• 제목/요약/키워드: Lateral resolution.

검색결과 168건 처리시간 0.04초

초음파 영상장치에서 해상도 향상에 관한 연구 (A Study on the improvement a Resolution of the Ultrasound Imaging System)

  • 이후정;김영길;이행세
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(II)
    • /
    • pp.1235-1238
    • /
    • 1987
  • In this paper, a new focusing method, to be called the sampled delay focusing (SDF), is proposed. This method improves the lateral resolution in ultrasound imaging system. In SDF, the analog delay lines are no longer necessary because sampling sum process can replace the conventional delay sum process. Also, this method offers continuous dynamic focusing on the resolution pixel basis if the maximum delay time is less than the sampling interval. Second order sampling is adopted in order to extend the sampling interval.

  • PDF

초음파 B스캔너의 개발(I) -시스템 및 아나로그부분- (Development of Ultrasound B-scanner(I)-System and Analog Part-)

  • 김진하;신동희
    • 대한의용생체공학회:의공학회지
    • /
    • 제5권1호
    • /
    • pp.77-84
    • /
    • 1984
  • A prototype of a linear real-time ultrasound B-scanner has been developed which has an axial resolution of 1-2mm and lateral resolution of 2-3mm. In the actual hardware and software implementations of the B-scanner, the following features were emphasized; (1) a dynamic focusing to improve resolution; (2) signal processing to obtain low noise image; (3) various functions for the user's convenience' (4) simplification of the system by an extensive use of recently developed LSI's; (5) development of a prototype at the level of a commercial product. This paper reports the experimental results of the overall system and the design approach of the analog part. The work on the digital part of the B-scanner is reported in part (II) seperately.

  • PDF

변형된 Wiener 필터를 이용한 초음파 B스캔영상의 해상력 향상 (Resolution Enhancement of Ultrasonic B-scan Images by Modified Wiener Filter)

  • 정준영;진영민
    • 대한의용생체공학회:의공학회지
    • /
    • 제11권1호
    • /
    • pp.113-120
    • /
    • 1990
  • In this paper, the deconvolution method utilizing a modified Wiener filter is applied for the enhancement of lateral resolution of ultrasonic B-scan Images. For this purpose, a phantom composed of wires which are 0.6mm of diameter and apart in the range between 3 to 9mm is constructed. The modified Wiener filter with optimal parameter is applied to the phantom for the analysis of ultrasonic image. The results obtained are as follows'When all parameters of the modified Wiener filter are optimal, the resolution of B-scan images is enhanced by 50 percent : Othenrise, the images are blurred, spilt at peak points, or noises are strengthened severely. When the point-spread function representing the characteristic function of the system is determined, the selection ranges of op- timum parameters may be narrowed. It is expected that the proposed method may be able to apply to clinic situations for more accurate image analysis by means of reducing the loss of important information.

  • PDF

High Resolution Photonic Force Microscope Using Resonance Energy Transfer

  • Heo, Seung-Jin;Kim, Ki-Pom;Cho, Yong-Hoon
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.288-288
    • /
    • 2010
  • Photonic Force Microscope (PFM) is a scanning force microscope using an optical trap with several piconewton. In PFM, we can have topological information from the bead position trapped in optical trap. Typically the resolutions of lateral and vertical position are 40 nm and 50 nm respectively. To improve the vertical resolution below 10 nm, we use resonance energy transfer which has 5nm resolution in distance. Here we show preliminary results, including performances of scanning bead and fluorescence imaging system.

  • PDF

Simulation of Regional Climate over East Asia using Dynamical Downscaling Method

  • Oh, Jai-Ho;Kim, Tae-Kook;Min, Young-Mi
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2002년도 학술발표회 논문집(II)
    • /
    • pp.1187-1194
    • /
    • 2002
  • In this study, we have simulated regional climate over East Asia using dynamical downscaling For dynamic downscaling experiments for regional climate simulation, MM5method. with 27 km horizontal resolution and 18 layers of sigma-coordinate in vertical is nested within global-scale NCEP reanalysis data with 2.5。${\times}$2.5。 resolution in longitude and latitude. In regional simulation, January and July, 1979 monthly mean features have been obtained by both continuous integration and daily restart integration driven by updating the lateral boundary forcing at 6-hr intervals from the NCEP reanalysis data using a nudging scheme with the updating design of initial and boundary conditions in both continuous and restart integrations. In result, we may successfully generated regional detail features which might be forced by topography, lake, coastlines and land use distribution from a regional climate. There is no significant difference in monthly mean features either integrate continuously or integrate with daily restart. For climatologically long integration, the initial condition may not be significantly important. Accordingly, MM5 can be integrated for a long period without restart frequently, if a proper lateral boundary forcing is given.

