• 제목/요약/키워드: Lead Length

검색결과 497건 처리시간 0.022초

자동차 정비업체 도장공정의 작업환경 및 근로자 노출 실태에 관한 연구 (A Study of Working Environment for Automotive Painting in Auto Repair Shops and Workers' Exposure to Hazardous Chemicals)

  • 심상효;정춘화;임진숙;이형구;김윤신
    • 한국환경보건학회지
    • /
    • 제35권3호
    • /
    • pp.153-161
    • /
    • 2009
  • The purpose of this paper is to evaluate 1) blood lead levels of workers at auto repair shops as Biological Exposure Indices (BEI) of toxic substances such as lead and toluene that are produced during automotive painting process, 2) the differences depending on personal characteristics of workers who have been exposed to toluene by using urine hippuric acid concentration as a marker and 3) the correlation between the concentration of hazardous chemicals in each workplace and the BEL. All subjects were male with a mean age of 36.2 years. In terms of age, most were in the 30 to 40 age group (13 persons, 48.1%). In relation to the length of work experience, the highest proportion had experience of 10 years of less (18 persons, 66.7%). Twenty three workers were cigarette smokers (85.2%) while 4 (14.8%) were non-smokers. In addition, more than 80% of the workers drank alcohol. Dust concentration and toluene exposure during automotive painting showed no significant difference with age, length of work experience, smoking and drinking while a significant difference (p<0.05) has been detected between lead concentration and smoking. The geometric mean of dust concentration, lead concentration and toluene concentration were $0.38mg/m^3,\;0.0021mg/m^3$ and 1.08ppm respectively. In addition, the geometric mean of blood lead levels and urine hippuric acid concentration were $1.70{\mu}g/dl$ and 0.25g/g respectively, which were lower than the standard levels suggested by the Ministry of Labor. To determine the influential factors on blood lead and urine hippuric acid concentrations, a correlation analysis has been conducted with variables of air, lead and toluene concentrations, age, length of work experience and amount of cigarette smoking. According to the analysis, a relatively high correlation (p<0.01) has been observed between air lead concentration and biological sample concentration.

Optimization of Peltier Current Leads Cooled by Two-Stage Refrigerators

  • Jeong, Eun-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제14권3호
    • /
    • pp.94-101
    • /
    • 2006
  • A theoretical investigation to find thermodynamically optimum design conditions of conduction-cooled Peltier current leads is performed. A Peltier current lead (PCL) is composed of a thermoelectric element (TE), a metallic lead and a high temperature superconductor (HTS) lead in the order of decreasing temperature. Mathematical expressions for the minimum heat flow per unit current crossing the TE-metal interface and the minimum heat flow per unit current from the metal lead to the joint of the metal and the HTS leads are obtained. It is shown that the temperature at the TE -metal interface possesses a unique optimal value that minimizes the heat flow to the joint and that this optimal value depends on the material properties of the TE and the metallic lead but not the joint temperature nor electric current. It is also shown that there exists a unique optimal value for the joint temperature between the metal and the HTS leads that minimizes the sum of the power dissipated by ohmic heating in the current leads and the refrigerator power consumed to cool the lead, for a given length of the HTS.

표면실장용 IC 패키지 솔더접합부의 열피로 수명 예측 (A prediction of the thermal fatigue life of solder joint in IC package for surface mount)

  • 윤준호;신영의
    • Journal of Welding and Joining
    • /
    • 제16권4호
    • /
    • pp.92-97
    • /
    • 1998
  • Because of the low melting temperature of solder, each temperature cycle initiates an irrecoverable creep deformation at the solder interconnection which connects the package body with the PCB. The crack starts and propagates from the position where the creep deformation is maximized. This work has tried to compare and analyze the thermal fatigue life of solder interconnection which is affected by the lead material, the size of die pad, chip thickness, and interface delamination of 48-Pin TSOP under the temperature cycle ($0^{\circ}C$~1$25^{\circ}C$). The crack initiation position and thermal fatigue life which are calculated by using FEA method are well matched with the results of experiments. The thermal Fatigue life of copper lead frame is extended around 3.6 times longer than that of alloy 42 lead frame. It is maximized when the chip size is matched with the length of the lead. It tends to be extended as the thickness of chip got thinner. As the interfacial delamination between die pad and EMC is increased, the thermal fatigue life tends to decrease in the beginning of delamination, and increase after the delamination grew after 45% of the length of die pad.

