• 제목/요약/키워드: Leakage characteristics

검색결과 1,658건 처리시간 0.033초

뇌충격전류에 의한 산화아연형 피뢰기 소자의 전기적 특성과 피뢰기 열화진단 전문가 시스템 (Electrical Characteristics of ZnO Blocks by a Lightning Impulse Current and the Expert System to Diagnose Arrester Deterioration)

  • 길경석;한주섭;송재용;김명진;김정배;조한구
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권4호
    • /
    • pp.152-157
    • /
    • 2002
  • This paper describes an effect of a single- and a quadruple-lightning impulse currents on electrical characteristics of ZnO blocks, and an expert system to diagnose arrestor deterioration. To deduce the parameters needed for diagnosing arrester deterioration, an accelerate deterioration teat is carried out. In the experiment, leakage current components are measured. Also, wave height distribution of the leakage current according to the progress of arrester deterioration is analyzed. From the experimental results, the wave height distribution of the leakage current showed conspicuous difference even in an immaterial leakage current increase. Therefore, the use of wave height distribution of the leakage current in deterioration diagnostic technique makes more accurate diagnosis than the conventional method by using only a leakage currant value. Finally, the expert system based on the experimental results is developed and the system can diagnose arrestor deterioration by measuring the leakage current and its wade height distribution.

Self-healing and leakage performance of cracks in the wall of a reinforced concrete water tank

  • Gao, Lin;Wang, Mingzhen;Guo, Endong;Sun, Yazhen
    • Earthquakes and Structures
    • /
    • 제16권6호
    • /
    • pp.727-741
    • /
    • 2019
  • A reinforced concrete water tank is a typical functional liquid storage structure and cracks are the greatest threat to the liquid storage structure. Tanks are readily cracked due to seismic activity, thereby leading to the leakage of the stored liquid and a loss of function. In order to study the effect of cracks on liquid storage tanks, self-healing and leakage tests for bending cracks and through cracks in the walls of a reinforced concrete water tank were conducted. Material performance tests were also performed. The self-healing performance of bending cracks in a lentic environment and through cracks in a lotic environment were tested, thereby the self-healing width of bending micro-cracks in the lentic environment in the short term were determined. The through cracks had the capacity for self-healing in the lotic environment was found. The leakage characteristics of the bending cracks and through cracks were tested with the actual water head on the crack. The effects on liquid leakage of the width of bending cracks, the depth of the compression zone, and the acting head were determined. The relationships between the leakage rate and time with the height of the water head were analyzed. Based on the tests, the relationships between the crack characteristics and self-healing as well as the leakage were obtained. Thereby the references for water tank structure design and grading earthquake damage were provided.

절연유(絶緣油) 열화(劣化)센서 특성(特性) 연구(硏究) (A Study on the characteristics of degradation sensor for insulation oil)

  • 전영갑;선종호;강동식;주병수;윤진열;정상진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1371-1374
    • /
    • 1995
  • It is well known that the degradation of transformer oil conseqently lead to the failure of transformer. This paper discussed the characteristics of the degradation sensor checking transformer oil condition in live line. The degadation sensor is composed of base ring, electrodes and porous ceramic, passed through the transformer oil and checks the transformer oil condition through sensor's leakage current. So it is important to minimize the leakage current of base ring and connection parts. To investigate the leakage current of base ring and connection parts the characteristics of V-T-I and DC 2 KV and other examinations were performed. It is verified that ionized transformer oil caused by the expansion of temperature increases in the leakage current of porous ceramic sensor. It is certification that the leakage current of other parts of porous ceramic is very small(about 2%) compared with the porous ceramic body and it is confirmed that the leakage current in porous ceramic is changed sensitively according to the new oil(NO) and and the degradation oil(DO).

