• 제목/요약/키워드: Lead Screw

검색결과 71건 처리시간 0.029초

툴 체인지 방식 멀티 노즐 3D프린터의 설계 및 제작 (Design and Fabrication of Tool Change Multi-nozzle FDM 3D Printer)

  • 석익현;박종규
    • 한국기계가공학회지
    • /
    • 제20권2호
    • /
    • pp.38-44
    • /
    • 2021
  • To cater to the transition from single-color to multicolor/multi-material printing, this paper proposes a cartridge-replacing type multi-nozzle Fused Depositon Modeling(FDM) three-dimensional (3D) printer. In the test printing run, tool change failure/wobble/layer shift occurred. It was confirmed that improper support was the cause of this tool change failure. As a solution, spline and electromagnetic cartridges were designed. Wobble was caused by machine vibration and the motor stepping out. To minimize wobble, an additional Z-axis was installed, and the four-point bed leveling method was used instead of the three-point bed leveling method. The occurrence of layer shift was ascribed to the eccentricity of the Z-axis lead screw. Therefore, slit coupler was replaced with an Oldham type. In addition to the mechanical supplementation, the control environment was integrated to prevent accidents and signal errors due to wire connections. Before the final test printing run, a rectifier circuit was added to the motor to secure precise control stability. The final test printing run confirmed that the wobble/layer shift phenomenon was minimized, and the maximum error between layers was reduced to 0.05.

Wedge Shape Cage in Posterior Lumbar Interbody Fusion : Focusing on Changes of Lordotic Curve

  • Kim, Joon-Seok;Oh, Seong-Hoon;Kim, Sung-Bum;Yi, Hyeong-Joong;Ko, Yong;Kim, Young-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • 제38권4호
    • /
    • pp.255-258
    • /
    • 2005
  • Objective : Lumbar lordotic curve on L4 to S1 level is important in maintaining spinal sagittal alignment. Although there has been no definite report in lordotic value, loss of lumbar lordotic curve may lead to pathologic change especially in degenerative lumbar disease. This study examines the changes of lumbar lordotic curve after posterior lumbar interbody fusion with wedge shape cage. Methods : We studied 45patients who had undergone posterior lumbar interbody fusion with wedge shape cage and screw fixation due to degenerative lumbar disease. Preoperative and postoperative lateral radiographs were taken and one independent observer measured the change of lordotic curve and height of intervertebral space where cages were placed. Segmental lordotic curve angle was measured by Cobb method. Height of intervertebral space was measured by averaging the sum of anterior, posterior, and midpoint interbody distance. Clinical outcome was assessed on Prolo scale at 1month of postoperative period. Results : Nineteen paired wedge shape cages were placed on L4-5 level and 6 paired same cages were inserted on L5-S1 level. Among them, 18patients showed increased segmental lordotic curve angle. Mean increased segmental lordotic curve angle after placing the wedge shape cages was $1.96^{\circ}$. Mean increased disc height was 3.21mm. No cases showed retropulsion of cage. The clinical success rate on Prolo's scale was 92.0%. Conclusion : Posterior lumbar interbody fusion with wedge shape cage provides increased lordotic curve, increased height of intervertebral space, and satisfactory clinical outcome in a short-term period.

Is Titanium Mesh Cage Safe in Surgical Management of Pyogenic Spondylitis?

