• Title/Summary/Keyword: Lateral-type

Search Result 1,274, Processing Time 0.026 seconds

The Biomechanical Analysis of Two and Half Rotation Technic of Penche in Rhythmic Gymnastics (리듬체조 퐁쉐 2회전 1/2턴 기술의 역학적 분석)

  • Seo, Se-Mi;Ryu, Ji-Seon;Kim, Tae-Sam
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.3
    • /
    • pp.269-279
    • /
    • 2011
  • This study was analyzed the characteristics on the stability of posture while conducting a through two and half rotation technic of pench$\acute{e}$ in rhythmic gymnastics. Two rhythmical gymnastics player(LKH and SSJ) who is a member of the national team were selected, and for obtain the kinematic and kinetic variables were used a ProReflex MCU 240 infrared camera(Qualisys, Sweden) and a Type9286A force platform(Kistler, Switzerland). The mechanical factors were computed by using Visual3D program and Matlab R2009a. During the landing and rotation phase the results showed following characteristics; 1) In medial-lateral and horizontal displacement of the support foot, LKH showed smaller movement than SSJ, but SSJ showed smaller movement than LKH in swing foot. LKH showed bigger movement in medial-lateral axis of COP and vertical axis of COG, but SSJ showed bigger movement in horizontal axis of COP and medial-lateral axis of COG. 2) SSJ showed bigger maximum horizontal and vertical velocity at P1 and P2 than LKH. 3) In the inclination angle of COP and COG, SSJ showed smaller change than LKH, but within medial-lateral tilt of the shoulder, LKH performed rotation motion in horizontal position than SSJ. There was no differences in each force components during rotation, but on landing phase, the results showed a characteristic that SSJ exerted bigger breaking force and vertical force than LKH.

Inelastic Buckling Behavior of Simply Supported I-Beam under Transverse Loading (횡방향 하중을 받는 I형강 단순보의 비탄성 좌굴거동)

  • Lee, Dong Sik;Oh, Soon Taek
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.1 s.68
    • /
    • pp.155-167
    • /
    • 2004
  • In this paper, the inelastic buckling behavior of the beam under uniform bending was investigated using the energy-based method, which can tackle problems in fourth order eigenvalue. The pattern of residual stress was not available to satisfy the I-sections manufactured in Korea. however; therefore, the well-known polynomial and simplified pattern of residual stress was adopted in this study. The inelastic lateral-distortional buckling behavior of the beam with I-sections manufactured in Korea was investigated. The study was then extended to the inelastic lateral-torsional buckling of the beam by minimizing the out-of-plane web distortion. The inelastic lateral-torsional buckling results obtained in this paper were compared with the prediction of allowable bending stress given in the Korean steel designers' manual (1995). Results showed that the importance of inelastic lateral-distortional buckling did not arise for beams under uniform bending. Likewise, the design method in KSDM (1995) was proven to bo too conservative for intermediate and short spans of beams without intermediate bracing.

Seismic responses of base-isolated nuclear power plant structures considering spatially varying ground motions

  • Sayed, Mohamed A.;Go, Sunghyuk;Cho, Sung Gook;Kim, Dookie
    • Structural Engineering and Mechanics
    • /
    • v.54 no.1
    • /
    • pp.169-188
    • /
    • 2015
  • This study presents the effects of the spatial variation of ground motions in a hard rock site on the seismic responses of a base-isolated nuclear power plant (BI-NPP). Three structural models were studied for the BI-NPP supported by different number of lead rubber bearing (LRB) base isolators with different base mat dimensions. The seismic responses of the BI-NPP were analyzed and investigated under the uniform and spatial varying excitation of El Centro ground motion. In addition, the rotational degrees of freedom (DOFs) of the base mat nodes were taken to consider the flexural behavior of the base mat on the seismic responses under both uniform and spatial varying excitation. Finally, the seismic response results for all the analysis cases of the BI-NPP were investigated in terms of the vibration periods and mode shapes, lateral displacements, and base shear forces. The analysis results indicate that: (1) considering the flexural behavior of the base mat has a negligible effect on the lateral displacements of base isolators regardless of the number of the isolators or the type of excitation used; (2) considering the spatial variation of ground motions has a substantial influence on the lateral displacements of base isolators and the NPP stick model; (3) the ground motion spatial variation effect is more prominent on lateral displacements than base shear forces, particularly with increasing numbers of base isolators and neglecting flexural behavior of the base mat.

