• Title/Summary/Keyword: Lead acid battery

Search Result 162, Processing Time 0.032 seconds

Comparison of electrical characteristic between Lead-Acid Battery and Lithium-based Battery for Designing in NPPs (원전 비상전원 설계를 위한 납축전지 및 리튬계열전지 전기적 특성 비교)

  • Park, Seongyun;Kim, Gunwoo;Kim, Jonghoon;Park, Seongbeak
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.119-120
    • /
    • 2018
  • 국내 원자력 발전소의 비상전원공급을 위하여 대체교류디젤 발전기와 납축전지를 사용하고 있다. 납축전지는 온도, 방전 전류, 수명 및 안정성 등에서 리튬계열전지와 비교되고 있으며, 전기적 특성이 우수하고 안정성이 높은 리튬계열전지의 사용이 고려되고 있다. 본 논문은 원전의 비상전원 설계를 위하여 납축전지와 리튬계열전지의 전기적 특성을 비교 분석하였다.

  • PDF

C-rate based electrical characteristics and equivalent circuit modeling of 18650 cylindrical Li-ion battery for nuclear power plant application (원전 비상전원 적용성 판단을 위한 다양한 C-rate 기반 원통형 리튬이온 배터리의 전기적 특성분석 및 모델링)

  • Kim, Gunwoo;Park, Seongyun;Park, Jinhyeong;Kim, Jonghoon;Park, Sungbaek;Kim, Youngmi
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.667-674
    • /
    • 2019
  • The recent incidents of Nuclear Power Plant(NPP) gave rise to a total power outage caused by the loss of the functions of the off-site and the emergency power supply. Currently, emergency power supply of NPP have been taken into account by Li-ion batteries instead of existing lead-acid batteries. In order to judge the applicability of the cylindrical Li-ion battery, it is necessary to analysis the results of various electrical tests. This paper investigates the basic electrical characteristics test of three types of cylindrical batteries in order to select the most suitable battery and estimate state of battery through equivalent circuit model and propose method to solve the problem.

Battery State-of-Charge Estimation Using ANN and ANFIS for Photovoltaic System

  • Cho, Tae-Hyun;Hwang, Hye-Rin;Lee, Jong-Hyun;Lee, In-Soo
    • The Journal of Korean Institute of Information Technology
    • /
    • v.18 no.5
    • /
    • pp.55-64
    • /
    • 2020
  • Estimating the state of charge (SOC) of a battery is essential for increasing the stability and reliability of a photovoltaic system. In this study, battery SOC estimation methods were proposed using artificial neural networks (ANNs) with gradient descent (GD), Levenberg-Marquardt (LM), and scaled conjugate gradient (SCG), and an adaptive neuro-fuzzy inference system (ANFIS). The charge start voltage and the integrated charge current were used as input data and the SOC was used as output data. Four models (ANN-GD, ANN-LM, ANN-SCG, and ANFIS) were implemented for battery SOC estimation and compared using MATLAB. The experimental results revealed that battery SOC estimation using the ANFIS model had both the highest accuracy and highest convergence speed.

Low-Voltage-Stress AC-Linked Charge Equalizing System for Series-Connected VRLA Battery Strings

  • Karnjanapiboon, Charnyut;Jirasereeamornkul, Kamon;Monyakul, Veerapol
    • Journal of Power Electronics
    • /
    • v.13 no.2
    • /
    • pp.186-196
    • /
    • 2013
  • This paper presents a low voltage-stress AC-linked charge equalizing system for balancing the energy in a serially connected, valve-regulated lead acid battery string using a modular converter that consists of multiple transformers coupled together. Each converter was coupled through an AC-linked bus to increase the overall energy transfer efficiency of the system and to eliminate the problem of the unbalanced charging of batteries. Previous solutions are based on centralized and modularized topologies. A centralized topology requires a redesign of the hardware and related components. It also faces a high voltage stress when the number of batteries is expanded. Modularized solutions use low-voltage-stress, double-stage, DC-linked topologies which leads to poor energy transfer efficiency. The proposed solution uses a low-voltage stress, AC-linked, modularized topology that makes adding more batteries easier. It also has a better energy transfer efficiency. To ensure that the charge equalization system operates smoothly and safely charges batteries, a small intelligent microcontroller was used in the control section. The efficiency of this charge equalization system is 85%, which is 21% better than other low-voltage-stress DC-linked charging techniques. The validity of this approach was confirmed by experimental results.

