Performance Evaluation of an Electrometer for Quality Control and Dosimetry in Radiation Therapy (방사선 치료의 정도관리 및 선량측정에 이용되는 전리계의 성능평가)

  • Kim, Chang-Seon;Kim, Chul-Yong;Park, Myung-Sun
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.123-130
    • /
    • 2000
  • The performance of an electrometer directly affects on the accuracy and precision in radiation dosimetry. This study is to list of the quality control for maintaining performance and to perform evaluation tests of an electrometer. Performance tests selected include proper polarizing voltages, warm-up and equalization time, leakages, long-term stability, linearity, and effect of ambient conditions. An electrometer connected with a rigid stem ionization chamber was evaluated with a Strontium-90 check device. Bias voltage was measured directly on the input socket. Equalization time is the time required for reaching threshold of charged state after the power is on or the bias voltage is changed. Pre- and post-signal leakages are defined as the accumulation of signal with no exposure and after exposure, respectively. Over three months period, the electrometer's long-term stability was measured by comparison of the temperature-pressure corrected readings. Linearity was expressed as the deviation of readings from multiple short exposures from one continuous exposure. Effect of ambient conditions was expressed as the zero drift of the electrometer over 17-34$^{\circ}C$ temperature ranges. For two nominal values, 300 and 500 volts, measured voltages were lower by 2.5 and 5.8%, respectively. The warm-up time, 20 minutes, was longer than the lamp time by 9 minutes and the equalization time was less than 1 minute. Without exposure, the zero-drift was 0.002 scale-unit in 15 minutes and the leakage after 10 minutes exposure was minimal. The IQ-4 was stable over 99.4% for three-month periods. Deviation from the linearity was 0.9% for measurement scale, 0.000-9.991. Over 17-34$^{\circ}C$ temperature range, the zero-drift was minimal, less than 0.2%. For a clinically-used electrometer, a list for the basic peformance evaluations is proposed. By running this program, the measurement error using an electrometer can be reduced and in turn the improvement in accuracy and precision of radiation dosimetry can be achieved.

  • PDF

Ten Years Experiences of ATS Mechanical Valve (ATS 기계 판막의 10년 임상경험)

  • Yi, Gi-Jong;Bae, Mi-Kyung;Lim, Sang-Hyun;Yoo, Kyung-Jong;Chang, Byung-Chul;Hong, You-Sun
    • Journal of Chest Surgery
    • /
    • v.39 no.12 s.269
    • /
    • pp.891-899
    • /
    • 2006
  • Background: This study is to evaluate the safety of ATS valve by examining the clinical results of ten-years experience. Material and Method: From July 1995 to March 2005, we reviewed 305 patients with ATS valve implantation. Mean age was $49.8{\pm}11.7$ years and 140(45.6%) males were included. Etiologies were rheumatic diseases in 207 cases(67.4%), degenerative changes in 57 cases(18.6%), valve dysfunction in 23 cases(7.5%) and infective endocarditis in 14 cases(4.6%). AVR was performed in 72 patients(23.5%), MVR in 156 patients (50.8%), DVR(AVR+MVR) in 63 patients(20.5%) and TVR in 16 patients(5.2%). Result: There were 9 operative mortalities(2.9%). Follow up period was $56.5{\pm}34.0(0{\sim}115)$ months and 96.4% patients were followed up with 9 late deaths. Five and ten years survival rates were $94.9{\pm}1.3%,\;91.2{\pm}2.3%$ using Kaplan-Meier's methods. Valve related event free survival rates in 5 and 10 years were $90.8{\pm}2.0%$ and $86.9{\pm}3.2%$. There were 16 anticoagulation-related hemorrhages, 6 thromboembolisms, 3 prosthetic valve endocarditis and 1 paravalvular leakage. NYHA class improved after operation(p<0.05). Postoperative echocardiography showed significant decrease in LA size, LVEDD and IVESD(p<0.01). Patients with 19 and 21 mm valve showed significantly higher transvalvular pressure gradient in aortic position(p<0.001, p<0.001). Conclusion: ATS valve showed good hemodynamic results with few valve related complications and thus can be used with acceptable risk.