Influence of Four Types of Steering Assistive Devices on Driving Performance: Comparison of Normal and Disabled People with and without Driver's License (4가지 선회보조 장치가 운전 성능에 미치는 영향: 장애 유무와 운전면허 유무에 따른 비교)

  • Song, Jeongheon;Kim, Yongchul
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.1
    • /
    • pp.32-42
    • /
    • 2017
  • The aim of this study was to evaluate driving performance of Healthy and disabled groups (with or without driver's license) to control steering wheel by using steering assistive devices in the driving simulator. The persons with partial loss of use of all four limbs have problems in operation of the motor vehicle because of functional loss to operate steering wheel. Therefore, if steering assistive devices for grasping the steering wheel are used to control the vehicle on the road in persons with disabilities, the disabled persons can improve mobility in their community life by driving a motor vehicle safely. Ten healthy subjects (with or w/o driver's license) and ten subjects with physical disabilities (with or w/o driver's license) were involved in this study to evaluate driving performance to operate steering wheel by using four types of steering assistive devices (Single-pin, V-grip, Palm-grip, Tri-pin) in driving simulator. STISim Drive 3 software was used to test the steering performance in four scenarios: straight road at low and high speed of vehicle (40 km/h and 80 km/h), curved road at low and high speed of vehicle (40 km/h and 80 km/h). This study used two-way ANOVA in order to compare the effects of two factors (type of steering assistive device and subject group) in the three dependent variables of driving performance (the lateral position of vehicle, standard deviation of lateral position representing the variation of the left and right movement of the vehicle and the number of line crossing). The mean values of the three dependent variables (lateral position, standard deviation of lateral position, the number of line crossing) of steering performance were statistically significantly smaller for the healthy or disabled groups with driver's license than the other groups without driver's license on the curved road at high speed of vehicle compared to low speed of vehicle.

Arthroscopic Findings of the Canine Stifle Joint (정상견 무릎의 관절경 검사소견)

  • 정순욱;정월순
    • Journal of Veterinary Clinics
    • /
    • v.16 no.2
    • /
    • pp.300-308
    • /
    • 1999
  • Arthroscopy is a valuable diagnostic and operative tool in equine and human orthopedics. The arthroscope is a difficult instrument to use and requires patience, practice, and persistence in order to obtain good results. This technique was found to be less traumatic than arthrotomy, invasiveness, rapid recovery and the feasibility of surgically correcting many arthropathies. The use of the arthroscope in the dog provides a new dimension in the study and diagnosis of joint derangements. The purpose of this report is to introduce the use of the arthroscope in the dog-more specifically, in the stifle of the dog. A diameter 2.7 mm fore-oblique viewing arthroscope, cold light source, video and video printer are used. With the fore-oblique viewing type it is possible to view directly as well as slightly to the side and the range of viewing can be increased by rotating the arthroscope around the object The scope is connected with a cold light source by means of a fiber-optic light guide. The stifle joint was flexed to 20~30$^{\circ}$. The joint were lavaged with lactated Ringer's solution during arthroscopic examination. Arthroscopy of the stifle was performed prior to arthrotomy in 1 dead dog and 4 healthy dogs, and other 3 dogs was performed only arthroscopic examination. In this study only the conventional approaches were used and in most cases it was possible to view all the intra-articular structures via the lateral infrapatellar approach. In the stifle joint, endoscopic observation was performed to find lateral femoral condyle, patella, medial femoral condyle, trochlear groove, tibia, fat, cranial cruciate ligament, caudal cruciate ligament lateral meniscus, tendon of long digital extensor muscle, medial meniscus, and medial collateral ligament Post-arthroscopic examination, the lameness had disappeared within 12~24 hours. Pain and swelling in the stifle joint had disappeared within 24~36 hours. Post-arthroscopic secondary infection was never encountered in the dogs. In conclusion, arthroscopic insertion technique in canine stifle joint using a diameter 2.7 mm 30$^{\circ}$ arthroscope was established and arthroscopical views of all anatomical structures in the normal stilfe joint were obtained through lateral infrapatellar portal.