  • Heo, Won;Kang, Dong-Ho;Park, Kyung-Bum;Hwang, Soo-Hyun;Park, In-Sung;Han, Jong-Woo
    • Journal of Korean Neurosurgical Society
    • /
    • 제50권4호
    • /
    • pp.357-362
    • /
    • 2011
  • Objective : To report our experience with pyogenic spondylitis treated with anterior radical debridement and insertion of a titanium mesh cage and to demonstrate the effectiveness and safety of the use of a titanium mesh cage in the surgical management of pyogenic spondylitis. Methods : We retrospectively analyzed the clinical characteristics of 19 patients who underwent surgical treatment in our department between January 2004 and December 2008. The average follow-up period was 11.16 months (range, 6-64 months). We evaluated risk factors, cultured organisms, lab data, clinical outcomes, and radiographic results. Surgical techniques for patients with pyogenic spondylitis were anterior radical debridement and reconstruction with titanium mesh cage insertion and screw fixation. All patients received intravenous antibiotics for at least 6 weeks postoperatively, and some patients received oral antibiotics. Results : The infections resolved in all of the patients as noted by normalization of their erythrocyte sedimentation rates and C-reactive protein levels. The mean pain score on a Visual Analog Scale was 7.8 (range, 4-10) before surgery and 2.4 (range, 1-5) after surgery. The Frankel grade was improved by one grade in seven patients. After surgery, the average difference of the angle was improved about $6.96^{\circ}$ in all patients. At the last follow-up, the mean loss of correction was $4.86^{\circ}$. Conclusion : Anterior radical debridement followed by the placement of instrumentation with a titanium mesh cage may be a safe and effective treatment for selected patients with pyogenic spondylitis. This surgical therapy does not lead to recurrent pyogenic spondylitis.

인공치아의 즉시부하를 위해 새로이 개발된 인공치아 지대주(Satellite Abutment)의 광탄성 응력 분석 (PHOTOELASTIC STRESS ANALYSIS OF LOAD TRANSFER TO SATELLITE ABUTMENT AS AN IMMEDIATE ABUTMENT)

  • 박상규;이백수;;김부동
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제28권6호
    • /
    • pp.472-479
    • /
    • 2002
  • Since $Br^{\circ}anemark$ introduced the osseointegrated implants, they have been granted for useful methods for the restoration of oral function. The original $Br^{\circ}anemark$ protocol recommended long stress-free healing periods to achieve the osseointegration of dental implants. However, many clinical and experimental studies have shown that the osseointegration is no wonder in almost cases and that early and immediate loading may lead to predictable osseointegration. So we are willing to introduce the Satellite Abutment newly invented for immediate loading. We think that it will make the occlusal forces dispersed to surrounding bone and that we can restore the oral function immediately after implant installation not disturbing osseointegration. In case of using Satellite abutment, stress concentrated to bone contact area of implant was distributed not only fixation plate and screws but also superior, middle portion of implant and cortical layer of jaw bone. It was clearly decreased on the bone contact surfaces around dental implants. 1. Stress was decreased more than 76.5% when satellite straight abutment was used. 2. Stress was decreased more than 50% when satellite angled abutment was used. 3. The stress around dental implant was well distributed along the cortical bone surface and the fixation plate and screw. This study concludes that satellite abutment can be used as all immediate loading implant prothesis because it was possible to distribute periimplant occlusal stress through implant contact bone surface and cortical layer of jaw bone.

임플란트 고정체의 매식 경사에 따른 응력분석 (Stress analysis according to the different angulation of the implant fixture)

  • 이태엽;강동완
    • 구강회복응용과학지
    • /
    • 제18권4호
    • /
    • pp.321-329
    • /
    • 2002
  • Bending moments results from offset overloading of dental implant, which may cause stress concentrations to exceed the physiological capacity of cortical bone and lead to various kinds of mechanical failures. The purpose of this study was to compare the distributing pattern of stress on the finite element models with the different angulated placement of dental implant in mandibular posterior missing areas. The three kinds of finite element model, were designed according to 3 main configurations: Model 1(parallel typed placement of 2 fixtures), Model 2(15. distal angulated placement of one fixture on second molar area), Model 3(15. mesial angulated placement of one fixture on second molar area). The cemented crowns for mandibular first and second molars were made on the two fixtures (4mm 11.5). Three-dimensional finite element models by two fixtures were constructed with the components of the implant and surrounding bone. A 200N vertical static load were applied to the center of central fossa and the point 2mm apart from the center of central fossa on each model. The preprocessing, solving and postprocessing procedures were done by using FEM analysis software NISA/DISPLAY IV Version 10.0((Engineering Mechanics Research Corporation, USA). Von Mises stresses were evaluated and compared in the supporting bone, fixtures, and abutment. The results were as following : (1) Under the point loading at the central fossa, the direction of angulated fixture affected the stress pattern of implants. (2) Under the offset loading, the position of loading affected more on the stress concentration of implants compare to the angulated direction of implants. The results had a tendency to increase the stress on the supporting bone, fixture and screw under the offset loads when the placement angulation of implant fixture is placed toward mesial or distal direction. In designing of the occlusal scheme for angulated placement, placing the occlusal contacts axially during chewing appears to have advantages in a biomechanical viewpoint.

