• 제목/요약/키워드: Leakage Rate

검색결과 928건 처리시간 0.035초

Self-healing and leakage performance of cracks in the wall of a reinforced concrete water tank

  • Gao, Lin;Wang, Mingzhen;Guo, Endong;Sun, Yazhen
    • Earthquakes and Structures
    • /
    • 제16권6호
    • /
    • pp.727-741
    • /
    • 2019
  • A reinforced concrete water tank is a typical functional liquid storage structure and cracks are the greatest threat to the liquid storage structure. Tanks are readily cracked due to seismic activity, thereby leading to the leakage of the stored liquid and a loss of function. In order to study the effect of cracks on liquid storage tanks, self-healing and leakage tests for bending cracks and through cracks in the walls of a reinforced concrete water tank were conducted. Material performance tests were also performed. The self-healing performance of bending cracks in a lentic environment and through cracks in a lotic environment were tested, thereby the self-healing width of bending micro-cracks in the lentic environment in the short term were determined. The through cracks had the capacity for self-healing in the lotic environment was found. The leakage characteristics of the bending cracks and through cracks were tested with the actual water head on the crack. The effects on liquid leakage of the width of bending cracks, the depth of the compression zone, and the acting head were determined. The relationships between the leakage rate and time with the height of the water head were analyzed. Based on the tests, the relationships between the crack characteristics and self-healing as well as the leakage were obtained. Thereby the references for water tank structure design and grading earthquake damage were provided.

대화식 주문형 비디오 서비스에서의 셋톱박스 버퍼 제어 방안 연구 (A Study on Buffer Control Method of Set-top Box in Interactive Video-on-Demand Service)

  • 신준호;김용득
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 추계종합학술대회 논문집
    • /
    • pp.1041-1044
    • /
    • 1999
  • This paper propose a solution to resolve data overflow or leakage when a subscriber receive data to service provider. The set-top box can communicate with a service provider and can inform the service provider its data overflow or leakage. When service provider received this control signal, it changes data transmit rate and transmits data with changed rate. The buffer of set-top box is important because incoming data from a service provider are stored by it.

  • PDF

Effect of Seed Priming on Quality Improvement of Maize Seeds in Different Genotypes

  • Seo Jung Moon;Lee Suk Soon
    • 한국작물학회지
    • /
    • 제49권5호
    • /
    • pp.381-388
    • /
    • 2004
  • In Korea, production of super sweet corn has been economically feasible and is substituting for traditional sweet corn due to better flavor in recent years. Major limiting factors for super sweet corn production are low field emergence and low seedling vigor. The optimum water potential (WP) for the priming of normal and aged seeds of dent, sweet (su) and super sweet (sh2) corns was studied to improve low seed quality. Seeds were primed at 0, -0.3, -0.6, -0.9, and -1.2 MPa of polyethylene glycol (PEG) 8000 solution at $15^{\circ}C$ for 2 days. Priming effects differed depending on the type of corn, seed quality, and WP of PEG solution. Although WP of priming solution did not influence the emergence rate of extremely high quality normal dent corn seeds, it reduced time to $50\%$ emergence (T50) and increased plumule weight. In contrast, the emergence rate of aged field corn was improved by seed priming at 0 MPa and plumule weight and $\alpha-amylase$ activity was enhanced. The optimum WP for both normal and aged sweet and super sweet corn seeds was between -0.3 and -0.6 Mpa. At the optimum WP emergence rate, $\alpha-amylase$ activity, and content of DNA and soluble protein increased, while T50 and leakage of total sugars and electrolytes reduced.

The Abdominal Approach for Epiphrenic Esophageal Diverticulum as an Alternative to the Thoracic Approach

