• Title/Summary/Keyword: Laser ultrasonic

Search Result 248, Processing Time 0.023 seconds

Image Enhancement for Sub-Harmonic Phased Array by Removing Surface Wave Interference with Spatial Frequency Filter

  • Park, Choon-Su;Kim, Jun-Woo;Cho, Seung Hyun;Seo, Dae-Cheol
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.3
    • /
    • pp.211-219
    • /
    • 2014
  • Closed cracks are difficult to detect using conventional ultrasonic testing because most incident ultrasound passes completely through these cracks. Nonlinear ultrasound inspection using sub-harmonic frequencies a promising method for detecting closed cracks. To implement this method, a sub-harmonic phased array (PA) is proposed to visualize the length of closed cracks in solids. A sub-harmonic PA generally consists of a single transmitter and an array receiver, which detects sub-harmonic waves generated from closed cracks. The PA images are obtained using the total focusing method (TFM), which (with a transmitter and receiving array) employs a full matrix in the observation region to achieve fine image resolution. In particular, the receiving signals are measured using a laser Doppler vibrometer (LDV) to collect PA images for both fundamental and sub-harmonic frequencies. Oblique incidence, which is used to boost sub-harmonic generation, inevitably produces various surface waves that contaminate the signals measured in the receiving transducer. Surface wave interference often degrades PA images severely, and it becomes difficult to read the closed crack's position from the images. Various methods to prevent or eliminate this interference are possible. In particular, enhancing images with signal processing could be a highly cost-effective method. Because periodic patterns distributed in a PA image are the most frequent interference induced by surface waves, spatial frequency filtering is applicable for removing these waves. Experiments clearly demonstrate that the spatial frequency filter improves PA images.

In-vitro and In-vivo Biocompatibility Evaluation of Silica Based Bio-active Glass Prepared by Hydrothermal Method

  • Sarkar, Swapan Kumar;Nguyen, Phuong Thi;Lee, Byong-Taek
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.53.1-53.1
    • /
    • 2011
  • Bioactive glass powders were synthesized by hydrothermal chemical route by the use of ultrasonic energy irradiation. We used sodalime, calcium nitrate tetra hydrate and di ammonium hydrogen phosphate as the precursor material to synthesize $SiO_2$ rich bio-active glass materials. The $SiO_2$ content was varied in the precursor mixture to 60, 52 and 45 mole%. Dense compacts were obtained by microwave sintering at $1,100^{\circ}C$. Mechanical properties were characterized for the fabricated dense bioactive glasses and were found to be comparable with conventional CaO-$SiO_2$-$Na_2O$-$P_2O_5$ bioactive glass. Detailed biocompatibility evaluation of the glass composition was investigated by in-vitro culture of MG-63 cell and mesenchyme stem cell. Cell adhesion behavior was investigated for both of the cell by one cell morphology for 30, 60 and 90 minutes. Cell proliferation behavior was investigated by culturing both of the cells for 1, 3 and 7 days and was found to be excellent. Both SEM and confocal laser scanning microscopy were used for the investigation. Western blot analysis was performed to evaluate the bimolecular level interaction and extent and rate of specific protein expression. The ability to form biological apatite in physiological condition was observed with simulated body fluid (SBF). In-vivo bone formation behavior was investigated after implanting the materials inside rabbit femur for 1 and 3 month. The bone formation behavior was excellent in all the bioglass compositions, specially the composition with 60% $SiO_2$ content showed most promising trend.

  • PDF

New calibration apparatus for a precise barometer (초정밀 기압계 교정을 위한 새로운 압력계 교정장치 개발)

  • 우삼용;이용재;최인묵;김부식;최종운
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.3
    • /
    • pp.157-161
    • /
    • 2003
  • Nowadays there are increasing demands for more accurate measurement of atmospheric pressure according to the development of environmental industries. One of the most important pressure gauges for satisfying these demands is a quartz resonance barometer. In order to calibrate such an accurate barometer, laser/ultrasonic mercury manometers have been used. However, complexity and cost of mercury manometers made it out of use gradually. As a substitute, a gas-operated pressure balance is used for calibration of precise barometers. In such a case, commercially available pressure balances cannot be entirely suitable because consequent exposure of the piston, cylinder and masses to the atmosphere causes the problem of contamination. In this paper a device for changing the masses in situ without breaking the vacuum is described. This device made it possible to add or remove weights in the absolute mode, thereby greatly reducing the time between observations. At the same time, we investigated the characteristics of a commercial precise barometer using this new apparatus.