  • PDF

혈장 중 납의 만성독성 지표로의 활용에 관한 연구 (The Study on Possibility of Use of Lead in Plasma as a Chronic Toxicity Biomarker)

  • 이성배;임철홍;김남수
    • 한국산업보건학회지
    • /
    • 제29권2호
    • /
    • pp.195-207
    • /
    • 2019
  • Objectives: This study was performed to confirm whether plasma lead can be used as a chronic biomarker for the biological monitoring of exposure to lead. Methods: Lead concentrations in 66 plasma samples from retired lead workers (G.M. 60.25 years, Median 61.00 years) and 42 plasma samples from the general population (G.M. 53.76 years, Median 56.50 years) were measured using ICP/Mass. Tibia, whole blood, hemoglobin, hematocrit, and blood zinc protophorphyrin (ZPP) concentrations and urinary ${\delta}$-aminolevulinic acid (${\delta}-ALA$) were measured for correlation analysis with plasma lead. Results: The geometric mean concentration of lead in plasma was $0.23{\mu}g/L$ for the retired lead workers and $0.10{\mu}g/L$ for the general population sample. A simple correlation analysis of biomarkers showed that plasma lead concentration among the retired lead workers was highly correlated with lead concentration in the tibia and with blood lead concentration, and the plasma lead concentration among the general population correlated with ZPP concentration in the blood. The lead concentration in the tibia and the lead concentration in the whole blood increased with length of working period. As the period in the lead workplace increased, the ratio of lead in plasma to lead concentration in whole blood decreased. Conclusion: This study confirmed the possibility of a chronic biomarker of lead concentration in blood plasma as a biomarker. In the future, comparative studies with specific indicators will lead to more fruitful results.

1000A급 고온초전도 전류인입선 제조 및 통전특성 분석 (Fabrication and properties of 1000A class HTS current lead)

  • 박성창;유재무;고재웅;김해두;김철진
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 2000년도 High Temperature Superconductivity Vol.X
    • /
    • pp.226-229
    • /
    • 2000
  • Long lengths (<100m) of BSCCO 2223 tapes were fabricated of optimal process. We have I$_c$${\sim}$22A, J$_c$${\sim}$22,000A/cm$^2$(77K, 0T) at last heat treatment, and then prototype 1000A class current lead (length ${\sim}$50cm) fur HTS applications was fabricated using these tapes. Surface of current lead except both end part (${\sim}$1cm) was clothing with fiber glass. Also the transportation properties and thermal loss was studied on prototype 1000A class current lead.

  • PDF

Green flow injection spectrophotometric system for lead ion (II) evaluation in vegetables samples using new azo reagent

  • Fatimah Lateef Al-Zubaidi;Khdeeja Jabbar Ali
    • 분석과학
    • /
    • 제36권1호
    • /
    • pp.1-11
    • /
    • 2023
  • A new, sensitive, and reliable flow injection methodology was investigated for the determination of lead ion (II) in vegetables' samples using a laboratory-prepared reagent 2-[(6-methoxy-2-benzothiazoly)azo]-4-methoxy phenol (6-MBTAMP). Infrared spectroscopy, UV-visible spectrophotometry, Energy dispersive X-ray spectroscopy (EDX), Elemental Analysis (CHN), nuclear magnetic resonance spectroscopy 1HNMR, and 13CNMR techniques were used to characterize the reagent and lead (II) complex. The method is based on lead ion (II) reacting with the reagent (6-MBTAMP) in a neutral solution to produce a green-red complex with a maximum absorbance at 670 nm. The optimum conditions, such as flow rate, lead ion (II) volume, reagent volume, medium pH, reagent concentration, and reaction coil length were thoroughly examined. The limits of detection (LOD) and quantification (LOQ) were determined to be 0.621 mg·L-1 and 2.069 mg·L-1 , respectively, while Sandell's sensitivity was determined to be 0.345 ㎍·cm-2.

