• Title/Summary/Keyword: Laser needle

Search Result 62, Processing Time 0.02 seconds

The Preparation and Magnetic Properties in Ba-ferrite Film on the A12O3 Substrate (A12O3을 하지층으로 하는 Ba-ferrite 박막의 제조 및 자기적 특성에 관한 연구)

  • Sur, Jung-Chul;Park, Chul-Jin;Choi, Jung-Wan
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.2
    • /
    • pp.125-129
    • /
    • 2005
  • Ba-Ferrite thin films were prepared on $A1_2O_3$ substrate by a pulsed laser deposition system and characterized by SEM, $M\ddot{o}$ssbauer spectroscopy and VSM. The appropriate conditions of pulsation in Ba-ferrite was the oxygen pressure of 0.1 Torr at a substrate temperature of $400^{\circ}C$ and the thickness was variable with the deposition time. Ba-ferrite crystals had the forms of hexagonal plate in the 5 minute deposited film and the needle grains coexisted with the increasing film thickness. $M\ddot{o}ssbauer$ spectroscopy assured that the direction of atomic spin in Fe ion tends to normal to the substrate in the hexagonal plate. The VSM curves have the two types hysteresis of hexagonal and needle phase.

The effects of manual acupuncture, invasive laser acupuncture and laser skin irradiation at Liver Seunggyeok(肝勝格) on the repair of D-galN-induced Liver Injury in Rats (간승격(肝勝格) 혈위(穴位)에 시술된 침자(鍼刺)와 침습(侵襲) 및 비침습(非侵襲) 레이저침요법(鍼療法)이 간손상(肝損傷) 회복에 미치는 영향)

  • Shin, Hyung-Jin;Kim, Young-Sun;Youn, Dae-Hwan;Lee, Suk-Hee;Oh, Gwang-Hwan;Jeong, Sung-Ho;Na, Chang-Su
    • Korean Journal of Acupuncture
    • /
    • v.27 no.1
    • /
    • pp.49-62
    • /
    • 2010
  • Objective: This study was performed to investigate the effect of manual acupuncture, invasive laser acupuncture and laser skin irradiation at LU8, LR4, HT8 and LR2(Liver Seunggyeok) on D-galN-induced liver injury in rats. Method: Liver injury was induced with D-galN. The experimental rats were divided four groups(Control group, EXP-1, EXP-2, EXP-3). In the Control group, liver injury-induced and not treated. EXP-1 group was liver injury-induced and carried out manual acupuncture with Young-Su(against the meridian course and following the course of the meridian) & Won-Bang(by twisting and rotating the needle) acupuncture method at Liver Seunggyeok. EXP-2 group was liver injury-induced and carried out invasive laser acupuncture at Liver Seunggyeok. EXP-3 group was liver injury-induced and carried out laser skin irradiation at Liver Seunggyeok. Result: In the change of body weight(in 1 week), EXP-1, EXP-2 and EXP-3 groups were significantly increased as compared with control group. In the change AST & ALT, EXP-1 and EXP-2 groups were significantly decreased as compared with control group. In the change of SOD, EXP-1, EXP-2 and EXP-3 groups were significantly increased as compared with control group. In the change of WBC, EXP-2 group was significantly increased as compared with control group. Conclusion: Manual acupuncture, invasive laser acupuncture and laser skin irradiation at Liver Seunggyeok had hepatotherapeutic effect on the treatment of hepatocytotoxity. Invasive laser acupuncture was as effective as manual acupuncture on the treatment of hepatocytotocity.

An experimental study on the characteristic times of viscoelastic fluids by falling ball viscometer (낙구식 점도계를 이용한 점탄성 유체의 특성시간에 관한 실험적 연구)

  • 전찬열;유상신
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.1
    • /
    • pp.241-250
    • /
    • 1990
  • Characteristic relaxation time and characteristic diffusion time of viscoelastic fluids are determined experimentally by measuring the zero-shear-rate viscosity by falling ball viscometer and the infinite-shear-rate viscosity by capillary tube viscometer. Fluids used in experiments are aqueous solutions of polyacrylamide Separan AP-273 and the polymer concentrations range from 300 to 2000 wppm. A newly designed laser beam and timer system is employed to overcome the difficulty in measuring terminal velocities of the low concentration solutions. Ball removal device is prepared to remove the dropped ball from the bottom of cylinder without disturbing the testing fluid. In order to measure the zero-shear-rate viscosity, densities of hollow aluminium balls are adjusted very close to the densities of testing fluids. Characteristic diffusion time, which is ball viscometer. However, terminal velocity of a needle by falling ball viscometer is not affected by the time interval of dropping needles and characteristic diffusion time is not measured with a dropping needle. Powell-Eyring model predicts the highest values of the characteristic relaxation times among models used for heat transfer experimental works for a given polymer solution. As degradation of a polymer solution continues, the zero-shear-rate viscosity decreases more seriously than the infinite-shear-rate viscosity. Characteristic relaxation times of polymer solutions decreases as degradation continues.

