• Title/Summary/Keyword: Laser via

Search Result 345, Processing Time 0.03 seconds

Modeling the Growth of Bulk Single Crystals via High Performance Computing

  • Andrew Yeckel;Kwon, Yong-Il;Jeffrey J. Derby
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1997.06a
    • /
    • pp.115-120
    • /
    • 1997
  • We have developed new algorithms for solution of the three-dimensional, time-dependent Navier-Stokes equations that utilize massively parallel supercomputing implemented on the Connection Machine 5. Here, we apply these techniques to analyze he fluid flows that occur during the growth of the tow nonlinear optical crystals-potassium dihydrogen phosphate (KDP), which is producted in a novel rapid growth system under development by the Lawrence Livermore National Laboratory Laser Division, and Potassium titanyl phosphate(KTP), which is grown from a high-temperature aqueous solution.

  • PDF

Indoor Navigation of a Skid Steering Mobile Robot Via Friction Compensation and Map Matching (마찰 보상과 지도 정합에 의한 미끄럼 조향 이동로봇의 실내 주행)

  • So, Chang Ju;Lyou, Joon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.5
    • /
    • pp.468-472
    • /
    • 2013
  • This paper deals with the indoor localization problem for a SSMR (Skid Steering Mobile Robot) subjected to wheel-ground friction and with one LRF (Laser Range Finder). In order to compensate for some friction effect, a friction related coefficient is estimated by the recursive least square algorithm and appended to the maneuvering command. Also to reduce odometric information based localization errors, the lines are extracted with scan points of LRF and matched with the ones of the corresponding map built in advance. The present friction compensation and scan map matching schemes have been applied to a laboratory SSMR, and experimental results are given to validate the localization performance along an indoor corridor.

Utilization of functionalized magnetic nanoparticles for high throughput DNA separation

  • Jang, Jeong-Ho
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.11a
    • /
    • pp.12.2-12.2
    • /
    • 2009
  • The work describes anoptimized process to highly efficient and convenient preparation in highthroughput magnetic human DNA separation with chemically functionalizedsilica-coated magnetic nanoparticles. The effect of nanoparticle's size and the surface's hydrophilicity change were studied for magnetic DNA separation process, inwhich the optimum efficiency was explored via the function of the amino-groupnumbers, particle size, the amount of the nanoparticles used, and theconcentration of NaCl salt. The DNA adsorption yields were high in terms of theamount of triamino-functionalized nanoparticles used, and the average particlesize was 25 nm. The adsorption efficiency of aminofunctionalized nanoparticleswas the 4-5 times (80-100%) higher compared to silica-coated nanoparticles only(10-20%). DNA desorption efficiency showed an optimum level of over 0.7 M ofthe NaCl concentration. To elucidate the agglomeration of nanoparticles afterelectrostatic interaction, the Guinier plots were calculated from small angleX-ray diffractions in a comparison of the results of electron diffraction TEM,and confocal laser scanning microscopy. Additionally, the direct separation ofhuman genomic DNA was achieved from human saliva and whole blood with highefficiency.

  • PDF

Effect of Cationization Agent Concentration on Glycan Detection Using MALDI TOF-MS

  • Kim, Inyoung;Shin, Dongwon;Paek, Jihyun;Kim, Jeongkwon
    • Mass Spectrometry Letters
    • /
    • v.8 no.1
    • /
    • pp.14-17
    • /
    • 2017
  • The effect of cationization agent concentration on glycan detection via matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) was investigated using $Na^+$ ions in the form of NaCl as the cationization agent. NaCl solution concentrations ranging from 1 mM to 1 M were investigated. Glycans from ovalbumin were mixed with the cationization agent solution and the 2,5-dihydroxybenzoic acid (2,5-DHB) matrix solution in a volume ratio of 1:1:1. The resulting mixture was loaded onto the MALDI plate. Two MALDI-TOF MS instruments (Voyager DE-STR MALDI-TOF MS and Tinkerbell RT MALDI-TOF MS) were used for detection of glycans. The best detection, in terms of the number of identified glycans, the peak intensity, and the signal-to-noise (S/N) ratio, was obtained with NaCl concentrations of 0.01-0.1 M for both MALDI-TOF MS instruments.

Tunable Low Phase-noise Microwave Generation Utilizing an Optoelectronic Oscillator and a Fiber Bragg Grating

  • Zhuansun, Xiaobo;Chen, Yiwang;Zhang, Pin;Yin, Qin;Ni, Jiazheng;Dong, Xiaohua
    • Current Optics and Photonics
    • /
    • v.2 no.1
    • /
    • pp.96-100
    • /
    • 2018
  • A tunable low-phase-noise microwave generation structure that utilizes an optoelectronic oscillator (OEO) and a fiber Bragg grating (FBG) is proposed and experimentally demonstrated in this article. This structure has no particular requirement for the band width of the laser, and its tunability is realized through adjusting the central frequency of the tunable FBG. A detailed theoretical analysis is established and confirmed via an experiment. A high-purity microwave signal with a frequency tunable from 6 to 12 GHz is generated. The single-sideband phase noise of the generated signal at 10.2 GHz is -117.2 dBc/Hz, at a frequency offset of 10 kHz.