A Study on the Improved Load Sharing rate in Paralleled Operated Lead Acid Battery by Using Microprocessor (마이크로 프로세서를 이용한 축전지의 병렬 운전 부하분담률 개선에 관한 연구)

  • 이정민
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.493-497
    • /
    • 2000
  • A battery is the device that transforms the chemical energy into the direct-current electrical energy without a mechanical process. Unit cells are connected in series to obtain the required voltage while being connected in parallel to organize capacity for load current. Because the voltage drop down in one set of battery is faster than in two one it may result in the low efficiency of power converter with the voltage drop and cause the system shutdown. However when the system being shutdown. However when the system being driven in parallel a circular-current can be generated,. It is shown that as a result the new batteries are heated by over-charge and over-discharge and the over charge current increases rust of the positive grid and consequently shortens the lifetime of the new batteries. The difference between the new batteries and old ones is the amount of internal resistance. In this paper we can detect the unbalance current using the microprocessor and achieve the balance current by adjusting resistance of each set, The internal resistance of each set becomes constant and the current of charge and discharge comes to be balanced by inserting the external resistance into the system and calculating the change of internal resistance.

  • PDF

Relationship on the lead exposure indices and symptoms by ALAD genotype in lead worker (연 노출 근로자들의 ALAD genotype에 따른 연 노출지표 및 증상과의 관련성)

  • Ahn, Kyu Dong;Lee, Jong Chun;Cho, Kwang Sung;Kim, Jin Ho;Lee, Sung Soo;Lee, Byung Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.2
    • /
    • pp.111-117
    • /
    • 2001
  • A cross-sectional study was performed to evaluate associations between lead biomarkers, lead-related symptoms, and ${\delta}$-aminolevulinic acid dehydratase (ALAD) genotype among 598 lead workers and 144 control office workers in storage battery industries, secondary smelting and litharge making industries. Lead inhibits the second enzymes, ALAD, in the heme synthesis pathway. ALAD gene, which codes for one of three isozymic proteins (termed ALAD1-1, ALAD1-2, and ALAD2-2), seems to modify the toxicokinetics of lead. The result as follows; The percents of total workers whose genotype of ALAD1-1 and ALAD1-2 were 88.4% and 11.6%, respectively. The zinc protoporphyrin in blood (ZPP) and ${\delta}$-aminolevulinic acid in urine (ALAU) of lead workers with ALAD1-2 were significantly lower than those of lead workers with ALAD1-1, but there were no significant difference between two genotype for blood lead, age, and work duration. The proportion of ALAD1-2 genotype in control office workers was 13.2%. The proportions of ALAD1-2 genotype of lead workers were 14.0%(their mean air lead level below $0.024mg/m^3$), 10.4%($0.025-0.049mg/m^3$), 11.8%($0.050-0.099mg/m^3$), and 9.4%(above $0.100mg/m^3$), respectively. In the logistic analysis of 15 lead related symptoms, 'arthralgia'(S7) symptom of ALAD1-2 was significantly lower (OR=0.481; 95% CI=0.248-0.932) than that of ALAD1-1, but 'feeling of irritation'(S11) of ALAD1-2 was significantly higher(OR=1.636; 95% CI=1.035-2.586) than that of ALAD1-1 after controlling possible confounder (blood lead, work duration, smoking and drinking habit).

  • PDF

Sodium Sulfur Battery for Energy Storage System (대용량 에너지 저장시스템을 위한 나트륨 유황전지)

  • Kim, Dul-Sun;Kang, Sungwhan;Kim, Jun-Young;Ahn, Jou-Hyeon;Lee, Chang-Hui;Jung, Keeyoung;Park, Yoon-Cheol;Kim, Goun;Cho, Namung
    • Journal of the Korean Electrochemical Society
    • /
    • v.16 no.3
    • /
    • pp.111-122
    • /
    • 2013
  • Sodium sulfur (NAS) battery is a high energy storage system (ESS). These days, as the use of renewable green energy like wind energy, solar energy and ocean energy is rapidly increasing, the demand of ESS is increasing and NAS battery is considered to be one of the most promising ESS. Since NAS battery has a high energy density(3 times of lead acid battery), long cycle life and no self-charge and discharge, it is a good candidate for ESS. A NAS battery consists of sulfur as the positive electrode, sodium as the negative electrode and ${\beta}$"-alumina as the electrolyte and a separator simultaneously. Since sulfur is an insulator, carbon felt should be used as conductor with sulfur and so the composition and property of the cathode could largely influence the cell performance and life cycle. Therefore, in this paper, the composition of NAS battery, the property of carbon felt and sodium polysulfides ($Na_2S_x$, intermediates of discharge), and the effects of these factors on cycle performance of cells are described in detail.

