• Title/Summary/Keyword: Lead determination

Search Result 290, Processing Time 0.021 seconds

Studies on Solvent Extraction and Flotation Technique Using Metal-Dithizone Complexes(II). Determination of Trace Elements in Water Samples by Solvent Sublation

  • 김영상;최윤석;최희선
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.10
    • /
    • pp.1036-1042
    • /
    • 1998
  • The preconcentration and determination of trace elements in water samples were studied by a solvent sublation utilizing dithizonate complexation. After metal dithizonates were formed, trace amounts of cadmium, cobalt, copper and lead were floated and extracted into small volume of a water-immiscible organic solvent on the surface of sample solution and determined in the solvent directly by GF-AAS. Several experimental conditions as formation condition of metal-dithizonate complexes, pH of solution, amount of dithizone, stirring time, the type and amount of surfactants, N2 bubbling rate and so on were optimized for the complete formation and effective flotation of the complexes. And also four kinds of light solvents were compared each other to extract the floated complexes, effectively. After the pH was adjusted to 4.0 with 5 M HNO3, 8.0 mL of 0.05% acetone solution of dithizone was added to 1.00 L water sample. The dithizonate complexes were flotated and extracted into the upper methyl isobutylketone (MIBK) layer by the addition of 2.0 mL 0.2% ethanolic sodium lauryl sulfate solution and with the aid of small nitrogen gas bubbles. And this solvent sublation method was applied to the analysis of real water samples and good results of more than 85% recoveries were obtained in spiked samples.

Relationship between porcine carcass grades and estimated traits based on conventional and non-destructive inspection methods

  • Lim, Seok-Won;Hwang, Doyon;Kim, Sangwook;Kim, Jun-Mo
    • Journal of Animal Science and Technology
    • /
    • v.64 no.1
    • /
    • pp.155-165
    • /
    • 2022
  • As pork consumption increases, rapid and accurate determination of porcine carcass grades at abattoirs has become important. Non-destructive, automated inspection methods have improved slaughter efficiency in abattoirs. Furthermore, the development of a calibration equation suitable for non-destructive inspection of domestic pig breeds may lead to rapid determination of pig carcass and more objective pork grading judgement. In order to increase the efficiency of pig slaughter, the correct estimation of the automated-method that can accommodate the existing pig carcass judgement should be made. In this study, the previously developed calibration equation was verified to confirm whether the estimated traits accord with the actual measured traits of pig carcass. A total of 1,069,019 pigs, to which the developed calibration equation, was applied were used in the study and the optimal estimated regression equation for actual measured two traits (backfat thickness and hot carcass weight) was proposed using the estimated traits. The accuracy of backfat thickness and hot carcass weight traits in the estimated regression models through stepwise regression analysis was 0.840 (R2) and 0.980 (R2), respectively. By comparing the actually measured traits with the estimated traits, we proposed optimal estimated regression equation for the two measured traits, which we expect will be a cornerstone for the Korean porcine carcass grading system.

Development of a Fluorescent Sensor Based on Resazurin and Hydrotalcite for the Determination of Ethanol in Alcoholic Beverages

  • Hong Dinh Duong;Juyeon Kim;Jong Il Rhee
    • Journal of Sensor Science and Technology
    • /
    • v.33 no.2
    • /
    • pp.70-77
    • /
    • 2024
  • In this study, a fluorescent ethanol sensor is developed to determine the ethanol concentration in the liquid phase. The sensor is developed using a complex of resazurin (RA)/resorufin (RO) and a hydrotalcite (HT) catalyst in a sol-gel matrix of methyltrimethoxysilane (MTMS) to produce a fluorescent ethanol-sensing membrane (RA/RO*HT membrane). The operation mechanism of the RA/RO*HT membrane is based on (i) the oxidation of ethanol to acetaldehyde and (ii) the reduction of RA to RO, through electron flows followed by EtOH ↔ HT ↔ RA/RO ↔ EtOH interactions. These possible redox reactions can lead to an increased fluorescence intensity of the RA/RO*HT membrane as the ethanol concentration increases. The RA/RO*HT membrane shows a linear detection range of 1-20 vol.% EtOH with limit of detection (LOD) of 0.178%. Additionally, the RA/RO*HT membrane has high sensitivity and accuracy for determining the alcohol content in several Korean alcoholic beverages.

A Study on Embankment Slope Management System (성토사면유지관리시스템 개발에 관한 연구)

  • Kim, Seung-Hyun;Kim, Hong-Gyun;Lee, Jung-Yup;Koo, Ho-Bon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.749-758
    • /
    • 2010
  • Embankment Slope (or Fill Slope) is defined as artificial slope formed by the filling of soil or rocks on the original ground. Recently a lot of embankment failures and collapse has occurred due to the increase of torrential rainfall and typhoons. Embankment collapse has lead to a great loss of lives and property therefore there is a need to establish a systematic embankment slope management system that will handle the maintenance and repair of risky embankment slopes. The objective of this study is to establish an "Embankment Slope Management Method" for embankment slopes located along national highways all over Korea. The method for field investigation of embankment slopes was recommended and the system for investment priority determination was also developed. The factors that lead to the collapse of embankment slopes caused by natural calamities were also determined through the initial survey of embankment slopes located along river fronts and mountainous areas.

