• 제목/요약/키워드: Latent Heat

검색결과 647건 처리시간 0.024초

태양열저장(太陽熱貯藏)을 위한 평판형잠열축열장치(平板形潛熱蓄熱裝置)의 성능분석(性能分析) (Performance Analysis of a Panel Type Latent Heat Storage Equipment for Solar Thermal Storage)

  • 김영복;주은선;윤여두;라우정
    • Journal of Biosystems Engineering
    • /
    • 제16권3호
    • /
    • pp.290-297
    • /
    • 1991
  • For the efficient utilization of the solar thermal energy to overcome the time gap between to supply and demand, an efficient heat storage technique, especially high density-latent-heat storage system, is necessary. In this study, the performance of a panel type latent heat storage equipment during heat discharging process was analyzed theoretically and experimentally. In order to find out the performance of the system, computer simulation programs were developed by finite difference method. The governing equations were constructed by two dimensional heat conduction model with moving boundary. The results of the experimental and the theoretical analysis were reasonably well agreed. The efficiencies of the double pipe type and the panel type latent heat storage equipment were compared.

  • PDF

저온잠열축열을 위한 TMA-물계 포접화합물의 냉각특성 (TMA-Water Clathrate Compound of Cooling Characteristics for Low Temperature Latent Heat Storage)

  • 김창오;정현호;정낙규
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.296-301
    • /
    • 2009
  • The ice storage system uses water for low temperature latent heat storage. However, a refrigerator capacity is increased and COP is decreased due to supercooling of water in the course of phase change from solid to liquid. This study investigates the cooling characteristics of the TMA-water clathrate compound including TMA (Tri-methyl-amine, $(CH_3)_3N)$ of $20{\sim}25wt%$ as a low temperature latent heat storage material. The results showed that the phase change temperature and the specific heat is increased and the supercooling degree is decreased as the weight concentration of TMA increased. Especially, the clathrate compound containing TMA 25wt% has the average phase change temperature of $5.8^{\circ}C$, the supercooling degree of $8.0^{\circ}C$ and the specific heat of 3.499 kJ/kgK in the cooling process. This can lead to reduction of operation time of refrigerator in low temperature latent heat storage system and efficiency improvement of refrigerator COP and overall system. Therefore, energy saving and improvement of utilization efficiency are expected.

  • PDF

ANALYSIS OF WELD METAL STRUCTURE AND MECHANICAL BEHAVIOUR ENVISAGING PHASE CHANCE LATENT HEAT EFFECT

  • ;방한서;주성민;방희선
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2004년도 추계학술발표대회 개요집
    • /
    • pp.283-285
    • /
    • 2004
  • In this paper an important class of problems in welding which come under the category of phase change is considered, Solidification and melting are important process in welding field. Phase change problems are accompanied by either absorption or release of thermal energy i,e, heat transfer process. This is complicated by the release or absorption of the latent heat of fusion at the solid-liquid interface. In this study the liberation of latent heat is taken in to account using fixed grid method. The numerical simulation and the finite element codes for the heat transfer analysis including the latent heat term has been developed based on this fixed grid method.

  • PDF

잠열재를 이용한 통신 캐비넷용 Passive 냉각시스템 개발 (Development of Passive Cooling System for Communication Cabinet by Latent Heat Material.)

  • 정동열;박승상;백종현
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1385-1390
    • /
    • 2009
  • In this study the purpose is development of passive cooling system for telecommunication cabinet used by latent heat material. This cooling system is not required for electronic power. It was tested for the performance of the telecommunication combined latent heat material with $48^{\circ}C$ of phase changed temperature and heat pipe. At $45^{\circ}C$ of outside temperature, when heater power was 1,000 W and 1,500 W, the inside temperature of the cabinet was $55^{\circ}C$ and $62^{\circ}C$. This system was showed better performance than the other systems.

  • PDF

Thermal properties of latent heat storage microcapsule-water slurry

  • Mun, Soo-Beom
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권8호
    • /
    • pp.807-812
    • /
    • 2015
  • A microcapsule water slurry is a latent heat-storage material having a low melting point. In this study, the thermal properties of a microcapsule water slurry are measured. The physical properties of the test microcapsule water slurry, i.e., thermal conductivity, specific heat, latent heat, and density, are measured, and the results are discussed for the temperature region of solid and liquid phases of the dispersion material (paraffin). It is clarified that Eucken's equation can be applied to the estimation of the thermal conductivity of the microcapsule water slurry. Useful correlation equations of the thermal properties of the microcapsule water slurry are proposed in terms of the temperature and concentration ratio of the microcapsule water slurry constituents.