Economic Evaluation of Liquid Air Energy Storage (LAES) System (액화 공기 에너지 저장 기술(LAES)의 경제성 분석)

  • Ko, Areum;Park, Sung-Ho;Ryu, Ju-Yeol;Park, Jong-Po
    • New & Renewable Energy
    • /
    • v.16 no.1
    • /
    • pp.1-14
    • /
    • 2020
  • Liquid air energy storage (LAES) using gas liquefaction has attracted considerable attention because of its mature technology, high energy density, few geographical constraints, and long life span. On the other hand, LAES has not yet been commercialized and is being developed recently. Therefore, few studies have performed an economic analysis of LAES. In this study, the levelized cost of electricity was calculated and compared with that of other energy storage systems. As a result, the levelized cost of electricity of LAES was $371/MWh. This is approximately $292/MWh, $159/MWh, $118/MWh, and $3/MWh less than that of the LiCd battery, VRFB battery, Lead-acid battery, and NaS battery. In addition, the cost was approximately $62/MWh and $195/MWh more than that of Fe-Cr flow battery and PHS. Sensitivity analysis of the levelized cost of electricity according to the main economic factors was performed, and economic uncertainty analysis was performed through a Monte-Carlo simulation. The cumulative probability curve showed the levelized cost of electricity of LAES, reflecting price fluctuations in the air compressor cost, electricity cost, and standing reserve hourly fee.

The Study on the Controller for Supplying Stably Power with a Stand-Alone Photovoltaic/Wind/Small Generator Hybrid Power Generation System (독립형 태양광, 풍력, 소형발전기 복합시스템에서 안정적인 전력공급을 위한 컨트롤러에 관한 연구)

  • Choi, Byoung-Soo;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.4
    • /
    • pp.48-56
    • /
    • 2012
  • The object of this paper is the controller for supplying stably power in a separate house in which a hybrid electrical storage system with a stand-alone photovoltaic/wind power generation system and a small generator is applied. In the photovoltaic/wind hybrid power system used in the separate house, when only the battery is used in sunless days, the capacity of the battery is become larger. In particular, as in recent days, if cloudy days are frequent due to anomaly climate, it is difficult to estimate the number of sunless days. Accordingly, it is preferable to build the electrical storage system that numbers of sunshineless days are to be controlled and a shortage amount of the power generation capacity is to be handled by a small generator system. In order to supply stably power of new renewable energy such as solar to any separate houses, it is preferable to reduce the capacity of battery by decreasing the number of sunless days when estimating the capacity of battery and to drive the small generator for compensation of the power shortage. Such system needs components including inverters for photovoltaic and wind power generation system, batteries and controllers for automatically driving the small generator, based upon the nature of the stand-alone house, and it is preferable to use the controller having a simpler and higher stability by adopting the all-in-one scheme to facilitate its maintenance.

A study on renal function indices in lead exposed male workers (연폭로 남자 근로자들의 신기능 지표에 관한 연구)

  • Lee, Sung-Soo;HwangBo, Young;Ahn, Kyu-Dong;Lee, Byung-Kook;Kim, Joung-Soon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.28 no.2 s.50
    • /
    • pp.421-432
    • /
    • 1995
  • The influence of lead exposure on renal function was studied. Eighty nine lead exposed workers who worked in 2 storage battery factories, and seventy one control workers were chosen for this study. Blood lead(PbB) and zinc protoporphyrin in whole blood(ZPP) were selected as indicators of lead exposure. As indicators of renal function, urinary N-acetyl-$\beta$-D-glucosaminidase(NAG), blood urea nitrogen(BUN), serum creatinine(S-Cr), total protein in urine(U-TP),and serum uric acid(S-Ua) were selected. The results obtained were as follows: 1. While the mean values of lead exposure indicators of lead workers were significantly different from non-exposed ones, the mean values of NAG, U-TP, BUN and S-Cr of renal function indicators of exposed were also significantly different from non-exposed but their mean values were all within normal limits. 2. BUN, logarithmic U-TP, logarithmic NAG and S-Cr showed statistically significant correlation with PbB. 3. The proportion of workers whose values of renal function indicators were over the normal limits(NAG7.5 U/g Cr ; U-TP10.9 mg/dl ; BUN20 mg/dl ; S-Crl.2 mg/dl ; S-Ua7.0 mg/dl) by the level of lead absorption in terms of PbB and ZPP were calculated. The proportion of workers with over the normal limits of U-TP among total workers showed the dose-response relationship. When age is adjusted, U-TP showed significantly strong dose-response relationship with the level of PbB and ZPP.

  • PDF