Visualization and Flowfield Measurements of the Vortical Flow over a Double-Delta Wing

  • Sohn, Myong-Hwan;Jang, Young-IL
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.4 no.1
    • /
    • pp.63-74
    • /
    • 2003
  • The vortical flow of a 65-deg flat plate delta wing with a leading edge extension(LEX) was examined through off-surface visualization, 5-hole probe and hot-film measurements. The off-surface flow visualization technique used micro water droplets generated by a home-style ultrasonic humidifier and a laser beam sheet. The angles of attack ranged from 10 to 30 degrees, and the sideslip angles ranged from 0 to -15 degrees. The Reynolds number was $1.82{\times}10^5$ for the flow visualization, and $1.76{\times}10^6$ for the 5-hole probe and hot-film measurements. The comparison of the visualization photos and the flow field measurement showed that the two results were in a good agreement for the relative position and the structure of the wing and LEX vortices, even though the flow Reynolds numbers of the two results were much different. The wing vortex and the LEX vortex coil each other while maintaining a comparable strength and identity at zero sideslip. Neither a looping of the wing vortex around the strake vortex, nor the lopsided coiling of the stronger strake and the weaker wing vortices was observed. At non-zero sideslip, the downward movement of the LEX vortex when going downstream was enhanced on the windward side, and the downward and inboard movement of the LEX vortex when going downstream was suppressed on the leeward side. The counterclockwise coiling of the wing and LEX vortices was decreased significantly on the leeward side.

Freehang 방법을 이용한 DLC 필름의 탄성 특성 평가

  • 정진원;이광렬;은광용;고대홍
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.128-128
    • /
    • 2000
  • 박막의 탄성 특성을 평가하는 방법으로 nano-indentation, Brillouin light scattering measurement, ultrasonic surface wave measurement, bulge test, vibration membrane method 등 여러 가지가 제시되어 왔다. 이러한 방법들은 필름의 두께가 일정 두께 이상이 되어야 정확한 측정이 가능한 방법으로 매우 얇은 박막에서도 탄성특성을 평가할 수 있는 freehang, bridge 방법이 제시되었으며, 이 방법은 간단한 식각 공정을 통해 매우 얇은 박막에도 적용시킬 수 있다는 장점을 가지고 있다. 본 연구에서는 아주 얇은 박막에서도 탄성특성을 평가할 수 있는 freehang 방법을 이용하여 순수한 Diamond-like carbon (DLC) 필름과 Sidl 첨가된 DLC 필름의 탄성 특성을 평가하고자 한다. 실험에서 사용한 필름은 rf-PACVD 장비를 이용하여 증착하였다. 이때 전극과 플라즈마 사이의 바이어스 음전압은 -400 Vb로 합성압력은 10mTorr로 고정하였다. 사용한 반응 가스는 벤젠(C6H6), 그리고 벤젠과 희석된 실렌(SiH4 : H2 = 10 : 90)이며, 희석된 실렌의 첨가량을 조절하여 필름 내에 일정량의 Si을 함유시켰다. 각각의 조건에서 증착시간을 조절하여 필름의 두께를 변화시켰으며, KOH(5.6mol) 용액을 이용하여 습식 식각을 함으로써 freehang을 제작하였다. 이때 식각액에 의한 DLC 필름의 손상은 관찰되지 않았다. 필름의 잔류 응력을 측정하기 위해 200$\pm$10 혹은 100$\pm$5$\mu\textrm{m}$ 두께의 얇은 (100) Si wafer를 5$\times$50 mm2의 strip 형태로 절단하여 사용하였다. 필름의 압축 잔류 응력에 의해 발생한 필름/기판 복합체의 곡률은 laser 반사법과 $\alpha$-step profiler를 이용하여 측정하였으며, 이 결과를 Brenner 등에 유도된 식을 이용하여 잔류 응력을 계산하였다. 또한 제작된 frddhang은 광학 현미경과 전자주사현미경에 의해 관찰되었다. 이렇게 제작된 freehang을 이용하여 필름이 기판에 부착되기 위해 필요한 변형률을 측정하고, 독립적으로 측정된 필름의 잔류 응력을 박막의 응력-변형률 관계식에 적용하여 biaxial elastic modulus, E/(1-v)를 구할 수 있었다. 측정 결과 필름의 잔류 응력과 biaxial elastic modulus는 필름의 두께가 감소함에 따라 감소하는 경향을 나타냈으며, 같은 두께의 필름인 경우, 식각 깊이에 따른 biaxial elastic modulus 의 변화를 통해 최적의 식각 깊이를 알 수 있었다.

