• 제목/요약/키워드: Lateral drift ratio

검색결과 82건 처리시간 0.024초

실험자료를 기반한 국내 원형단면 철근콘크리트 휨교각의 손상수준 별 횡변위비 산정 (Estimation of Drift Ratio by Damage Level for Flexural RC Piers With Circular Cross-Section Based on Experimental Data in Korea)

  • 남현웅;홍기증;김익현
    • 한국지진공학회논문집
    • /
    • 제26권6호
    • /
    • pp.255-265
    • /
    • 2022
  • In order to determine fragility curves, the limit state of piers for each damage level is suggested in this paper based on the previous test results in Korea, including our test results. In previous studies, the quantitative measures for damage levels of piers have been represented by curvature ductility, lateral drift ratio, or displacement ductility. These measures are transformed to lateral drift ratios of piers for consistency, and the transformed values are compared and verified with our push-over test results for flexural RC piers with a circular cross-section. The test specimens are categorized concerning the number of lap-splices in the plastic hinge region and whether seismic design codes are satisfied or not. Based on the collected test results in Korea, including ours, the lateral drift ratio for each pier damage level is suggested.

유공강판의 횡력저항능력에 대한 실험적 연구 (Experimental Study on the Characteristics of the Lateral Load Resistance of Perforated Steel Plates)

  • 박정아;이영욱
    • 대한건축학회논문집:구조계
    • /
    • 제36권5호
    • /
    • pp.137-146
    • /
    • 2020
  • In this study, an experimental research was performed to find the characteristics of the lateral load resistance of perforated steel plates which could be developed to retrofit existing RC framed buildings. The Specimens are tested with variables such as aspect ratio of plate, the ratio of perforation area, and the ratio of perforated diameter to strip which is more than 0.6. The lateral load was applied with displacement control until to reach 3.5% drift ratio. Through the experimental results, it was shown that the maximum strength of all specimens were reached at around 0.5% drift ratio and maintained until 3.5% drift ratio. From results, the modified strength prediction formula was derived with the variable ratio of the perforated diameter to strip. To evaluate seismic retrofit performance of RC frames using perforated steel plate, a simple design process was presented.

중심코어를 가지는 저층 철근콘크리트 필로티 건물의 내진성능 (Seismic Performance of Low-rise Piloti RC Buildings with Concentric Core)

  • 윤태호
    • 한국산업융합학회 논문집
    • /
    • 제25권4_2호
    • /
    • pp.611-619
    • /
    • 2022
  • In this study, the seismic performance of low - rise piloti buildings with concentric core (shear wall) position is analysed and reviewed based on KDS 41. The prototype is selected among the constructed low - rise piloti buildings with concentric core designed based on KBC 2005 which was used for many low - rise piloti buildings construction. The seismic performance of the building shows plastic behavior in X-direction and elastic behavior in Y-direction. The inter-story drift is lager than that of concentric core case and is under the maximum allowed drift ratio. The displacement ratio of first story is much lager the that of upper stories, and the frame structure in the first story is evaluated as vulnerable to lateral force. Therefore, low - rise piloti buildings with concentric core need the diminishment of lateral displacement and reinforcement of lateral resistance capacity in seismic design and seismic retrofit.

Study on the performance indices of low-strength brick walls reinforced with cement mortar layer and steel-meshed cement mortar layer

  • Lele Wu;Caoming Tang;Rui Luo;Shimin Huang;Shaoge Cheng;Tao Yang
    • Earthquakes and Structures
    • /
    • 제24권6호
    • /
    • pp.439-453
    • /
    • 2023
  • Older brick masonry structures generally suffer from low strength defects. Using a cement mortar layer (CML) or steel-meshed cement mortar layer (S-CML) to reinforce existing low-strength brick masonry structures (LBMs) is still an effective means of increasing seismic performance. However, performance indices such as lateral displacement ratios and skeleton curves for LBMs reinforced with CML or S-CML need to be clarified in performance-based seismic design and evaluation. Therefore, research into the failure mechanisms and seismic performance of LBMs reinforced with CML or S-CML is imperative. In this study, thirty low-strength brick walls (LBWs) with different cross-sectional areas, bonding mortar types, vertical loads, and CML/S-CML thicknesses were constructed. The failure modes, load-carrying capacities, energy dissipation capacity and lateral drift ratio limits in different limits states were acquired via quasi-static tests. The results show that 1) the primary failure modes of UBWs and RBWs are "diagonal shear failure" and "sliding failure through joints." 2) The acceptable drift ratios of Immediate Occupancy (IO), Life Safety (LS), and Collapse Prevention (CP) for UBWs can be 0.04%, 0.08%, and 0.3%, respectively. For 20-RBWs, the acceptable drift ratios of IO, LS, and CP for 20-RBWs can be 0.037%, 0.09%, and 0.41%, respectively. Moreover, the acceptable drift ratios of IO, LS, and CP for 40-RBWs can be 0.048%, 0.09%, and 0.53%, respectively. 3) Reinforcing low-strength brick walls with CML/S-CML can improve brick walls' bearing capacity, deformation, and energy dissipation capacity. Using CML/S-CML reinforcement to improve the seismic performance of old masonry houses is a feasible and practical choice.

