• Title/Summary/Keyword: Leakage dose

Search Result 149, Processing Time 0.03 seconds

System Software Design of Computed Tomography Radiation Dose Management (컴퓨터 단층촬영(CT) 방사선 노출 관리 시스템 소프트웨어 설계)

  • Yang, Yu-mi;Lee, Kil-hung;Cho, Sang-wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.489-492
    • /
    • 2014
  • This thesis provides the design of system software for the management of radiation dose that is generated using computer tomography(CT). Because radiation exposure is different depending on the difference in sensitivity to each part for each of the patient's body, if we will be able to manage an appropriate amount of radiation, it is possible to estimate the radiation exposure of the patient as a result. Recently, radiation leakage incident of Japanese nuclear power plant was in the news internationally and there is a growing interest not only a nuclear power plant, to medical radiation exposure. In spite of the fact that currently safety management of radiation is under control only the workers of the radiation involved, exposure management of patients until now have been required. Surgery and inspection using the radiation in Korea will increase, due to this medical exposure has increased, but it is a reality that medical institution don't know the level of radiation exposure applied to the patient. Therefore a system for managing the radiation exposure of the patient from the medical institution is required. This paper proposes a design of a software program to manage the radiation exposure of CT is an typical imaging tool to use the radiation in the medical institution. By check the amount of radiation dose and set the limit of dose, we would help to optimize the medical exposure of the patient.

  • PDF

Evaluation of Ovary Dose for woman of Childbearing age Woman with Breast cancer in tomotherapy (가임기 여성의 유방암 토모치료 시 난소선량 평가비교)

  • Lee, Soo Hyeung;Park, Soo Yeun;Choi, Ji Min;Park, Ju Young;Kim, Jong Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.337-343
    • /
    • 2014
  • Purpose : The aim of this study is to evaluate unwanted scattered dose to ovary by scattering and leakage generated from treatment fields of Tomotherapy for childbearing woman with breast cancer. Materials and Methods : The radiation treatments plans for left breast cancer were established using Tomotherapy planning system (Tomotherapy, Inc, USA). They were generated by using helical and direct Tomotherapy methods for comparison. The CT images for the planning were scanned with 2.5 mm slice thickness using anthropomorphic phantom (Alderson-Rando phantom, The Phantom Laboratory, USA). The measurement points for the ovary dose were determined at the points laterally 30 cm apart from mid-point of treatment field of the pelvis. The measurements were repeated five times and averaged using glass dosimeters (1.5 mm diameter and 12 mm of length) equipped with low-energy correction filter. The measures dose values were also converted to Organ Equivalent Dose (OED) by the linear exponential dose-response model. Results : Scattered doses of ovary which were measured based on two methods of Tomo helical and Tomo direct showed average of $64.94{\pm}0.84mGy$ and $37.64{\pm}1.20mGy$ in left ovary part and average of $64.38{\pm}1.85mGy$ and $32.96{\pm}1.11mGy$ in right ovary part. This showed when executing Tomotherapy, measured scattered dose of Tomo Helical method which has relatively greater monitor units (MUs) and longer irradiation time are approximately 1.8 times higher than Tomo direct method. Conclusion : Scattered dose of left and right ovary of childbearing women is lower than ICRP recommended does which is not seriously worried level against the infertility and secondary cancer occurrence. However, as breast cancer occurrence ages become younger in the future and radiation therapy using high-precision image guidance equipment like Tomotherapy is developed, clinical follow-up studies about the ovary dose of childbearing women patients would be more required.