캠구동 방식을 적용한 자동차 공조시스템용 전자팽창밸브의 성능에 관한 연구 (Studies on the Performance of a Cam Driving Electronic Expansion Valve for Vehicles)

  • 김성철
    • 한국산학기술학회논문지
    • /
    • 제17권9호
    • /
    • pp.732-736
    • /
    • 2016
  • 공조시스템을 구성하는 핵심 부품들의 설계 방향은 효율 향상 및 고생산성 측면을 둘 다 고려하는 것이다. 이러한 핵심부품 중의 하나인 팽창장치는 증발 부하, 압축 용량 및 응축 능력에 따라 냉매의 유량을 조절한다. 본 연구에서는 자동차용 공조시스템을 대상으로 하여 현 냉매인 R134a와 더불어 향후 대체냉매의 하나인 고압 $CO_2$의 사용이 가능한 겸용 전자팽창밸브가 개발되었다. 이 전자팽창밸브는 저 비용 및 고 생산성을 위해 기존 방식과는 달리 편심형 캠구동 방식이 채택되었다. 고안된 설계안을 바탕으로 수치해석을 이용하여 고압 조건에서의 내압성능과 밸브 개도에 따른 유량성능을 각각 평가하였다. 최대작동 압력 조건에서 98MPa의 최대응력을 보이며 탄성영역 이내의 변형을 나타내었다. 파괴압력 조건에서는 233 MPa의 최대응력을 보여 소성변형이 일어나지만 파괴가 일어나지 않는 것으로 예측되었다. 밸브 개도에 따라 유량이 증가하며, $CO_2$ 냉매와 R134a 냉매 적용시 각각 550 kg/h, 386 kg/h의 최대 유량을 나타내었다. 또한 R134a에 대한 내압 및 유량성능실험은 해석결과와 비교적 잘 일치함을 알 수 있었다.

냉동 냉면류의 제조공정별 미생물학적 위해요소 평가 (Microbial Hazard Analysis of the Manufacturing Processes for Frozen Korean Cold Noodle, Naengmyeon)

  • 김유정;김혜진;임영은;양혜걸;박슬기;정진숙;엄애선
    • 급식외식위생학회지
    • /
    • 제3권1호
    • /
    • pp.38-44
    • /
    • 2022
  • This study investigated the microbiological hazards in the manufacturing processes of Naengmyeon. Sanitary indicative bacteria, such as aerobic plate counts and coliforms as well as pathogenic bacteria, were examined from raw materials, manufacturing processes, working area, 17 utensils and equipment. The aerobic plate counts for raw materials and arrowroot starch estimated as 0.77±0.68~5.02±0.28 and 5.02±0.28 log CFU/g, respectively. Coliforms were detected from wheat flour, buckwheat flour, and potato starch. Staphylococcus aureus was detected to be 0.61±1.06 log CFU/g in wheat flour and 0.20±0.35 log CFU/g in buckwheat flour. During the manufacturing process, aerobic plate counts for kneading process were 4.54±0.34 log CFU/g. But after the press out and heat process, contamination of aerobic plate counts and coliforms decreased and remained at a low level until the release process. Aerobic plate counts before washing disinfection of screw were 3.28±0.62 log CFU/100 cm2, the level of which was high in utensils and equipment that had contact with employees or water. These results represent not only an important indicator for the hygienic level but also a scientific basis for analyzing biological hazards, which lead to the introduction of HACCP for the production of safe and hygienic cold noodles processed by manufacturers.

