• 제목/요약/키워드: Leakage inductance

검색결과 242건 처리시간 0.023초

고주파 트랜스포머의 권선배열에 기법 따른 손실해석 (Power Loss Analysis according to Winding Array Method of High Frequency Transformer)

  • 윤신용;김일남
    • 전기학회논문지P
    • /
    • 제54권1호
    • /
    • pp.15-19
    • /
    • 2005
  • This paper analyzed the power loss characteristics according to winding thickness and winding method of high frequency transformer. Power loss was analyzed by PExprt using FEM tool. The ferrite core model for analysis be used the EE10 type of TDK cop.. Transformer model objected flyback transformer type applied to flyback converter/inverter. Therefore, analysis results of loss were obtained from inner parameters of DC, AC resistance, leakage inductance, copper loss, core loss, and temperature etc.

능동 클램프 모드로 동작하는 단일 전력 AC/DC 컨버터에 의한 역률개선 (Power Factor with Single Power Stage AC/DC Converter Operated in Active-Clamp Mode)

  • 윤신용;백수현;김용;김철진;어창진
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권8호
    • /
    • pp.392-401
    • /
    • 2001
  • This paper presents the single-stage high power factor AC to DC converter operated in active-clamp mode. The proposed converter is added active-clamping circuit to boost-flyback single-stage power factor corrected power supply. The active-clamping circuit limits voltage spikes, recycles the energy trapped in the leakage inductance, and provides a mechanism for achieving soft switching of the electronic switches to reduce the switching loss. The auxiliary switch of active-clamping circuit uses the same control and driver circuit as the main switch to reduce the additional cost and size. To verify the performance of the proposed converter, a 100W converter has been designed. The proposed converter gives good power factor correction, low line current harmonic distortions, and tight output voltage regulation, as used unity power factor.

  • PDF

Isolated PFC Converter Based on an ADAB Structure with Harmonic Modulation for EV Chargers

  • Choi, Seung-Won;Kim, Yoon-Jae;Lee, Il-Oun;Lee, Jun-Young
    • Journal of Power Electronics
    • /
    • 제18권2호
    • /
    • pp.383-394
    • /
    • 2018
  • This paper presents an isolated power factor correction converter for general-purpose electric vehicle chargers with a wide output voltage range. The converter is based on an asymmetrical dual active bridge structure so that the voltage stress of switching devices can be eliminated by transferring the transformer leakage inductance to the circuit parameters. Harmonic and output controls are performed by secondary switches, and primary switches are only operated at a fixed frequency with a 50% duty ratio. A harmonic modulation technique is also adopted to obtain a near-unity power factor without input current monitoring. The feasibility of the proposed charger is verified with a 3.3 kW prototype.

플라이백 다권선 트랜스포머 균등화 회로에서의 누설 인덕턴스 영향 보상 (Compensation of leakage inductance effect in multi-winding cell balancing circuit)

  • 김진웅;하정익
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 추계학술대회 논문집
    • /
    • pp.153-154
    • /
    • 2012
  • 여러 개의 셀을 직렬 연결하여 사용하는 대용량 리튬-이온 배터리 사용이 많아지면서 각 셀 간의 전압 평형문제가 중요해지고 있다. 직렬 연결된 각 셀들의 전압이 평형을 이루지 않게되면 그 배터리의 용량을 충분히 활용하지 못하게 되고 배터리 수명 또한 줄게 된다. 셀들 간의 전압 불균형을 바로 잡기 위해선 별도의 셀 전압 균등화 회로가 필요 하다. 본 논문에서는 플라이백 다권선 변압기를 이용한 셀 균등화 회로에서 2차측의 누설 인덕턴스에 의해 생길 수 있는 출력 전압의 차이를 LC필터를 통해 보상하여 셀을 일정한 전압으로 평형을 이룰 수 있도록 하는 회로를 제안하고 시뮬레이션을 통하여 그 타당성을 검증 한다.

  • PDF

An Isolated Soft-Switching Bidirectional Buck-Boost Inverter for Fuel Cell Applications

  • Zhang, Lianghua;Yang, Xu;Chen, Wenjie;Yao, Xiaofeng
    • Journal of Power Electronics
    • /
    • 제10권3호
    • /
    • pp.235-244
    • /
    • 2010
  • This paper presents a new isolated soft-switching bidirectional buck-boost inverter for fuel cell applications. The buck-boost inverter combines an isolated DC-DC converter with a conventional inverter to implement buck-boost DC-DC and DC-AC conversion. The main switches achieve zero voltage switching and zero current switching by using a novel synchronous switching SVPWM and the volume of the transformer in the forward and fly-back mode is also minimized. This inverter is suitable for wide input voltage applications due to its high efficiency under all conditions. An active clamping circuit reduces the switch's spike voltage and regenerates the energy stored in the leakage inductance of the transformer; therefore, the overall efficiency is improved. This paper presents the operating principle, a theoretical analysis and design guidelines. Simulation and experimental results have validated the characteristics of the buck-boost inverter.

