• Title/Summary/Keyword: Lateral vibration

Search Result 491, Processing Time 0.023 seconds

Dynamic Analysis for 1 inch micro-drive (1인치 마이크로 드라이브의 동특성 해석)

  • 황창호;박경수;전정일;박영필;박노철
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.592-597
    • /
    • 2003
  • To solve a problem of micro drive due to small size and portability, it is necessary to understand and to investigate micro drive widely ,deeply. So, we performed modal analysis of suspension of micro drive, and load/unload experiment for Input current to VCM coil and disk speed. To determine the effect of ramp profile, curve fitting of lateral speed is performed with equation of speed. The results indicate that small load/unload speeds decrease the number of head/disk contacts, and during unloading process, low disk speed increase the number of head/disk contacts.

  • PDF

The Effect of Initial Combined Load on the Lateral Free Vibration on the Arch and P-M Interactive Curve (아치의 곡률면외 자유진동 해석과 P-M 상관도 작성)

  • 전교영;한금호;한상윤;강영종
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.10a
    • /
    • pp.452-461
    • /
    • 2003
  • The effect of initial combined load on the lateral free vibration of arches is investigated. For the analysis, P-M interaction own for the arches are obtained. The arches are circular arches which have constant cross-section and simply supported. Also, the arches are subjected both radial uniform distributed load which results in an axial compression on the cross-section and end moments that cause uniform bending action at the same time. All analysis are performed by finite element method based on Kang and Yoo's curved beam theory.

  • PDF

A Study on Dynamic Properties Estimation of On-Site Railroad Track (현장 궤도 동특성 추정에 관한 연구)

  • 이희현;남보현;박용진;이종득
    • Journal of the Korean Society for Railway
    • /
    • v.4 no.2
    • /
    • pp.39-46
    • /
    • 2001
  • In this paper, train running test and lateral resistant force test are conducted before and after sprinkling the ballast stabilizer in order to investigate the dynamic behaviors and parameters of the railroad track. The measured results are used to confirm the effect of the stabilizer and to validate the numerical results. From this paper, it is known that the stabilizer used in this study has excellent effect on increasing the vertical rigidity and the lateral resistance, and some correction factors should be considered on masses and rigidities of the track components in order to calculate the vibration magnitude reasonably due to running train.

  • PDF

Free axial vibration analysis of axially functionally graded thick nanorods using nonlocal Bishop's theory

  • Nazemnezhad, Reza;Kamali, Kamran
    • Steel and Composite Structures
    • /
    • v.28 no.6
    • /
    • pp.749-758
    • /
    • 2018
  • Free axial vibration of axially functionally graded (AFG) nanorods is studied by focusing on the inertia of lateral motions and shear stiffness effects. To this end, Bishop's theory considering the inertia of the lateral motions and shear stiffness effects and the nonlocal theory considering the small scale effect are used. The material properties are assumed to change continuously through the length of the AFG nanorod according to a power-law distribution. Then, nonlocal governing equation of motion and boundary conditions are derived by implementing the Hamilton's principle. The governing equation is solved using the harmonic differential quadrature method (HDQM), After that, the first five axial natural frequencies of the AFG nanorod with clamped-clamped end condition are obtained. In the next step, effects of various parameters like the length of the AFG nanorod, the diameter of the AFG nanorod, material properties, and the nonlocal parameter value on natural frequencies are investigated. Results of the present study can be useful in more accurate design of nano-electro-mechanical systems in which nanotubes are used.

