TEM Stud of GaN Thick Film Crystals Grown by HVPE

  • 송세안;이성국
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.121-121
    • /
    • 1999
  • Gallium nitride (GaN) semiconductor is intensively under investigation for commercialization of short wavelength light emitting devices and laser diodes. One of serious obstacles to overcome is to reduce the defect density in GaN film grown by various techniques such as MOCVD, HVPE, etc. Many research groups including SAIT are trying to improve the defect density to 106-107/cm2 from the level of 108-1010/cm2. We have investigated epitaxial growth behaviour of GaN thin and thick films under hidride vapour phase epitaxy (HVPE) condition. In this report, we present the microstructural and crystallographical characteristics of the GaN films grown on sapphire (0001) substrate which were studied by both conventional and high-resolution transmission electron microscopy (TEM). Also we present some microscopic analysis results obtained from GaN films grown by ELO(dpitzsial lateral overgrowth)-HVPE and from GaN quantum well structures grown by MOCVD. Another serious problem in growing GaN thick film by HVPE is internal micro-cracks. We also comment the origin of the micro-crack.

  • PDF

Orbital Dirofilariasis in Iran: A Case Report

  • Tavakolizadeh, Sepideh;Mobedi, Iraj
    • Parasites, Hosts and Diseases
    • /
    • v.47 no.4
    • /
    • pp.397-399
    • /
    • 2009
  • Dirofilariasis is a common parasitic disease in both domestic and wild animals around the world, with canines as the principal reservoir host and mosquitoes as the vector. Human ophthalmic dirofilariasis is an uncommon condition, but there have been reports from many parts of the world, including Africa, Australia, the Americas, Europe, and Asia. Ophthalmic involvement with Dirofilaria may present itself as periorbital, subconjunctival, orbital, or intraocular infections. In this report, we present a case of orbital dirofilariasis with lateral rectus muscle involvement. To our knowledge, this is the first orbital dirofilariasis case reported in Iran. Although debulking of the tumor usually leads to resolution, our patient showed an episode of recurrence after biopsy. Complete recovery was achieved after a spontaneous discharge, without the need for systemic medication.

Numerical Analysis of Emission-type THz NSOM (Emission-type THz NSOM 에 대한 수치해석)

  • Lee, Kyoun-Gin;Yun, Seok-Ho;Park, Hong-Kyu;Kim, Jeong-Hoi;Han, Hea-Wook
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.183-184
    • /
    • 2006
  • The simulation on the mechanism of terahertz NSOM(near-field scanning optical microscopy) have been investigated. Based on experimental results, we have demonstrated the antenna effects on the coupling between a metal tip and substrate for an emission-type terahertz NSOM. It has been found that the lateral resolution can be estimated by a simplified model using an infinitesimal dipole in the substrate.

  • PDF

Development of Aspheric Surface Profilometry using 2nd Derivative (형상의 이차미분을 이용한 비구면 형상측정기술 개발)

  • Kim, Byoung-Chang
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.2
    • /
    • pp.104-109
    • /
    • 2011
  • I present a method of aspheric surface profile measurement using 2nd derivative of local area profile. This method is based on the principle of curvature sensor which measures the local 2nd derivative under test along a line. The profile is then reconstructed from the data on the each point. Unlike subaperture-stiching method and slope detection method, 2nd derivative method has strong points from a geometric point of view in measuring the aspheric surface profile. The second derivative terms of surface profile is an intrinsic property of the test piece, which is independent of its position and tip-tilt motion. The curvature is measured at every local area with high accuracy and high lateral resolution by using White-light scanning interferometry.

A Scanning Flow Impedance Micrscope (유체역학 현상을 이용한 현미경 검사법 개발)

  • Kim, Tae-Young;Kim, Dong-Kwon;Kim, Sung-Jin
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2670-2675
    • /
    • 2008
  • We introduce a new type of surface microscope using hydrodynamic phenomena. The fluid flow through the opening of the pipette probe is blocked at short distances between the probe and the surface, thus increasing the pressure loss. Therefore, a scanning flow impedance microscope (SFIM) can image the surface topology by scanning the probe with measuring the pressure loss. The SFIM can display the topology regardless of surface hardness, surface electrical conductivity, and surrounding fluid. The present letter contains the first experimental results on surface topography obtained with this novel microscope. The preliminary results in air demonstrate the lateral resolution of the SFIM is very close to the inner diameter of the probe.

  • PDF

Salvage Approaches for Maintaining the Eye Globe in a Glaucomatous Patient with Severe Unilateral Exophthalmos

  • Kim, Eunjik;Yun, Sungho;Kwon, Young-Sam
    • Journal of Veterinary Clinics
    • /
    • v.34 no.2
    • /
    • pp.123-125
    • /
    • 2017
  • An eight-year-old Shih-Tzu dog was referred to Kyungpook National University Veterinary Medical Teaching Hospital because of severe glaucoma and exophthalmos. The symptoms included severe buphthalmos, conjunctival hyperemia, focal dried cornea and discomfort in the affected eye. Although enucleation was considered as a potential intervention measure in light of the severity of symptoms, it was possible to save the globe and relieve symptoms through evisceration, intraocular prosthesis implantation, and lateral canthoplasty. Our experience with this case suggests that symptomatic salvage therapy, rather than enucleation, is an appropriate approach for resolution of exopthalmos and other complications associated with glaucoma surgery.

