• 제목/요약/키워드: Lateral plate fixation

검색결과 42건 처리시간 0.028초

경추 전방 잠금식 금속판이 장기적으로 경추에 미치는 영향 (Long-term Effects on the Cervical Spine after Anterior Locking Plate Fixation)

  • 김근수
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권4호
    • /
    • pp.493-500
    • /
    • 2001
  • Objective : Anterior cervical locking plates are the devices for achieving anterior cervical spinal fusion. This study was conducted to evaluate the locking plate system regarding its long-term advantages and disadvantages in the view of interbody fusion rate, hardware-related failures, vertebral change close to the fusion segment and postoperative complications. Method : Eight-six patients, operated from Jan., 1996 to Jun. 1998, were followed-up for more than two years. All of the cases were fused with iliac bone graft and ORION locking plate(Sofamor Danek USA, Inc., Memphis, TN) fixation. The patients were discharged or transferred to rehabilitation department 2-7 days after operation. A comprehensive evaluation of the interbody fusion state, instrument failure, vertebral change and postoperative complications were made by direct interview and cervical flexion-extension lateral plain films. Results : There were 55 male and 31 female with a mean age of 45 years(18-75 years). The mean follow-up period was 29 months(24-43 months). Various disorders that were operated were 40 cervical discs, 6 cervical stenosis including OPLL, 2 infections, and 38 traumas. Fusion level was single in 59 cases, two levels of each disc space in 15 cases, and two levels after one corpectomy in 12 cases. There was no instrument failure. Pseudoarthrosis was observed in two cases(2%) without radiological instability. The other patients(98%) showed complete cervical fusion with stable instrument. Mild settling of interbody graft with upward migration of screws was found in 12 cases(14%). Anterior bony growth at the upper segment was found in 5 cases(6%). Postoperative foreign body sensation or dysphagia was observed in 12 cases(4%), and disappeared within one month in 7 cases and within six months in 4 cases. One patient complained for more than six months and required reoperation to remove paraesophageal granulation tissue. Conclusion : The results show that Orion cervical locking plate has some disadvantages of upward migration of screws, anterior bony growth at the upper segment, or possibility of esophageal compression even though it has advantages of high interbody fusion rate or low instrument failure. Author believe that anterior cervical locking plate in the future should be thinner, and should have short end from the screw hole, and movable screw with adequate stability.

  • PDF

종골 관절내 골절의 수술적 치료 후 임상 결과 -전산화 단층 촬영에 따른 분류 및 관혈적 정복 및 내고정 치료- (Result of Surgical Treatment of Intra-Articular Fractures of the Calcaneus - Based on CT Classification and Open Reduction and Internal Fixation -)

  • 김의순;서현모;이규민;최훈휘;문명상;이만희;최원태
    • 대한족부족관절학회지
    • /
    • 제7권2호
    • /
    • pp.238-249
    • /
    • 2003
  • Purpose: To report the clinical result of the intraarticular calcaneus fracture after open reduction and internal fixation with plate by lateral approach. Materials and Methods: Thirty-six calcaneal fractures of 33 patients(29 men and 4 women) were treated by open reduction and internal fixation using an lateral approach from March, 1997 to May, 2002 and were followed more than one year. The autogenous iliac bone graft was done in 2 cases but the others didn't. Radiographically B?hler angle and Gissane angle on simple lateral radiograph were measured and in the 15 cases, the step-off(gap) of posterior facet joint on post-operative CT images were followed. The Salama method was used for evaluation of clinical results. Results: According to Sanders classification, 19 cases of the 36 cases were classified as type II. Type III fracture were found in 12 cases and type IV in 5 cases. The following results were obtained: twenty-two cases(61.1%) out of 36 cases were estimated as good or excellent. The good results or more were obtained in 15 cases(78.9%) in type II and 7 cases(58.3%) in type ill, but no case in type IV. B?hler angles were improved from preoperative average 1.6?to postoperative average 23.4?, Gissane angle was improved from preoperative 107.2?to postoperative 122.8?, respectively. Among 36 cases, Computed tomography was carried out in 15 cases. The postoperative step-off (gap) of posterior facet joint on computed tomography was filled with cancellous bone. Satifactory results was obtained in 7 cases with 2mm gap or less and in 6 cases of 2-5mm. There were no satifactory results in 2 cases with 5mm gap or more. Conclusion: Open reduction and internal fixation for intra-articular fracture of calcaneus was thought to be a good treatment modality. It is thought that the lateral approach is one of the good one for surgical treatment, and that accurate reduction of the posterior facet, acceptable recovery of B?hler angle are more important to obtain best results.

