• 제목/요약/키워드: Lateral resolution.

검색결과 168건 처리시간 0.027초

TEM Stud of GaN Thick Film Crystals Grown by HVPE

  • 송세안;이성국
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1999년도 제17회 학술발표회 논문개요집
    • /
    • pp.121-121
    • /
    • 1999
  • Gallium nitride (GaN) semiconductor is intensively under investigation for commercialization of short wavelength light emitting devices and laser diodes. One of serious obstacles to overcome is to reduce the defect density in GaN film grown by various techniques such as MOCVD, HVPE, etc. Many research groups including SAIT are trying to improve the defect density to 106-107/cm2 from the level of 108-1010/cm2. We have investigated epitaxial growth behaviour of GaN thin and thick films under hidride vapour phase epitaxy (HVPE) condition. In this report, we present the microstructural and crystallographical characteristics of the GaN films grown on sapphire (0001) substrate which were studied by both conventional and high-resolution transmission electron microscopy (TEM). Also we present some microscopic analysis results obtained from GaN films grown by ELO(dpitzsial lateral overgrowth)-HVPE and from GaN quantum well structures grown by MOCVD. Another serious problem in growing GaN thick film by HVPE is internal micro-cracks. We also comment the origin of the micro-crack.

  • PDF

Orbital Dirofilariasis in Iran: A Case Report

  • Tavakolizadeh, Sepideh;Mobedi, Iraj
    • Parasites, Hosts and Diseases
    • /
    • 제47권4호
    • /
    • pp.397-399
    • /
    • 2009
  • Dirofilariasis is a common parasitic disease in both domestic and wild animals around the world, with canines as the principal reservoir host and mosquitoes as the vector. Human ophthalmic dirofilariasis is an uncommon condition, but there have been reports from many parts of the world, including Africa, Australia, the Americas, Europe, and Asia. Ophthalmic involvement with Dirofilaria may present itself as periorbital, subconjunctival, orbital, or intraocular infections. In this report, we present a case of orbital dirofilariasis with lateral rectus muscle involvement. To our knowledge, this is the first orbital dirofilariasis case reported in Iran. Although debulking of the tumor usually leads to resolution, our patient showed an episode of recurrence after biopsy. Complete recovery was achieved after a spontaneous discharge, without the need for systemic medication.

Emission-type THz NSOM 에 대한 수치해석 (Numerical Analysis of Emission-type THz NSOM)

  • 이경인;윤석호;박홍규;김정회;한해욱
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.183-184
    • /
    • 2006
  • The simulation on the mechanism of terahertz NSOM(near-field scanning optical microscopy) have been investigated. Based on experimental results, we have demonstrated the antenna effects on the coupling between a metal tip and substrate for an emission-type terahertz NSOM. It has been found that the lateral resolution can be estimated by a simplified model using an infinitesimal dipole in the substrate.

  • PDF

형상의 이차미분을 이용한 비구면 형상측정기술 개발 (Development of Aspheric Surface Profilometry using 2nd Derivative)

  • 김병창
    • 한국기계가공학회지
    • /
    • 제10권2호
    • /
    • pp.104-109
    • /
    • 2011
  • I present a method of aspheric surface profile measurement using 2nd derivative of local area profile. This method is based on the principle of curvature sensor which measures the local 2nd derivative under test along a line. The profile is then reconstructed from the data on the each point. Unlike subaperture-stiching method and slope detection method, 2nd derivative method has strong points from a geometric point of view in measuring the aspheric surface profile. The second derivative terms of surface profile is an intrinsic property of the test piece, which is independent of its position and tip-tilt motion. The curvature is measured at every local area with high accuracy and high lateral resolution by using White-light scanning interferometry.

유체역학 현상을 이용한 현미경 검사법 개발 (A Scanning Flow Impedance Micrscope)

  • 김태영;김동권;김성진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2670-2675
    • /
    • 2008
  • We introduce a new type of surface microscope using hydrodynamic phenomena. The fluid flow through the opening of the pipette probe is blocked at short distances between the probe and the surface, thus increasing the pressure loss. Therefore, a scanning flow impedance microscope (SFIM) can image the surface topology by scanning the probe with measuring the pressure loss. The SFIM can display the topology regardless of surface hardness, surface electrical conductivity, and surrounding fluid. The present letter contains the first experimental results on surface topography obtained with this novel microscope. The preliminary results in air demonstrate the lateral resolution of the SFIM is very close to the inner diameter of the probe.

  • PDF

Salvage Approaches for Maintaining the Eye Globe in a Glaucomatous Patient with Severe Unilateral Exophthalmos

  • Kim, Eunjik;Yun, Sungho;Kwon, Young-Sam
    • 한국임상수의학회지
    • /
    • 제34권2호
    • /
    • pp.123-125
    • /
    • 2017
  • An eight-year-old Shih-Tzu dog was referred to Kyungpook National University Veterinary Medical Teaching Hospital because of severe glaucoma and exophthalmos. The symptoms included severe buphthalmos, conjunctival hyperemia, focal dried cornea and discomfort in the affected eye. Although enucleation was considered as a potential intervention measure in light of the severity of symptoms, it was possible to save the globe and relieve symptoms through evisceration, intraocular prosthesis implantation, and lateral canthoplasty. Our experience with this case suggests that symptomatic salvage therapy, rather than enucleation, is an appropriate approach for resolution of exopthalmos and other complications associated with glaucoma surgery.