Development of Image-space Telecentric Lens for Intra-Oral 3D Scanner

  • Kim, Tae Young;Shin, Min-Ho;Chang, Ryungkee;Kim, Young-Joo
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.3
    • /
    • pp.303-310
    • /
    • 2015
  • An image-space telecentric lens for an intra-oral 3D scanner was designed and fabricated for dental application. Since a telecentric function can provide the same results regardless of image plane position, it helps to realize a more accurate image for an intra-oral scanner. The performance of the designed lens meets the required properties for HD resolution. In particular, lateral color is corrected within 1 pixel. This system achieves depth of focus of more than 3 mm. For user convenience, the developed system consists of a prism part and an imaging part. Both parts are optimized to reduce the front size and weight of the system. In order to make the parallax sights, parallax angle was determined to be 8 degrees between two optical systems.

Detection System for Sub-micrometer Defects of a Photo-mask Using On-axis Interference between Reflected and Scattered Lights

  • Lee, Sangon;Jo, Jae Heung;Kim, Jong Soo;Moon, Il Kweon
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.1
    • /
    • pp.73-80
    • /
    • 2013
  • In the process of lithography using ultra violet light sources for semiconductor devices, most of defects are made by sub-micrometer pollutants generated at photochemical reactions. We proposed and developed a novel vibration-insensitive on-axis interferometer with a sub-micrometer lateral resolution by using the interference between two beams: one scattered from defects and the other reflected from a reference area without defects. The proposed system was successfully demonstrated to detect a small Al defect of 0.5 ${\mu}m$ diameter within the inspection time of less than 30 minutes over the area of the photo-mask which is 6 inch by 6 inch square.

Development of confocal scanning microscopy using acousto-optica1 deflector

  • J.W. Seo;D.K. Kang;H.G. Yun;Kim, K.H.;D.G. Gweon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.161.6-161
    • /
    • 2001
  • Confocal scanning microscopy (CSM) has an important role as the three-dimensional profiler. An image distribution can be reconstructed by a correlation analysis of spots with the bandwidth of radio frequency. But it is a serious problem for the high performance to align the optical components. Especially, the parasitic motion of focus on the detector gives rise to the fatal distortion of an image profile named the extinction effect while using acousto-optical(AO) deflector. An image profile can be regenerated in CSM with many advantages of non-contact, high speed and high resolution comparatively. In addition to the axial response of the primary focus, the lateral movement of it gives a necessity of the unitary lens to the scanning system. While using the beam deflector, the pupil of beam may be fixed at the nominal position. Furthermore, the use of a deflector may result in ...

  • PDF

A Numerical Study on the Interaction of Ulleung Warm Eddy with Topography and Lateral Boundary (울릉 난수성 Eddy와 해저지형과의 상호작용에 관한 수치모델 연구)

  • Lim, Keun-Sik;Kim, Kuh
    • 한국해양학회지
    • /
    • v.30 no.6
    • /
    • pp.565-583
    • /
    • 1995
  • We have used a nonlinear quasi-geostrophic model to study effects of lateral friction and bottom topography on the motion of warm eddies. The two empirical orthogonal functions of the stream function, accounting for the vertical structure, represent the barotropic and first baroclinic dynamic modes. This model is integrated 360 days on a 1000 km ${\times}$ 1000 km domain with a resolution of 10 km ${\times}$ 10 km including both the thermocline and idealized topography of the East Sea. Prescribed inflow through the Korea Strait is compensated by outflow through the Tsugaru Strait. The balance between the nonlinear advection term and the planetary ${\beta}$-effect tends to make northward movement of warm eddy over a flat bottom. The motion of a warm eddy over a sloping topography can be dominated by the nonlinear advection, while nonlinearity plays a secondary role over a flat topography. For eddies dispersing over topography, the nonlinear tendency is a function of time. For a strong warm eddy, northward propagation can occur. For intermediate strength of eddies one might expect a balance between the nonlinear term and the topographic ${\beta}$-effect. As nonlinearity decreases with eddy dispersion, southward motion along the slope may occur by such as a topographic Rossby wave. Our numerical simulations have confirmed the importance of lateral friction on eddy motions, in such a way that the northward penetration of the warm eddy increases drastically by the decrease of the lateral friction. The northward motion of warm eddy can be prevented by reducing the Reynolds number sufficiently. We have also demonstrated the crucial role of topographic effects in the eddy motion process.

  • PDF