Construction and Tests of the Vacuum Pumping System for KSTAR Current Feeder System (KSTAR 전류전송계통 진공배기계 구축 및 시운전)

  • Woo, I.S.;Song, N.H.;Lee, Y.J.;Kwag, S.W.;Bang, E.N.;Lee, K.S.;Kim, J.S.;Jang, Y.B.;Park, H.T.;Hong, Jae-Sik;Park, Y.M.;Kim, Y.S.;Choi, C.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.6
    • /
    • pp.483-488
    • /
    • 2007
  • Current feeder system (CFS) for Korea superconducting tokamak advanced research(KSTAR) project plays a role to interconnect magnet power supply (MPS) and superconducting (SC) magnets through the normal bus-bar at the room temperature(300 K) environment and the SC bus-line at the low temperature (4.5 K) environment. It is divided by two systems, i.e., toroidal field system which operates at 35 kA DC currents and poloidal field system wherein 20$\sim$26 kA pulsed currents are applied during 350 s transient time. Aside from the vacuum system of main cryostat, an independent vacuum system was constructed for the CFS in which a roughing system is consisted by a rotary and a mechanical booster pump and a high vacuum system is developed by four cryo-pumps with one dry pump as a backing pump. A self interlock and its control system, and a supervisory interlock and its control system are also established for the operational reliability as well. The entire CFS was completely tested including the reliability of local/supervisory control/interlock, helium gas leakage, vacuum pressure, and so on.

Short Term Clinical Experiences of 52 Sorin Bicarbon Mechanical Valves (Sorin Bicarbon 기계판막의 단기 임상성적)

  • Lee, Cheol-Joo;Choi, Ho;Kim, Jung-Tai;Soh, Dong-Moon;Roh, Hwan-Kyu;Han, Jeong-Seon
    • Journal of Chest Surgery
    • /
    • v.31 no.7
    • /
    • pp.679-683
    • /
    • 1998
  • From June 1995 to May 1997, we have implanted 52 Sorin Bicarbon mechanical valves in 41 patients. They were 16 men and 25 women, and their mean age was 47.4${\pm}$14.8(range; 18∼74 y.o.). 35(27 mm∼31 mm) were in mitral position, 15(19 mm∼25 mm) in aortic position, and 2(31 mm) in tricuspid position. 3 CABGs and a tumor excision were taken concomittantly. 35 patients were primary operation, and 6 were re-do operations. By intraoperative transesophageal doppler echocardiography, transvalvular peak/mean pressure gradient was 6.1${\pm}$2.7/2.4${\pm}$1.4 mmHg in mitral position and 27.6/10.7 mmHg in aortic position. The effective valve opening area in mitral position was 3.2${\pm}$0.6 cm2. Follow-up was total 508.6 patient-months, and mean follw-up was 12.7${\pm}$9.2 months. NYHA class was improved from 2.6${\pm}$0.6 to 1.2${\pm}$0.3 in average postoperatively. During that period, there was no operative death. 2 late non-valve related deaths were occurred. One was died of COPD, and the other was possible acute myocardial infarction. Among 7 postoperative complications, one valve related complication(minimal paravalvular leakage) was noticed. In conclusion, Sorin Bicarbon mechanical valve is believed one of the safe choice in clinical settings. It showed excellent hemodynamic and mechanical functions, and very low postoperative valve related complications in short term clinical experience.

  • PDF

Study on the Consequence Effect Analysis & Process Hazard Review at Gas Release from Hydrogen Fluoride Storage Tank (최근 불산 저장탱크에서의 가스 누출시 공정위험 및 결과영향 분석)

