• Title/Summary/Keyword: Lateral mass

Search Result 530, Processing Time 0.038 seconds

The Effects of a Thermal Annealing Process in IGZO Thin Film Transistors

  • Kim, Hyeong-Jun;Park, Hyung-Youl;Park, Jin-Hong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.289.2-289.2
    • /
    • 2016
  • In-Ga-Zn-O(IGZO) receive great attention as a channel material for thin film transistors(TFTs) as next-generation display panel backplanes due to its superior electrical and physical properties such as a high mobility, low off-current, high sub-threshold slope, flexibility, and optical transparency. For the purpose of fabricating high performance IGZO TFTs, a thermal recovery process above a temperature of $300^{\circ}C$ is required for recovery or rearrangement of the ionic bonding structure. However diffused metal atoms from source/drain(S/D) electrodes increase the channel conductivity through the oxidation of diffused atoms and reduction of $In_2O_3$ during the thermal recovery process. Threshold voltage ($V_{TH}$) shift, one of the electrical instability, restricts actual applications of IGZO TFTs. Therefore, additional investigation of the electrical stability of IGZO TFTs is required. In this paper, we demonstrate the effect of Ti diffusion and modulation of interface traps by carrying out an annealing process on IGZO. In order to investigate the effect of diffused Ti atoms from the S/D electrode, we use secondary ion mass spectroscopy (SIMS), X-ray photoelectron spectroscopy, HSC chemistry simulation, and electrical measurements. By thermal annealing process, we demonstrate VTH shift as a function of the channel length and the gate stress. Furthermore, we enhance the electrical stability of the IGZO TFTs through a second thermal annealing process performed at temperature $50^{\circ}C$ lower than the first annealing step to diffuse Ti atoms in the lateral direction with minimal effects on the channel conductivity.

  • PDF

An Experimental Study on Brake Judder via the Frequency Analysis of the Brake System and Vehicle System of a Commercial Vehicle (상용차량의 브레이크 시스템과 차량 시스템 주파수 분석을 통한 브레이크 저더의 실험적 고찰)

  • Moon, ll-Dong;Kim, Jong-Dae;Oh, Chae-Youn
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.12
    • /
    • pp.1131-1138
    • /
    • 2007
  • This paper studies experimentally on the building-up process for the amplitude of a commercial truck vibration induced by brake judder. A front axle drum equipped with a drum brake system is utilized for this experiment. A brake dynamo test, a real vehicle ride test and a real vehicle braking test are performed for the analysis of brake judder. The brake dynamo test measures judder by applying brake chamber pressures of 1, 2 and 3 bar at initial brake pad temperatures of $100^{\circ}C$ and $150^{\circ}C$. In order to assess the vertical acceleration at the front axle, the real vehicle ride test on a straight test road with velocities of 20, 40, 60 and 80 km/h is performed. The real vehicle braking test is carried out at the deceleration rate of 0.2g from a velocity of 90km/h for evaluating the vertical, lateral and longitudinal accelerations both at the front axle and at the cab floor under the driver's seat. The magnitudes and frequencies of the measured peak accelerations from the brake dynamo test, the real vehicle ride test and the real vehicle braking test are comparatively analyzed. This paper shows that the vibration produced by brake judder is built up due to the brake system's peak acceleration frequency being close to the vehicle ride mode's frequency.

The Analysis of GRF during Golf Swing with the Slopes (골프 스윙 시 경사면에 따른 지면 반력 분석에 관한 연구)

