• 제목/요약/키워드: Lateral instability

검색결과 266건 처리시간 0.028초

뇌졸중 환자의 머리회전 각도가 내.외측 균형에 미치는 영향 (The Effect of Medio-lateral Balance to Head Rotation in Stroke Patient)

  • 이관섭;김중선
    • The Journal of Korean Physical Therapy
    • /
    • 제24권5호
    • /
    • pp.334-339
    • /
    • 2012
  • Purpose: This study was conducted in order to compare the ability to control postural sway during perturbation when stroke patients received postural sway induced by head rotation. Methods: This study included 15 stroke patients and 15 healthy adults. Each group was measured by 3D motion analysis for determination of the angle of the neck in static position and by balance performance monitor for estimation of swaying angle in both neutral posture and head rotation position. These results were then analyzed in order to compare the healthy control group and the stroke patients group. Results: In both static posture ($60.7{\pm}4.81$) and dynamic posture ($51.46{\pm}6.87$, $70.8{\pm}6.55$), significant decreases were observed in the angle of head rotation of the patient group, compared to the healthy group (p<0.05), and significant decreases were observed in the sway angle of the patient group when in the neutral position ($3.62{\pm}7$, $24{\pm}0.60$) and head rotation ($3.04{\pm}0.80$, $51.46{\pm}6.87$), compared to the healthy group (p<0.05). Conclusion: According to these findings, patients with stroke tend to restrict the ROM of head rotation and swaying angle in dynamic posture and maintain their posture instability using limitation of head movement relative to the trunk and sway angle of area which is larger than that of affected side in unaffected side.

한국의 젊은 남성에서 족관절 안정성에 대한 부하검사시의 결과 (Results in Stress Test in the Ankle Stability of Young Men in Korea)

  • 이경태;이영구;최병옥
    • 대한족부족관절학회지
    • /
    • 제12권1호
    • /
    • pp.36-40
    • /
    • 2008
  • Purpose: The purpose of this study is to find out the normal results in ankle on varus stress, valgus stress, and anterior draw stress in young men in korea. This would be helpful as the basic data of measuring of ankle instability for operational indication. Materials and Methods: Varus and Valgus stress anteroposterior radiographs and Anterior drawing stress lateral radiographs of 600 normal ankles were reviewed. First, A line parallel was drawn parallel to the articular surface of the distal tibia, and another line was drawn parallel to the articular surface of the talus on anteroposterior radiographs. The interior angle that subtended by these two lines was measured. Second, the reference point is located at the posterior border of the tibia, and the shortest distance from this point to the proximal posterior articular surface of the talus is measured. Results: There were 300 males and 600 ankles. The mean age overall was 21 years (19-22 years) old. The mean length of ankle on anterior draw stress was $5.54{\pm}3.33\;mm$. The mean a interior angle of ankle on varus stress was $0^{\circ}-8.93^{\circ}$, and on valgus stress $0^{\circ}-7.78^{\circ}$. Conclusion: We can consider for operational indication at over the 8.87 mm on anterior draw stress, over the $8.93^{\circ}$ on varus stress, and over the $7.78^{\circ}$ on valgus.

  • PDF

경추 전방 잠금식 금속판이 장기적으로 경추에 미치는 영향 (Long-term Effects on the Cervical Spine after Anterior Locking Plate Fixation)