Effectiveness of seismic repairing stages with CFRPs on the seismic performance of damaged RC frames

  • Duran, Burak;Tunaboyu, Onur;Kaplan, Onur;Avsar, Ozgur
    • Structural Engineering and Mechanics
    • /
    • v.67 no.3
    • /
    • pp.233-244
    • /
    • 2018
  • This study aims at evaluating the performance of repairing technique with CFRPs in recovering cyclic performance of damaged columns in flexure in terms of structural response parameters such as strength, dissipated energy, stiffness degradation. A 2/3 scaled substandard reinforced concrete frame was constructed to represent the substandard RC buildings especially in developing countries. These substandard buildings have several structural deficiencies such as strong beam-weak column phenomenon, improper reinforcement detailing and poor material properties. Flexural plastic hinges occurred at the columns ends after testing the substandard specimen under both constant axial load and reversed cyclic lateral loading. Afterwards, the damaged columns were externally wrapped with CFRP sheets both in transverse and longitudinal directions and then retested under the same loading protocol. In addition, ambient vibration measurements were taken from the undamaged, damaged and the repaired specimens at each structural repair steps to identify the effectiveness of each repairing step by monitoring the change in the natural frequencies of the tested specimen. The ambient vibration test results showed that the applied repairing technique with external CFRP wrapping was proved to recover stiffness of the pre-damaged specimen. Moreover, the lateral load capacity of the pre-damaged substandard RC frame was restored with externally bonded CFRP sheets.

Tuned mass dampers for torsionally coupled systems

  • Pansare, A.P.;Jangid, R.S.
    • Wind and Structures
    • /
    • v.6 no.1
    • /
    • pp.23-40
    • /
    • 2003
  • The steady state response of a torsionally coupled system with tuned mass dampers (TMDs) to external wind-induced harmonic excitation is presented. The torsionally coupled system is considered as one-way eccentric system. The eccentricity considered in the system is accidental eccentricity only. The performance of single tuned mass damper (TMD) optimally designed without considering the torsion is investigated for the torsionally coupled system and found that the effectiveness of a single TMD is significantly reduced due to torsion in the system. However, the design of TMD system without considering the torsion is only justified for torsionally stiff systems. Further, the optimum parameters of a single TMD considering the accidental eccentricity are obtained using numerical searching technique for different values of uncoupled torsional to lateral frequency ratio and aspect ratio of the system. The optimally designed single TMD system is found to be less effective for torsionally coupled system in comparison to uncoupled system. This is due to the fact that a torsionally coupled system has two natural frequencies of vibration, as a result, at least two TMDs are required which can control both lateral and torsional response of the system. The optimum damper parameters of different alternate arrangements such as (i) two identical TMDs placed at opposite corners, (ii) two independent TMDs and (iii) four TMDs are evaluated for minimum response of the system. The comparative performance of the above TMDs arrangements is also studied for both torsionally coupled and uncoupled systems. It is found that four TMDs arrangement is quite effective solution for vibration control of torsionally coupled system.

Experiences of the Specified Symptoms from the Selected Work-Related Musculoskeletal Syndrome and Posture and Action of the Dental Hygienists When Work-Related Musculoskeletal Diseases of Dental Hygienists Patient Care Procedure

  • Lee, Ka Yeon;Chun, Jong Ae
    • International Journal of Clinical Preventive Dentistry
    • /
    • v.14 no.4
    • /
    • pp.235-240
    • /
    • 2018
  • Objective: The purpose of this study is to examine about dental hygienists' myofascial pain syndrome, lower back pain, carpal tunnel syndrome (CTS), medial and lateral epicondylitis, hand-arm vibration syndrom and work-related musculoskeletal syndrome (WMSD) experience and hygienists' posture, motion. Methods: The self-administered questionnaire was surveyed from June 1 to September 30 of 2018 targeting 280 dental hygienists in Gyeongnam province and 266 dental hygienists' answers were analyzed. Results: The average daily working hours of a dental hygienist was more than eight hours 59.0%, with an average of 33 patients per day. The average number of patients who receive treatment for more than 30 minutes is 15. The angle of motion of the subjective evaluation was above 60%. Medical position and form of movement were more than 50% above the standard level. Symptoms of posture and motion that cause WMSD were hand-arm vibration syndrome 68.1%, myofascial pain syndrome 58.6%, lower back pain 51.1%, CTS 50.4% in order. Experience WMSD related symptoms which dental hygienists experience were myofascial pain syndrome 92.9%, CTS 57.9%, lower back pain 56.4%, medial and lateral epicondylitis 37.2%, hand-arm vibration syndrome 24.4%. Conclusion: The above results showed the posture and motion of dental hygienists and were found that the experience rate which dental hygienists experience WMSD of myofascial pain syndrome, Lower back pain, and CTS was significantly more than 56%.