Detection of laser doppler blood flow signal from human teeth

  • Ikawa, M.;Iiyama, M.;Shimauchi, H.
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.546.1-546
    • /
    • 2003
  • Laser doppler flowmeter (LDF) has been applied to the measurement of pulpal blood flow (PBF) in human teeth. As far as we searched, the detection area of the pulp in the blood flow measurement has not been clarified, yet. Therefore, the purpose of this study was to obtain information of the detection area in PBF measurement using LDF. The experiments were performed on the artificial blood circulation in extracted human upper central incisors. The apical portions of examined teeth (n=6) were severed and root canals were enlarged from the apical end to the 2mm incisal to the level of enamel-cement junction. An individual resin cap of each tooth was prepared and a hole was drilled 2mm incisal to enamel-cement junction of the labial side of the cap. The measurement probe of LDF (MBF3D, Moor Instrument, UK) was plugged into the hole of the cap. Heparinized human peripheral blood, which was in advance collected and diluted 3 times with physiological saline, was pumped through the apical foramen of the teeth via a silicone tube and a disposable needle (o.d. 0.7mm) and blood flow signals were monitored. The flux signal significantly increased with the enlargement of the root canal to incisal direction (p<0.01, Friedman analysis). The result indicates that the performance of LDF in PBF with human teeth is limited.

  • PDF

The Systematic Review on Clinical Studies of Traditional Korean Medicine Treatment for Obesity in Menopausal Women (폐경 여성의 비만에 응용되는 한방치료에 대한 문헌 고찰)

  • Nam, Eun Young
    • Journal of Korean Medicine for Obesity Research
    • /
    • v.19 no.1
    • /
    • pp.56-67
    • /
    • 2019
  • Objectives: The purpose of this study is to review clinical studies of herb medicine and acupuncture treatment on obesity in menopausal women. Methods: Key words "Obesity", "Menopause", "Herb medicine", "Acupuncture", "Moxibustion", "Catgut embedding" were searched on 9 database systems (PubMed Central, Cochrane Controlled Register of Trials, Embase, China Academic Journals, Korean Traditional Knowledge Portal, Oriental Medicine Advanced Searching Integrated System, Korean Studies Information Service System, National Digital Science Library, DBpia) on April 30th 2019. Results: 1 case report and 17 clinical trials were collected in accordance with the selection and exclusion criteria. Among the 17 trials, 6 were randomized controlled trials, 1 was controlled clinical trial, and 10 were single-arm trials. The types of intervention were herb medicine, electroacupuncture, acupuncture, auricular acupuncture, warm needle acupuncture, moxibustion, laser acupuncture, and catgut embedding. The study design, study results and method of intervention were analyzed. Conclusions: 1 case report described the effectiveness of pharmacopuncture, 4 trials described the effectiveness of herbal medicine, 2 of electroacupuncture, 1 of laser acupuncture, and 2 of catgut embedding. Among the 17 trials, 2 studies showed that herbal medicine treatment was more effective than no treatment or selective serotonin reuptake inhibitors, and 1 study showed that electroacupuncture was more effective than hormone therapy. All of 18 selected studies reported the effectiveness of weight reduction and abdominal obesity reduction after the traditional Korean medicine treatment for obesity in menopausal women.

Comparison of meridians electric response property for laser and acupuncture stimulation (레이저자극과 수기자극에 대한 경락전기반응 특성비교)