  • PDF

관혈적 정복술 및 내고정술 후 군인에게 발생한 경비골 원위부 골결합증(1예 보고) (Distal Tibiofibular Synostosis after Open Reduction and Internal Fixation in a Military Soldier (A Case Report))

  • 이준영;남기영;송경철
    • 대한족부족관절학회지
    • /
    • 제14권1호
    • /
    • pp.105-107
    • /
    • 2010
  • The scanty literature on distal tibiofibular synostosis includes descriptions of relatively few specific complaints. Here we report a case of a 24-year-old young soldier who sustained a left ankle lateral malleolar fracture about 6 months ago and was initially treated by the open reduction and internal fixation with plate & screw. But 6 months later, he suffered from an vague ankle pain, each time the symptoms occurred right after an active ambulation, ankle dorsiflexion, especially when he had exercised aggressively. The radiographs revealed that there was a mature distal tibiofibular synostosis. We treated the patient with surgical excision of synostosis. Post-operative condition was satisfied to all concern and the result was found to be excellent during one-year follow-up.

Cephalometric evaluation of skeletal stability and pharyngeal airway changes after mandibular setback surgery: Bioabsorbable versus titanium plate and screw fixation

  • Phu Hnin Thet;Boosana Kaboosaya
    • Imaging Science in Dentistry
    • /
    • 제54권2호
    • /
    • pp.181-190
    • /
    • 2024
  • Purpose: This study compared sequential changes in skeletal stability and the pharyngeal airway following mandibular setback surgery involving fixation with either a titanium or a bioabsorbable plate and screws. Materials and Methods: Twenty-eight patients with mandibular prognathism undergoing bilateral sagittal split osteotomy by titanium or bioabsorbable fixation were randomly selected in this study. Lateral cephalometric analysis was conducted preoperatively and at 1 week, 3-6 months, and 1 year postoperatively. Mandibular stability was assessed by examining horizontal (BX), vertical (BY), and angular measurements including the sella-nasion to point B angle and the mandibular plane angle (MPA). Pharyngeal airway changes were evaluated by analyzing the nasopharynx, uvula-pharynx, tongue-pharynx, and epiglottis-pharynx (EOP) distances. Mandibular and pharyngeal airway changes were examined sequentially. To evaluate postoperative changes within groups, the Wilcoxon signed-rank test was employed, while the Mann-Whitney U test was used for between-group comparisons. Immediate postoperative changes in the airway were correlated to surgical movements using the Spearman rank test. Results: Significant changes in the MPA were observed in both the titanium and bioabsorbable groups at 3-6 months post-surgery, with significance persisting in the bioabsorbable group at 1 year postoperatively (2.29°±2.28°; P<0.05). The bioabsorbable group also exhibited significant EOP changes (-1.21±1.54 mm; P<0.05) at 3-6 months, which gradually returned to non-significant levels by 1 year postoperatively. Conclusion: Osteofixation using bioabsorbable plates and screws is comparable to that achieved with titanium in long-term skeletal stability and maintaining pharyngeal airway dimensions. However, a tendency for relapse exists, especially regarding the MPA.