  • Moon, G.S.;Choi, H.S.;Hwang, S.H.;Kim, Y.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.187-194
    • /
    • 2007
  • The purpose of this study is to determine the characteristics of ground reaction force(GRF) in golf swing for various slopes of flat lie and uphill lies of 5 and 10 degrees. Five right-handed professional golfers were selected for the experiment and the 7 iron club was used. We used four forceplates to measure GRF and synchronized with the three-dimensional motion analysis system. Results showed that slope did not affect the total time for golf swing, but the time until the impact had a tendency to slightly increase for the uphill lie(p<0.05). The medial-lateral GRF of the right foot increased toward the medial direction during back swing, but less increases were found with the angle of uphill lie(p<0.05). The GRF of the left foot increased rapidly toward the medial direction at the uncocking and the impact during down swing, but decreased with the increase in the angle of uphill lie(p<0.05). The anterior-posterior GRF of both feet showed almost the same for different slopes. With the slopes, the vertical GRF of the right foot increased, but the vertical GRF of left foot decreased(p<0.05). Uphill lies would have negative effect to provide the angular momentum during back swing, restricting pelvic and trunk rotations, and to provide the precise timing and strong power during down swing, limiting movements of body's center of mass. The present study could provide valuable information to quantitatively analyze the dynamics of golf swing. Further study would be required to understand detailed mechanism in golf swing under different conditions.

Fire Characteristics of Flaming and Smoldering Combustion of Wood Combustibles Considering Thickness (목재 가연물의 두께에 따른 화염연소와 훈소상태에서의 화재특성)

  • Kim, Sung-Chan;Nam, Dong-Gun
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.67-72
    • /
    • 2015
  • A series of fire tests was conducted to examine the fire characteristics of flaming and smoldering combustion of engineered wood products, which have been widely used for furniture and finishing materials in buildings. The engineered wood products of MDF, plywood, and chipboard were ignited by a radiant cone heater with incident heat flux of $50kW/m^2$. During the fire test, key parameters representing the fire characteristics such as the heat release rate, yield rate of combustion product, and effective heat of combustion were quantified in terms of thickness. The tests show two peak points of HRRPUA due to lateral fire propagation in the initial stage, followed by later fire penetration through the specimen thickness. The mass loss rate of flaming combustion was 5 times higher than that of smoldering combustion, while the CO yield rate of smoldering combustion was 10 times higher than that of flaming combustion. This study can contribute to the understanding of fire behavior of wood combustibles and provide useful data for fire analysis.

Diagnostic Imaging of Nasal Lymphoma in a Cat (고양이에서 비강 림프종의 영상 진단 증례)

  • Jung, Joo-Hyun;Seo, Kyoung-Won;Chang, Jin-Hwa;Bae, Il-Hong;Kim, Dae-Yong;Yoon, Hwa-Young;Yoon, Jung-Hee;Choi, Min-Cheol
    • Journal of Veterinary Clinics
    • /
    • v.23 no.3
    • /
    • pp.361-365
    • /
    • 2006
  • A spayed female, 5-year-old, weighing 2.7 kg, domestic short hair cat was referred to Veterinary Medical Teaching Hospital, Seoul National University. The clinical signs of this patient were weight loss, sneezing, respiratory distress, nasal discharge, epistaxis, ocular discharge, left exophthalmos, and left facial edema and deformity. The laboratory tests represented mild leukocytosis. On the skull radiographs, soft tissue density filled nasal cavity with loss of turbinate detail was found. Destructive and lytic changes of the left nasal bone with soft tissue swelling were identified. On the thorax radiographs, there were a tracheobronchial lymph node swelling and a soft tissue round mass in the left caudal lung field. On computed tomographic scan images, asymmetrical destruction of turbinate and nasal septum and increased soft tissue opacity in the nasal cavity were identified. Destruction of the lateral maxillary bone, invasion to the left retrobulbar region, and craniodorsal deviation of the left eye were seen. Also, there was lysis of hard palate and cribriform plate. Invasion to the brain was found. The patient was diagnosed as nasal lymphoma by cytology and histopathology.