전도냉각형 펠티어 전류도입선의 최적화 (Optimization of Conduction-cooled Pottier Current Leads)

  • 정은수
    • 설비공학논문집
    • /
    • 제17권8호
    • /
    • pp.764-771
    • /
    • 2005
  • A theoretical investigation for optimization of conduction-cooled Peltier current leads is undertaken. A Pottier current lead (PCL) is composed of a thermoelectric element (TE), a metallic lead and a high Tc superconductor (HTS) lead in the order of decreasing thermoelectric tempera ture. Mathematical expression for the minimum heat flow per unit current crossing the TE metal interface and that flowing from the metal lead to the joint of the metal and the HTS leads are obtained. It is shown that the temperature at the TE-metal interface possesses a unique optimal value that minimizes the heat flow to the joint and that this optimal value depends on the material properties of the 73 and the metallic lead but not the joint temperature nor electric current. It is also shown that there exists a unique optimal value for the joint temperature between the metal and the HTS leads that minimizes the sum of the power dissipated by ohmic heating in current leads and the refrigerator power consumed to cool the lead, for a given length of the HTS.

Research on a novel shear lead damper: Experiment study and design method

  • Chong, Rong; Wenkai, Tian;Peng, Wang;Qingxuan, Shi
    • Steel and Composite Structures
    • /
    • 제45권6호
    • /
    • pp.865-876
    • /
    • 2022
  • The slit members have lower strength and lower stiffness, which might lead to lower energy dissipation. In order to improve the seismic performance of the slit members, the paper proposes the shear lead damper, which has stable performance and small deformation energy dissipation capacity. Therefore, the shear lead damper can set in the vertical silts of the slit member to transmit the shear force and improve energy dissipation, which is suitable for the slit member. Initially, the symmetrical teeth-shaped lead damper was tested and analyzed. Then the staggered teeth-shaped lead dampers were developed and analyzed, based on the defect analysis and build improvements of the symmetrical specimen. Based on the parameter analysis, the main influence factors of hysteretic performance are the internal teeth, the steel baffles, and the width and length of damper. Finally, the theoretical analysis was presented on the hysteretic curve. And the skeleton curve and hysteresis path were identified. Based on the above theoretical analysis, the design method was proposed, including the damping force, the hysteresis model and the design recommendations.

(s, S) Spare Part Inventory System

  • Park, Young-Taek
    • 품질경영학회지
    • /
    • 제14권2호
    • /
    • pp.21-27
    • /
    • 1986
  • This paper deals with a continuous review (s,S) spare part inventory system. The distributions of service life of each part and the replenishment lead time are assumed to be exponential. Assuming that there is never more than a single order outstanding, we obtain the average annual cost of operating the inventory system. If the length of stockout period is small enough to be neglected compared to the length of operating period, the optimal operating policy variables minimizing the cost rate can be calculated iteratively. For the case of one-for-one ordering (that is, s=S-1), an exact cost rate, and a closed form decision rule minimizing the cost rate are obtained for a more general situation in which more than one order is allowed to be outstanding and the distribution of the replenishment lead time is general.

  • PDF

확장계수를 적응한 기둥의 유효좌굴길이 계수 산정 (Evaluation of Effective Length Factor by Using an Amplification Factor)

  • 최동호;유훈;신재인;김성연
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2007년도 정기 학술대회 논문집
    • /
    • pp.369-374
    • /
    • 2007
  • For a stability design of steel frames, AISC-LRFD specification recommend to use Alignment Chart and story-based methods in order to determine an effective budding length. Recently, elastic buckling analysis, which is the method that calculate the effective length of members using eigenvalue of the overall structure, has been widely used in practical design of steel frames because this method can be performed effectively and automatically by computers. However, it can in some cases lead to unexpectedly large effective length in column having small axial forces. Therefore, this paper propose a method using elastic buckling analysis, which estimate a proper effective buckling length for all members having a small axial force. For verification of proposed method, it is compared with system based approach and stiffness distribution factor method. As a result, proposed method can rationally solve a problem in some case of column having small axial force. Also, adoption range for proposed method is established.

  • PDF