• Title/Summary/Keyword: Leakage monitoring

Search Result 321, Processing Time 0.037 seconds

The Diagnosis of Polymeric Insulation Materials for Outdoor in the Salt Fog (Salt fog 내에서 옥외용 고분자 절연물의 절연진단)

  • Moon, J.S.;Kim, J.H.;Lee, J.H.;Song, W.C.;Cho, H.G.;Yoo, Y.S.;Park, Y.G.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1569-1571
    • /
    • 2000
  • The ageing process was checked by leakage current monitoring in Salt Fog Method. In order to monitor leakage current, DAS with 12-bit, 8-channel A/D converter was prepared. The monitored components of leakage current were averages of the rms and peak, max peak, cumulative charge, and the cumulative number of peak pulses. The acquired data were stored to the disc periodically. And, surface conductivity was measured to investigate loss of hydrophobicity. The results suggest that surface conductivity and leakage current are well corresponding to initial loss of hydrophobicity.

  • PDF

Controller for Gas Leakage Protection in Semiconductor Process Chamber (반도체 제조장비용 챔버 가스누출 방지를 위한 제어모듈 개발)

  • Park Sung-Jin;Lee Eui-Yong;Sul Yong-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.6 no.5
    • /
    • pp.373-377
    • /
    • 2005
  • In this paper the gas leakage controller in processing chamber for semiconductor manufacturing is proposed. A pressure sensor is connected between the final valve and the numeric valve. A pressure sensor signal and a numeric valve signal are controlled by a proposed digital circuit module. Gas leakage condition, producing by 2nd plasticity in semiconductor process, display at LED. The proposed controller module is useful for monitoring the gas flow for preventing the critical process gas leakage.

  • PDF

Fiber-optic humidity sensor system for the monitoring and detection of coolant leakage in nuclear power plants

  • Kim, Hye Jin;Shin, Hyun Young;Pyeon, Cheol Ho;Kim, Sin;Lee, Bongsoo
    • Nuclear Engineering and Technology
    • /
    • v.52 no.8
    • /
    • pp.1689-1696
    • /
    • 2020
  • In this study, we developed a fiber-optic humidity sensor (FOHS) system for the monitoring and detection of coolant leakage in nuclear power plants. The FOHS system includes an FOHS, a spectrometer, a halogen white-light source, and a Y-coupler. The FOHS is composed of a humidity-sensing material, a metal tube, a multi-mode plastic optical fiber, and a subminiature version A (SMA) fiber-optic connector. The humidity-sensing material is synthesized from a mixture of polyvinylidene fluoride (PVDF) in dimethyl sulfoxide (DMSO) and hydroxyethyl cellulose (HEC) in distilled water. We measured the optical intensity of the light signals reflected from the FOHS placed inside the humidity chamber with relative humidity (RH) variation from 40 to 95%. We found that the optical intensity of the sensing probe increased linearly with the RH. The reversibility and reproducibility of the FOHS were also evaluated.

Development of Lightning Arrester Degradation Monitoring System Using ZCT (ZCT틀 이용한 피뢰기 열화 감시 시스템 개발)

  • Park, J.N.;Lee, Y.H.;Jang, S.H.;Kim, P.S.;Shin, Y.S.;Kim, Y.G.;Seo, J.M.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1626-1628
    • /
    • 2003
  • The lightning arrester is a very important overvoltage protection device in the electric power system. Therefore, the inspection of lightning arrester whether it keeps its performance or not properly has close related to verifying the safety confidence of the electric power system. But the development of the deterioration measuring method and on-line detecting system, is necessary to monitor the deterioration of the lightening arrestor. In this paper, we developed the lightning arrester degradation monitoring system. This system detected leakage current of lightning arrester by using the ZCT, and analyze the third harmonics ingredient of leakage current using DFT method in the Data Acquisition Unit(DAU). The analyzed current signal is transmit to the Human-Machine Interface(HMI), and HMI alarmed when accident are occurred and informed with the amplitude of leakage current to the operator.

  • PDF

Evaluation of Rail Leakage Current and Potential in DC Railway (직류철도의 레일누설전류 밑 전위평가)

  • Han, Moon-Seob;Jung, Ho-Sung;Kim, Ju-Rak;Kil, Gyung-Suk
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.1
    • /
    • pp.161-166
    • /
    • 2009
  • DC feeding system is mainly floating but rail potential and leakage current are due to long parallelism between rails and ground, namely rail resistance and rail to ground conductance. Rail potential causes electric shock to human and rail leakage current causes electrolytic corrosion to nearby the buried metals. Therefore the design technologies to reduce, protect and monitor these effects are important in recent DC feeding system. Rail potential and leakage current are analysed based on propagation theory that is utilized. Monitoring and controlling rail leakage current is proposed in order to maintain rail resistance and rail to ground conductance.