  • PDF

Determination of Copper, Lead, Cadmium and Zinc in Water by Square Wave Polarography with Dithizone-Chloroform Extraction Method (디티존-클로로포름 抽出, 短形波폴라로그래피에 의한 물중의 구리, 납, 카드뮴 및 아연의 定量)

  • Su-Chan Moon
    • Journal of the Korean Chemical Society
    • /
    • v.19 no.6
    • /
    • pp.428-433
    • /
    • 1975
  • 500 ml of a sample water was extracted with 10 ml of 0.01 % dithizone-$CHCl_3$three times. When $CHCl_3$ layer was back extracted with 10 ml of 0.1 N HCl containing mercuric ion, the free metal ions come into aqueous layer. The aqueous layer was added with 2 ml of 2 N KCl and was washed with 10 ㎖ of $CHCl_3$two times in order to remove the trace dithizone, and then was recorded square wave polarogram. The concentration of copper, lead and cadmium can be determined up to 3 ppb and that of zinc up to 14 ppb with an error of 10 %.

  • PDF

Early-onset epileptic encephalopathies and the diagnostic approach to underlying causes

  • Hwang, Su-Kyeong;Kwon, Soonhak
    • Clinical and Experimental Pediatrics
    • /
    • v.58 no.11
    • /
    • pp.407-414
    • /
    • 2015
  • Early-onset epileptic encephalopathies are one of the most severe early onset epilepsies that can lead to progressive psychomotor impairment. These syndromes result from identifiable primary causes, such as structural, neurodegenerative, metabolic, or genetic defects, and an increasing number of novel genetic causes continue to be uncovered. A typical diagnostic approach includes documentation of anamnesis, determination of seizure semiology, electroencephalography, and neuroimaging. If primary biochemical investigations exclude precipitating conditions, a trial with the administration of a vitaminic compound (pyridoxine, pyridoxal-5-phosphate, or folinic acid) can then be initiated regardless of presumptive seizure causes. Patients with unclear etiologies should be considered for a further workup, which should include an evaluation for inherited metabolic defects and genetic analyses. Targeted next-generation sequencing panels showed a high diagnostic yield in patients with epileptic encephalopathy. Mutations associated with the emergence of epileptic encephalopathies can be identified in a targeted fashion by sequencing the most likely candidate genes. Next-generation sequencing technologies offer hope to a large number of patients with cryptogenic encephalopathies and will eventually lead to new therapeutic strategies and more favorable long-term outcomes.

A Regression-Based Approach for Central Warehouse Location Problem (중앙창고 입지선정을 위한 회귀분석기반 해법)

  • Yoo, Jae-Wook;Lee, Dong-Ju
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.32 no.2
    • /
    • pp.57-65
    • /
    • 2009
  • In continuous review inventory model, (${\varrho}$, ${\gamma}$) system, order quantity(${\varrho}$) and reorder point(${\gamma}$) should be determined to calculate inventory-related cost that consists of setup, holding, and penalty costs. The procedure to obtain the exact value of ${\varrho}$ and ${\gamma}$ is complex. In this paper, a regression analysis is proposed to get the approximate inventory-related cost without the determination of ${\varrho}$ and ${\gamma}$ in the case that the standard deviation(${\sigma}$) of the lead time demand is small or that the mean(${\mu}$) of the lead time demand is proportional to ${\sigma}$. To save inventory-related cost, central warehouses with (${\varrho}$, ${\gamma}$) system can be built. Central warehouse can provide some stores with products with the consideration of the tradeoff between inventory-related cost and transportation cost. The number and the location of central warehouses to cover all the stores are determined by a regression-based approach. The performance of the proposed approach is tested by using some computational experiments.

A Study on the Crops Pollution with Heavy Metal (농작물중(農作物中) 중금속오염도(重金屬汚染度)와 1일섭취량(日攝取量) 및 허용기준설정(許容基準設定)에 관(關)한 연구(硏究))

