• 제목/요약/키워드: Lateral Yielding Capacity

검색결과 45건 처리시간 0.026초

Performance-based drift prediction of reinforced concrete shear wall using bagging ensemble method

  • Bu-Seog Ju;Shinyoung Kwag;Sangwoo Lee
    • Nuclear Engineering and Technology
    • /
    • 제55권8호
    • /
    • pp.2747-2756
    • /
    • 2023
  • Reinforced Concrete (RC) shear walls are one of the civil structures in nuclear power plants to resist lateral loads such as earthquakes and wind loads effectively. Risk-informed and performance-based regulation in the nuclear industry requires considering possible accidents and determining desirable performance on structures. As a result, rather than predicting only the ultimate capacity of structures, the prediction of performances on structures depending on different damage states or various accident scenarios have increasingly needed. This study aims to develop machine-learning models predicting drifts of the RC shear walls according to the damage limit states. The damage limit states are divided into four categories: the onset of cracking, yielding of rebars, crushing of concrete, and structural failure. The data on the drift of shear walls at each damage state are collected from the existing studies, and four regression machine-learning models are used to train the datasets. In addition, the bagging ensemble method is applied to improve the accuracy of the individual machine-learning models. The developed models are to predict the drifts of shear walls consisting of various cross-sections based on designated damage limit states in advance and help to determine the repairing methods according to damage levels to shear walls.

지진하중을 받는 철근콘크리트 교각의 연성도 상관관계 (Ductility Relationship of RC Bridge Columns under Seismic Loading)

  • 손혁수;이재훈
    • 한국지진공학회논문집
    • /
    • 제7권4호
    • /
    • pp.51-61
    • /
    • 2003
  • 본 연구는 철근콘크리트 교각에 대한 새로운 내진설계법을 개발하기 위한 연구의 일환으로서, 축력과 함께 반복 횡하증을 받는 철근콘크리트 교각의 곡률연성도와 변위연성도의 상관관계를 분석하고 연성도 상관관계식을 제시함을 목적으로 한다. 이를 위하여, 반복하중을 받는 철근콘크리트 기둥의 횡하중-변위 포락곡선 실험결과를 비교적 정확하게 예측하며, 특히 변형능력 및 연성도에 대하여는 실험결과에 비하여 안전측의 결과를 제공하는 비선형해석 프로그램(NARCC)를 이용하였다. 해석의 대상 교각으로는, 단면지름, 형상비, 콘크리트 강도, 축방향철근 항복강도, 심부구속철근 항복강도, 축방향철근비, 축력비, 심부구속철근비 등을 주요변수로 하여, 총 7,200개의 철근콘크리트 나선철근 기둥 모델을 채택하였으며, 세 가지 항복변위의 기준을 적용하여 총 21,600개의 해석결과자료를 대상으로 상관관계를 분석하여 형상비를 주요변수로 한 곡률연성도와 변위연성도의 상관관계식을 제안하였다.

모래다짐말뚝과 널말뚝으로 처리된 연약점토지반의 거동 (Behavior of Soft Ground Treated with Sand Compaction Piles and Sheet Piles)

  • 유남재;정길수;박병수;김경수
    • 산업기술연구
    • /
    • 제26권B호
    • /
    • pp.93-99
    • /
    • 2006
  • Centrifuge model experiments were performed to investigate the confining effects of the sheet piles, installed to the sides of soft clay ground treated with sand compaction piles, on the bearing capacity and concentration ratio of composite ground. For the given g-level in the centrifuge model tests, replacement ratio of SCP and the width of surcharge loads on the surface of ground with SCP, the confining effects of installing the sheet piles on the edges of SCP ground on the bearing capacity, change of stress concentration ratio and failure mechanism were investigated. Kaolin, one of typical clay mineral, and Jumunjin standard sand were used as a soft clay ground and sand compaction pile irrespectively. As results of experiments, lateral confining effect by inserting the model sheet piles fixed to the loading plate was observed. For the strip surcharge loading condition, the yielding stress intensity in the form of the strip surcharge loads tends to increase with increasing the embedded depth of sheet piles. The stress concentration ratio was found not to be influenced consistently with the embedded depth of sheet piles whereas the effect of stress intensity on stress concentration ratio shows the general trend that values of stress concentration ratio are relatively high at the initial stage of loading and tend to decrease and converge to the certain values. For the failure mechanism in the case of reinforced with sheet piles, displacement behavior related to the punching failure, settlement right beneath the loading plate occurred since the soil was confined with sheet piles, was observed.