  • 김근수
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권4호
    • /
    • pp.493-500
    • /
    • 2001
  • Objective : Anterior cervical locking plates are the devices for achieving anterior cervical spinal fusion. This study was conducted to evaluate the locking plate system regarding its long-term advantages and disadvantages in the view of interbody fusion rate, hardware-related failures, vertebral change close to the fusion segment and postoperative complications. Method : Eight-six patients, operated from Jan., 1996 to Jun. 1998, were followed-up for more than two years. All of the cases were fused with iliac bone graft and ORION locking plate(Sofamor Danek USA, Inc., Memphis, TN) fixation. The patients were discharged or transferred to rehabilitation department 2-7 days after operation. A comprehensive evaluation of the interbody fusion state, instrument failure, vertebral change and postoperative complications were made by direct interview and cervical flexion-extension lateral plain films. Results : There were 55 male and 31 female with a mean age of 45 years(18-75 years). The mean follow-up period was 29 months(24-43 months). Various disorders that were operated were 40 cervical discs, 6 cervical stenosis including OPLL, 2 infections, and 38 traumas. Fusion level was single in 59 cases, two levels of each disc space in 15 cases, and two levels after one corpectomy in 12 cases. There was no instrument failure. Pseudoarthrosis was observed in two cases(2%) without radiological instability. The other patients(98%) showed complete cervical fusion with stable instrument. Mild settling of interbody graft with upward migration of screws was found in 12 cases(14%). Anterior bony growth at the upper segment was found in 5 cases(6%). Postoperative foreign body sensation or dysphagia was observed in 12 cases(4%), and disappeared within one month in 7 cases and within six months in 4 cases. One patient complained for more than six months and required reoperation to remove paraesophageal granulation tissue. Conclusion : The results show that Orion cervical locking plate has some disadvantages of upward migration of screws, anterior bony growth at the upper segment, or possibility of esophageal compression even though it has advantages of high interbody fusion rate or low instrument failure. Author believe that anterior cervical locking plate in the future should be thinner, and should have short end from the screw hole, and movable screw with adequate stability.

  • PDF

The BioFlex System as a Dynamic Stabilization Device : Does It Preserve Lumbar Motion?

  • Zhang, Ho-Yeol;Park, Jeong-Yoon;Cho, Bo-Young
    • Journal of Korean Neurosurgical Society
    • /
    • 제46권5호
    • /
    • pp.431-436
    • /
    • 2009
  • Objective : This study examines whether functional motion is present at one or more years after Bioflex System placement. BioFlex System is a flexible rod system which has been used to preserve motion at the area of implantation. There has not been a scientific study showing how much motion is preserved after implantation. Methods : A total of 12 consecutive patients underwent posterior dynamic stabilization using the BioFlex System. Six patients were treated using a L3-4-5 construct and other six patients using a L4-5-S1 construct. Follow-up ranged from 12 to 33 months and standing neutral lateral, extension, flexion and posteroanterior (PA) radiographs were obtained at 3, 6, 9, and 12 months and at more than 12 months postoperatively. Range of motion (ROM), whole lumbar lordosis, and ROMs of motion segments from L2 to S1 were determined. Results : Patients with a L3-4-5 construct demonstrated a decrease in mean ROM for whole lumbar decreased from 40.08 to 30.77. Mean ROM for L3-4 (6.12 to 2.20) and L4-5 (6.55 to 1.67) also decreased after one year. Patients with a L4-5-S1 construct demonstrated L4-5 (8.75 to 2.70) and L5-S1 (9.97 to 3.25) decrease of mean ROM at one year postoperatively. Lumbar lordosis was preservep at both L3-4-5 and L4-5-S1 constructs. Clinical results showed significant improvements in both study groups. Conclusion : The present study provides preliminary information regarding the BioFlex motion preservation system. We conclude that the BioFlex System preserves functional motion to some degree at instrumented levels. However, although total lumbar lordosis was preserved, ROMs at implantation segments were lower than preoperative values.

Combined Open Door Laminoplasty with Unilateral Screw Fixation for Unstable Multi-Level Cervical Stenosis : A Preliminary Report

  • Son, Seong;Lee, Sang Gu;Park, Chan Woo;Kim, Woo Kyung
    • Journal of Korean Neurosurgical Society
    • /
    • 제53권2호
    • /
    • pp.83-88
    • /
    • 2013
  • Objective : The authors reviewed their experiences of combined surgery (open door laminoplasty with unilateral screw fixation) for unstable multi-level cervical stenosis, to clarify the situation regarding the surgical approach most appropriate for the treatment of diffuse unstable multi-level cervical stenosis. Methods : From January 2011 to January 2012, combined surgery was performed for unstable multi-level cervical stenosis by one surgeon at our institution. The subjects of this study were 6 men of mean age 53.7 years (range, 48-71) with a mean follow-up of 9.3 (range, 3-14) months. All imaging studies showed severe multi-level cervical stenosis with spinal cord signal change, and instability or kyphotic deformity. A retrospective review of clinical, radiological, and surgical data was conducted. Results : Average laminoplasty level was 4.8 and the average screw fixation level was 5.0. Japanese Orthopedic Association score improved from an average of 5.2 to 11.2 points. According to Nurick's grades and Odom's criteria, symptom improvement was statistically significant. On the other hand, Cobb's angle changes were not significant. Average operation time was 5.86 hours with an average blood loss of 460 mL. No significant surgical complication was encountered. Conclusion : Despite the small cohort and the short follow-up duration, the present study demonstrates that laminoplasty with unilateral screw fixation is a safe and effective treatment for unstable multi-level cervical stenosis.