Optimized Design and Manufacture of Wideband Pulsed Gamma-ray Sensors (광대역 펄스감마선 탐지센서 최적화 설계 및 제작)

  • Jeong, Sang-hun;Lee, Nam-ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.1
    • /
    • pp.223-228
    • /
    • 2017
  • In this paper, we are proposing an optimal design of wideband pulsed type gamma-ray sensors. These sensors were manufactured based on the design results and after word electrical properties were analyzed. The sensor input parameters were derived on the basis of pulsed gamma-ray spectrum and time-dependent energy rate, and the output current which were derived on the basis of the sensor sensitivity control circuit. Pulsed gamma-ray sensors were designed using the TCAD simulators. The design results show that the optimal Epi layer thickness is 45um with the applied voltage 3.3V and the diameter is 2.0mm. The doping concentrations are as follows : N-type is an Arsenic as $1{\times}10^{19}/cm^3$, P-type is a Boron as $1{\times}10^{19}/cm^3$ and Epi layer is Phosphorus as $3.4{\times}10^{12}/cm^3$. The fabricated sensor was a leakage current, 12pA at voltage -3.3V and fully depleted mode at voltage -5V. A test result of pulsed radiation shows that the sensor gives out the optimal photocurrent.

Differential Growth Response and Gene Expression in Relation to Capsidiol Biosynthesis of Red Pepper Plant and Cultured Cells by γ-Ray and UV Stress (방사선과 자외선에 대한 고추 식물체 및 배양세포의 생장반응과 Capsidiol 생합성 유전자의 발현 차이)

  • An, Jung-Hee;Kim, Jae-Sung;Jeong, Jeong-Hag;Oh, Sei-Myoung;Kwon, Soon-Tae
    • Journal of Plant Biotechnology
    • /
    • v.30 no.2
    • /
    • pp.201-206
    • /
    • 2003
  • Differential responses of red pepper plant and cultured cells to enhanced ${\gamma}$-ray($^{60}$ Co) and ultraviolet(UV) stress were investigated. In seed treatment, 1 Gy of ${\gamma}$-ray increased seedling dry weight up to 19.1%, but 50 Gy treatment markedly ingibited seed germination and subsequent growth of seedling. UV treatment to seed did not change the germination ability of seeds and the growth of seedlings regardless of duration of UV treatment until 24 hrs. In case of UV treatment to seedlings, plant injury was seriously progressed even after the seedlings were returned to no UV condition, and eventually all the leaves showed chlorosis by the stress. However, progress of plant injury by ${\gamma}$-ray stress slower than that caused by UV stress, and even at the high dose of ${\gamma}$-ray 50 Gy, did not caused the cholrosis of stressed plant leaf. Amount of electrolytes leakage from plant leaf by UV treatment for 24hrs was increased up to 28.8 folds in comparison with untreated control, whereas that of 50 Gy of ${\gamma}$-ray was increased only 1.2 folds. UV stress induced the production of capsidiol, antimicrobial phytoalexin, by activation of gene expression involved in capsidiol biosynthesis, such as sesquiterpene cyclase and cyclase and cytochrome P450 hydroxylase in the leaf and cultured cell, but ${\gamma}$-ray stress induced neither the production of capsidiol nor expression of the genes.

Early Germination Response of Soybean Seed to Accelerated Aging and Low Dose Gamma Irradiation

  • Hwangbo, Jun-Kwon;Kim, Jae-Sung;Lim, Ji-Hyeok;Baek, Myung-Hwa;Chung, Byung-Yeoup;Kim, Jin-Hong
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.49 no.1
    • /
    • pp.25-29
    • /
    • 2004
  • The responses of soybean seeds were evaluated to accelerated aging and gamma irradiation with regard to germination, seed leakage, seed leachate component and dry weight of hypocotyl and primary root of the germinating seed. Accelerated aging significantly reduced the final germination rate while gamma irradiation increased the final germination rate. Furthermore, the interactive effects occurred that the final germination rate of 5-day aged seeds increased considerably in response to 4 Gy of gamma irradiation. The extent to which the electrolyte was leaked from the seeds (conductivity) was significantly affected by accelerated aging and showed a close negative correlation with the germination rate. Gamma irradiation, however, did not significantly affect the electrical conductivity of seed leachate. The accelerated aging significantly increased the concentrations of the particular electrolytes leaked from the seeds while the gamma irradiation did not affect those concentrations. Of the electrolytes leaked from the seeds, Ca and Mg showed relatively lower concentrations while K showed greater concentrations than others. Moreover, N and P showed similar responses to aging treatment. Aging treatment significantly affected dry weight (DW) of hypocotyls and primary root. Also, gamma irradiation decreased DW of hypocotyls and primary root, particularly for 8 Gy associated with 5 days aging treatment. The data were discussed in terms of the relationships of seed vigor with aging treatment and gamma irradiation.