  • PDF

격자형 강합성 바닥판 이음부의 하중전달 거동에 관한 실험적 연구 (Experimental Study on the Load Transfer Behavior of Steel Grid Composite Deck Joint)

  • 신현섭
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권4호
    • /
    • pp.10-21
    • /
    • 2014
  • 프리캐스트 방식에 의해 제작이 가능한 격자형 강합성 바닥판의 이음부는 콘크리트 전단키와 고장력볼트 체결로 구성될 수 있으며, 이와같은 이음부 자체에 대한 휨 및 전단성능은 부재요소에 대한 실험을 통해 분석된 바 있다. 본 연구에서는 실제 바닥판 구조시스템에서 이음부에 의한 횡방향 하중전달 거동을 분석하고자, 길이 2.5m 및 폭 1m의 단위 바닥판 모듈 한쌍에 이음부를 설치한 실험체를 제작하고 중심 및 편심가력 휨실험을 하였다. 이음부에 하중이 직접 가해지는 중심재하 조건에서 고장력볼트의 설치개수가 30cm 간격 9개에서 60cm 간격 4개로 줄어 들 경우, 재하단계에 따라 이음부의 회전이 비교적 더 크게 증가하고, 이에 따라 바닥판 횡방향으로의 하중전달 정도가 감소함을 알 수 있었다. 그러나, 한쪽 바닥판의 중심에 집중하중이 가해지는 편심재하 조건의 경우에는 횡방향 하중전달 거동에 큰 차이가 없었다. 하중 재하방법별로 이음부의 거동을 비교한 결과, 집중하중에 대한 바닥판 횡방향으로의 하중분배 및 전달량은 이음부 자체의 성능뿐만 아니라 바닥판 슬래브의 펀칭전단에 의해서도 제한되는 것으로 분석되었다. 또한, 펀칭 전단파괴가 발생할 때까지 이음부의 고장력볼트가 항복하지 않은 점을 고려할 때, 이음부 고장력볼트의 설치개수를 4개에서 9개로 증가시키는 것은 실질적으로 강도 보다는 이음부 및 바닥판의 휨강성 성능 증가에 더 큰 영향을 미치는 것으로 사료된다.

Seismic behavior of K-type eccentrically braced frames with high strength steel based on PBSD method

  • Li, Shen;Wang, Chao-yu;Li, Xiao-lei;Jian, Zheng;Tian, Jian-bo
    • Earthquakes and Structures
    • /
    • 제15권6호
    • /
    • pp.667-685
    • /
    • 2018
  • In eccentrically braced steel frames (EBFs), the links are fuse members which enter inelastic phase before other structure members and dissipate the seismic energy. Based on the force-based seismic design method, damages and plastic deformations are limited to the links, and the main structure members are required tremendous sizes to ensure elastic with limited or no damage. Force-based seismic design method is very common and is found in most design codes, it is unable to determine the inelastic response of the structure and the damages of the members. Nowadays, methods of seismic design are emphasizing more on performance-based seismic design concept to have a more realistic assessment of the inelastic response of the structure. Links use ordinary steel Q345 (the nominal yielding strength $f_y{\geq}345MPa$) while other members use high strength steel (Q460 $f_y{\geq}460MPa$ or Q690 $f_y{\geq}690MPa$) in eccentrically braced frames with high strength steel combination (HSS-EBFs). The application of high strength steels brings out many advantages, including higher safety ensured by higher strength in elastic state, better economy which results from the smaller member size and structural weight as well as the corresponding welding work, and most importantly, the application of high strength steel in seismic fortification zone, which is helpful to popularize the extensive use of high strength steel. In order to comparison seismic behavior between HSS-EBFs and ordinary EBFs, on the basis of experimental study, four structures with 5, 10, 15 and 20 stories were designed by PBSD method for HSS-EBFs and ordinary EBFs. Nonlinear static and dynamic analysis is applied to all designs. The loading capacity, lateral stiffness, ductility and story drifts and failure mode under rare earthquake of the designs are compared. Analyses results indicated that HSS-EBFs have similar loading capacity with ordinary EBFs while the lateral stiffness and ductility of HSS-EBFs is lower than that of EBFs. HSS-EBFs and ordinary EBFs designed by PBSD method have the similar failure mode and story drift distribution under rare earthquake, the steel weight of HSS-EBFs is 10%-15% lower than ordinary EBFs resulting in good economic efficiency.