전압형 인버터로 구동되는 유도기의 안정화 제어 (The Stablized Control Method for The Voltage Source Inverter Fed Induction Motor Driver)

  • 노성채;이현우;이오걸;우정인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.567-570
    • /
    • 1989
  • A constant V/F control system of voltage contrlled PWM inverter has a unstable operation of the low- speed and the light-load. In this paper, the authors propose stability control with idealized operation of induction motor by the neglect of primary leakage inductance and resistance. Also ldealized operation system is adopted voltage error, feed back impedance circuit, and increasing resistance from dead time of switching is compensated by the soft ware with u-processors. The proposed simulation of the idealized control method is proved at the low-speed operation for three phase induction motor.

  • PDF

무접점 베터리 충전 장치용 Half-Bridge 직렬 공진 컨버터 분석 및 설계 (Analysis and Design of Half-Bridge Series Resonant Converter for Non-Contact Battery Charger)

  • 김창균;유정식;박종후;조보형;서동현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2508-2511
    • /
    • 1999
  • A non-contact battery charger which transfers energy using magnetic field without any electrical contacts is designed using half-bridge series resonant converter. This converter utilizes series resonance to reduce the undesirable effect of large leakage inductance of the non-contact transformer and ZVS operation can reduce switching losses. In this paper. analysis and design procedure of half-bridge series resonant converter with non-contact transformer is presented. Input voltage is 85VAC ${\sim}$ 270VAC, output voltage and current is 4.1V and 800mA, respectively. Furthermore, a method for calculating the secondary current of the transformer to control battery charging current in constant current charging mode which is required for litium-ion battery is proposed and the performance is verified from experiments.

  • PDF

변압기 영향을 포함한 고정주파수 LCL형 DC-DC 컨버터 해석 (Analysis of A Fixed Frequency LCL-type DC-DC Converter Including the Effect of High-Frequency Transformer)

  • 박상은;차한주
    • 전기학회논문지
    • /
    • 제65권1호
    • /
    • pp.81-87
    • /
    • 2016
  • An LCL-type Isolated dc-dc converter operating for constant output voltage is analyzed, including the effect of a high frequency transformer using ac complex circuit approximation. Its solution is derived and is used to obtain the characteristics of the proposed converter. The analyses show through converter modeling, phasor diagram and gain comparison that inclusion of a high frequency transformer results in introduction of magnetizing inductance and leakage inductances at conventional LCL dc-dc converter with ideal transformer. The theoretical and simulation results are presented in case of the wide variations in input voltage and load current in detail. Analysis and simulation results observed that introduction of a transformer in the dc-dc converter had considerable effect on the performance, especially in the case of low output voltage and large load.

새로운 유도전동기의 파라미터 추정에 관한 연구 (A Study on the New Parameter Estimation of Induction Motor)

  • 이동국;오세진;김종수;김경호;김성환
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.47-48
    • /
    • 2005
  • This paper describes how an Artificial Neural Network(ANN) can be employed to improve a speed estimation in a vector controlled induction motor drive. The system uses the ANN to estimate changes in the motor resistance, which enable the sensorless speed control method to work more accurately. Flux Observer is used for speed estimation in this system. Obviously the accuracy of the speed control of motor is dependent upon how well the parameters of the induction machine are known. These parameters vary with the operating conditions of the motor; both stator resistance(Rs) and rotor resistance(Rr) change with temperature, while the stator leakage inductance varies with load. This paper proposes a parameter compensation technique using artificial neural network for accurate speed estimation of induction motor and simulation results confirm the validity of the proposed scheme.

  • PDF

유도전동기의 고성능 벡터 제어를 위한 유도전동기 정수 측정 (Motor Parameter Measurement for High Performance Vector Control of an induction Motor)

  • 한상수
    • 전자공학회논문지
    • /
    • 제52권8호
    • /
    • pp.126-131
    • /
    • 2015
  • 유도전동기의 고성능 속도 제어를 위해서는 전동기 정수의 정확한 측정이 필요하다. 특히 전동기의 토크 제어를 위해 사용되는 벡터 제어의 경우 회전자 저항과 인덕턴스의 항으로 주어지는 시정수는 제어기의 성능에 큰 영향을 준다. 또한 고정자 저항과 누설 인덕턴스는 전류제어기와 속도 제어기의 이득을 구하고 설계하는 중요한 변수가 된다. 본 논문에서는 기존의 정수 측정 방법을 수정 보완한 새로운 유도 전동기 정수 측정방법을 제시한다.