Proceedings of the Korean Geotechical Society Conference (한국지반공학회:학술대회논문집)
- 2009.03a
- /
- Pages.798-804
- /
- 2009
Application of electrical leakage detection method for waste landfill
매립지 누출위치 실시간 파악을 위한 전극검지법의 적용 사례
- Han, Sang-Jae (Research Institute, Expert Group for Earth and Environment) ;
- Kim, Byung-Il (Research Institute, Expert Group for Earth and Environment) ;
- Hong, Kang-Han (Research Institute, Expert Group for Earth and Environment) ;
- Jung, Jae-Hyun (Dept. of Technology Developement, Expert Group for Earth and Environment) ;
- Kim, Soo-Sam (Dept. of Civil and Environmental Eng., Hanyang Univ.)
- 한상재 ((주)지구환경전문가그룹/기술연구소) ;
- 김병일 ((주)지구환경전문가그룹/기술연구소) ;
- 홍강한 ((주)지구환경전문가그룹/기술연구소) ;
- 정재현 ((주)지구환경전문가그룹/기술부) ;
- 김수삼 (한양대학교 토목환경공학과)
- Published : 2009.03.27
Abstract
Damaged liners may be detected by using leakage detection systems. For the reason, many types of leakage detection systems are applied to analyze or detect damages of lining system such as electrical detection method for the landfill sites. However, most of them can be applied in the new landfill construction sites because sensors should be installed in the bottom of liner systems. This paper shows a case study reviewing the development of a fence type leakage detection method, monitoring system and pilot plant test results, so that they can be economically and efficiently applied to actual used or in-use sites without a leakage detection system.