송전용 자기애자(36,000LBS)의 오손 등급별 환경변화에 따른 누설전류 분석 및 비교 연구 (A Study on the Comparison and Analysis of Leakage Current according to Environmental Variation of EHV insulators(36,000LBS) by Pollution Level)

  • 최인혁;최장현;정윤환;이동일;정길조;신태우;방항권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.527-529
    • /
    • 2004
  • This paper researched leakage current characteristics of EHW insulators(36,000lbs) to artificially contaminated clay and kaolin through construction of long-periods testing facility. Insulators were contaminated and classified into the ESDD level(B, C and D) under IEC Pub. 60507 standards method. As a result of tests, leakage current of the heavily contaminated D level to clay was approximately 2,260 $[\muA]$, which is contaminated to kaolin was approximately 3,200 $[\muA]$, during initial rainfall. However after raining, leakage current of naturally washed contamination insulators was lower at approximately 300 $[\muA]$. As regular temperature $20^{\circ}C$, leakage current increased greatly in case humidity density was over $72\%$. But, leakage current was not influenced by temperature variation in case of regular $\%$ humidity.

  • PDF

수소타운 정압기실 내 수소 누출 특성 연구 (A Study on Characteristics of Hydrogen Leakage in Hydrogen Town Governor Room)

  • 남태호;김동환;이정운;이승국;이연재
    • 한국수소및신에너지학회논문집
    • /
    • 제27권6호
    • /
    • pp.685-692
    • /
    • 2016
  • Hydrogen will be a future eco-friendly energy source that can replace current fossil fuels However when hydrogen gas leaks and people inhale a lot of hydrogen gases, they can have fatal effects fell into comas. Therefore, we need to develop a safety technology and related guidelines for reducing risks of hydrogen leakage. In this regard, we carried out demonstration tests assuming a situation of hydrogen leakage. Before the experiments, we analyze the standards for governor facilities to check vent positions and sensor positions. Then, we select four types of ventilation structures and proceeds with the experiments of hydrogen leakage at 1 LPM and 1.5 LPM. Based on the experimental results, we propose the direction on optimization of vent positions and sensor positions in the hydrogen leakage situation.

LDPE에서 부시형 전기트리의 성장에 수반되는 부분방전 펄스의 특성 (Properties of PD Pulses accompanying with propagation of Bush-type tree in LDPE)

  • 박영국;강성화;정수현;박철현;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.293-296
    • /
    • 1998
  • Surface electrical conduction in insulator is most important factor to assess the insulation performances of outdoor insulating materials. In this paper, contamination performance of the widely used materials for outdoor insulator - porcelain, EPDM, Silicone rubber - were discussed by measuring properties of average leakage current and scintillation discharge pulses under artificial contamination conditions. The artificial contaminations used were deionized distilled water fog, 0.5wt% NaCl salt fog of light pollution and 2wt% NaCl salt fog of medium pollution. The average leakage current was appeared linearly with applied voltage at dry and clean surface condition. The magnitude of leakage current was almost same at different kinds of samples. In case of deionized distilled water fog, the characteristics of leakage current and applied voltage was most different to that in case of dry and clean condition. In case of salt fog pollution condition, The leakage current was increased above critical voltage. The scintillation discharges were also activated at the level. the leakage current and scintillation discharges were increased with increasing pollution degree. The resistance to pollution properties of silicone rubber appeared excellent among them.

  • PDF

부하종류에 따른 회로의 누설전류 및 절연저항 특성 연구 (Study on Characteristics of Leakage Current and Insulation Resistance for a Circuit According to Load Types)

  • 한경철;최용성
    • 전기전자학회논문지
    • /
    • 제23권2호
    • /
    • pp.364-369
    • /
    • 2019
  • 본 논문에서는 전기재해를 일으킬 수 있는 요소를 미리 제거하기 위해 전등부하, 전열부하, 동력부하를 대상으로 누설전류와 절연저항을 측정하여 분포비율과 누적비율을 비교하고 분석하여 보다 효과적이고 신뢰성 있는 누설전류 검출방법을 찾고자 하였다. 누설전류와 절연저항의 적합 비율 차이는 전열부하 32.5%, 전등부하 22.8%, 동력부하 2.2%의 순으로 나타났으며, 누설전류계가 낮은 적합 비율을 나타내었으며, 누설전류계는 측정방법에 따른 오차와 용량성 누설전류 및 영상전류가 포함되어 있기 때문으로 생각되었다.