  • PDF

네트워크 트래픽 특성을 이용한 개인정보유출 탐지기법 (Detection of Personal Information Leakage using the Network Traffic Characteristics)

  • 박정민;김은경;정유경;채기준;나중찬
    • 정보처리학회논문지C
    • /
    • 제14C권3호
    • /
    • pp.199-208
    • /
    • 2007
  • 유비쿼터스 네트워크 환경에서 개인정보의 유출은 다양한 사이버 범죄를 야기하며 개인정보의 상품화로 프라이버시의 침해가 증가하므로 개인정보의 유출을 탐지하는 것은 매우 중요하다. 본 논문은 네트워크의 트래픽 특성을 기반으로 한 개인정보 유출 탐지 기법을 제안하고자 한다. 실제 대학망에서 정상 상태의 트래픽을 수집하여 트래픽의 특성을 분석함으로써 네트워크 트래픽이 자기유사성을 지님을 확인하였다. 개인정보의 유출을 시도하는 악성코드의 사전정보수집단계를 모사한 비정상적인 트래픽에 대하여 정상 트래픽에서의 자기유사성과의 변화를 살펴봄으로써 이상을 조기 감지할 수 있었다.

변압기(變壓器) 절연유(絶緣油) 열화(劣化)센서의 특성연구(特性硏究) (A study on the characteristics of degradation sensor for transformer insulation oil)

  • 전영갑;선종호;강동식;김문덕;권동진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1765-1768
    • /
    • 1996
  • It is well known that the degradation transformer oil is mainly effected to the failure of transformer. In this paper it is discussed the characteristics of the degradation sensor checking transformer oil condition in live line. The degadation sensor composed with base ring, electrodes and porous ceramic passed through the transformer oil and checked the transformer oil condition with sensor's leakage current. It is important to minimize the leakage current of base ring and connection parts. To investigate the leakage current of base ring and connection parts it is examined the characteristics of V-T-I and DC 2 KV and other examinations. It is verified that ionized transformer caused by the expansion of oil temperature increase in the leakage current of porous ceramic sensor. It is certificated that the leakage current of other parts of porous ceramic is very small (about 2 %) than the porous ceramic and it is confirmed that the leakage current in porous ceramic is changed sensitively according to the new oil(NO) and and the degradation oil(DO).

  • PDF

누출이 헬름홀츠 공명기의 소음저감 특성에 미치는 영향 (Effect of Leakage on the Noise Reduction Characteristics of Helmholtz Resonator)

  • 이일재
    • 한국소음진동공학회논문집
    • /
    • 제19권6호
    • /
    • pp.634-640
    • /
    • 2009
  • Helmholtz resonator has been used, especially in intake and exhaust systems of vehicles, due to its good noise reduction characteristics at low frequencies. Many approaches have been developed to predict the acoustic behavior of the resonator with the assumption that there is no leakage from the resonator. However, its behavior may be affected by leakage which may exist in manufacturing processes or on purpose. This study investigates the effect of leakage on the noise reduction characteristics of Helmholtz resonator with two practical examples. One is a resonator with a gap between baffle and housing of the resonator and the other one is a resonator with two drain holes on the baffle. The measured transmission loss shows that the resonance frequencies are considerably shifted to higher frequency due to the leakage. The Boundary Element Method was applied to predict the transmission loss of the Helmholtz resonator with drain holes. The comparison between the measured and predicted transmission loss shows that the acoustic impedance of the holes is essential for accurate predictions of the transmission loss.

Electrical Leakage Levels Estimated from Luminescence and Photovoltaic Properties under Photoexcitation for GaN-based Light-emitting Diodes

  • Kim, Jongseok;Kim, HyungTae;Kim, Seungtaek;Choi, Won-Jin;Jung, Hyundon
    • Current Optics and Photonics
    • /
    • 제3권6호
    • /
    • pp.516-521
    • /
    • 2019
  • The electrical leakage levels of GaN-based light-emitting diodes (LEDs) containing leakage paths are estimated using photoluminescence (PL) and photovoltaic properties under photoexcitation conditions. The PL intensity and open-circuit voltage (VOC) decrease because of carrier leakages depending on photoexcitation conditions when compared with reference values for typical LED chips without leakage paths. Changes of photovoltage-photocurrent characteristics and PL intensity due to carrier leakage are employed to assess the leakage current levels of LEDs with leakage paths. The current corresponding to the reduced VOC of an LED with leakage from the photovoltaic curve of a reference LED without leakage is matched with the leakage current calculated using the PL intensity reduction ratio and short-circuit current of the LED with leakage. The current needed to increase the voltage for an LED with a leakage under photoexcitation from VOC of the LED up to VOC of a reference LED without a leakage is identical to the additional current needed for optical turn-on of the LED with a leakage. The leakage current level estimated using the PL and photovoltaic properties under photoexcitation is consistent with the leakage level measured from the voltage-current characteristic obtained under current injection conditions.