  • PDF

Cyclic Lateral Loading Test for Cast-In-Place Concrete-Filled Hollow PC Columns Using Permanent Inner form (영구 내부거푸집을 이용한 현장타설 콘크리트 채움중공 PC기둥의 반복횡가력실험)

  • Lee, Ho-Jun;Park, Hong-Gun;Kim, Chang-Soo;Hwang, Hyeon-Jong
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.2
    • /
    • pp.129-139
    • /
    • 2016
  • Cast-in-place concrete-filled hollow PC (HPC) columns are used to reduce lifting load of heavy-weight PC columns and to improve the structural integrity of joints. In the present study, a new type of HPC column was proposed to improve the productivity and structural integrity of the concrete. To form the hollow PC columns, a permanent inner form was prefabricated using structural deck plates and penetrated lateral bars. Half-scale specimens of four HPC columns were tested under combined axial compression and lateral cyclic loading to evaluate the seismic resistance. In the design of test specimens, various parameters such as the spacing of lateral re-bars, the use of steel fiber, and the thickness of PC cover were considered. The test results showed that the proposed HPC columns generally exhibited satisfactory load-carrying capacity and deformation capacity without brittle failure of PC. If closely spaced hoops or fiber reinforcements are used for PC, the deformation capacity can be improved further by restraining PC spalling.

Comparative Study of Spiral Oblique Retinacular Ligament Reconstruction Techniques Using Either a Lateral Band or a Tendon Graft

  • Oh, Jae Yun;Kim, Jin Soo;Lee, Dong Chul;Yang, Jae Won;Ki, Sae Hwi;Jeon, Byung Joon;Roh, Si Young
    • Archives of Plastic Surgery
    • /
    • v.40 no.6
    • /
    • pp.773-778
    • /
    • 2013
  • Background In the management of mallet deformities, oblique retinacular ligament (ORL) reconstruction provides a mechanism for automatic distal interphalangeal (DIP) joint extension upon active proximal interphalangeal joint extension. The two variants of ORL reconstruction utilize either the lateral band or a free tendon graft. This study aims to compare these two surgical techniques and to assess any differences in functional outcome. As a secondary measure, the Mitek bone anchor and pull-in suture methods are compared. Methods A single-institutional retrospective review of ORL reconstruction was performed. The standard patient demographics, injury mechanism, type of ORL reconstruction, and pre/postoperative degree of extension lag were collected for the 27 cases identified. The cases were divided into lateral band (group A, n=15) and free tendon graft groups (group B, n=12). Group B was subdivided into the pull-in suture technique (B-I) and the Mitek bone anchor method (B-II). Results Overall, ORL reconstructions had improved the mean DIP extension lag by $10^{\circ}$ (P=0.027). Neither the reconstructive technique choice nor bone fixation method identified any statistically meaningful difference in functional outcome (P=0.51 and P=0.83, respectively). Soft-tissue injury was associated with $30.8^{\circ}$ of improvement in the extension lag. The most common complications were tendon adhesion and rupture. Conclusions The choice of the ORL reconstructive technique or the bone anchor method did not influence the primary functional outcome of extension lag in this study. Both lateral band and free tendon graft ORL reconstructions are valid treatment methods in the management of chronic mallet deformity.

EVALUATION OF APICAL SEAL ACCORDING TO TYPES OF SPREADER AND COMPATIBILITY OF ACCESSORY CONE USED IN LATERAL CONDENSATION METHOD WITHOUT SEALER (Spreader의 종류와 Accessory cone의 접합성에 따른 근단폐쇄성에 관한 실험적 연구)

  • Ahn, Young-Mi;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.2
    • /
    • pp.461-472
    • /
    • 1994
  • The purpose of this study was to evaluate the sealing ability according to types of spreader and compatibility of accessory cone used in lateral condensation method. 120 plastic blocks with canal preformed were instrumented with K-,H-files and Gates-Gllidden bur. Shaped plastic blocks were divided into six experimental groups according to spreader and accessory cone used in lateral condensation. Then they were obturated by lateral condensation method without -sealer. Six experimental groups were as follows: Group 1 : Filling with #30 spreader & #25 gutta-percha cone Group 2 : Filling with #30 spreader & Fine accessory cone Group 3 : Filling with #3 spreader & #25 gutta-percha cone Group 4 : Filling with #3 spreader & Fine accessory cone Group 5 : Filling with #20,#30 spreader & #25 gutta-percha cone Group 6 : Filling with #2, #3 spreader & Fine accessory cone All the blocks were stored in 100% humidor at room temperature for 2 days. Each block was placed in centrifuged for 20 minutes at 3,000 rpm. Apical leakage was mesured from the apical foramen to the most coronal level of- dye leakage in millimeter under a stereoscope. The data were analysed by ANOVA. The obtained results were as follows; 1. In groups using two spreaders(Group 5,6), the linear leakage was less than one spreader using groups(Group 1-4). 2. Tn groups using two spreaders(Group 5,6), there was no significant difference in linear leakage between standardized -spreader group and non standardized group (p>0.01). 3. When one spreader was used(Group 1-4), standardized-spreader groups showed less linear leakage than nonstandardized spreader groups(P<0.01). 4. In case of using same spreader(Groupl,2 & Group 3,4), there was no significant difference in linear leakage according to accessory cone type. 5. It needs to use one more spreaders to increase apical sealability.