Delayed formation of sterile abscess after zygomaticomaxillary complex fracture treatment with bioabsorbable plates

  • Doh, GyeongHyeon;Bahk, Sujin;Hong, Ki Yong;Lim, SooA;Han, Kang Min;Eo, SuRak
    • 대한두개안면성형외과학회지
    • /
    • 제19권2호
    • /
    • pp.143-147
    • /
    • 2018
  • We present a patient who showed a sterile abscess after facial bone fixation with bioabsorbable plates and screws. He had zygomaticomaxillary complex and periorbital fracture due to falling down. The displaced bones were treated by open reduction and internal fixation successfully using bioabsorbable plate system. However, at postoperative 11 months, abrupt painless swelling was noted on the previous operation sites, left lateral eyebrow and lower eyelid. By surgical exploration, pus-like discharge and degraded materials were observed and debrided. The pathologic analysis revealed foreign body reaction with sterile abscess. This complication followed by bioabsorbable device implantation on maxillofacial bone surgery has been rarely reported in which we call attention to the maxillofacial plastic surgeons.

주사형 황산 칼슘($MIIG^{TM}$)을 이용한 전위성 종골 관절내 골절의 수술적 치료 (The Operative Treatment of Displaced Intra-articular Calcaneal Fracture with Injectable Calcium Sulfate ($MIIG^{TM}$))

  • 안성준;김부환;송무호;유성호;서상혁
    • 대한족부족관절학회지
    • /
    • 제11권2호
    • /
    • pp.221-225
    • /
    • 2007
  • Purpose: To evaluate the clinical results of operative treatment of the intra-articular calcaneal fracture with injectable calcium sulfate ($MIIG^{TM}$). Materials and Methods: Between March 2004 and October 2006, a total 19 intra-articular calcaneal fracture (16 patients) with a large bony defect that underwent operative treatment with plate fixation and injectable calcium sulfate ($MIIG^{TM}$) with minimum follow-up of one year following. The mean age at time of surgery was 44.7 years (23 to 54). All of the cases were type 2 and 3 on the basis of Sanders classification. The lateral L shaped approach was used in all cases. Full weight bearing on the affected extremity was regained at an average 10 weeks postoperatively. Results: The mean Bohler angle was improved from $2^{\circ}$ ($-18.5{\sim}12.5^{\circ}$) preoperatively to $23.8^{\circ}$ ($12{\sim}37.5^{\circ}$) and the angle at last follow-up was $22.5^{\circ}$ ($11.5{\sim}37.5^{\circ}$), showing about 0.3 degree decline compared to postoperative Bohler angle. Only two case of whitish leakage of graft material but other complication were none. Conclusion: $MIIG^{TM}$ augumentation of displaced intra-articular calcaneal fracture with large bone defect seems to bo useful method for initial stabilized and plate fixation.

  • PDF

한국인에 대한 새로운 관절주위 잠김금속판의 해부학적 적합성: 사체를 이용한 연구 (Anatomic Conformity of New Periarticular Locking Plates for Koreans: A Biomechanical Cadaveric Study)

