SiC MOSFET 기생 커패시턴스의 영향을 고려한 DAB 컨버터에 사용되는 변압기의 누설인덕턴스 계산 (Transformer Leakage Inductance Calculation Used in DAB Converters Considering the Influence of SiC MOSFET Parasitic Capacitance)

  • 최철웅;고재섭;소지영;김대경
    • 한국산업융합학회 논문집
    • /
    • 제27권4_2호
    • /
    • pp.935-942
    • /
    • 2024
  • This study analyzes the effects of the parasitic capacitance of the SiC MOSFET used in the Dual Active Bridge ( DAB) converter and proposes a method for calculating the leakage inductance of the transformer. The DAB converter employs high-frequency switching to achieve high efficiency, high power density, and reliability. MOSFETs possess parasitic capacitance, which induces resonance with the leakage inductance of the transformer during switching operations, resulting in a voltage change delay. This paper discusses the effect of the delay of voltage changes on the DAB converter output and proposes a method to calculate the delay time. This method aims to equalize the delay time to minimize this effect and enhance the accuracy of the leakage inductance calculation of the transformer. The proposed method is validated through experiments and simulations.

수치계산에 의한 축류터보기계의 유동장과 유동온실의 평가 III [회전차 익말단의 누설손실과 효율저하에 대한 평가] (Evaluation of Flowfield and Flow Losses insied Axial Turbomachinery Using Numerical Calculation [Evaluation of Tip Leakage Loss and Reduction of Efficiency by Tip Clearance])

  • 노수혁;조강래
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1998년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.240-247
    • /
    • 1998
  • Leakage vortices formed near blade tip causes an increase of total pressure loss near casing endwall region and as a result, the efficiency of rotor decreases. The reduction of rotor efficiency is related to the size of tip clearance. In this study, the three-dimensional flowfields in an axial flow rotor were calculated with varying tip clearance under various flow rates, and the numerical results were compared with experimental ones. The effects of tip clearance and attack angle on the leakage vortex and overall performance, and the less distributions were investigated through numerical calculations. In this study, tip leakage flow rate and total pressure loss by tip clearance were evaluated using numerical results and aprroximate equations were presented to evaluate the reduction of rotor efficiency by tip leakage flow.

  • PDF

수치계산에 의한 축류터보기계의 회전차 익말단의 누설손실과 효율저하에 대한 평가 (Evaluation of Tip Leakage Loss and Reduction of Efficiency of Axial Turbomachinery Using Numerical Calculation)

  • 노수혁;조강래
    • 한국유체기계학회 논문집
    • /
    • 제2권1호
    • /
    • pp.73-80
    • /
    • 1999
  • Leakage vortices formed new blade tip causes an increase of total pressure loss near the casing endwall region and as a result, the efficiency of rotor decreases. The reduction of rotor efficiency is related to the size of the tip clearance. In this study, the three-dimensional flowfields in an axial flow rotor were calculated by varying the tip clearance under various flow rates, and the numerical results were compared with experimental ones. The effects of tip clearance and attack angle on the leakage vortex and overall performance, and the loss distributions were investigated through numerical calculations. In this study, tip leakage flow rate and total pressure loss by tip clearance were evaluated using numerical results and approximate equations were presented to evaluate the reduction of rotor efficiency by tip leakage flow.

  • PDF

GaAs MESFET에서 AlGaAs buffer layer에 의한 Drain 누설전류 차단 (Reduction of Drain Leakage Current by AlGaAs buffer layer in GaAs MESFET)

  • 박준;조중열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 D
    • /
    • pp.1321-1323
    • /
    • 1998
  • We investigated drain leakage current in GaAs power MESFET. The device we studied by 20 simulation has a $1000{\AA}$ thick AlGaAs buffer layer under n-GaAs active layer. The calculation shows that the leakage current through GaAs substrate is significantly reduced by the buffer layer.

  • PDF

누수탐사에 의한 유량분석 및 보수의 경제적 효과 (Analysis of Flow and Economic Benefit Through Water Leakage Detection and Repair)

  • 이승철;이상일
    • 상하수도학회지
    • /
    • 제19권1호
    • /
    • pp.8-15
    • /
    • 2005
  • Field measurement data on water leakage are not readily available and it causes inaccurate assessment of water demand and poor supply planning. In this study, the procedure for leakage detection and unaccounted water calculation is proposed and applied to a city. The city has suffered from the significant amount of leak water and the financial loss as a result. Measurements were made for pressure and flow at 18 locations before and after the repair. Repair of the leakage increased pressure up to $2.0kgf/cm^2$ and saved 17.1% of water supply from distribution reservoirs. Monetary value of annual water savings for the entire city amounts to 1 billion won. It is believed that leakage detection and data analysis conducted in this study will contribute to the change of current practice and to the establishment of better water supply management system.