  • Ko, JaeSun
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.4
    • /
    • pp.449-461
    • /
    • 2013
  • As the hydrofluoric acid leak in Gumi-si, Gyeongsangbuk-do or hydrochloric acid leak in Ulsan, Gyeongsangnam-do demonstrated, chemical related accidents are mostly caused by large amounts of volatile toxic substances leaking due to the damages of storage tank or pipe lines of transporter. Safety assessment is the most important concern because such toxic material accidents cause human and material damages to the environment and atmosphere of the surrounding area. Therefore, in this study, a hydrofluoric acid leaked from a storage tank was selected as the study example to simulate the leaked substance diffusing into the atmosphere and result analysis was performed through the numerical Analysis and diffusion simulation of ALOHA(Areal Location of Hazardous Atmospheres). the results of a qualitative evaluation of HAZOP (Hazard Operability)was looked at to find that the flange leak, operation delay due to leakage of the valve and the hose, and toxic gas leak were danger factors. Possibility of fire from temperature, pressure and corrosion, nitrogen supply overpressure and toxic leak from internal corrosion of tank or pipe joints were also found to be high. ALOHA resulting effects were a little different depending on the input data of Dense Gas Model, however, the wind direction and speed, rather than atmospheric stability, played bigger role. Higher wind speed affected the diffusion of contaminant. In term of the diffusion concentration, both liquid and gas leaks resulted in almost the same $LC_{50}$ and ALOHA AEGL-3(Acute Exposure Guidline Level) values. Each scenarios showed almost identical results in ALOHA model. Therefore, a buffer distance of toxic gas can be determined by comparing the numerical analysis and the diffusion concentration to the IDLH(Immediately Dangerous to Life and Health). Such study will help perform the risk assessment of toxic leak more efficiently and be utilized in establishing community emergency response system properly.

Characteristics of Seepage Water and Groundwater in a Coastal LPG Storage Cavern of Jeonnam (전남 해안 LPG 저장공동 유출수와 주변 지하수의 수질특성)

  • Lee, Jin-Yong;Choi, Mi-Jung;Kim, Hyun-Jung;Cho, Byung-Wook
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.4
    • /
    • pp.33-44
    • /
    • 2009
  • Water curtain of an underground LPG storage cavern is a facility to prevent leakage of high pressure gases, for which groundwater should flow freely towards the cavern and groundwater level also must be stably maintained. In this study, in order to evaluate qualities of seepage water and surrounding groundwater of an underground LPG storage cavern in Yeosu, 4 rounds of samplings, field measurements and laboratory analyses (February, May, August, October of 2007) were conducted. According to field measurements, pH was weak acidic to neutral but it gradually increased with time. Electrical conductivity (EC) of groundwater near a salt stack showed very high values between 10.47 and 38.50 mS/cm. Dissolved oxygen (DO) showed a very wide range of 0.20~8.74 mg/L and a mean of oxidation-reduction potential (ORP) was 159 mV, which indicated an oxidized condition. Levels of $Fe^{2+}$ and $Mn^{2+}$ were mostly less than 3 mg/L. All of seepage waters showed a Na-Cl type while only groundwater near the salt stack showed a Na-Cl type with a high total dissolved solid. The other groundwaters exhibited typical $Ca-HCO_3$ types. Levels of aerobic bacteria were mostly very high (573-39,520 CFU/mL). Based on the analyses of these hydrochemistry and biological characteristics, it is concluded that there are no particular problems in groundwater and seepage water, which not causing a trouble in the cavern operation. However, both for control of bio-clogging and for sustainable operation of the water curtain system, a regular hydrochemical and microbiological monitoring is required for the seepage water and surrounding groundwater.

Grouting Improvement through Correlation Analysis of Hydrogeology and Discontinuity Factors in a Jointed Rock-Mass (절리 암반의 수리지질 및 불연속면 특성 간 상관분석을 통한 그라우팅 계획 수립의 개선 방안)