신발굽 높이와 Wedge 위치 변화가 하지 근활성도에 미치는 영향 (Effect on the Lower Extremity Muscle Activity According to the Heel Height and Wedge Position)

  • 이현주;김소정;김순종;김혜지;박보람;박소영;유정화;태기식
    • 재활복지공학회논문지
    • /
    • 제8권4호
    • /
    • pp.291-297
    • /
    • 2014
  • 본 연구는 30명의 여성에게 내 외측 wedge 삽입과 함께 flated heel 또는 5cm heel을 착용하도록 한 후, 넙다리네갈래근 중 안쪽빗넓은근(VMO)과 가쪽넓은근(VL)의 근활성도를 측정하여 비교하였다. 연구 결과 내외측 wedge 모두에서 flated heel 군에서는 가쪽넓은근이, 5 cm heel 군에서는 안쪽빗넓은근의 근활성도가 높게 나타났으며 가쪽넓은근에 대한 안쪽빗넓은근의 근활성도비(% VMO/VL) 또한 5cm heel 군에서 유의하게 높게 나타났다. 이는 안쪽빗넓은근과 가쪽넓은근의 근활성도에 영향을 미치는 외적 변수가 wedge의 내외측 위치보다는 힐의 높이에 의함을 알 수 있었다. 차후 무릎통증이나 무릎 불안정성으로 인한 하지 재활훈련 또는 하지보조기 제작 시에 하지 근육의 선택적 활성화를 유도하기 위한 변수로써 heel 높이를 고려할 수 있을 것이다.

  • PDF

마찰을 고려한 노즈 랜딩기어의 비선형 쉬미 해석 (Non-linear Shimmy Analysis of a Nose Landing Gear with Friction)

  • 이미선;배재성;황재혁
    • 한국항공우주학회지
    • /
    • 제39권7호
    • /
    • pp.605-611
    • /
    • 2011
  • 쉬미는 항공기의 이착륙 시 랜딩기어가 주행도중 측방향 및 조향방향의 진동이 발생하는 현상이다. 쉬미 현상은 스트럿의 낮은 강성, 랜딩기어 내부의 유격, 휠의 불균형이나 마모된 부품 등으로 인해 발생하며, 항공기의 안정성을 저하시킨다. 본 연구는 소형항공기의 쉬미 안정성 검토를 위해 수행되었다. 수치해석을 위하여 소형항공기의 전방 착륙장치를 선형시스템으로 모델링하고 상태방정식을 수립하였다. 근궤적 기법을 이용한 주파수 영역 해석과 4차 Runge-Kutta 방법을 이용한 시간영역 해석을 통해 쉬미 현상을 예측하였고 주요 변수의 설계범위를 검토하였다. 현 착륙장치는 와셔의 압축력을 이용하여 조향 방향 마찰을 가함으로써 쉬미현상을 저감하는 기법을 채택하고 있으므로 마찰을 기술함수를 이용하여 선형화시키고 상태방정식에 적용하여 해석을 수행함으로써 쉬미의 발생이 저감되는 결과를 확인하였다.

전방 연부조직 충돌과 동반된 족관절 병변 (Ankle Lesions, Associated with Anterior Soft Tissue Impingement)