  • 윤용철;오종건;김영우;김학준;문홍주;김남렬
    • Journal of Trauma and Injury
    • /
    • 제26권3호
    • /
    • pp.163-169
    • /
    • 2013
  • Purpose: This study was conducted to confirm the anatomic conformity of the new periarticular locking plates designed by Zimmer on Korean adult bones and to identify the structures at risk during the application of these implants. Methods: The study was performed on the humerus, radius, and tibia of 10 adult cadavers(6 males and 4 females) procured from the cadaveric lab of our hospital. Anteroposterior (AP) and lateral X-rays were taken to confirm that the cadavers were free of any unusual lesions or anatomic variations. We used the 3.5-mm proximal humerus plate, 2.7-mm distal radius plate, 3.5- and 5.0-mm proximal tibia plates, and 3.5-mm distal tibia plate developed by Zimmer, Inc. (Zimmer periarticular locking plate). The longest plate from each group was used to confirm anatomical conformity. Standard approaches were used for each area, and soft tissue was retracted in order to pass the plate beneath the muscle. The position of the plate was confirmed using standard AP and lateral view X-rays. After this procedure had been completed, the region was dissected along the length of the implant to determine the conformity of the implant to bone and the penetrations of screws into the articular surface or violations of any vital structures, such as nerves, blood vessels, or tendons. Results: Excellent anatomical conformity was observed with Zimmer periarticular locking plates for Korean adults. The tibial nerve and the posterior tibial artery were found to be structures at risk when applying a distal tibial plate. Conclusion: Additional posterolateral fixation is recommended when dealing with cases of tibial plateau fracture when the fracture line extends to the posterolateral cortex. We recommend taking proper views using 10~15 degrees of internal rotation to ensure correct screw length and, thus, avoid penetration of vital structures and tendons.

Management of Traumatic C6-7 Spondyloptosis with Cord Compression

  • Choi, Man-Kyu;Jo, Dae-Jean;Kim, Min-Ki;Kim, Tae-Sung
    • Journal of Korean Neurosurgical Society
    • /
    • 제55권5호
    • /
    • pp.289-292
    • /
    • 2014
  • A case of total spondyloptosis of the cervical spine at C6-7 level with cord compression is described in a 51-year-old male. Because the bodies of C6 and 7 were tightly locked together, cervical traction failed. Then the patient was operated on by a posterior approach. Posterior stabilization and fusion were performed by C4-5 lateral mass and C7-T1 pedicle screw fixation and rod instrumentation with bridging both C4-5's rods to the C7-T1's extended ones. After C6 total laminectomy and foraminotomy, the C6 body was returned to its proper position. Secondly, anterior stabilization and fusion were performed by C6-7 discectomy with a screw-plate system. A postoperative lateral plain radiograph showed good realignment. In this case, we report the clinical presentation and discuss the surgical modalities of C6-7 total spondyloptosis and the failed close reduction.

The Effect of a Condylar Repositioning Plate on Condylar Position and Relapse in Two-Jaw Surgery

  • Jung, Gyu Sik;Kim, Taek Kyun;Lee, Jeong Woo;Yang, Jung Dug;Chung, Ho Yun;Cho, Byung Chae;Choi, Kang Young
    • Archives of Plastic Surgery
    • /
    • 제44권1호
    • /
    • pp.19-25
    • /
    • 2017
  • Background Numerous condylar repositioning methods have been reported. However, most of them are 2-dimensional or are complex procedures that require a longer operation time and a highly trained surgeon. This study aims to introduce a new technique using a condylar repositioning plate and a centric relation splint to achieve a centric relationship. Methods We evaluated 387 patients who had undergone surgery for skeletal jaw deformities. During the operation, a centric relation splint, intermediate splint, final centric occlusion splint, and condylar repositioning plate along with an L-type mini-plate for LeFort I osteotomy or a bicortical screw for bilateral sagittal split ramus osteotomy were utilized for rigid fixation. The evaluation included: a physical examination to detect preoperative and postoperative temporomandibular joint dysfunction, 3-dimensional computed tomography and oblique transcranial temporomandibular joint radiography to measure 3-dimensional condylar head movement, and posteroanterior and lateral cephalometric radiography to measure the preoperative and postoperative movement of the bony segment and relapse rate. Results A 0.3% relapse rate was observed in the coronal plane, and a 2.8% relapse rate in the sagittal plane, which is indistinguishable from the dental relapse rate in orthodontic treatment. The condylar repositioning plate could not fully prevent movement of the condylar head, but the relapse rate was minimal, implying that the movement of the condylar head was within tolerable limits. Conclusions Our condylar repositioning method using a centric relation splint and miniplate in orthognathic surgery was found to be simple and effective for patients suffering from skeletal jaw deformities.