  • Kwangmin Beck;Seonggan Jang;Seongwoo Jeong;Minjune Yang
    • The Journal of Engineering Geology
    • /
    • v.34 no.2
    • /
    • pp.279-294
    • /
    • 2024
  • Large-scale civil engineering structures such as dams require a systematic approach to jointed rock-mass grouting to prevent water leakage into the foundations and to ensure safe operation. In South Korea, rock grouting design often relies on the experience of field engineers that was gained in similar projects, highlighting the need for a more systematic and reliable approach. Rock-mass grouting is affected mainly by hydrogeology and the presence of discontinuities, involving factors such as the rock quality designation (RQD), joint spacing (Js), Lugeon value (Lu), and secondary permeability index (SPI). This study, based on data from field investigations of 14 domestic sites, analyzed the correlation between hydrogeological factors (Lu and SPI), discontinuity characteristics (RQD and Js), and grout take, and systematically established a design method for rock grouting. Analysis of correlation between the variables RQD, Js, Lu, and SPI yielded Pearson correlation (r) values as follows: Lu-SPI, 0.92; RQD-Lu, -0.75; RQD-Js, 0.69; RQD-SPI, -0.65; Js-Lu, -0.47; and SPI-Js, -0.41. The grout take increases with Lu and SPI values, but there is no significant correlation between RQD and Js. The proposed approach for grouting design based on SPI values was verified through analysis and comparison with actual curtain-grouting construction, and is expected to be useful in practical applications and future studies.

Early Clinical Experience in Aortic Valve Replacement Using On-X$^{circledR}$Prosthetic Heart Valve (On-X$^{circledR}$ 기계판막을 이용한 대동맥판 치환술의 조기 임상 경험)

  • 안병희;전준경;류상완;최용선;김병표;홍성범;박종춘;김상형
    • Journal of Chest Surgery
    • /
    • v.36 no.9
    • /
    • pp.651-658
    • /
    • 2003
  • Since the first implanted in September 1997, the use of On-X prosthetic heart valve has been increasing around in the world. This study was designed to assess the feasibility, safety, and the postoperative hemodynamics with this new valve in clinical setting. Material and Method: The current study was carried out on 52 patients undergoing aortic valve replacement with this prosthesis between April 1999 to August 2002 at Chonnam National University Hospital to evaluate the surgical results. 52% of the patients were male and the average age at implant was 50$\pm$13 years. The study followed the guidelines of the AATS/STS. Preoperatively, 32(61.5%) patients were in NYHA functional class III or IV and 2 patients had previous aortic valve surgery. Concomitant cardiac surgery was performed in 71.1%. The implanted valve sizes were 19 mm in 13 patients, 21 mm in 26, 23 mm in 10 and 25 mm in 3, respectively. Mean follow-up was 16.6$\pm$10.5 months (1∼39 months). Echocardiographic assessment was performed pre- and immediate postoperatively, as well as 3, 6, 12 months after surgery, evaluating pressure loss and regression of left ventricular hypertrophy. Result: Mean cardiopulmonary bypass time was 191$\pm$94.7 minutes with an aortic cross-clamp time of 142$\pm$51.7 minutes. There was no early and late mortality, Freedom from adverse events at 1 year in the study were as follows: thromboembolism, 95.6$\pm$6%; bleeding events, 90.2$\pm$4%; paravalvular leakage 92.3$\pm$4%; and overall valve-related morbidity at 1 year was 76.6$\pm$3%. There were no cases of valve thrombosis, prosthetic valve endocarditis and structural or non-structural failure. Left ventricular function at 12 months after surgery (EF=62.7$\pm$9.8%) revealed a statistically significant improvement compared to preoperative investigation (EF=55.8$\pm$15.9%, p=0.006). Left ventricular mass index was 247.3$\pm$122.3 g/$m^2$ on preoperative echocardiographic study, but regressed to 155.5$\pm$58.2 g/$m^2$ at postoperative 1 year (p=0.002). Over the follow-up period a further decrease of peak transvalvular gradients was observed in all patients: 62.5$\pm$38.0 mmHg on preoperative assessment, 18.2$\pm$6.8 mmHg at immediate postoperative period (p < 0.0001), 7.6$\pm$5.09 mmHg (p<0.0001) at 6 month, 18.0$\pm$10.8 mmHg (p<0.0001) at 1 year. Conclusion: The On-X prosthetic heart valve performs satisfactorily in the first 1 year period. Clinical outcome by examining NYHA functional classification revealed especially good results. Effective regression of left ventricular hypertrophy and statistically significant decrease of transvalvular gradient were observed over the first year, but longer-term follow-up of this patient group is needed to establish the expected rates for late valve-related events as well as the long-term clinical efficacy of this valve.