Physicochemical Characterization and In Vivo Evaluation of Thermosensitive Diclofenac Liquid Suppository

  • Yong, Chul-Soon;Choi, Young-Kwon;Kim, Yong-Il;Park, Byung-Joo;Quan, Qi-Zhe;Rhee, Jong-Dal;Kim, Chong-Kook;Choi, Han-Gon
    • Archives of Pharmacal Research
    • /
    • v.26 no.2
    • /
    • pp.162-167
    • /
    • 2003
  • Liquid suppository systems composed of poloxamers and bioadhesive polymers were easy to administer to the anus and mucoadhesive to the rectal tissues without leakage after the dose. However, a liquid suppository containing diclofenac sodium could not be developed using bioadhesive polymers. since the drug was precipitated in this preparation. To develop a liquid suppository system using sodium chloride instead of bioadhesive polymers, the physicochemical properties such as gelation temperature, gel strength and bioadhesive force of various formulations composed of diclofenac sodium, poloxamers and sodium chloride were investigated. Furthermore, the pharmacokinetic study of diclofenac sodium delivered by the liquid suppository was performed. Diclofenac sodium significantly increased the gelation temperature and weakened the gel strength and bioadhesive force, while sodium chloride did the opposite. The liquid suppositories with less than 1.0% of sodium chloride, in which the drug was not precipitated, were inserted into the rectum without difficulty and leakage. Furthermore, liquid suppository gave significantly higher initial plasma concentrations and faster Tmax of diclofenac sodium than did solid suppository, indicating that drug from liquid suppository could be absorbed faster than that from solid one in rats. Our results suggested that a thermosensitive liquid suppository system with sodium chloride and poloxamers was a more physically stable, convenient and effective rectal dosage form for diclofenac sodium.

The Recent Trend of the National and International Standard of Manufacturing Quality Control for Diagnostic X-ray Equipment (진단용엑스선장치 제조품질관리에 관한 국내.외 규격의 동향)

  • Choi, In-Seok;Kim, Jung-Min;Jeong, Hoi-Woun;Min, Jung-Whan;Lee, In-Su
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.1-15
    • /
    • 2009
  • Newly published IEC 60601-1-3 ; 2008 2nd Edition has two important meanings. First, Radiation Quality and Dose should make sure for safety of patient and staff in manufacturing diagnostic X-ray equipment. Second, it should be minimized of Leakage Radiation, Residual Radiation, and Stray Radiation. The requirement to make enactment or revision of national standard for diagnostic X-ray Equipment is as follows : 1. It should be adjusted the new standard to the recent IEC Publication under the consideration of the Korea medical circumstances. 2. For focus to the Radiation Safety, IEC 60601-1-3 (General requirements for radiation protection in diagnostic X-ray equipment) could be applied to the new regulation. It should be compact sentence. 3. A sudden Notification change should not be desired. It needs a enough time to make easy the circumstances.

  • PDF

Electrical Properties and Defect States in ZnO Substrates Irradiated by MeV Electron-beam (고 에너지 전자빔 조사에 따른 ZnO 기판의 결함생성 및 전기적 특성 변화)

  • Lee, Dong-Uk;Song, Hoo-Young;Han, Dong-Seok;Kim, Seon-Pil;Kim, Eun-Kyu;Lee, Byung-Cheol
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.3
    • /
    • pp.199-205
    • /
    • 2010
  • The electrical properties and defect states in ZnO substrates were studied during high-energy electron beam irradiations. 1 MeV and 2 MeV electron-beam with dose of $1{\times}10^{16}$ electrons/$cm^2$ were irradiated on Zn-surface of the sample. In the sample irradiated by 1 MeV, the leakage current was increased by electron-beam induced surface defects, while the enhancement of on/off property and the decrease of leakage current appeared in the 2 MeV irradiated sample. From the deep level transient spectroscopy measurements for these samples, it showed that the defect states with the activation energies of $E_c$-0.33 eV and $E_v$+0.8 eV are generated during the high energy electron-beam irradiation. Especially, it considered that the $E_c$-0.33 eV state related with O-vacancy affects to their electrical properties.