1 차원모델을 이용한 초전도 변압기의 누설인덕턴스 계산 (One Dimensional Leakage Inductance Calculation of Superconducting Transformer)

  • 김태기;나완수;차귀수;한송엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.256-259
    • /
    • 1997
  • This paper describes on the leakage inductance calculations of superconducting (s/c) tranformer. When s/c transformer quenches, the magnetic energy stored in the leakage inductance dissipates in the form of Joule heating. So, it is highly desired to estimate the leakage inductances of a s/c transformer as it is designed. In this paper, we calculated the leakage inductance of sic transformer, using zeroth and first order model, and the calculated results were compared with the measured ones. It shows that 1st order model is enough to estimate the leakage inductacne of s/c transformer.

  • PDF

온도측정에 의한 산화아연형 피뢰기 진단 (ZnO Arrester Diagnosis by Measurement of Temperature)

  • 길경석;한주섭;송재용;서황동;문승보;박태곤
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권8호
    • /
    • pp.361-364
    • /
    • 2005
  • In this paper, surface temperatures of ZnO arresters as a function of ambient temperatures and leakage currents were experimentally investigated. The variations of the leakage current was below 10 uA, which comes about $4.5\%$ of the normal leakage current. Temperature differences between the ambient and the surface of arresters were not shown until $150\%$ to the normal leakage current, and were remarkable over $200\%$. From the results, we deduced a couple of polynomials which enables the calculation of the leakage current by the measurement of surface temperature. Tests on used arresters have shown the same results as the experimental one. Also, we expect that an arrester diagnosis is possible by measuring the surface temperature of them after more studies on the effect of wind, moisture penetration, and arrester types.

Research on mechanism of gas leakage in microchannels of steel containment vessels for nuclear power plants

  • Min He;Yueyao Chen;Zhen Wu;Gangling Hou;Jialong Wang;Zhuangfei Li;Yuzhu Wang;Hanze Li
    • Nuclear Engineering and Technology
    • /
    • 제56권8호
    • /
    • pp.3030-3042
    • /
    • 2024
  • Steel containment vessels for nuclear power plants can experience gas leakage due to minute defects such as cracks, corrosion, and aging, leading to gas leakage. A gas leakage model for microchannels is established to elucidate the mechanism underlying gas leakage within microchannels caused by these defects, specifically addressing the issue of unidirectional gas flow. Computational Fluid Dynamics (CFD) and the UK R6 method are employed to calculate the gas leakage rate within microchannels. Furthermore, the characteristics of gas flow within microchannels are explored, including the factors affecting the gas leakage rate. Validation of the calculation results is verified experimentally. The results indicate that the gas mass flow rate exhibits a linear decrease with decreasing internal pressure and a non-linear decline as temperature increases. Additionally, the gas mass flow rate demonstrates a negative correlation with the microchannel length but a positive association to its hydraulic diameter. The primary influencing factors on gas leakage rates are hierarchically ranked as follows: pressure difference, microchannel cross-sectional area, temperature, microchannel length, and microchannel hydraulic diameter.

가공 배전선에 의한 전자유도 발생 전류 계산 방법 (Formulation of Calculation Method for Inducing Current by Aerial Power Distribution Line)

  • 이상무
    • 전자공학회논문지
    • /
    • 제52권4호
    • /
    • pp.30-36
    • /
    • 2015
  • 전력선 시설 중 가공 배전선에 의하여 인근 통신선에 전자유도를 발생시키는 전류를 계산하는 방식을 수립하였다. 가공 배전선의 중성선은 50 m 마다 접지되어 있어서 부하 전류의 귀로 성분이 대지로 누설되기 때문에 주변의 통신선에 전자유도 장해를 발생시키게 된다. 현재 국가 기술기준에서 정하고 있는 방법에 의하면 귀로 전류가 흐르는 중성선을 하나의 차폐 도체로 간주하여 기유도전류를 산정하므로 통신선의 병행 위치에 따른 대지 귀로 전류의 누적적 변화 특성이 반영되지 못하여 계산된 유도전압의 실측값에 대한 오차가 커지지만 실제로 유도를 발생시키는 원인이 되는 대지 귀로 전류를 계산하는 방식을 적용하면 1000 %가 넘는 기존 계산 편차를 100 % 이내로 현격히 줄여주는 효과를 나타내었다.

합금강 표면결함의 잔류누설자장에 관한 연구 (A Study on the Residual Leakage Field in the Surface Defect of Alloy Steel)

  • 이인선;박은수
    • 비파괴검사학회지
    • /
    • 제9권1호
    • /
    • pp.22-29
    • /
    • 1989
  • The important point of MPI is the analysis of leakage field in the defective regions. The analysis of leakage field depends on many factors such like geometry and character of defect. In general the calculation of magnetic leakage fields arising from such defects presents an extremely complicated mathematical problem and is practically insoluable, since the inhomogeneities have complex geometrical shapes and may differ in physical nature. Therefore, this paper describes Hall probe measurements of residual leakage field around artificial flaws in alloy steel bar, and shows how the results to recent developments in 2D dipole and analytic models of the magnetic field defect interaction.