Effects of Carrier Leakage on Photoluminescence Properties of GaN-based Light-emitting Diodes at Room Temperature

  • Kim, Jongseok;Kim, Seungtaek;Kim, HyungTae;Choi, Won-Jin;Jung, Hyundon
    • Current Optics and Photonics
    • /
    • 제3권2호
    • /
    • pp.164-171
    • /
    • 2019
  • Photoluminescence (PL) properties of GaN-based light-emitting diodes (LEDs) were analyzed to study the effects of carrier leakage on the luminescence properties at room temperature. The electrical leakage and PL properties were compared for LEDs showing leakages at forward bias and an LED with an intentional leakage path formed by connecting a parallel resistance of various values. The leakages at the forward bias, which could be observed from the current-voltage characteristics, resulted in an increase in the excitation laser power density for the maximum PL efficiency (ratio of PL intensity to excitation power) as well as a reduction in the PL intensity. The effect of carrier leakages on PL properties was similar to the change in PL properties owing to a reduction of the photovoltage by a reverse current since the direction of the carrier movement under photoexcitation is identical to that of the reverse current. Valid relations between PL properties and electrical properties were observed as the PL properties deteriorated with an increase in the carrier leakage. The results imply that the PL properties of LED chips can be an indicator of the electrical properties of LEDs.

Dependence of Na+ leakage on intrinsic properties of cation exchange resin in simulated secondary environment for nuclear power plants

  • Hyun Kyoung Ahn;Chi Hyun An;Byung Gi Park;In Hyoung Rhee
    • Nuclear Engineering and Technology
    • /
    • 제55권2호
    • /
    • pp.640-647
    • /
    • 2023
  • Material corrosion in nuclear power plant (NPP) is not controlled only by amine injection but also by ion exchange (IX) which is the best option to remove trace Na+. This study was conducted to understand the Na+ leakage characteristics of IX beds packed with ethanolamine-form (ETAH-form) and hydrogen-form (H-form) resins in the simulated water-steam cycle in terms of intrinsic behaviors of four kinds of cation-exchange resins through ASTM test and Vanselow mass action modeling. Na+ was inappreciably escaped throughout the channel created in resin layer. Na+ leakage from IX bed was non-linearly raised because of its decreasing selectivity with increasing Na+ capture and with increasing the fraction of ETAH-form resin. Na+ did not reach the breakthrough earlier than ETAH+ and NH4+ due to the increased selectivity of Na+ to the cation-exchange resin (H+ < ETAH+ < NH4+ ≪ Na+) at the feed composition. Na+ leakage from the resin bed filled with small particles was decreased due to the enhanced dynamic IX processes, regardless of its low selectivity. Thus, the particle size is a predominant factor among intrinsic properties of IX resin to reduce Na+ leakage from the condensate polishing plant (CPP) in NPPs.

계측자료 분석에 의한 필댐의 장기 침투거동 연구 (A Study on Long-Term Seepage Behaviour of Fill Dam by the Monitoring Data Analysis)