Performance of innovative composite buckling-restrained fuse for concentrically braced frames under cyclic loading

  • Mohammadi, Masoud;Kafi, Mohammad A.;Kheyroddin, Ali;Ronagh, Hamid R.
    • Steel and Composite Structures
    • /
    • 제36권2호
    • /
    • pp.163-177
    • /
    • 2020
  • Concentrically Braced Frames (CBFs) are commonly used in the construction of steel structures because of their ease of implementation, rigidity, low lateral displacement, and cost-effectiveness. However, the principal disadvantage of this kind of braced frame is the inability to provide deformation capacity (ductility) and buckling of bracing elements before yielding. This paper aims to present a novel Composite Buckling Restrained Fuse (CBRF) to be utilized as a bracing segment in concentrically braced frames that allows higher ductility and removes premature buckling. The proposed CBRF with relatively small dimensions is an enhancement on the Reduced Length Buckling Restrained Braces (RL-BRBs), consists of steel core and additional tensile elements embedded in a concrete encasement. Employing tensile elements in this composite fuse with a new configuration enhances the energy dissipation efficiency and removes the tensile strength limitations that exist in bracing elements that contain RL-BRBs. Here, the optimal length of the CBRF is computed by considering the anticipated strain demand and the low-cyclic fatigue life of the core under standard loading protocol. An experimental program is conducted to explore the seismic behavior of the suggested CBRF compare with an RL-BRB specimen under gradually increased cyclic loading. Moreover, Hysteretic responses of the specimens are evaluated to calculate the design parameters such as energy dissipation potential, strength adjustment factors, and equivalent viscous damping. The findings show that the suggested fuse possess a ductile behavior with high energy absorption and sufficient resistance and a reasonably stable hysteresis response under compression and tension.

The effect of cyclic loading on the rubber bearing with slit damper devices based on finite element method

  • Saadatnia, Mahdi;Riahi, Hossein Tajmir;Izadinia, Mohsen
    • Earthquakes and Structures
    • /
    • 제18권2호
    • /
    • pp.215-222
    • /
    • 2020
  • In this paper, slit steel rubber bearing is presented as an innovative seismic isolator device. In this type of isolator, slit steel damper is an energy dissipation device. Its advantages in comparison with that of the lead rubber bearing are its simplicity in manufacturing process and replacement of its yielding parts. Also, slit steel rubber bearing has the same ability to dissipate energy with smaller value of displacement. Using finite element method in ABAQUS software, a parametric study is done on the performance of this bearing. Three different kinds of isolator with three different values of strut width, 9, 12 and 15 mm, three values of thickness, 4, 6 and 8 mm and two steel types with different yield stress are assessed. Effects of these parameters on the performance characteristics of slit steel rubber bearing are studied. It is shown that by decreasing the thickness and strut width and by selecting the material with lower yield stress, values of effective stiffness, energy dissipation capacity and lateral force in the isolator reduce but equivalent viscous damping is not affected significantly. Thus, by choosing appropriate values for thickness, strut width and slit steel damper yield stress, an isolator with the desired behavior can be achieved. Finally, the performance of an 8-storey frame with the proposed isolator is compared with the same frame equipped with LRB. Results show that SSRB is successful in base shear reduction of structure in a different way from LRB.