  • 성일훈;김석환;심규동;이준환;강창남
    • 대한족부족관절학회지
    • /
    • 제14권2호
    • /
    • pp.115-118
    • /
    • 2010
  • Purpose: To evaluate clinical features of ankle lesions, associated with anterior soft tissue impingement. Materials and Methods: We retrospectively reviewed 21 patients who had chronic anterior ankle pain as initial symptom and associated ankle lesions with anterior soft tissue impingement. Based on preoperative radiologic findings, physical examination intra-operative findings, appropriate procedures were done for lesions by either arthroscopic or minimal open procedure or combined. Clinical evaluation was done using American Orthopedic Foot and Ankle Society, ankle-hind foot score (AOFAS score) and visual analog scale (VAS) on last follow up. Results: Associated lesion(s) to anterior soft tissue impingement of the ankle were 16 cases of osteochondral lesion of talus, 14 cases of bony impingement, 6 cases of ankle lateral instability, 5 cases of loose body, 4 cases of os subfibulare. AOFAS score was $58.9\;{\pm}\;5.1$ preoperatively and $74\;{\pm}\;9.1$ on last follow up. Clinical satisfaction score using VAS showed excellent in 3 cases, good in 11, fair in 3, poor in 4. Conclusion: The patients who had anterior soft tissue impingement would have various associated lesions on their ankle. In such cases, preoperative counseling for variety of postoperative results would be needed.

정전분무에 의한 고점성 액체의 액적 생성 특성에 관한 실험적 연구 (An Experimental Study on Characteristics of Droplet Generation by Electrospraying for Highly Viscous Liquids)

  • 김상수;구본기
    • 대한기계학회논문집B
    • /
    • 제26권4호
    • /
    • pp.604-613
    • /
    • 2002
  • Generation characteristics of electrospray droplets for highly viscous liquid have been investigated by measuring size distributions of droplets emitted from the Taylor cone using glycerol solutions with various conductivities. Because of very small volatility of glycerol, droplet sizes can be measured by an aerodynamic size spectrometer (TSI Aerosizer DSP) with negligible evaporation of droplets. For highly conducting and viscous liquid, the sizes of the droplets electrosprayed from the Taylor cone are found to be relatively insensitive to applied voltages and the electrosprays assisted by the corona discharge call produce monodisperse droplets as long as the corona intensity is not too high. Near the minimum flow rate where a liquid cone is stable, the spray tends to consist of a one -peak monodisperse distribution of drop lets. However, at high flow rates, the spray bifurcates into bimodal distributions, which are consistent with the result of the previous study for less viscous liquids than our liquids. For liquid flow rates (Q) below 1 nl/s, the measured droplet diameters by the aerosizer are in the range of 0.30 to 1.2 ${\mu}{\textrm}{m}$ for the glycerol solutions. The diameters of monodisperse droplets scale approximately with $r^*=Q_$\tau$(Q$\tau$){^1/3}$ where $r^*$ is a characteristic length and $\tau$is the electrical relaxation time of the fluid. However, when compared with several represe ntative scaling laws, the droplet diameters are two to six factors greater than those predicted by the scaling laws. This may be closely related to the combined effect of the much higher viscosity and the electrical charge on the jet breakup of glycerol so solution.

주기적으로 회전진동하는 원주 후류의 Dynamic PIV 속도장 측정 (Dynamic PIV Measurements of Wake behind a Rotationally Oscillating Circular Cylinder)

  • 이정엽;이상준
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2007년도 추계학술대회
    • /
    • pp.134-137
    • /
    • 2007
  • The temporal evolution of wake behind a circular cylinder oscillating rotationally with a relatively high forcing frequency has been investigated experimentally using a dynamic PIV technique. Experiments were carried out with varying the frequency ratio $F_R\;(=f_f/f_n)$ in the range from 0.0 (stationary) to 1.6 at oscillation amplitude of ${\theta}_A=30^{\circ}$ and Reynolds number of $Re=4.14{\times}10^3$. Depending on the forcing condition ($F_R$), the flow was divided into three regimes; non-lock-on ($F_R=0.4$), transition ($F_R=0.8$, 1.6) and lock-on regimes ($F_R=1.0$) with markedly different flow structure in the near-wake region behind the cylinder. When the frequency ratio was less than 1.0 ($F_R{\le}1.0$), the rotational oscillatory motion of the cylinder decreased the length of the vortex formation region and enhanced the mutual interaction between large-scale vortices across the wake centerline. The entrainment of ambient fluid seemed to play an important role in controlling the near-wake flow and shear-layer instability. However, the flow characteristics changed markedly beyond the lock-on flow regime ($F_R=1.0$) due to high-frequency forcing. At $F_R=1.6$, the mutual interactions between the vortices shed from both sides of the cylinder were not so strong. Thereby, the flow entrainment and momentum transfer into the wake center region were reduced. In addition, the size of the large-scale vortices decreased since the lateral extent of the wake was suppressed.

  • PDF