비확공성 전향적 상완골 금속정 고정술후 견관절 기능에 대한 임상적 및 방사선학적 평가: 초음파를 이용한 회전근 개 추시관찰 (Clinical and Radiographic Outcome of Shoulder Function after Unreamed Antegrade Intramedullary Nailing for Humerus Fracture: Ultrasonographic Evaluation for Rotator Cuff Integrity)

  • 백승훈;최창혁
    • 대한정형외과 초음파학회지
    • /
    • 제6권1호
    • /
    • pp.1-9
    • /
    • 2013
  • 목적: 상완골 골절에 대한 비확공성 전향적 금속정 내고정술 시행 후, 초음파을 이용하여 회전근 개 상태 및 영향 인자를 객관적으로 평가하고, 초음파 검사의 유용성을 확인하였다. 대상 및 방법: 상완골 골절로 골수강 내 금속정 내고정술을 시행받고 견관절의 초음파 검사를 시행한 17례를 연구 대상으로 하였다. 평균 연령은 $55.7{\pm}18.6$세였으며, 최초 수술 후 평균 추시 기간은 $43.5{\pm}32.2$개월이었다. 전 례에서 술중 회전근개 상태를 확인하였고, 4례(24%)에서 피부절개 후 회전근 개의 파열이 관찰되어 금속 봉합나사못을 이용하여 단열 봉합술을 시행하였다. 임상적 평가는 visual analogue scale (VAS), 운동범위, Korean Shoulder Scoring System (KSS) 및 American Shoulder and Elbow Society (ASES) 점수를 측정하였다. 회전근개의 상태에 대한 초음파 검사를 시행하였고, 견관절 기능에 영향을 미칠 수 있는 방사선학적 유합 시기, 금속정 근위 첨부 돌출 및 근위 교합 나사의 이동을 평가하였다. 금속정 근위 첨부 돌출에 대해서는 방사선학적 검사와 함께 초음파적 검사도 병행하였다. 결과: 최종 추시시 VAS는 평균 $1.65{\pm}1.84$, 운동 범위는 전방 굴곡 평균 $137.0{\pm}33.5^{\circ}$, 외회전 평균 $43.5{\pm}12.7^{\circ}$, 내회전 평균 $16.4{\pm}2.0^{\circ}$이었다. KSS점수는 평균 $79.6{\pm}20.7$점이었으며, ASES점수는 평균 $83.7{\pm}17.0$점이었다. 방사선학적 평가상 전례에서 골유합을 얻었으며, 골유합 기간은 평균 $3.4{\pm}1.3$개월이었으며, 근위 교합 나사의 이동이 6례(35%) 관찰되었다. 견관절 초음파 검사상 회전근 개는 정상 8례(47%), 굴곡변화 4례(24%) 및 부분파열 5례(29%)가 관찰되었으나 완전파열은 관찰되지 않았다. 금속정 첨부 돌출은 방사선 검사상 8례(47%), 초음파 검사상 총 11례(65%)에서 관찰되었고, 고령의 환자에서 호발하였다(p=0.038). 회전근 개의 굴곡 변화 및 부분파열은 첨부 돌출과 관련이 있었으나(p=006), 술전 파열의 봉합여부와는 관련이 없었다(p>0.05). 결론: 금속정 삽입술시 회전근 개 손상을 피하기 위하여 금속정 첨부의 연골하골 내 적절한 함입을 요하며, 초음파를 이용한 경과 관찰은 단순 방사선 검사상 파악하기 곤란한 금속정 첨부의 돌출 및 회전근 개 손상을 확인할 수 있는 유용한 진단 및 평가 도구가 될 수 있을 것으로 판단된다.