Development of Image-space Telecentric Lens for Intra-Oral 3D Scanner

  • Kim, Tae Young;Shin, Min-Ho;Chang, Ryungkee;Kim, Young-Joo
    • Journal of the Optical Society of Korea
    • /
    • 제19권3호
    • /
    • pp.303-310
    • /
    • 2015
  • An image-space telecentric lens for an intra-oral 3D scanner was designed and fabricated for dental application. Since a telecentric function can provide the same results regardless of image plane position, it helps to realize a more accurate image for an intra-oral scanner. The performance of the designed lens meets the required properties for HD resolution. In particular, lateral color is corrected within 1 pixel. This system achieves depth of focus of more than 3 mm. For user convenience, the developed system consists of a prism part and an imaging part. Both parts are optimized to reduce the front size and weight of the system. In order to make the parallax sights, parallax angle was determined to be 8 degrees between two optical systems.

Detection System for Sub-micrometer Defects of a Photo-mask Using On-axis Interference between Reflected and Scattered Lights

  • Lee, Sangon;Jo, Jae Heung;Kim, Jong Soo;Moon, Il Kweon
    • Journal of the Optical Society of Korea
    • /
    • 제17권1호
    • /
    • pp.73-80
    • /
    • 2013
  • In the process of lithography using ultra violet light sources for semiconductor devices, most of defects are made by sub-micrometer pollutants generated at photochemical reactions. We proposed and developed a novel vibration-insensitive on-axis interferometer with a sub-micrometer lateral resolution by using the interference between two beams: one scattered from defects and the other reflected from a reference area without defects. The proposed system was successfully demonstrated to detect a small Al defect of 0.5 ${\mu}m$ diameter within the inspection time of less than 30 minutes over the area of the photo-mask which is 6 inch by 6 inch square.

Development of confocal scanning microscopy using acousto-optica1 deflector

  • J.W. Seo;D.K. Kang;H.G. Yun;Kim, K.H.;D.G. Gweon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.161.6-161
    • /
    • 2001
  • Confocal scanning microscopy (CSM) has an important role as the three-dimensional profiler. An image distribution can be reconstructed by a correlation analysis of spots with the bandwidth of radio frequency. But it is a serious problem for the high performance to align the optical components. Especially, the parasitic motion of focus on the detector gives rise to the fatal distortion of an image profile named the extinction effect while using acousto-optical(AO) deflector. An image profile can be regenerated in CSM with many advantages of non-contact, high speed and high resolution comparatively. In addition to the axial response of the primary focus, the lateral movement of it gives a necessity of the unitary lens to the scanning system. While using the beam deflector, the pupil of beam may be fixed at the nominal position. Furthermore, the use of a deflector may result in ...

  • PDF

울릉 난수성 Eddy와 해저지형과의 상호작용에 관한 수치모델 연구 (A Numerical Study on the Interaction of Ulleung Warm Eddy with Topography and Lateral Boundary)

  • 임근식;김구
    • 한국해양학회지
    • /
    • 제30권6호
    • /
    • pp.565-583
    • /
    • 1995
  • 난수성 eddy의 운동에 있어서 경계면 마찰과 해저지형의 중요성을 연구하기 위하여 비선형 QG-모델이 사용되었다. 수직구조를 나타내는 유선함수의 경험적 직교함수는 순압과 제 1 경압 역학 함수를 표현한다. 이 모델은 10 km ${\times}$ 10 km의 격자간격을 지닌 1000 km ${\times}$ 1000 km으로 구성되어 있고 360일동안 시험하였다. 대한해협을 통한 유입량은 쓰가루해협을 통하여 빠져 나간다. 울릉분지내(평평한 해저지형)에서는 QG방정식의 비선형 이류항과 ${\beta}$-효과사이에 균형이 난수성 eddy를 북쪽으로 이동하게 한다. 대륙사면위에서의 난수성 eddy는 비선형항이 중요하게 작용하지만, 평평한 지형에서는 보조적인 역활을 한다. 해저지형이 변화하는 해역에서 난수성 eddy의 비선형항은 시간의 함수이다. 강한 eddy는 북쪽으로 이동한다. Eddy의 세기가 약해지면, 비선형항과 지형적인 베타효과항이 균형을 이루게 된다. Eddy의 분산과 함께 비선형성이 감소하므로서, 지형적 Rossby파 개념에 의하여 난수성 eddy는 대륙사면을 따라서 남하한다. 수치실험은 난수성 eddy의 운동에 미치는 경계면 마찰의 중요성을 확인하였다. 난수성 eddy의 북쪽 침투거리는 경계면 마찰계수의 감소로 증가하게 된다 아울러 Reynolds number의 감소로 북쪽이동을 방지할 수 있다. 또한 이 난수성 eddy운동과정에 있어서 해저지형이 중요한 역할을 하는 것이 제시되었다.

  • PDF