  • PDF

Tribological Performance of Ni-Cr Composite Coating Sprayed onto AISI 4340 (SNCM439) Steel by High Velocity Oxygen Fuel

  • Umarov, Rakhmatjon;Pyun, Young-Sik;Amanov, Auezhan
    • Tribology and Lubricants
    • /
    • v.34 no.6
    • /
    • pp.217-225
    • /
    • 2018
  • In this study, we spray a Ni-Cr composite powder onto AISI 4340 steel using the high velocity oxygen fuel method. We subsequently subject the Ni-Cr coating (as-sprayed) to ultrasonic nanocrystal surface modification (UNSM) process to improve the tribological performance. This study aims at increasing the wear resistance and durability of the Ni-Cr coating by altering the surface integrity and microstructure via the UNSM process. The UNSM process reduces the surface roughness of the as-sprayed coating by about 64%, which is explained by observing the elimination of high peaks and valleys and filling up micro-pores. Furthermore, a change in the microstructure of the coating due to continuous high-frequency strikes to the surface by a tip can lead to an increase in hardness from about 48 to 60 HRC. Furthermore, we investigate the characterization of the friction and wear behavior of Ni-Cr coating by a ball-on-disc tribometer in the dry conditions. We determine that after the UNSM process, there is a significant reduction in the friction coefficient of the as-sprayed coating from approximately 1.1 to 0.75. This is owing to the increased hardness and smoothed surface roughness. In addition, we investigate the surface morphology and wear track of the coatings before and after the UNSM process using a scanning electron microscope, energy dispersive spectrometer, and three-dimensional laser scanning microscope. We observe that the wear track of the Ni-Cr coating after the UNSM process is lower than that of the as-sprayed one. Thus, we confirm that the UNSM process has a significant influence on the improvement of the tribological performance of the Ni-Cr composite coating.

Dental Hygienist's Job Perception of Some Prospective Graduates (일부 치위생학과 졸업예정자의 치과위생사 직무에 대한 인식)

  • Hwang, Soo-Jeong;Bae, Soo-Myoung;Yu, Ji-Su;Han, Yang-Keum
    • Journal of Korean Dental Hygiene Science
    • /
    • v.3 no.1
    • /
    • pp.25-36
    • /
    • 2020
  • Introduction: The legal duties of Korean dental hygienists are different from the actual tasks. These factors cause dental hygienists to experience work stress. Therefore, it is necessary to investigate what tasks the dental hygienist expects to perform. Methods: This study examined the perception of dental hygienists' work on 158 prospective graduates of the 3rd-year and 4th-year course of dental hygiene. The questionnaire about the dental hygienist's duties was prepared based on the job description of dental hygienists by the Korea Health Personnel Licensing Examination Institute. Results: More than 84% said that all of the work in the second job description was possible as dental hygienists. subjects responded that the following items were not dental hygienists' duties: treatment plan based on medical history and dental history, treatment plan based on an intraoral and extraoral examination, treatment plan based on the results of teeth and periodontal examination, analysis of oral health data in community, planning of oral health promotion in community, planing of water fluoridation, reading of radiography, root planing, physical treatment on head and neck, using an ultrasonic device on head and neck, dealing with laser devices, making a temporary crown, suture and stitch-out, and intramuscular injection. Conclusions: Most graduates of dental hygiene departments have recognized that the tasks described in the second job description are dental hygienists' work; therefore, it is necessary to improve the gap between expected work and legal work.

Decontamination methods to restore the biocompatibility of contaminated titanium surfaces