대형기둥 적용을 위한 철근콘크리트기둥-강재보 접합부의 내진성능 (Seismic Performance of RC Column-Steel Beam Connections for Large Columns)

  • 박홍근;이호준;김창수;황현종
    • 한국강구조학회 논문집
    • /
    • 제28권4호
    • /
    • pp.231-242
    • /
    • 2016
  • 대형기둥의 제작성과 시공성을 고려한 철근콘크리트기둥-강재보 접합부의 상세를 제안하였으며, 이를 적용한 접합부의 내진성능을 연구하였다. 접합부의 보강을 위하여, 교차보, 스터드, U형 타이 등의 상세를 고려하였다. 내진성능의 평가를 위해, 2/3 스케일의 대형내부접합부에 대하여 반복가력실험을 수행하였다. 실험체들은 층간변위비 4.0%를 넘는 우수한 변형능력을 발휘하였으며, 보의 항복과 접합부의 항복이 동시에 발생하였다. 최종적으로는, 접합부의 전단파괴로 하중이 감소하였다. 실험강도는 기존 설계모델과 비교되었다.

Performance comparison of shear walls with openings designed using elastic stress and genetic evolutionary structural optimization methods

  • Zhang, Hu Z.;Liu, Xia;Yi, Wei J.;Deng, Yao H.
    • Structural Engineering and Mechanics
    • /
    • 제65권3호
    • /
    • pp.303-314
    • /
    • 2018
  • Shear walls are a typical member under a complex stress state and have complicated mechanical properties and failure modes. The separated-elements model Genetic Evolutionary Structural Optimization (GESO), which is a combination of an elastic-plastic stress method and an optimization method, has been introduced in the literature for designing such members. Although the separated-elements model GESO method is well recognized due to its stability, feasibility, and economy, its adequacy has not been experimentally verified. This paper seeks to validate the adequacy of the separated-elements model GESO method against experimental data and demonstrate its feasibility and advantages over the traditional elastic stress method. Two types of reinforced concrete shear wall specimens, which had the location of an opening in the middle bottom and the center region, respectively, were utilized for this study. For each type, two specimens were designed using the separated-elements model GESO method and elastic stress method, respectively. All specimens were subjected to a constant vertical load and an incremental lateral load until failure. Test results indicated that the ultimate bearing capacity, failure modes, and main crack types of the shear walls designed using the two methods were similar, but the ductility indexes including the stiffness degradation, deformability, reinforcement yielding, and crack development of the specimens designed using the separated-elements model GESO method were superior to those using the elastic stress method. Additionally, the shear walls designed using the separated-elements model GESO method, had a reinforcement layout which could closely resist the actual critical stress, and thus a reduced amount of steel bars were required for such shear walls.

Partial Confinement Utilization for Rectangular Concrete Columns Subjected to Biaxial Bending and Axial Compression

  • Abd El Fattah, Ahmed M.;Rasheed, Hayder A.;Al-Rahmani, Ahmed H.
    • International Journal of Concrete Structures and Materials
    • /
    • 제11권1호
    • /
    • pp.135-149
    • /
    • 2017
  • The prediction of the actual ultimate capacity of confined concrete columns requires partial confinement utilization under eccentric loading. This is attributed to the reduction in compression zone compared to columns under pure axial compression. Modern codes and standards are introducing the need to perform extreme event analysis under static loads. There has been a number of studies that focused on the analysis and testing of concentric columns. On the other hand, the augmentation of compressive strength due to partial confinement has not been treated before. The higher eccentricity causes smaller confined concrete region in compression yielding smaller increase in strength of concrete. Accordingly, the ultimate eccentric confined strength is gradually reduced from the fully confined value $f_{cc}$ (at zero eccentricity) to the unconfined value $f^{\prime}_c$ (at infinite eccentricity) as a function of the ratio of compression area to total area of each eccentricity. This approach is used to implement an adaptive Mander model for analyzing eccentrically loaded columns. Generalization of the 3D moment of area approach is implemented based on proportional loading, fiber model and the secant stiffness approach, in an incremental-iterative numerical procedure to achieve the equilibrium path of $P-{\varepsilon}$ and $M-{\varphi}$ response up to failure. This numerical analysis is adapted to assess the confining effect in rectangular columns confined with conventional lateral steel. This analysis is validated against experimental data found in the literature showing good correlation to the partial confinement model while rendering the full confinement treatment unsafe.