  • Kim, Shin;Cho, Jong Ho
    • Journal of Chest Surgery
    • /
    • 제52권4호
    • /
    • pp.227-231
    • /
    • 2019
  • Background: There is no established surgical procedure for the treatment of epiphrenic esophageal diverticulum. The aim of this study was to compare the clinical outcomes of esophageal diverticulectomy using abdominal and thoracic approaches. Methods: We retrospectively reviewed 30 patients who underwent esophageal diverticulectomy through the thoracic or abdominal approach for an epiphrenic diverticulum at a single center between 1996 and 2018. We compared clinical outcomes, including the postoperative length of stay, time from the operation to oral feeding, leakage rate, and reoperation rate between the 2 groups. Results: The median age was 56 years. Of the 30 patients, 18 (60%) underwent diverticulectomy via the thoracic approach and 12 (40%) underwent the abdominal approach. The median hospital stay was 10 days (range, 5-211 days) in the thoracic approach group and 9.5 days (range, 5-18 days) in the abdominal approach group. The median time from the operation until oral feeding was 6.5 days (range, 3-299 days) when the thoracic approach was used and 5 days (range, 1-11 days) when the abdominal approach was used. In the thoracic approach group, the leakage rate was 16.67% and the reoperation rate was 27.78%. However, there were no cases of leakage or reoperation in the abdominal approach group. Conclusion: The abdominal approach for esophageal diverticulectomy is a feasible and appropriate alternative to the thoracic approach.

포름알데히드 누출에 따른 대피장소 선정 방안 (The Selter Selection Plan due to Formaldehyde Leakage)

  • 오승주;공하성
    • 대한안전경영과학회지
    • /
    • 제25권4호
    • /
    • pp.117-129
    • /
    • 2023
  • This study tested the effect on the toxicity of formaldehyde to select a shelter site due to formaldehyde leakage. As a result of the experiment, the range of ERPG-2 and 3 is between 2.2km and 9.6km, ASET is 6 minutes at 1km, 15 minutes at 3km, 22 minutes at 5km, and the lethality rate is 99.9% at 1km and 9% at 3km. In areas where refuge time is less than 15 minutes or the lethality rate is more than 2%, a shelter is installed. This is because if there are only a few evacuees, the evacuation time may take longer than the pre-movement time of 15 minutes or less specified in PD 7974-6:2004, and the lethality rate with the lowest number of deaths was calculated to be 2%. The shelter must be equipped with a hepa-filter, positive pressure equipment, air purifier, air respirator, goggles, chemical protective clothing type 4 and sufficient parking space must be secured to ensure the safety of evacuees.

식도암수술시 식도-위연결부 수기봉합과 기계봉합의 비교 (Comparison of Had-Sewn and Mechanical Esophagogastric Anastomosis After Esophageal Resection for Cancer)

  • 신재승;최영호;김광택;황재준
    • 대한기관식도과학회지
    • /
    • 제5권2호
    • /
    • pp.143-152
    • /
    • 1999
  • Background : the technical modality of esophagogastric anastomosis plays an important part in the factors leading to anastomotic leakage and stricture. Objective : The objective of this study was to compare the leakage and stricture rates between the different anastomosis techniques. Materials and Methods : A retrospective study was undertaken in the patients with esophageal cancer who underwent a esophagectomy. Hand-sewn anastomosis was performed in one layer with interrupted sutures(Manual group). The stapler group was divided into two subgroups, such as PCEEA group and Endo-GIA group. Results : The differences of preoperative patient profiles between the groups were not significant. Overall mortality fates were 5% in manual group, 5% in PCEEA group and 11.5% in Endo-GIA group. Fewer anastomotic leakage occurred in manual group(5%) than in PCEEA group(10%) or in Endo-GIA group(15.4%). The postoperative stricture rate was higher in PCEEA group(35%) than in manual group(5%) or in Endo-GIA group(0%) Conclusion : Statistically, there were no significant differences in the anastomotic leakage and stricture rates between the hand-sewn and mechanical anastomosis. But the stricture rate was lower in the group using the linear stapling device and the leakage rate was lower in the hand-sewn group than the other groups.