Application of electrical leakage detection method for waste landfill (매립지 누출위치 실시간 파악을 위한 전극검지법의 적용 사례)

  • Han, Sang-Jae;Kim, Byung-Il;Hong, Kang-Han;Jung, Jae-Hyun;Kim, Soo-Sam
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.798-804
    • /
    • 2009
  • Damaged liners may be detected by using leakage detection systems. For the reason, many types of leakage detection systems are applied to analyze or detect damages of lining system such as electrical detection method for the landfill sites. However, most of them can be applied in the new landfill construction sites because sensors should be installed in the bottom of liner systems. This paper shows a case study reviewing the development of a fence type leakage detection method, monitoring system and pilot plant test results, so that they can be economically and efficiently applied to actual used or in-use sites without a leakage detection system.

  • PDF

Development of Monitoring RF System on Leakage of Gas Cylinder in Gaseous Fire Extinguishing System (가스계 소화시스템용 소화약제 저장용기 누설 검출 무선 시스템 개발)

  • So, Soo-Hyun;Oh, Ju-Hwan;Cha, Cheol-Woong;Lee, Dae-Kuen
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.7-10
    • /
    • 2008
  • In our study, Monitoring RF System in real-time on leakage of gas cylinder is developed. The system is consisted of Pressure Transmitting part, Main Controller and Operating program. The pressure data of gas cylinder are transmitted to the modem of main controller part by RF module of Pressure Transmitting part and the data received through the modem are recorded in real-time and showed the situation of gas cylinder on the PC monitor. Through the test on the case of the artificial pressure-reduction, the detecting performance. of the developed system is conformed.

  • PDF

해안매립지에서의 추적자시험 및 수위변화특성 연구

  • 이진용;황대규;이명재;최예권;김정우;이강근
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.221-224
    • /
    • 2002
  • To demonstrate prevention of the leachate leakage out of the landfill with creating inward hydraulic gradient, a tracer test and continuous waterlevel monitoring at the Inside and outside of the barrier wall of a costal landfill were peformed. When the tracers were injected into the well outside of the vertical wall system with high water level, then they were detected at the well inside of the system with low water level. Furthermore the lowered water level at the inside of the landfill than that at the outside prevented leachate leakage out of the landfill. This study reports results of the tracer test and waterlevel monitoring.

  • PDF

Development of Expert System for the Fault Diagnosis of Chemical Facility System (화학설비 시스템의 이상고장진단을 위한 Expert System의 개발)

  • Oh, Jae-Eung;Shin Jun;Shin, Ki-Hong;Kim, Doo-Hwan;Kim, Woo-Taek;Lee, Chung-Hwi
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.05a
    • /
    • pp.639-642
    • /
    • 2000
  • Chemical facility system have dangerous elements that can injure the human like an explosion and a fire, gas poisoning by a leakage of the harmful chemical material. In addition to a vibration of the machine occurs the leakage. Therefore, the chemical factory requires for periodic monitoring of the vibration. But, until now, the operator has executed a monitoring of the machine by the senses. So, the diagnostic expert system by which the operator can judge easily and expertly a condition of the machine is developed. This paper describes the structure of diagnostic system and the diagnostic algorithm using fuzzy inference

  • PDF

Development of an Architecture Monitoring System Using Wireless Sensor Network (무선 센서네트워크를 이용한 건축물 모니터링 시스템 구현)

  • Chang, Hyung-Jun;Kim, Beom-Soo;Kong, Young-Bae;Park, Gwi-Tae;Shim, II-Joo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.6
    • /
    • pp.568-573
    • /
    • 2007
  • Environmental information (temperature, humidity, vibration, $CO_2$, gas leakage, etc.) of building is an essential item to manage and monitor a building. For intelligent building, it is necessary to get temperature and illumination information to save energy and crack information to prevent structural problems. Moreover, temperature and gas leakage information to alarm a tire precaution, or humidity information to maintain comfortable environment. However, there have not been many researches on systems for gathering environmental information and building maintenance due to high costs. In this paper, wireless sensor network technology is applied to collecting building environmental information. Wireless sensor network is one of the latest issues and has low-power consumption, low-cost, self-configuration features.