The Results and Complications of the C1-C2 Transarticular Screw Fixation Methods (축추-환추간 경관절 나사못 고정술 치료의 결과 및 합병증)

  • Choi, Jun-Woong;Yoon, Seung-Hwan;Park, Hyung-Chun;Park, Hyeon-Seon;Kim, Eun-Young;Ha, Yoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.3
    • /
    • pp.201-206
    • /
    • 2005
  • Objective: To evaluate the accuracy and safety of C1-C2 transarticular screw insertion, we retrospectively review surgical records and postoperative radiological findings. Methods: From January 2001 to October 2003, the C1-C2 transarticular screw fixation and posterior wiring with iliac bone grafts was performed in 16 patients. 6 patients had rheumatoid arthritis which caused cervical instability, 3 patients had os odontoideum, 3 patients had type 2 odontoid process fracture, 3 patients had traumatic transverse ligament injury and 1 patients who had been managed with C1-C2 wire fixation had psoriatic arthritis. Results: Osseous fusion was documented in 15 patients(93.8%). Only one patient was recorded screw loosening because of postoperative infection. One patient had only one screw placed because of abnormal anatomical structure, one patients was breakage of a Kirschner wire, and one screw was medial location to lateral mass of C1, but clinical results was excellent and radiological instability was not noted. Conclusion: The author's experience demonstrates that C1-C2 transarticular screw fixation with wired bone graft is a safe procedure with higher fusion rate but precaution is needed to avoid the neural damage, vertebral artery injury, and hardware failure.

Combined Open Door Laminoplasty with Unilateral Screw Fixation for Unstable Multi-Level Cervical Stenosis : A Preliminary Report

  • Son, Seong;Lee, Sang Gu;Park, Chan Woo;Kim, Woo Kyung
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.2
    • /
    • pp.83-88
    • /
    • 2013
  • Objective : The authors reviewed their experiences of combined surgery (open door laminoplasty with unilateral screw fixation) for unstable multi-level cervical stenosis, to clarify the situation regarding the surgical approach most appropriate for the treatment of diffuse unstable multi-level cervical stenosis. Methods : From January 2011 to January 2012, combined surgery was performed for unstable multi-level cervical stenosis by one surgeon at our institution. The subjects of this study were 6 men of mean age 53.7 years (range, 48-71) with a mean follow-up of 9.3 (range, 3-14) months. All imaging studies showed severe multi-level cervical stenosis with spinal cord signal change, and instability or kyphotic deformity. A retrospective review of clinical, radiological, and surgical data was conducted. Results : Average laminoplasty level was 4.8 and the average screw fixation level was 5.0. Japanese Orthopedic Association score improved from an average of 5.2 to 11.2 points. According to Nurick's grades and Odom's criteria, symptom improvement was statistically significant. On the other hand, Cobb's angle changes were not significant. Average operation time was 5.86 hours with an average blood loss of 460 mL. No significant surgical complication was encountered. Conclusion : Despite the small cohort and the short follow-up duration, the present study demonstrates that laminoplasty with unilateral screw fixation is a safe and effective treatment for unstable multi-level cervical stenosis.

Study of fission gas products effect on thermal hydraulics of the WWER1000 with enhanced subchannel method

  • Bahonar, Majid;Aghaie, Mahdi
    • Advances in Energy Research
    • /
    • v.5 no.2
    • /
    • pp.91-105
    • /
    • 2017
  • Thermal hydraulic (TH) analysis of nuclear power reactors is utmost important. In this way, the numerical codes that preparing TH data in reactor core are essential. In this paper, a subchannel analysis of a Russian pressurized water reactor (WWER1000) core with enhanced numerical code is carried out. For this, in fluid domain, the mass, axial and lateral momentum and energy conservation equations for desired control volume are solved, numerically. In the solid domain, the cylindrical heat transfer equation for calculation of radial temperature profile in fuel, gap and clad with finite difference and finite element solvers are considered. The dependence of material properties to fuel burnup with Calza-Bini fuel-gap model is implemented. This model is coupled with Isotope Generation and Depletion Code (ORIGEN2.1). The possibility of central hole consideration in fuel pellet is another advantage of this work. In addition, subchannel to subchannel and subchannel to rod connection data in hexagonal fuel assembly geometry could be prepared, automatically. For a demonstration of code capability, the steady state TH analysis of a the WWER1000 core is compromised with Thermal-hydraulic analysis code (COBRA-EN). By thermal hydraulic parameters averaging Fuel Assembly-to-Fuel Assembly method, the one sixth (symmetry) of the Boushehr Nuclear Power Plant (BNPP) core with regular subchannels are modeled. Comparison between the results of the work and COBRA-EN demonstrates some advantages of the presented code. Using the code the thermal modeling of the fuel rods with considering the fission gas generation would be possible. In addition, this code is compatible with neutronic codes for coupling. This method is faster and more accurate for symmetrical simulation of the core with acceptable results.