  • 정규정;이송
    • 한국지반환경공학회 논문집
    • /
    • 제11권9호
    • /
    • pp.15-25
    • /
    • 2010
  • 본 연구는 중앙심벽형 필댐인 주암댐과 임하댐을 대상으로 자동계측에 의해 연속적으로 생산되는 침투수량 계측자료에 대하여 분석을 통하여 필댐 고유의 특성에 따른 장기 침투특성과 댐의 안전관리 방법을 검토하고자 하였다. 필댐의 침투수량 계측값에는 내재 하는 강우 성분 등의 외부 요인의 영향으로 직접적으로 이상 누수의 발생을 검출하는 것은 어렵다. 이 때문에, 종래 저수위와 강우량을 고려하는 중회귀분석 등에 의해 누수량을 추정하는 방법이 적용되어 왔으나, 강우 성분의 추정 오차가 상대적으로 크고 정밀도가 불량한 것으로 알려졌다. 본 논문에서는 강우 성분의 분리해석을 통해 직접적으로 강우 성분에 영향을 받지 않는 저수지 수위에 연동하는 댐별 침투거동을 평가함과 아울러 분석대상 댐의 지형적, 수리지질학적 특성을 반영한 3차원 수치해석을 실시하여 계측 침투수량 자료와 비교하였다. 2개 대상댐의 침투거동은 각각의 고유한 특징을 가지고 있으며, 장기적으로 침투수량의 감소를 보여주고 있어 안정적인 상태로 나타났다. 또한, 수문곡선분리법은 침투수 안전관리 방법으로 적용가능한 것으로 판단되었다.

서지 보호기의 열화 특성과 온라인 진단장치 (Deterioration Characteristics and an On-Line Diagnostic Equipment for Surge Protective Devices)

  • 박경수;왕국명;황성철;김선재;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제29권10호
    • /
    • pp.635-640
    • /
    • 2016
  • This paper dealt with the deterioration characteristics and an on-line diagnosis equipment for SPDs (surge protective devices). An accelerated aging test was carried out using a $8/20{\mu}s$ standard lightning impulse current to analyze the changes of electrical characteristics and to propose the diagnostic parameters and the criterion for deterioration of ZnO varistor which is the core component of SPDs. Based on the experimental results, an on-line diagnosis equipment for SPD was fabricated, which can measure the total leakage current, reference and clamping voltage. The leakage current measurement circuit was designed using a low-noise amplifier and a clamp type ZCT. A linear controller, the leakage current measurement part and a HVDC were used in the measurement of reference voltage. The measurement circuit of clamping voltage consisted of a surge generator and a coupling circuit. In a calibration process, measurement error of the prototype equipment was less than 3%.

Half-bridge 직렬공진 컨버터 적용 무접점 전원장치 효율특성 (Efficiency Characteristics of Half-bridge Series Resonant Converter for the Contact-less Power Supply)

  • 이현관;송환국;김은수;김윤호
    • 전기학회논문지
    • /
    • 제56권5호
    • /
    • pp.884-891
    • /
    • 2007
  • Comparing with the conventional transformer without the air gap, a contact-less transformer with the large air-gap (4.8cm) between the long primary winding and the secondary winding has the increased leakage inductance and the reduced magnetizing inductance. By the increased leakage inductance and the reduced magnetizing inductance on the primary of the contact-less transformer, a good deal of the primary current circulates through magnetizing inductance, which results in a massive loss and the high voltage gain characteristics for load variations in contact-less power supply (CPS). To consider these characteristics, in this paper, the efficiency characteristics of the contact-less power supply using a series resonant converter is presented, described and verified through theoretical analysis, computer simulation and experimental test of 2.5kW prototype.

트렌치 깊이에 따른 트랜지스터와 소자분리 특성 (Characteristics of Transistors and Isolation as Trench Depth)

  • 박상원;김선순;최준기;이상희;김용해;장성근;한대희;김형덕
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 하계종합학술대회 논문집
    • /
    • pp.911-913
    • /
    • 1999
  • Shallow Trench Isolation (STI) has become the most promising isolation scheme for ULSI applications. The stress of STI structure is one of several factors to degrade characteristics of a device. The stress contours or STI structure vary with the trench depth. Isolation characteristics of STI was analyzed as the depth of trench varied. And transistor characteristics was compared. Isolation punch-through voltage for n$^{+}$ to pwell and p$^{+}$ to nwell increased as trench depth increased. n$^{+}$ to pwell leakage current had nothing to do with trench depth but n$^{+}$ to pwell leakage current decreased as trench depth increased. In the case of transistor characteristics, short channel effect was independent on trench depth and inverse narrow width effect was greater for deeper trenches. Therefore in order to achieve stable device, it is important to minimize stress by optimizing trench depth.

  • PDF