  • PDF

The effect of working parameters on removal of casting gold alloy using a piezoelectric ultrasonic scaler with scaler tip in vitro (압전방식 초음파 치석제거기의 작업조건에 따른 치과주조용 합금의 삭제에 관한 연구)

  • Cha, Kuk-Bong;Kim, Won-Kyung;Lee, Young-Kyoo;Kim, Young-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.39 no.2
    • /
    • pp.139-148
    • /
    • 2009
  • Purpose: Ultrasonic scalers have been widely used for removing biofilm which is considered as major etiologic factor of periodontal disease. The purpose of this study was to evaluate the effect of working parameters of piezoeletric ultrasonic scaler with scaler tip (No. 1 tip) on casting gold alloy removal. Methods: Type III dental casting gold alloy (Firmilay$^{circledR}$, Jelenko Inc, CA, USA) was used as substitute for tooth substance. Piezoeletric ultrasonic scaler and No.1 scaler tip (P-Max$^{circledR}$, Satelec, France) were selected. The selected working parameters were mode (P mode, S mode), power setting (2, 4, 8) and lateral force (0.5 N, 1.0 N, 2.0 N). The effect of working parameters was evaluated in terms of ablation depth, ablation width and ablation area. Results: Mode influenced ablation depth and ablation area. Power also influenced ablation depth and ablation area. Especially, Power 2 and power 8 showed statistically significant difference. Lateral force had influence on ablation width, and 0.5 N resulted significant increase compared with 1.0 N and 2.0 N. Ablation depth was influenced by mode, power and lateral force and defect width was influenced by lateral force. Ablation area was influenced by mode and power. Conclusions: It can be concluded that the use of piezoelectric ultrasonic scaler with No. 1 scaler tip in S mode and high power may result in significant loss of tooth substance.

A COMPARISON OF SCANORA$\textregistered$ RADIOGRAPHY WITH WATERS' AND PANORAMIC VIEWS FOR THE DETECTION OF MUCOSAL THICKENING OF MAXILLARY SINUS (워터스, 파노라마 방사선사진과 Scanora$\textregistered$ 방사선사진의 상악동 점막비후 진단 결과의 비교)

  • Yoon Suk-Ja;Jung Hyun-Dae;Kang Byung-Chul
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.2
    • /
    • pp.389-398
    • /
    • 1995
  • The purpose of this study was to compare the diagnostic performance of Waters' and panoramic view; maxillary sinus posteroanterior and lateral scanography of Scanora/sup (R)/ for mucosal thickening of maxillary sinus as well as to identify the utility of Scanora/sup (R)/ for the detection of maxillary sinus disease. The assessment was done at 66 maxillary sinuses in 45 patients and the results were as follows ; 1. Estimation of presence or absence of mucosal thickening. The sensitivity, specificity, and positive and negative predictive value of maxillary sinus posteroanterior and lateral scanography were 0.865, 0.860, 0.921, and 0.805 respectively and slightly higher than those of Waters' and panoramic views, which were 0.832, 0.835, 0.903, and 0.728 respectively. However, paired t-test showed no significant differences in the diagnostic performance of the two pairs of imaging modalities. 2. Estimation of the types of mucosal thickening. The diagnostic accuracy for type I, II, III was 75.3% on Waters' and panoramic view; 77.9% on maxillary sinus posteroanterior and lateral scanography. It was higher on the latter ,but showed no significant differences from that on the former. 3. Reliability of interpretation. In itraobserver and interobserver agreement, both overall rates of agreement and kappa-value were slightly higher on maxillary sinus posteroanterior and lateral scanography than on Waters' and panoramic views. There was no significant differences between the two pairs of imaging modalities. These results suggested that scanogram is a useful diagnostic radiography as well as Waters' and panoramic views for detection of maxillary sinusitis.

  • PDF