High-Resolution Fluorescence Near-Field Imaging of Individual Nanoparticles via the Tip-Induced Quenching Technique

  • Park, Won-Hwa;Kim, Zee-Hwan
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.12
    • /
    • pp.2195-2199
    • /
    • 2007
  • We demonstrate that high-resolution (~60 nm) near-field fluorescence images of fluorescent nanospheres can be obtained by utilizing the tip-induced fluorescence quenching process. A time-stamped photon counting (TSPC) technique employed enables us to efficiently measure the degree of fluorescence quenching caused by the dielectric or metallic atomic force microscopy tip. We find that the degree of quenching is not only determined by the tip-material but also by the local morphology of the tip. The fringe patterns around individual nanospheres observed are explained in terms of the interference between the excitation field that is directly induced by the laser source, and the scattered excitation field from the tip.

Recognition of Patterns and Marks on Monitor Glass Panel

  • Ahn, In-Mo;Kang, Dong-Joong;Lee, Kee-Sang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.99.2-99
    • /
    • 2002
  • Contents 1 In this paper a machine vision system for recognizing and classifying the patterns and marks engraved by die molding or laser marking on glass panel of computer monitor is suggested and evaluated experimentally. The vision system is equipped with a neural network based pattern classifier and searching process based on normalized grayscale correlation and adaptive binarization, which is applicable to the cases in which the segmentation of the pattern area from background using the ordinary blob coloring technique is quite difficult. Inspection process is accomplished via the way of NGC hypothesis and ANN verification. The proposed pattern recognition system is composed of three...

  • PDF

Development and Evaluation of Applications Using Micro-stereolithography Technology (마이크로 광 조형기술을 이용한 3차원 형태의 응용제품 제작 및 이의 평가)

  • 이인환;김동성;조동우;권태헌
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.233-236
    • /
    • 2003
  • The micro-stereolithography technology made it possible to fabricate a freeform 3D micro-structure. Using this technology, two kind of applications were fabricated and tested: micro-lens and micro-mixers. The focal length and f-number of the micro-lens were 5 mm and 2.5, respectively. The focusing ability of the micro-lens was verified by defocusing the He-Ne laser beam after passing the lens. Two mixers are Kenics micro-mixer and BEKM. BEKM is a modified Kenics micro-mixer by introducing barriers on the pipe walt periodically to enhance the mixing via the chaotic mechanism in the helical flow of Kenics micro-mixer. Experimental result shows good mixing performance of developed mixers. Especially, the BEKM shows better mixing performance then Kenics micro-mixer.

  • PDF

Measurement of Flow Field in a Domestic Boiler Circulation Pump by PIV (PIV에 의한 가정용보일러용 순환펌프의 내부 유동장 계측)

  • Im, Y.C.;Kim, J.H.;Choi, M.S.;Lee, Y.H.
    • Journal of Power System Engineering
    • /
    • v.3 no.2
    • /
    • pp.13-19
    • /
    • 1999
  • The purpose of the present experimental study is to apply multi-point simultaneous measurement by PIV(Particle Image Velocimetry) to high-speed flow region within a domestic boiler circulation pump. Two different kinds of flow rate($27{\ell}/min,\;19{\ell}/min$)are selected as experimental condition. A volute casing and Impeller made of transparent Polycarbonate were made for the easy access of the illumination laser via fiber optical line and cylinder lens assembly to the measuring region. A CCD camera is syncronized with AOM to acquire clear original particle images. Optimized cross correlation identification to obtain velocity vectors is implemented by direct calculation of correlation coefficients. The instantaneous and time-mean velocity distribution, velocity profile and kinetic energy are represented quantitatively at the full-scale region for the deeper understanding of the unsteady flow characteristics in a commercial circulation pump.

  • PDF

Laryngeal Verruca Vulgaris : A Case Report and Review of Literature (성대에서 진단된 심상성 사마귀 1례)

  • Han, Jae Sang;Hong, Soon Be;Lee, Philip;Park, Young Hak
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.27 no.2
    • /
    • pp.141-144
    • /
    • 2016
  • Verruca vulgaris of the larynx (VVL) is an extremely rare disease that can be easily misdiagnosed as papillary keratosis, squamous papilloma or verrucous carcinoma, which would have led to needless operation. We experienced a case of VVL in a 66-year-old man with 1-year history of progressive hoarseness. Whitish lesions in both vocal cords were observed by using indirect laryngoscopy and completely removed via microlaryngeal surgery with $CO_2$ laser.

  • PDF