Conditions to avoid synchronization effects in lateral vibration of footbridges

  • Andrade, Alexandre R.;Pimentel, Roberto L.;Silva, Simplicio A. da;Souto, Cicero da R.
    • Structural Monitoring and Maintenance
    • /
    • v.9 no.2
    • /
    • pp.201-220
    • /
    • 2022
  • Lateral vibrations of footbridges may induce synchronization between pedestrians and structure itself, resulting in amplification of such vibrations, a phenomenon identified by lock-in. However, investigations about accelerations and frequencies of the structural movement that are related to the occurrence of synchronization are still incipient. The aim of this paper is to investigate conditions that could lead to avoidance of synchronization among pedestrians themselves and footbridge, expressed in terms of peak acceleration. The focus is on the low acceleration range, employed in some guidelines as a criterion to avoid synchronization. An experimental campaign was carried out, employing a prototype footbridge that was set into oscillatory motion through a pneumatic exciter controlled by a fuzzy system, with controlled frequency and amplitude. Test subjects were then asked to cross the oscillating structure, and accelerations were simultaneously recorded at the structure and at the subject's waist. Pattern and phase differences between these signals were analysed. The results showed that test subjects tended to keep their walking patterns without synchronization induced by the vibration of the structure, for structural peak acceleration values up to 0.18 m/s2, when frequencies of oscillation were around 0.8 to 0.9 Hz. On the other hand, for frequencies of oscillation below 0.7 Hz, structural peak accelerations up to 0.30 m/s2 did not induce synchronization.

A Fundamental Study on Vibration Characteristics of Container Car for Sensitive Cargo Transportation according to ASTM D-4169 (ASTM 규격에 따른 민감화물 수송용 컨테이너 화차의 진동 특성에 관한 기초 연구)

  • Ki, Ho-Cheol;Lee, Seung-Yil;Kim, Chul-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.53-59
    • /
    • 2019
  • To reduce the vibrations and shocks during the cargo transportation of high value-added goods, the vibration history was measured on the truck transportation section (Asan-Uiwang) and the freight train transportation section (Uiwang-Pusan). The internal vibrations of the container were obtained by attaching acceleration sensors in three axis directions (longitudinal, lateral. and vertical directions) on the front and rear bogies. The rail vibration profile (0.29Grms) proposed in ASTM D-4169 was approximately 50% higher than the truck vibration profile (0.54Grms). The overall vibration was 16% and 33 % lower in the longitudinal and transverse directions, respectively, compared to the ASTM truck transport vibration profile. On the other hand, the vertical vibration measurement history partially exceeded the ASTM truck transport vibration profile over the range, 4 - 15Hz, and over 60Hz. The vibration measurement history of the cargo train was similar to that of the road. The longitudinal and lateral vibration history was lower than the ASTM D-4169 rail vibration profile, while the vertical history was over 30Hz.

Veering Phenomena and Dynamic Characteristics in Lateral Micro-Gyroscope (수평형 마이크로 자이로스코프의 비어링 현상 및 동특성)

  • 정호섭;박규연
    • Journal of KSNVE
    • /
    • v.11 no.1
    • /
    • pp.132-140
    • /
    • 2001
  • The vibratory gyroscope can effectively measure the angular velocity as the oscillating and position-sensing mode are exactly tuned. The veering Phenomenon impedes the exact tuning, which is caused by the mode coupling of two modes. In this paper, the gyroscope's structure with two frames is introduced to minimize the veering phenomenon that destabilizes the tuning process of oscillating and position-sensing mode. Experimental results show that the Proposed structure can achieve the mode intersection without veering phenomenon.

  • PDF