  • PDF

Möbius Syndrome Demonstrated by the High-Resolution MR Imaging: a Case Report and Review of Literature

  • Hwang, Minhee;Baek, Hye Jin;Ryu, Kyeong Hwa;Choi, Bo Hwa;Ha, Ji Young;Do, Hyun Jung
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권2호
    • /
    • pp.167-171
    • /
    • 2019
  • $M\ddot{o}bius$ syndrome is a rare congenital condition, characterized by abducens and facial nerve palsy, resulting in limitation of lateral gaze movement and facial diplegia. However, to our knowledge, there have been few studies on evaluation of cranial nerves, on MR imaging in $M\ddot{o}bius$ syndrome. Herein, we describe a rare case of $M\ddot{o}bius$ syndrome representing limitation of lateral gaze, and weakness of facial expression, since the neonatal period. In this case, high-resolution MR imaging played a key role in diagnosing $M\ddot{o}bius$ syndrome, by direct visualization of corresponding cranial nerves abnormalities.

수리동역학적 모의를 위한 적정 격자해상도 산정방법 (Evaluation of Optimal Grid Resolution for Hydrodynamic Proper Simulation)

  • 안정민;박인혁;류시완;허영택
    • 대한공간정보학회지
    • /
    • 제20권1호
    • /
    • pp.109-116
    • /
    • 2012
  • 본 연구에서는 CCHE2D와 EFDC모형을 이용한 모의를 통하여 격자의 횡단해상도에 따른 물리적 지형의 재현성과 모의결과에 대한 영향을 검토하고자 하였다. 낙동강 금호강 유입구간을 대상으로 2006년 강우사상에 대한 부정류모의를 통하여 면적고도곡선과 대상구간내 수위관측소 지점에서의 실측치와 모의치간의 비교를 통하여 구성격자망의 적정성 및 모의결과에 대한 영향을 각각 검토하였다. 일반적으로 격자 해상도의 증가는 계산시간의 증가를 야기하므로 수행 내용과 목적, 계산의 효율성 측면에서 적절한 격자해상도의 선택이 필요하다. 정밀한 모의를 위해서는 고해상도 격자를 이용한 모의를 수행해야 하나, 빠른 의사결정이 요구되는 홍수기와 같이 모형수행의 효율성을 고려해야 하는 경우에 적용 가능한 물리적 지형의 재현성과 결과에 대한 신뢰성을 보장할 수 있는 적정 격자 해상도가 존재함을 확인할 수 있었다.

초음파 영상에서 변형된 직교 골레이 코드를 이용한 동시 다중 송신 집속 기법 (Multiple Transmit Focusing Method With Modified Orthogonal Golay Codes for Ultrasound Imaging)

  • 김배형;송태경
    • 대한의용생체공학회:의공학회지
    • /
    • 제24권3호
    • /
    • pp.217-231
    • /
    • 2003
  • 상보적인 특성을 갖는 골레이 수열을 이용하여 코드화된 신호를 송신하는 것은 SNR과 침투도를 향상시킬 수 있는 효과적인 방법이다. 그러나 각 주사선을 형성하기 위해 두 개의 상보적인 이진 코드를 연속하여 두 번 송신하기 때문에 프레임 율이 반으로 감소하게 된다 특히 이 방법은 측방향 해상도를 향상시키기 위해 다중 집속 기법(multi-zone focusing method)을 적용하면 송신 집속점의 개수에 따라 송신 횟수가 늘어나므로 프레임 율(frame rate)이 크게 저하된다. 본 논문에서는 이러한 문제를 해결하기 위해 변형된 직교 골레이 코드를 이용한 동시 다중 송신 집속 기법을 제안하였다 제안한 방법은 프레임 율의 저하 없이도 두 쌍의 직교 골레이 코드를 사용하여 서로 다른 위치에 동시에 송신 집속할 수 있다. 그리고 수신시에 정합 과정을 통해 분리, 압축한 다음 일반적인 다중 집속 기법과 같이 집속된 빔들을 결합함으로써 기존의 골레이 코드를 사용하는 송신 고정 집속 기법과 같은 프레임 율을 유지하면서도 측방향 해상도를 개선할 수 있다. 실제 초음파 영상을 위해 송신 신호로 사용되는 골레이 코드는 전송 전력 효율(Transmit Power Efficiency)을 높일 수 있도록 변형되었다. 컴퓨터 모사 실험과 실제 실험 결과는 제안한 방법이 기존의 방법에 비해 매우 향상된 측방향 해상도와 침투도를 갖는 초음파 영상을 제공한다는 것을 보여준다.