Modeling of vibration protection by shape memory alloy parts with an account of latent heat

  • Fedor S. Belyaev;Margarita E. Evard;Aleksandr E. Volkov;Maria S. Starodubova
    • Smart Structures and Systems
    • /
    • 제33권3호
    • /
    • pp.243-251
    • /
    • 2024
  • Modeling of vibrations of a rotating pendulum with working shape memory alloy rod has been performed in the frames of a microstructural model taking into account the latent heat release, absorption and the heat exchange during direct and reverse martensitic transformation. It has been shown that the influence of the latent heat, the rate of preliminary deviation of the pendulum from the equilibrium, the rate of heating and cooling can have a significant impact on the vibrations and damping characteristics of the system.

제주도 북부해역의 표면 열수지 해석 -1993년과 1994년 하계의 경우- (Surface Heat Budget of the Northern Sea of Cheju Island for June-August 1993 and 1994)

  • 김해동;양성기
    • 한국환경과학회지
    • /
    • 제4권3호
    • /
    • pp.197-206
    • /
    • 1995
  • Surface heat balance of the northern sea of Cheju Island for summer in 1993 and 1994 is analyzed using the observation data obtained by Marine Research Institute, Cheju National University. Each flux elements at the sea surface is derived from the marine meteorological reports with application of an aerodynamical bulk method for the turbulent heat fluxes, and empirical formulae for the long-wave radiation heat fluxes. The flux divergence of oceanic heat transport and the rate of heat storage in the ocean are estimated as residual. The features of the surface heat balance are mainly decided by the solar radiation flux and the latent heat flux for 199B. But the Bowen Ratios were large for 1993. This means that the sensible heat fluxes were nearly equal to the latent heat fluxes for 1993. In this period, mean flux divergence of oceanic heat transport is about 130 W/$m^2$.

  • PDF

변태잠열을 고려한 담금과정의 열전도 해석 (Heat Distribution Analysis of an End-Quenching Process Considering Latent Heat of Transformation)

    • 한국생산제조학회지
    • /
    • 제7권3호
    • /
    • pp.79-84
    • /
    • 1998
  • It is very difficult to analyze the transient temperature distribution during quenching of the steel because of coupled effects among temperature, structures and stresses. In this paper, using Inoue's equation of evolution and mixture rule, transient temperature distribution is calculated by the finite element method considering latent heat of transformation structure and temperature dependence of physical and mechanical prperties for the 0.45% carbon cylindrical steel bar with 40mm diameter and 20mm height during end-quenching.

  • PDF

영동대설 사례와 관련된 동해상의 현열속과 잠열속 분포 특성 (Characteristics of Sensible Heat and Latent Heat Fluxes over the East Sea Related with Yeongdong Heavy Snowfall Events)

  • 김지언;권태영;이방용
    • Ocean and Polar Research
    • /
    • 제27권3호
    • /
    • pp.237-250
    • /
    • 2005
  • To investigate the air mass modification related with Yeongdong Heavy snowfall events, we examined sensible and latent heat fluxes on the East Sea, the energy exchange between atmosphere and ocean in this study. Sensible and latent heats were calculated by a bulk aerodynamic method, in which NCEP/NCAR reanalysis data and NOAA/AVHRR weekly SST data with high resolution were used. Among winter precipitation events in the Yeongdong region, 19 heavy precipitation events $(1995{\sim}2001)$ were selected and classified into three types (mountain, cold-coastal, and warm types). Mountain-type precipitation shows highly positive anomalies of sensible and latent heats over the southwestern part of the East Set When separating them into the two components due to variability of wind and temperature/ specific Humidity, it is shown that the wind components are dominant. Cold-coastal-type precipitation also shows strong positive anomalies of sensible and latent heats over the northern part and over the central-northern part of the East Sea, respectively. It is shown that the sensible heat anomalies are caused mostly by the decrease of surface air temperature. So it can be explained that cold-coastal-type precipitation is closely related with the air mass modification due to cold air advection over warm ocean surface. But in warm-type precipitation, negative anomalies are found in the sensible and latent heat distributions. From this result, it may be postulated that warm-type precipitation is affected by the internal process of the atmosphere rather than the atmosphere-ocean interaction.

스트론튬계 잠열재를 사용한 저발열 콘크리트의 현장적용 평가 (Field Application of Low Heat Concrete Using Strontium Hydroxide Based Latent Heat Material)

  • 길배수;윤현도;정옥란
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권5호
    • /
    • pp.218-226
    • /
    • 2011
  • 본 연구에서는 스트론튬계 잠열재를 사용한 저발열 콘크리트를 레미콘 배처플랜트에서 시험생산한 후 생산된 콘크리트의 기초성능 및 모의부재에 의한 수화온도 특성을 평가하였으며, 그 결과 스트론튬계 잠열재를 사용한 저발열 콘크리트의 현장적용 가능성을 확인하였다. 이후 스트론튬계 잠열재를 사용한 콘크리트를 실제 교각 건설현장에 적용하였으며, 적용부재에 대한 수화열 해석 및 타설 콘크리트의 성능평가 결과 수화열 및 온도균열 저감효과가 우수한 것으로 나타나, 향후 대형 매스콘크리트의 수화열 및 온도균열 저감대책으로서 활용이 기대된다.