  • Yum, Yong-Tae;Bae, Eun-Sang;Yun, Bae-Joung
    • Journal of Preventive Medicine and Public Health
    • /
    • v.13 no.1
    • /
    • pp.3-12
    • /
    • 1980
  • Certain heavy metals which may lead peoples to poisonous status are widely used in industry and their uses have been increasing along with rapid industrialization of this country. Such an increasement of metal uses aggravates the status of environmental pollution affecting foodstuffs which are the most important life supporting factor of animal and humanbeing. Concerning the safety measures to minimize food-borne transmission of such hazardous metals, surveillance is the backbone of them and probably more so with a potential problem such as intoxication. Theoretically, this surveillance should include the determination of levels of heavy metal toxicants in foods, the determination of food consumption patterns and typical total diet, and the estimation of total load of the metal contaminant from all sources of exposure including air, water, and occupational sources. In recent year, actually, such estimates on the total daily intake of some heavy metals from foods have been made in several developed countries and a wide variation of date by season, locality, and research method was recognized. Also in this country, this kind of research data is vitally needed to make up for the serious shortage or lack of references to estimate the total amount of heavy metal intake of the people. In this study, a modification model for estimation of the total daily intake of cadmium copper, nickel, zinc, and lead through foods was applied and concentrations of the above metals in crops cultivated in this country were measured with atomic absorption spectro photometer to get the following results. 1. Level of heavy metal concentration in crops Generally, the levels of such metals in essential crops such as rice, cucumber, radish. chinese cabbage, apple, pear, grape, and orange are similar or lower than those in Japan and other developed countries. By the way, a striking result on cadmium concentration was increasement of its concentration in rice from $0{\sim}0.035ppm$ in 1970 to 0.11ppm in this study. However, the value is still far below the. Japanese Permissible Lebel of 1.0ppm. 2. Estimation of total daily intake per capita from foods A new model for estimation was devised utilizing levels of metal concentration in foods, amount of food consumed, and other food factors. Based on the above method, the daily intake of cadmium was estimated to be $70.53{\mu}g/man/day$ in average which was as high as the Limit Value of ILO/WHO(up to $71.4{\mu}g/man/day$). Also, 3.89mg of Zinc, 1.65mg of cuppor, 0.32mg of lead were given as the total daily intake per capita by this research. 3. Efficacy of washing or skinning to decrease the amount of metals in crops After washing the crops sufficiently with commercial linear alkylate sulfonate, the concentration of heavy metals could be reduced to $50{\sim}80%$ showing decreasement rate of $20{\sim}50%$. Also, after skinning the fruits, decreasement rate of the heavy metal concentration shelved $0{\sim}50%$.

  • PDF

Voltammetric Determination of Copper(II) Using Glassy Carbon Electrodes Modified with Nafion-DTPA-Glycerol

  • Park, Chan-Ju;Park, Eun-Heui;Chung, Keun-Ho
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2003.06a
    • /
    • pp.177-180
    • /
    • 2003
  • A glassy carbon electrode(GCE) modified with nafion-DTPA-glycerol was used for the highly selective and sensitive determination of a trace amount of Cu$\^$2+/. Various experimental parameters, which influenced the response of nafion-DTPA-glycerol modified electrode to Cu$\^$2+/, were optimized. The copper(II) was accumulated on the electrode surface by the formation of the complex in an open circuit, and the resulting surface was characterized by medium exchange, electrochemical reduction, and differential pulse voltammetry, A linear range was obtained in the concentration range 1.0${\times}$10$\^$-8/M∼1.0${\times}$10$\^$-6/M Cu(II) with 7 min preconcentration. Further, when an approximate amount of lead(II) is added to the test solution, nafion-DTPA-glycerol modified glassy carbon electrode has a dynamic range of 2 orders magnitude(1.0${\times}$10$\^$-9/M∼1.0${\times}$10$\^$-7/M). The detection limit(3 $\sigma$) was as low as 5.0${\times}$10$\^$-6/M(0.032ppb). The interferences from other metal ions could be reduced by adding KCN into the sample solutions. This method was applied to the determination of coppe,(II) in certified reference material(3.23${\times}$10$\^$-7/M, 21ppb), sea water(9.50${\times}$10/sup-7/M, 60ppb). The result agrees satisfactorily with the value measured by Korea Research Institute of Standard and Science.

  • PDF

Determination of a Trace Amount of Copper, Lead, Cadmium and Zinc in Water by Solvent Extraction and Square Wave Polarography (溶媒抽出-矩形波폴라로그래피에의 물중의 미량 구리, 납, 카드뮴 및 아연의 定量)

  • Moon Su-Chan
    • Journal of the Korean Chemical Society
    • /
    • v.21 no.5
    • /
    • pp.372-378
    • /
    • 1977
  • The following new techniques have been developed: (A); To a 500ml of sample water, it was adjusted pH 10 with ammonia-anmonium citrate, added 10ml of 1${\%}$ sodium diethyldithiocarbamate and extracted three times with 10ml of CHCl3. The extract was shaken with 10ml of 0.05N $HCl-4{\times}10^{-4}M\;HgCl_2$. The aqueous solution was added 2ml of 2N KCl and washed two times with 10ml of pure $CHCl_3$, and then recorded square wave polarograms. (B); To a 500ml of sample water adjusted pH 10 with ammonia-ammonium citrate, it was added 2ml of 1${\%}$ 8-hydroxyquinoline and extracted three times with 10ml $CHCl_3$. The separated $CHCl_3$ phase was shaken with 10ml of 0.2 N HCl. The aqueous solution was recorded polarograms directly. These methods can be used for determination of the ppb order of metal in water with an error of ${\pm}10{\%}$. The method (B) can not be used for the determination of zinc on account of the free 8-hydroxyquinoline.

  • PDF