형상설계에 관한 고속주축용 비접촉 시일의 밀봉특성 연구 (Design Effect of Sealing Characteristics of Non-Contact Type Seal for High Speed Spindle)

  • 나병철;전경진;한동철
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.610-614
    • /
    • 1996
  • Sealing of lubricat-air mixture in the high performance machining conte is one of most the important characteristics to carry out enhanced lubrication. High speed spindle requires non-contact type of sealing mechanism. Evaluating an optimum seal design to minimize leakage is concerned in the aspect of flow control. Effect of geometry and leakage path are evaluated according to variation of sealing geometry, Velocity, pressure, turbulence intensity of profile is calculated to fina more efficient geometry and variables. This offers a methodological way of enhancement seal design for high speed spindle. The working fluid is regarded as two phases that are mixed flow of oil phase and air phase. It is more reasonable to simulate an oil jet or oil mist type high speed spindle lubrication. Turbulence and compressible flow model are used to evaluate a flow characteristic, This paper arranges a geometry of mostly used non-contact type seal and analyzes leakage characteristics to minimize a leakage on the same sealing area.

  • PDF

화재전류(IGR) 경보 기능이 내장된 누전경보차단기의 개발 및 안전성 평가에 관한 연구 (Development and Safety Evaluation of Earth Leakage Alarm Breaker Equipped with Fire Current (IGR) Alarming Function)

  • 고완수;최충석
    • 한국화재소방학회논문지
    • /
    • 제34권3호
    • /
    • pp.43-48
    • /
    • 2020
  • 본 연구에서는 누전경보 기능이 내장된 누전경보차단기(JER-E2S, ETECKOREA Co., Korea)를 개발하고, 그 특성을 분석하였다. 개발된 누전경보차단기는 단상 220 V 전용으로 정격전류는 32 A, 20 A, 20 A(화장실용), 16 A 등이다. JER-E2S는 기존 누전차단기(ELB)의 특성을 모두 만족하고 있으며, 13 ± 2 mA의 저항성누설전류(Igr)인 화재전류가 전선로에 흐르면 실시간 검출하여 LED 램프로 위험 상태를 점멸할 수 있는 제품이다. 개발된 누전경보차단기는 LED 램프 및 통신기기 등에서 필연적으로 발생되는 용량성누설전류(Igc)에 대한 내성이 있어서 안정적인 전기 공급이 가능하다. 또한, 누전경보차단기는 순간지락 정전보호 기능이 있어서 작은 물방울 및 나뭇잎 등의 순간지락에 따른 차단기의 오동작 없이 전원 공급이 가능하다. 그리고 개발된 누전경보차단기의 대기전력은 0.1 W 이하로 기존 ELB에 비해 절전 성능이 3~8배 우수한 특성을 나타냈으며, 일반 120 ㎡의 아파트 1 세대에 10개 정도의 누전경보차단기가 설치되었을 때 1 개월에 2~5 kWh의 전기를 절감할 수 있다. 개발된 누전경보차단기는 기존 누전차단기의 특성을 만족할 뿐만 아니라 전기화재 예방기능 및 오동작 방지기능이 있어서 전원 품질이 우수하고, 전기화재 예방에 혁신적으로 기여할 수 있는 제품이다.

수중용접봉으로 용접한 누수 배관 용접부위의 부식 특성 평가 (Evaluation of Corrosion Characteristics on Welding Part of Leakage Water Pipe by Underwater Welding Electrode)

  • 김진경;문경만
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.93-94
    • /
    • 2006
  • The repair welding of small leakage parts on the water pipeline in engine room is often and important factor in standby and emergency condition in a ship. So, the purpose of this study is to evaluate the corrosion characteristics of welding part of leakage water pipe in case of some underwater welding electrodes. The corrosion current density between welding metal and base metal was considerably different according to used underwater welding electrodes. In case of DC welding, its corrosion characteristics was better than that of AC welding.

  • PDF