Experimental study on seismic performances of steel framebent structures

  • Liang, Jiongfeng;Gu, Lian S.;Hu, Ming H.
    • Earthquakes and Structures
    • /
    • 제10권5호
    • /
    • pp.1111-1123
    • /
    • 2016
  • To study seismic performance of steel frame-bent structure, one specimen with one-tenth scale, three-bay, and five-story was tested under reversed cyclic lateral load. The entire loading process and failure mode were observed, and the seismic performance indexes including hysteretic loops, skeleton curve, ductility, load bearing capacity, drift ratio, energy dissipation capacity and stiffness degradation were analyzed. The results show that the steel frame-bent structure has good seismic performance. And the ductility and the energy dissipation capacity were good, the hysteresis loops were in spindle shape, which shape were full and had larger area. The ultimate elastic-plastic drift ratio is larger than the limit value specified by seismic code, showing the high capacity of collapse resistance. It can be helpful to design this kind of structure in high-risk seismic zone.

Seismic behavior of steel frames with replaceable reinforced concrete wall panels

  • Wu, Hanheng;Zhou, Tianhua;Liao, Fangfang;Lv, Jing
    • Steel and Composite Structures
    • /
    • 제22권5호
    • /
    • pp.1055-1071
    • /
    • 2016
  • The paper presents an innovative steel moment frame with the replaceable reinforced concrete wall panel (SRW) structural system, in which the replaceable concrete wall can play a role to increase the overall lateral stiffness of the frame system. Two full scale specimens composed of the steel frames and the replaceable reinforced concrete wall panels were tested under the cyclic horizontal load. The failure mode, load-displacement response, deformability, and the energy dissipation capacity of SRW specimens were investigated. Test results show that the two-stage failure mode is characterized by the sequential failure process of the replaceable RC wall panel and the steel moment frame. It can be found that the replaceable RC wall panels damage at the lateral drift ratio greater than 0.5%. After the replacement of a new RC wall panel, the new specimen maintained the similar capacity of resisting lateral load as the previous one. The decrease of the bearing capacity was presented between the two stages because of the connection failure on the top of the replaceable RC wall panel. With the increase of the lateral drift, the percentage of the lateral force and the overturning moment resisted by the wall panel decreased for the reason of the reduction of its lateral stiffness. After the failure of the wall panel, the steel moment frame shared almost all the lateral force and the overturning moment.

부재배치에 따른 묶음튜브 구조의 전단지연현상 (The Shear Lag Phenomenon in Bundled Tube Structure According to the Arrangement of Structural Members)

  • 김영찬;김현
    • 한국안전학회지
    • /
    • 제21권3호
    • /
    • pp.81-86
    • /
    • 2006
  • The purpose of this study is to examine the effect of column spacing and beam size on the lateral displacement and shear lag phenomenon in bundled tube system. According to the parametric study in which the spacing of columns, the size of columns and girders in bundled tube were selected as a parameter, it is the most efficient to increase the size of the interior columns with the largest reduction of lateral drift if the steel tonnage of a frame can be increased. It was noticed that the shear lag was affected more by the exterior stiffness factor and ratio than by the interior ones when column spacing was changed, and when the size of column was changed, the reverse phenomenon was happened. And The change of column spacing affected shear lag, lateral drift, and tonnage more than that of column size or girder size.