  • Jin, Seong-Ho;Lee, Eun-Mi;Park, Jun-Beom;Kim, Kack-Kyun;Ko, Youngkyung
    • Journal of Periodontal and Implant Science
    • /
    • v.49 no.3
    • /
    • pp.193-204
    • /
    • 2019
  • Purpose: The reaction of cells to a titanium implant depends on the surface characteristics of the implant which are affected by decontamination. The aim of this study was to evaluate the cytocompatibility of titanium disks treated with various decontamination methods, using salivary bacterial contamination with dental pellicle formation as an in vitro model. Methods: Sand-blasted and acid-etched (SA) titanium disks were used. Three control groups (pristine SA disks [SA group]; salivary pellicle-coated SA disks [pellicle group]; and biofilm-coated, untreated SA disks [NT group]) were not subjected to any decontamination treatments. Decontamination of the biofilm-coated disks was performed by 14 methods, including ultrasonic instruments, rotating instruments, an air-powder abrasive system, a laser, and chemical agents. MG63 cells were cultured in the presence of the treated disks. Cell proliferation assays were performed on days 2 and 5 of cell culture, and cell morphology was analyzed by immunofluorescence and scanning electron microscopy (SEM). A vascular endothelial growth factor (VEGF) assay was performed on day 5 of culture. Results: The cell proliferation assay revealed that all decontaminated disks, except for the 2 groups treated using a plastic tip, showed significantly less cell proliferation than the SA group. The immunofluorescence and SEM analyses revealed that most groups showed comparable cell density, with the exception of the NT group, in which the cell density was lower and bacterial residue was observed. Furthermore, the cells grown with tetracycline-treated titanium disks showed significantly lower VEGF production than those in the SA group. Conclusions: None of the decontamination methods resulted in cytocompatibility similar to that of pristine SA titanium. However, many methods caused improvement in the biocompatibility of the titanium disks in comparison with the biofilm-coated, untreated titanium disks. This suggests that decontamination is indispensable for the treatment of peri-implantitis, even if the original biocompatibility cannot be restored.

A Study on the Effect of UNSM Treatment on the Mechanical and Tribological Properties of STS 316L Printed by Selective Laser Melting (SLM 방식으로 출력된 STS 316L의 기계적 및 마찰·마모 특성에 미치는 UNSM처리 후 영향에 관한 연구)

  • Ro, J.S.;Sanseong, C.H.;Umarov, R.;Pyun, Y.S.;Amanov, A.
    • Tribology and Lubricants
    • /
    • v.34 no.6
    • /
    • pp.270-278
    • /
    • 2018
  • STS 316L prepared by additive manufacturing (AM) exhibits deterioration of mechanical properties and wear resistance due to the presence of defects such as black-of-fusion defects, internal porosity, residual stress, and anisotropy. In addition, high surface roughness (integrity) of AM products remains an issue. This study aimed to apply ultrasonic nanocrystal surface modification (UNSM) technology to STS 316L prepared by AM to increase the surface hardness, to reduce the surface roughness, and to improve the friction and wear behavior to the level achieved by bulk material manufactured using traditional processes. Herein, the as-received and polished specimens were treated by UNSM technology and their resulting properties were compared and discussed. The results showed that UNSM technology increased the surface hardness and reduced the surface roughness of the as-received and polished specimens. These results can be attributed to grain size refinement and pore elimination from the surface. Moreover, the friction of the as-received and polished specimens after UNSM technology was lower compared to those of the as-received and polished specimens, but no significant differences in wear resistance were found.

A Study of Quantitative Snow Water Equivalent (SWE) Estimation by Comparing the Snow Measurement Data (적설 관측자료 비교를 통한 정량적 SWE 산출에 관한 연구)

  • Ro, Yonghun;Chang, Ki-Ho;Cha, Joo-Wan;Chung, Gunhui;Choi, Jiwon;Ha, Jong-Chul
    • Atmosphere
    • /
    • v.29 no.3
    • /
    • pp.269-282
    • /
    • 2019
  • While it is important to obtain the accurate information on snowfall data due to the increase in damage caused by the heavy snowfall in the winter season, it is not easy to observe the snowfall quantitatively. Recently, snow measurements using a weighing precipitation gauge have been carried out, but there is a problem that high snowfall intensity results in low accuracy. Also, the observed snowfall data are sensitive depending on wind speed, temperature, and humidity. In this study, a new process of quality control for snow water equivalent (SWE) data of the weighing precipitation gauge were proposed to cover the low accuracy of snow data and maximize the data utilization. Snowfall data (SWE) observed by Pluvio, Parsivel, snow-depth meter using laser or ultrasonic, and rainfall gauge in Cloud Physics Observation Site (CPOS) were compared and analyzed. Applying the QC algorithm including the use of number of hydrometeor particles as reference, the increased SWE per the unit time was determined and the data noise was removed and marked by flag. The SWE data converted by the number concentration of hydrometeor particles are tested as a method to restore the QC-removed data, and show good agreement with those of the weighing precipitation gauge, though requiring more case studies. The three events data for heavy snowfall disaster in Pyeongchang area was analyzed. The SWE data with improved quality was showed a good correlation with the eye-measured data ($R^2$ > 0.73).