  • PDF

$NaClO_2(s)$와 탄소 분산형 촉매를 이용한 저온에서의 $NO_x$$SO_2$ 동시 제거 (Simultaneous Removal of $NO_x$ and $SO_2$ through the Combination of Sodium Chlorite Powder and Carbon-based Catalyst at Low Temperature)

  • 변영철;이기만;고동준;신동남
    • 대한환경공학회지
    • /
    • 제33권1호
    • /
    • pp.39-46
    • /
    • 2011
  • $250{\sim}400^{\circ}C$ 범위에서 $NO_x$ 제거를 위해 운영되는 선택적 촉매 환원법의 반응 온도를 $200^{\circ}C$ 이하로 낮추기 위해서는 NO를 $NO_2$로 산화시키는 전처리 공정을 필요로 한다. 이번 연구에서는 분말 $NaClO_2(s)$를 이용하여 NO를 $NO_2$로 산화시킨 후, 탄소 분산형 촉매를 이용한 저온에서의 $NO_x$, $SO_2$ 동시 제거에 관한 실험실 규모 실험과 제철소 소결 공장에서 실제 배기가스를 이용하는 bench 규모 실험을 진행하였다. 실험실 규모 실험에서는 반응기에 $NaClO_2(s)$ (2.4~3.6 g)를 충진 하여 $NO_x$ 200 ppm, $SO_2$ 75 ppm, $H_2O$ 10%, $O_2$ 15%의 모사가스(2.6 L/min)를 통과시켰으며, $NaClO_2(s)$와 반응 후의 모사가스를 탄소 분산형 촉매가 충진 된 반응기(공간 속도 = $2,000hr^{-1}$)로 주입하였다. bench 규모 실험에서는 $50Nm^3/hr$의 배기가스 유량에 screw feeder로 $NaClO_2(s)$ 분말을 주입하여 NO를 $NO_2$로 산화 시킨 후, $1,000hr^{-1}$ 탄소 분산형 촉매를 통과하여 $NO_x$ 제거 가능성을 확인하였다. 실험실 규모와 bench 규모 실험 모두 $SO_2$를 측정하며 $NO_x$, $SO_2$ 동시 제거 가능성을 확인하였다. 그 결과 실험실 규모와 bench 규모 실험 모두 $NaClO_2(s)$에 의하여 NO가 $NO_2$로 산화되었고, 이를 결합한 탄소 분산형 촉매에서 90% 이상의 $NO_x$, $SO_2$ 제거 효율을 나타내는 것을 확인하였다. 이상의 실험 결과로부터 $NaClO_2(s)$와 탄소 분산형 촉매의 결합은 저온에서 $NO_x$$SO_2$를 동시에 제거할 수 있음을 알 수 있었다.

미세 물 흐름 측정장치의 개발과 상아세관액의 수력학에의 응용 (DEVELOPMENT OF NANO-FLUID MOVEMENT MEASURING DEVICE AND ITS APPLICATION TO HYDRODYNAMIC ANALYSIS OF DENTINAL FLUID)

  • 이인복;김민호;김선영;장주혜;조병훈;손호현;백승호
    • Restorative Dentistry and Endodontics
    • /
    • 제33권2호
    • /
    • pp.141-147
    • /
    • 2008
  • 본 연구의 목적은 나노리터 수준의 물 흐름을 계측할 수 있는 장치를 개발하고, 상아질의 물 투과성을 측정하여 치아과민증 치료제와 상아질 접착제의 상아세관 밀폐효과를 알아보고자 하였다. 본 연구에서 제작한 미세흐름 측정장치는 첫째, 물의 흐름을 감지하는 모세관과 광 센서부, 둘째 물의 흐름을 추적하는 서보모터와 구동부, 셋째, 모터의 회전을 측정하여 물의 이동량으로 변환하는 엔코더와 컴퓨터 기록장치 등 세 부분으로 구성되어 있다. 본 장비를 이용하여 교합 면이 절단되어 노출된 상아질의 물 투과도와 치아과민증 치료제인 BisBlock과 자가부식형 상아질접착제인 Clearfil SE bond의 상아질 밀폐효과를 측정하여 다음과 같은 결과를 얻었다. 1. 나노리터 수준의 물 흐름을 측정할 수 있는 장치를 제작하였고, 이를 이용하여 상아질의 물 투과도를 측정할 수 있었다. 2. 삭제 후 노출 연마된 상아질은 0.84 - 15.2 nL/s의 물 투과도를 보였고 Oxalate 제재인 BisBlock 이나 자가부식형 접착제 Cleafil SE bond 적용 시 투과도가 39.8 - 89.6% 감소하였다.