Dosimetric Comparison of Three-Dimensional Conformal, Intensity-Modulated Radiotherapy, Volumetric Modulated Arc Therapy, and Dynamic Conformal Arc Therapy Techniques in Prophylactic Cranial Irradiation

  • Ismail Faruk Durmus;Dursun Esitmez;Guner Ipek Arslan;Ayse Okumus
    • Progress in Medical Physics
    • /
    • v.34 no.4
    • /
    • pp.41-47
    • /
    • 2023
  • Purpose: This study aimed to dosimetrically compare the technique of three-dimensional conformal radiotherapy (3D CRT), which is a traditional prophylactic cranial irradiation method, and the intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) techniques used in the last few decades with the dynamic conformal arc therapy (DCAT) technique. Methods: The 3D CRT, VMAT, IMRT, and DCAT plans were prepared with 25 Gy in 10 fractions in a Monaco planning system. The target volume and the critical organ doses were compared. A comparison of the body V2, V5, and V10 doses, monitor unit (MU), and beam on-time values was also performed. Results: In planned target volume of the brain (PTVBrain), the highest D99 dose value (P<0.001) and the most homogeneous (P=0.049) dose distribution according to the heterogeneity index were obtained using the VMAT technique. In contrast, the lowest values were obtained using the 3D CRT technique in the body V2, V5, and V10 doses. The MU values were the lowest when DCAT (P=0.001) was used. These values were 0.34% (P=0.256) lower with the 3D CRT technique, 66% (P=0.001) lower with IMRT, and 72% (P=0.001) lower with VMAT. The beam on-time values were the lowest with the 3D CRT planning (P<0.001), 3.8% (P=0.008) lower than DCAT, 65% (P=0.001) lower than VMAT planning, and 76% (P=0.001) lower than IMRT planning. Conclusions: Without sacrificing the homogeneous dose distribution and the critical organ doses in IMRTs, three to four times less treatment time, less low-dose volume, less leakage radiation, and less radiation scattering could be achieved when the DCAT technique is used similar to conventional methods. In short, DCAT, which is applicable in small target volumes, can also be successfully planned in large target volumes, such as the whole-brain.

(A Study on the Annealing Methods for the Formation of Shallow Junctions) (박막 접합 형성을 위한 열처리 방법에 관한 연구)

  • 한명석;김재영;이충근;홍신남
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.39 no.1
    • /
    • pp.31-36
    • /
    • 2002
  • Low energy boron ions were implanted into the preamorphized and crystalline silicon substrates to form 0.2${\mu}m$ $p^+-n$ junctions. The rapid thermal annealing(RTA) was used to annihilate the crystal defects due to implantation and to activate the implanted boron ions, and the furnace annealing was employed to reflow the BPSG(bolo-phosphosilicate glass). The implantation conditions for Gepreamorphization were the energy of 45keV and the dose of 3$\times$1014cm-2. BF2 ions employed as a p-type dopant were implanted with the energy of 20keV and the dose of 2$\times$1015cm-2. The thermal conditions of RTA and furnace annealing were $1000^{\circ}C$/10sec and $850^{\circ}C$/40min, respectively. The junction depths were measured by SIMS and ASR techniques, and the 4-point probe was used to measure the sheet resistances. The electrical characteristics were analyzed via the leakage currents of the fabricated diodes. The single thermal processing with RTA produced shallow junctions of good qualities, and the thermal treatment sequence of furnace anneal and RTA yielded better junction characteristics than that of RTA and furnace anneal.