기계학회논문집B
    • /
    • 제23권9호
    • /
    • pp.1113-1120
    • /
    • 1999
  • Leakage vortices fonned near the blade tip cause an increase of total pressure loss near the casing endwall region and as a result, the efficiency of rotor decreases. The reduction of rotor efficiency is related to the size of tip clearance. In this study, the three-dimensional flow fields in an axial flow rotor were calculated with varying tip clearance under various flow rates, and the numerical results were compared with experimental ones. The effects of tip clearance and the of attack on the leakage vortex and overall performance, and the los9 distributions were investigated through numerical calculations. In this study, tip leakage flow rate and total pressure loss due to the tip clearance were evaluated using numerical results and approximate equations were presented to evaluate the reduction of rotor efficiency due to the tip leakage flow.

제주시 상수도 관망 블록시스템 구축을 통한 누수 저감 (Leakage Reduction through Establishment of Block System in Jeju City)

  • 차준호;김진근
    • 상하수도학회지
    • /
    • 제26권5호
    • /
    • pp.693-703
    • /
    • 2012
  • Leakage in water supply system can cause water resources loss in addition to the water quality degradation. In this research, leakage reduction after establishment of a block system in the area with leakage rate of 69.0 % was investigated using EPANET simulation. The average water pressure for the research area was $5.17kgf/cm^2$ which was relatively high, and several sites were deviated from recommended water pressure ranges(i.e., 1.5 ~ $7.1kgf/cm^2$). However, the average water pressure in the area was reduced to 3.81 and $3.49kgf/cm^2$ after the introduction of block system with a water pressure relief valve(PRV) setting of 3.0 and $2.5kgf/cm^2$, respectively. Under the installation of a PRV with regulating pressure of $2.5kgf/cm^2$, the predicted leakage was reduced from $4,420.3m^3/d$ to $3,028.1m^3/d$, which was equivalent to the leakage reduction from 31.0 % to 23.5 %.

3레벨 태양광 PCS에서의 누설전류 저감기법 개발 (Development of Leakage Current Reduction Method in 3-Level Photovoltaic PCS)

  • 한성은;조종민;안현성;차한주
    • 전력전자학회논문지
    • /
    • 제24권1호
    • /
    • pp.56-61
    • /
    • 2019
  • In this study, a reduction method of leakage current in a three-level photovoltaic power-conditioning system (PCS) is proposed and verified by simulation and experiment. Leakage current generation is analyzed through an equivalent model of the common mode voltage considering a significant parasitic capacitance existing between the photovoltaic array and ground. A leakage current reduction method using pulse-width modulation (PWM) method is also proposed, and a 10-kW three-level photovoltaic PCS simulation and experiment is performed with a $1{\mu}F$ parasitic capacitor based on 100 nF/kW. The proposed method using the PWM method is verified to reduce the leakage current by 73% compared with the conventional PWM method.

An Advanced Embedded SRAM Cell with Expanded Read/Write Stability and Leakage Reduction

  • Chung, Yeon-Bae
    • 전기전자학회논문지
    • /
    • 제16권3호
    • /
    • pp.265-273
    • /
    • 2012
  • Data stability and leakage power dissipation have become a critical issue in scaled SRAM design. In this paper, an advanced 8T SRAM cell improving the read and write stability of data storage elements as well as reducing the leakage current in the idle mode is presented. During the read operation, the bit-cell keeps the noise-vulnerable data 'low' node voltage close to the ground level, and thus producing near-ideal voltage transfer characteristics essential for robust read functionality. In the write operation, a negative bias on the cell facilitates to change the contents of the bit. Unlike the conventional 6T cell, there is no conflicting read and write requirement on sizing the transistors. In the standby mode, the built-in stacked device in the 8T cell reduces the leakage current significantly. The 8T SRAM cell implemented in a 130 nm CMOS technology demonstrates almost 100 % higher read stability while bearing 20 % better write-ability at 1.2 V typical condition, and a reduction by 45 % in leakage power consumption compared to the standard 6T cell. The stability enhancement and leakage power reduction provided with the proposed bit-cell are confirmed under process, voltage and temperature variations.

누출이 헬름홀츠 공명기의 소음저감 특성에 미치는 영향 (Effect of Leakage on the Noise Reduction Characteristics of Helmholtz Resonator)

  • 이일재
    • 한국소음진동공학회논문집
    • /
    • 제19권6호
    • /
    • pp.634-640
    • /
    • 2009
  • Helmholtz resonator has been used, especially in intake and exhaust systems of vehicles, due to its good noise reduction characteristics at low frequencies. Many approaches have been developed to predict the acoustic behavior of the resonator with the assumption that there is no leakage from the resonator. However, its behavior may be affected by leakage which may exist in manufacturing processes or on purpose. This study investigates the effect of leakage on the noise reduction characteristics of Helmholtz resonator with two practical examples. One is a resonator with a gap between baffle and housing of the resonator and the other one is a resonator with two drain holes on the baffle. The measured transmission loss shows that the resonance frequencies are considerably shifted to higher frequency due to the leakage. The Boundary Element Method was applied to predict the transmission loss of the Helmholtz resonator with drain holes. The comparison between the measured and predicted transmission loss shows that the acoustic impedance of the holes is essential for accurate predictions of the transmission loss.