록킹 거동을 하는 꺽쇠형 강재 댐퍼의 횡변형 방지 효과 (The Effect of Preventing Lateral Deformation of the Clamp Type Steel Damper in Rocking Behavior)

  • 이현호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권5호
    • /
    • pp.141-148
    • /
    • 2021
  • 본 연구에서는 강재 댐퍼의 횡변형을 방지할 수 있는 기술을 검토하여, 꺽쇠형 댐퍼에 적용하였다. 실험방법은 기존 연구와 같이 록킹 거동을 적용하였다. 평가변수는 횡변형 방지 상세 없는 기존 연구결과(SV-260)와 횡변형 방지 상세가 적용된 V-1과 V-1R이다. 여기서 V-1은 횡변형 방지상세가 댐퍼 하단부에 있으며, V-1R은 횡변형 방지상세가 하단부 및 상단부에 있다. 최대 하중 발현 시, 모멘트, 변위비 및 에너지 소산능력을 SV-260을 기준으로 상대 평가한 결과, SV-260 대비 V-1 및 V-1R의 최대모멘트는 1.22배, 1.36배 증가하였으며, 최대변위비는 2.41배, 2.92배 증가하였다. 또한 에너지 소산능력도 각각 1.39배, 1.52배 증가하였다. 따라서 강재 댐퍼에 횡변형 방지 상세를 적용한 것은 적절한 것으로 평가되었다.

Evaluating seismic demands for segmental columns with low energy dissipation capacity

  • Nikbakht, Ehsan;Rashid, Khalim;Mohseni, Iman;Hejazi, Farzad
    • Earthquakes and Structures
    • /
    • 제8권6호
    • /
    • pp.1277-1297
    • /
    • 2015
  • Post-tensioned precast segmental bridge columns have shown high level of strength and ductility, and low residual displacement, which makes them suffer minor damage after earthquake loading; however, there is still lack of confidence on their lateral response against severe seismic loading due in part to their low energy dissipation capacity. This study investigates the influence of major design factors such as post-tensioning force level, strands position, columns aspect ratio, steel jacket and mild steel ratio on seismic performance of self-centring segmental bridge columns in terms of lateral strength, residual displacement and lateral peak displacement. Seismic analyses show that increasing the continuous mild steel ratio improves the lateral peak displacement of the self-centring columns at different levels of post-tensioning (PT) forces. Such an increase in steel ratio reduces the residual drift in segmental columns with higher aspect ratio more considerably. Suggestions are proposed for the design of self-centring segmental columns with various aspect ratios at different target drifts.

용접 띠철근 보강된 콘크리트 기둥의 역학적 거동에 관한 실험적 연구 (An Experimental Study on the Structural Behavior of Concrete Columns Confined with Welded Reinforcement Grids)

  • 최창식
    • 콘크리트학회지
    • /
    • 제11권2호
    • /
    • pp.187-196
    • /
    • 1999
  • 지진다발 지역에서는 철근콘크리트 기둥의 단면을 합리적으로 구속함과 동시에 횡보강 띠철근의 세심한 배근등이 요구된다. 이러한 요구조건을 만족시키기 위한 보편적인 횡보강근 사용의 문제점으로는 높은 체적비(high volumetric ratio), 조밀한 간격(close spacings), 겹침(overlapping of hoops), 구부림(bends), 구부림 연장 (bend extensions), 시공상의 어려움과 콘크리트 타설상의 문제 등이다. 이러한 문제점을 해결하기 위한 한 방법으로는 요구되는 횡보강근의 체적비, 배역, 크기 등에 따라 이를 기조립, 용접하여 사용하는 것이다. 용접된 횡보강근의 사용은 겹침과 구부림, 구부림의 연장 등이 필요하지 않기 때문에 조립이 간편하고, 축방향 철근의 지지에 적합한 치수의 정확성과 재료를 절감시킬 수 있다. 더우기, 단면 내 횡보강 철근의 간격이 조밀해짐으로써, 코아 콘크리트 주변의 구속력을 균등히 분배시키게 되고, 이에 따라 코아 콘크리트의 거동을 향상시키는 결과를 얻을 수가 있다. 이에 본 연구에서는 이러한 용접 띠철근으로 보강된 철근콘크리트 기둥의 역학적 거동을 실험적으로 규명함과 동시에 철근콘크리트 기둥의 내진성능 향상을 위한 기초자료를 제공하고자 하였다. 그 결과 횡보강근의 강도와 연성에 영향을 미치지 않도록 용접됨과 동시에 충분한 신률을 가진다면, 용접된 격자형 횡보강근은 기둥의 띠철근으로써 사용가능한 것으로 판단된다. 특히, 용접된 격자형 횡보강근이 유효하게 거동하기 위하여는 1) 용접된 접합부위의 강도가 보강근의 모재강도 이상 2) 신률이 4% 이상이어야 할 필요가 있다.