  • PDF

Fatigue crack effect on magnetic flux leakage for A283 grade C steel

  • Ahmad, M.I.M.;Arifin, A.;Abdullah, S.;Jusoh, W.Z.W.;Singh, S.S.K.
    • Steel and Composite Structures
    • /
    • 제19권6호
    • /
    • pp.1549-1560
    • /
    • 2015
  • This paper presents the characterization of fatigue crack in the A283 Grade C steel using the MMM method by identifying the effects of magnetic flux leakage towards the crack growth rate, da/dN, and crack length. The previous and current research on the relation between MMM parameters and fatigue crack effect is still unclear and requires specific analysis to validate that. This method is considered to be a passive magnetic method among other Non-Destructive Testing (NDT) methods. The tension-tension fatigue test was conducted with a testing frequency of 10 Hz with 4 kN loaded, meanwhile the MMM response signals were captured using a MMM instrument. A correlation between the crack growth rate and magnetic flux leakage produces a sigmoid shape curve with a constant values which present the gradient, m value is in the ranges of 1.4357 to 4.0506, and the y-intercept, log C in the ranges of $4{\times}10^{-7}$ to 0.0303. Moreover, a linear relation was obtained between the crack length and magnetic flux leakage which present the R-Squared values is at 0.830 to 0.978. Therefore, MMM method has their own capability to investigate and characterize the fatigue crack effects as a main source of fracture mechanism for ferrous-based materials.

Airtightness of Light-Frame Wood Houses built in Daejeon and Chungnam Area

  • Jang, Sang-sik;Ha, Been
    • Journal of the Korean Wood Science and Technology
    • /
    • 제45권2호
    • /
    • pp.147-158
    • /
    • 2017
  • Among the energy consumption in building, the heating energy takes the largest part. Therefore, it is important to minimize the heat energy loss in building for the reduction of overall energy use in construction. The most important points for the minimization of energy loss in building are insulation and airtightness. Especially, in wood houses, airtightness is very important for energy saving as well as increase of durability. However, the researches on airtightness of wood buildings have been started recently and are very deficient especially in Korea. In this study, air leakage properties and airtightness performance were evaluated for light-frame wood houses built in Daejeon and Chungnam area. Total 7 houses were evaluated, among which four houses (Case 1 to Case 4) were in the construction stage before interior finish and the other three houses (Case 5 to Case 7) were after completion of construction work. The tests for airtightness were conducted by pressurization-depressurization method, and the factors included in the measurements includes air leakage rate at 50 Pa (CMH50), air change rate at 50 Pa (ACH50), equivalent leakage area (EqLA) and EqLA per floor area. As a result of this study, key air leakage points in wood houses were found to be the gaps between floor and wall, the holes for wiring and plumbing, the double glasses windows and the entrance doors. The average value of ACH50 for the houses after completion of construction work was $3.5h^{-1}$ that was similar to Europe standard ($3.0h^{-1}$). ACH50 was proportional to EqLA per floor area but inversely proportional to the internal volume, the net floor area and the area of window.

절연유의 유속과 유온이 유동대전에 미치는 영향 (The Influence of Velocity and Temperature on Streaming Charging Tendeny of Insulting Oil)

  • 김명녕;강성화;임기조;강도열;김봉흡
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1988년도 춘계학술대회 논문집
    • /
    • pp.70-73
    • /
    • 1988
  • Influence of Velocity and Temperature on Streaming Electrification of Insulating Oil is investigated by injection method. Leakage current is increased slightly with increasing temperature in the temperature range 20 to $80^{\circ}C$ at low flow rate, however, it show a peak in the temperature 40 to $60^{\circ}C$ at high flow rate. Leakage current is also increased linearly with increasing flow rate in the flow rate range 1 - 31/min but thereafter, it is increased abruptly with increasing flow rate.

  • PDF

터보 펌프 고압 후로팅 링 실의 누설량 및 회전체 동역학적 특성 해석 (Leakage and Rotordynamic Analysis of High Pressure Floating Ring Seal in Turbo Pump)

  • 하태웅;이용복;김창호
    • 한국유체기계학회 논문집
    • /
    • 제4권3호
    • /
    • pp.29-38
    • /
    • 2001
  • The floating ring seal has the ability of minimizing clearance without the rubbing phenomenon. It is often used in the turbo pump units of liquid rocket engines due to its superior leakage performance. The exact prediction of the lock-up position of the floating ring, the leakage performance, and the rotordynamic coefficients of the seal is necessary to evaluate the rotordynamic performance of the turbo pump unit. The governing equations(which are based on the Bulk-flow Model) we solved by the Fast Fourier Transform method. The lock-up position, leakage flow rate, and rotordynamic coefficients are evaluated according to the geometric parameters of the floating ring seal.

  • PDF