• Title/Summary/Keyword: Latent heat storage system

검색결과 95건 처리시간 0.025초

태양열-잠열축열시스템의 온실보온특성 (A Study on the Greenhouse Heating of Solar Energy - Latent Heat Storage System -)

  • 송현갑;류영선
    • 생물환경조절학회지
    • /
    • 제1권1호
    • /
    • pp.14-20
    • /
    • 1992
  • For the high quality and low cost agricultural crops in greenhouse cultivation, it is necessary to use natural energy as much as possible. In order to reduce the fossil fuel consumption and maximize the solar energy utilization in greenhouse heating, a latent heat storage material was developed as a relatively highly concentrative solar energy storage medium. And a solar energy-latent heat storage system was designed and constructed. The experimental research on greenhouse heating effect of the system was performed.

  • PDF

그린하우스 난방을 위한 열펌프-잠열축열 시스템 연구 (A Study on the Heat pump - Latent Heat Storage System for the Greenhouse Heating)

  • 송현갑;노정근;박종길;강연구;김현철
    • Journal of Biosystems Engineering
    • /
    • 제23권2호
    • /
    • pp.147-156
    • /
    • 1998
  • It is desirable to use the renewable energy for the greenhouse heating in winter season, it make possible not only to save fossil fuel and conserve green environment but also to promote the quality of agricultural products and reduce the agricultural production cost. In this study the heat pump - PCM latent heat storage system has been developed to use the natural energy as much as possible for the thermal environment control of greenhouse. The coefficient of performance (COP) of the heat pump system was 3~4 with the ambient temperature ranging from 8$^{\circ}C$ to -8$^{\circ}C$, and greenhouse heating effect of the heat pump-PCM latent heat storage system on the basis of the ambient temperature was about 12-15$^{\circ}C$.

  • PDF

잠열축열요소의 열전달에 관한 컴퓨터 시뮬레이션 (Computer Simulation for Heat Transfer Analysis of Latent Heat Storage Units)

  • 류영선;송현갑;조한근
    • Journal of Biosystems Engineering
    • /
    • 제17권4호
    • /
    • pp.336-343
    • /
    • 1992
  • In this study, to obtain basic information for the design of a latent heat storage system, (1) the cylindrical type and the rectangular type of latent heat storage elements were designed, (2) the finite element method was adopted for the prediction of temperature profile of phase change material in heating and cooling process, and (3) experiments were performed to verify the numerical solutions, and then (4) the optimum size of latent heat storage units was predicted by the computer simulation. The results could be summarized as follows : (1) In cooling process, the predicted temperatures of latent heat storage units by computer simulation were in good agreement with measured. (2) The effective diameter of cylindrical element was observed to be 28 mm and the effective thickness of rectangular element was observed to be 21 mm.

  • PDF

The Cooling Characteristics of Clathrate Compound according to Concentration of TMA

  • Lee, Jong-In;Kim, Chang-Oh;Chung, Nak-Kyu
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제17권1호
    • /
    • pp.32-36
    • /
    • 2009
  • The ice storage system uses water for low temperature latent heat storage. However, a refrigerator capacity is increased and COP is decreased due to supercooling of water in the course of phase change from solid to liquid. This study investigates the cooling characteristics of the TMA-water clathrate compound including TMA (Tri-methyl-amine, $(CH_3)_3N$) of $20{\sim}25wt%$ as a low temperature latent heat storage material. The results showed that the phase change temperature and the specific heat is increased and the supercooling degree is decreased as the weight concentration of TMA increased. Especially, the clathrate compound containing TMA 25 wt% has the average phase change tempera ture of $5.8^{\circ}C$, the supercooling degree of $8.0^{\circ}C$ and the specific heat of 3.499 kJ/kgK in the cooling process. This can lead to reduction of operation time of refrigerator in low temperature latent heat storage system and efficiency improvement of refrigerator COP and overall system. Therefore, energy saving and improvement of utilization efficiency are expected.

잠열축열시스템의 축열과정에서 자연대류의 영향에 관한 연구 (Effect of Natural Convection on the Heat Transfer in a Latent Heat Storage System)

  • 유승남;한귀영
    • 태양에너지
    • /
    • 제19권2호
    • /
    • pp.29-36
    • /
    • 1999
  • Heat transfer characteristics of a low temperature latent heat storage system during the heat storage stage was examined for the circular finned tubes using fatty acid which shows the big density difference during melting as phase change materials. The heat storage vessel has the dimension of 530 mm height, 74 mm inside diameter and inner heat transfer tube is 480 mm in height and 13.5 mm outside diameter. Hot water was employed as the heat transfer fluid. During the heat storage stage, it was found that both conduction and natural convection were the major heat transfer mechanism. It was also found that the effect of natural convection on the heat transfer was more significant for the unfinned tube system than that for the finned tube system. The experimentally determined overall heat transfer coefficients were in the range of $50{\sim}250W/m^2K$ and the correlation for natural convection heat transfer as a function of Nusselt and Rayleigh number was proposed.