  • Lee, Yong-Heum;Ryu, Yeon-Hang;Jung, Byoung-Jo;Shin, Tae-Min
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.12
    • /
    • pp.2335-2342
    • /
    • 2007
  • Laser stimulation has been widely studied and used in clinic. However, electrical response by laser stimulation on meridians has not been investigated. In this study, we compared electric potential of laser and acupuncture stimulation on meridians. We measured electric potential variation at acupoints(Samgan(LI3) and Hapgok(LI4)) on Large Intestine Meridian. In laser stimulation results, average peak electric potential is very low($7.53{\pm}3.44{\mu}V$) for before and after stimulation. However, acupuncture stimulation was performed in ground connection condition and resulted in huge variation of average peak electric potential($2.65{\pm}1.53mV$). That is, the intensity and pattern of electric potential were dependent on the ground connection condition and individual. Also, the electric potential pattern was very similar to the pattern of electric charge and discharge of capacitor. The acupuncture stimulation using a insulating needle resulted in lower average peak electric potential variation($0.25{\pm}0.16mV$) than that of acupuncture stimulation. It might present little electrical response of acupuncture stimulation using insulating needles. In point of electrical response, the laser stimulation was determined to be no acupuncture effect at meridian. Acupuncture stimulation seems to be most effective method to induce electrical response at meridians. The procedure and effect of acupuncture might be considered as energy consensus phenomenon by transportation of bio-ion charge between a practitioner and patient.

Seam Characteristics of Breathable Waterproof Fabrics with Various Finishing Methods

  • Jeong, Won-Young;An, Seung-Kook
    • Fibers and Polymers
    • /
    • v.4 no.2
    • /
    • pp.71-76
    • /
    • 2003
  • We evaluated the seam characteristics with finishing, seaming and sealing processes and seam Puckering behavior of the breathable waterproof fabrics with laser scan. There were differences in 99% significant level between the seamed fabric and the sealed fabric. Seam breakage was initiated with the breakage of sewing thread, so the seam strength after seaming was almost uniform. The sewn seam strength and elongation increased with sealing process in all finishing methods. Pucker grade of laminating type was generally much higher than that of the coating type. We confirmed that wave length and amplitude have more important meaning than the number of weave in the breathable waterproof fabrics. The puckering in breathable waterproof fabrics is mainly occurred by inherent and feeding pucker. The former if due to the insertion of sewing thread and the littler is caused by differential feeding when two pieces of fabric are fed into the gap between a press foot and needle plate.

Eastern and Western Treatments for Improving Wrinkles and Treatment of Fine Wrinkles with Subcision (주름 개선을 위한 한.양방의 치료 동향 및 절개침을 사용한 잔주름 치료법 소개)

  • Cho, Seung-Pil;Lee, Kwang-Ho
    • Journal of Acupuncture Research
    • /
    • v.29 no.2
    • /
    • pp.29-36
    • /
    • 2012
  • The purpose of this article is to review all the wrinkle treatments reported so far, and to introduce a method of dermal subcision, especially localized fine wrinkles. In order to remove wrinkles, laser, ulthera and drug therapy are commonly used in western medicine while Miso facial rejuvenation acupuncture, $Jung-An$ acupuncture and needle-embedding therapy are used in oriental medicine. However, as researches on fine wrinkles have been insufficiently conducted until now. Dermal subcision stated in this study is considered to be a safe and effective way to ameliorate fine linear-shaped wrinkles around or below eyes and mouth by increasing the circulation of qi and blood. also, reproducing dermal layer. More and further related cases and researches are expected in the future.

A possible optical measuring technique for corona discharge by use of Pockets sensor (광계측 시스템을 이용한 코로나 방전 검출)

  • Kang, Won-Jong;Ma, Ji-Hoon;Chang, Yong-Moo;Koo, Ja-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1561-1563
    • /
    • 2001
  • In this paper, an novel optical measuring system based on the electro-optic effect has been proposed and realized using Pockels cell with a view to detecting partial discharge taking place at the needle plane electrode. This system has the following advantages ; nonmetallic probe sensor, immune to external EMI noise and broad band response of the Pockels cell from DC to GHz. And also it is constructed by He-Ne laser, optical fiber, $LiNbO_3$ Pockels cell, photo detector, grin lens, oscilloscope and PC. The characteristics of the developed prototype sensor are investigated under AC and corona discharges.

  • PDF

A possible application of the nonuniform electric field measurement using Pockets effect (포켈스 효과를 이용한 불평등 전계 측정)

  • Kang, W.J.;Lim, Y.S.;Choi, J.O.;Chang, Y.M.;Koo, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11c
    • /
    • pp.513-515
    • /
    • 2000
  • In this paper, new Partial Discharge (PD) detection technique using Pockels-cell was proposed. For this purpose, PD was generated from needle-plane electrode in air and detected by optical measuring system using Pockets cell, based on Mach-Zehnder interferometer, consisting of He-Ne laser, single mode optical fiber, 50/50 beam splitter and photo detector. We show the characteristic of the proto-type sensor for the corona discharge.

  • PDF