A Response to Postural Response to Sine Curve Vestibular Electric Stimulation during Standing (기립자세동안 전정기관에 인가된 정현파 전류자극에 대한 자세균형 응답)

  • Lee, Ah-Reum;Yu, Mi;Kim, Jin-Ho;Kim, Dong-Wook;Kim, Jung-Ja
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.3
    • /
    • pp.210-216
    • /
    • 2010
  • This study is vestibular electric stimulation applied between the mastoids during quiet standing elicits postural sway. The aim of this study was to characterize the postural sway response to continuous sinusoidal vestibular electric stimulation across various stimulus frequencies and amplitudes. Binaural bipolar sinusoidal vestibular electric stimulation was applied to the skin overlying the mastoid processes of 10 subjects while they stood on a force plate. The position of the center of pressure(COP) and signals at the feet are obtained on an force plate, while the head and whole body center of mass(COM) was measured with motion analysis system. The stimulus conditions included eight frequencies (1/64, 1/32, 1/16, 1/8, 1/4, 1/2, 1, and 2Hz) and six peak amplitudes (0.1, 0.25, 0.5, 0.7, 1 and 2mA). Each subject experienced one trial at each amplitude-frequency pair. The stimuli elicited sway in lateral plane in all subjects, as evidenced by changes in the stimulus frequency. Our results demonstrate that the vestibular system is sensitive to vestibular electric stimulation intensity changes and responds by altering the magnitude of the response accordingly.

Surgical Treatment of Craniovertebral Junction Instability : Clinical Outcomes and Effectiveness in Personal Experience

  • Song, Gyo-Chang;Cho, Kyoung-Suok;Yoo, Do-Sung;Huh, Pil-Woo;Lee, Sang-Bok
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.1
    • /
    • pp.37-45
    • /
    • 2010
  • Objective : Craniovertebral junction (CVJ) consists of the occipital bone that surrounds the foramen magnum, the atlas and the axis vertebrae. The mortality and morbidity is high for irreducible CVJ lesion with cervico-medullary compression. In a clinical retrospective study, the authors reviewed clinical and radiographic results of occipitocervical fusion using a various methods in 32 patients with CVJ instability. Methods : Thirty-two CVJ lesions (18 male and 14 female) were treated in our department for 12 years. Instability resulted from trauma (14 cases), rheumatoid arthritis (8 cases), assimilation of atlas (4 cases), tumor (2 cases), basilar invagination (2 cases) and miscellaneous (2 cases). Thirty-two patients were internally fixed with 7 anterior and posterior decompression with occipitocervical fusion, 15 posterior decompression and occipitocervical fusion with wire-rod, 5 C1-2 transarticular screw fixation, and 5 C1 lateral mass-C2 transpedicular screw. Outcome (mean follow-up period, 38 months) was based on clinical and radiographic review. The clinical outcome was assessed by Japanese Orthopedic Association (JOA) score. Results : Nine neurologically intact patients remained same after surgery. Among 23 patients with cervical myelopathy, clinical improvement was noted in 18 cases (78.3%). One patient died 2 months after the surgery because of pneumonia and sepsis. Fusion was achieved in 27 patients (93%) at last follow-up. No patient developed evidence of new, recurrent, or progressive instability. Conclusion : The authors conclude that early occipitocervical fusion to be recommended in case of reducible CVJ lesion and the appropriate decompression and occipitocervical fusion are recommended in case of irreducible craniovertebral junction lesion.