  • PDF

2-PCM 잠열축열 시스템의 열역학적 성능 (Thermodynamic performance of 2-PCM latent heat thermal energy storage system)

  • 이세균;우정선;이재효;김한덕
    • 설비공학논문집
    • /
    • 제12권2호
    • /
    • pp.189-199
    • /
    • 2000
  • This paper investigates the thermodynamic performance of latent heat thermal energy storage system using two phase change materials(2-PCM system). The thermodynamic merit of using 2-PCM is clear in terms of exergetic efficiency, which is substantially higher than that of 1-PCM system. Optimum phase change temperature to maximize the exergetic efficiency exists for each case. The heat transfer area ratio of high temperature storage unit, X, becomes another important parameter for 2-PCM system if the phase change temperatures of given materials are different from those of optimum conditions. It is a good approximation for X$_{opt}$ to be 0.5 when optimum phase change temperatures are used. Otherwise X$_{opt}$ is determined differently as a function of given phase change temperatures.res.

  • PDF

잠열 축열-바이오 세라믹 온돌의 난방 특성 - 온돌의 역사적 고찰 및 실험적 분석을 중심으로 - (Floor Heating Characteristics of Latent Heat Storage-Bioceramic Ondal - Focused on Historical research and Expermental Analysis -)

  • 송현갑;유영선
    • 태양에너지
    • /
    • 제15권1호
    • /
    • pp.13-28
    • /
    • 1995
  • 온돌의 효시인 화덕은 바닥에 자갈을 깔고 그 위에 진흙을 덮었으며, 주위에 큰돌을 놓아 불을 피워 돌과 흙에 열을 저장하여 이용하였으며, 이는 열저장 측면에서 주시할만한 난방법이었다. 현재의 한국식 주거용 난방시설은 연탄, 석유 및 가스 보일러를 이용한 온수순환온돌로서 전통온돌에서 사용한 돌과 흙같은 축열매체가 사용되고 있지 않다. 축열매체를 사용하고 있지 않기 때문에 온돌바닥면과 난방공간과의 온도차가 심하게 되어 쾌적도가 떨어지므로 난방열을 지속적으로 공급해야 하는 어려움이 있다. 이와 같은 현재의 난방법을 개선기 위하여, 본 연구에서는 잠열축열재와 바이오세라믹으로 구성된 온돌을 개발하였고, 그 난방특성을 실험적으로 분석하였다.

  • PDF

3중관 튜브형 잠열 축열조에서의 열전달 특성 연구 (Heat transfer characteristics of Triple-Tube Type Latent Heat Storage Tank)

  • 이욱균;한귀영;강용혁
    • 한국태양에너지학회 논문집
    • /
    • 제21권1호
    • /
    • pp.71-82
    • /
    • 2001
  • The heat transfer experiment in a latent heat storage tank as a solar energy storage system for the hot water supply was carried out. The latent heat storage tank was consisted of triple - tube type ; Outer shell for hot water from solar collector, PCM storage vessel in the middle of the tank and inside tube for hot water recovery. The heat storage tank has the dimension of 60 cm long and 34 cm outside diameter. Paraffin wax(m.p = 55.4C) and sodium acetate trihydrate(m.p = 58 C) were employed as the PCM this study. Experimental variables were inlet temperature and flow rate of the hot water for heat storage stage and cold water for heat recovery stage. Temperature profiles, heat transfer coefficient and the efficiency of heat storage$(Q/Q_{max})$ and heat recovery $(Q/Q_{max})$ were determined for the paraffin wax and inorganic salt respectively.

  • PDF

내부코일형 잠열 축열조에서의 열전달 특성 연구 (Heat transfer characteristics of Immersed Coil Type Latent Heat Storage Tank)

  • 이욱균;한귀영;강용혁
    • 한국태양에너지학회 논문집
    • /
    • 제21권1호
    • /
    • pp.83-91
    • /
    • 2001
  • The heat transfer experiment in a pilot scale latent heat storage tank as a solar energy storage system for the hot water supply was carried out. The latent heat storage tank was consisted of three parts; Outer shell for hot water from solar collector, PCM storage vessel in the middle of the tank and immersed coil in the PCM vessel for hot water recovery. The heat storage tank has the dimension of 115 cm in height and 32 cm outside diameter. Paraffin wax (m.p = 55.4C) and sodium acetate trihydrate (m.p = 58 C) were employed as the PCM this study. Experimental variables were inlet temperature and flow rate of the hot water for heat storage stage and cold water for heat recovery stage. Temperature profiles, heat transfer coefficient and the efficiency of heat storage $(Q/Q_{max})$ and heat recovery $(Q/Q_{max})$ were determined for the paraffin wax and inorganic salt respectively.

  • PDF

제올라이트를 이용한 화학축열에 대한 실험적 연구 (Experimental Study on Zeolite 13x for Thermochemical Heat Storage)

  • 하승호;박정훈;이수헌;김광호
    • 설비공학논문집
    • /
    • 제29권8호
    • /
    • pp.429-436
    • /
    • 2017
  • There are three main methods to store heat energy; sensible heat storage, latent heat storage, and thermochemical heat storage. Thermochemical heat storage has the highest storage density among the three methods, so this study focused on the thermochemical heat storage method. Experiments were conducted in this study with Zeolite 13x as thermochemical material in a large-scale reactor with 8 kg of Zeolite 13x. Experiments analyzed storage density of Zeolite 13x with respect to four different heating temperatures ($50^{\circ}C$, $100^{\circ}C$, $150^{\circ}C$, $200^{\circ}C$) in heat storage process. As a result, they showed 40~50 percent of storage efficiency in the experiment. Experiments also revealed that reactions between Zeolite 13x and water vapor were reversible and stable, but efficiency of the system was low, compared with sensible heat storage systems or latent heat storage systems.