• 제목/요약/키워드: Laser lens

검색결과 376건 처리시간 0.023초

20W급 AlGaAs 레이저 다이오드 어레이의 제작 (Fabrication of a AlGaAs high power (~20W) laser diode array)

  • 박병훈;손낙진;배정훈;권오대
    • 전자공학회논문지D
    • /
    • 제34D권11호
    • /
    • pp.20-24
    • /
    • 1997
  • We have successfully fabricated high power (~20W) laser diode array, which are useful for pumping Nd:YAG lasers. The laser diode aray has 20 100.mu.m-wide cahnnels of which space was adjusted to 350.mu.m to improve thermal characteristics. And channel width is 100.mu.m. For an uncoated LD array, the output power of 15.66W has been obtained at 41A under quasi-CW operation, which results in about 0.42W/A slope efficiency. After aR(5%) and HR (95%) coatings on both facets, the output power was improved up to 21.18W at 40A under the same operation as above and the slope efficiency was 0.795W/A. On the other hand, by using a near field measurement system consisting of objective lens, eyepiece, CCD camera and image processing board, the typical near field patten of 1*20 LD array was observed.

  • PDF

레이저 진동 측정기를 이용한 초음파 이송 시스템의 동작특성에 관한 연구 (A Study on the Motion Characteristics of the Ultrasonic Transport System using Laser Scanning Vibrometer)

  • 정상화;신병수;이경형
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2003년도 추계학술대회
    • /
    • pp.155-158
    • /
    • 2003
  • In the semiconductor and the optical industry a new transport system which can replace the conventional sliding system is required. These systems are driven by magnetic field and conveyer belt. The magnetic field damages semiconductor and contact force scratches the optical lens. The ultrasonic wave driven system can solve these problem. In this paper, the vibration behavior of flexural beam in the ultrasonic transport system is verified using Laser Scanning Vibrometer. The experiments for verifying vibration are performed in three conditions such as in the maximum transport speed, in the zero speed, and in the change of transport direction.

  • PDF

CCD/LSB 방식의 형상측정시스템의 정밀도 향상 방법 (Precision enhancement for a CCD/LSB type shape measuring system)

  • 유주상;정규원
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2001년도 춘계학술대회 논문집(한국공작기계학회)
    • /
    • pp.137-142
    • /
    • 2001
  • Since recent production system becomes that of the small quantity, large volume with high quality production, accurate and high speed inspection system is required. In such situation, noncontact 3D measurement system which utilized CCD cameras is useful technique in terms of system cost, speed of data acquisition, measuring accuracy and application. However, it has low accuracy compared with contact 3D measurement system because of the camera distortion, non uniformity of laser distribution and so on. For those reasons, in this paper precision enhancement method is studied considering radial camera distortion, and laser distribution. A distortion correction method is applied even to the standard lens. The laser slit beam trajectory is determined by 3 method: based of the Gaussian function signal approximation, the median method, the center of gravity method and the peak point of the Gaussian function method.

  • PDF

망막 영상 조절 장치에 관한 연구 (A Study of the Retina Image Controllability using a Sledge)

  • 이숙희;이영춘;양연식
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.273-276
    • /
    • 1997
  • Seeing is an intelligent act. Retina is the most important part among the components of eye which is comprised of iris, pupil, lens, optic disk, and so forth. Because retina acts like a photo receiver to detect light from every object, if damaged, animals have a severe problem to live along with themselves and sometimes they lose their sight. In the ophthalmology, doctors use special instrument to see exact retina image of object and operate the surgery by rotating focus control knob. In this study, a basic test is done to achieve the auto focus control instrument. Specially made sledge and attenuator are installed on the optic bed to change the distance and laser power between the first reflective mirror and the second one. Control panel which is compiled by Visual C t t to control stepping motors ,laser power and photodiode are implemented with ADA-board.

  • PDF

혈류 시뮬레이터와 LD의 자기혼합효과를 이용한 혈류계 프로브의 구현 (Implementation of a blood flow simulator and a blood flowmeter probe using self-mixing effect of the laser diode)

  • 김종원;고한우
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.76-77
    • /
    • 1998
  • In this paper, the authors have implemented a blood flow simulator and a blood flowmeter probe using self-mixing effect of the laser diode. The purpose of the blood simulator is to simulate microvascular blood flow in tissue. It consists of melinex film (thickness = $125{\mu}m$) which has similar optical characteristics to epidermis and porous polyethylene filter (Vyon, porosity 35%, mean pore size $50{\mu}m$, thickness=1 mm) which has similar optical characteristics to dermis. The blood flowmeter probe consists of laser diode(5 mW, 780 nm wavelength), CD lens(focal lenght 12 mm), current-to-voltage converter, highpass filter, and preamplifier. It doesn't need optical fiber, therefore, implementation of the probe is simpler than conventional probe using optical fiber.

  • PDF

Finishing 용 전자빔 집속 장치의 성능 실험 (Performance Experiment of Electron Beam Convergence Instrument)

  • 임선종
    • 한국레이저가공학회지
    • /
    • 제18권3호
    • /
    • pp.6-8
    • /
    • 2015
  • Finishing process includes deburring, polishing and edge radiusing. It improves the surface profile of specimen and eliminates the alien substance on surface. Deburring is the elimination process for debris of edges. Polishing lubricates surfaces by rubbing or chemical treatment. There are two types for electron finishing. The one is using pulse beam. The other is using the convergent and scanning electron beam. Pulse type device appropriates the large area process. But it does not control the beam dosage. Scanning type device has advantages for dosage control and edge deburring. We design the convergence and scan type. It has magnetic lenses for convergence and scan device for scanning beam. Magnetic lenses consist of convergent and objective lens. The lenses are designed by the specification(beam size and working distance). In this paper, we evaluate the convergence performance by pattern process. Also, we analysis the results and important factors for process. The important factors for process are beam size, pressure, stage speed and vacuum. These results will be utilized into systematizing pattern shape and the factors.

자기혼합형 LDF 프로브와 혈류 시뮬레이터의 구현 (Implementation of a self-mixing type LDF probe and blood flow simulator)

  • 고한우;김종원
    • 센서학회지
    • /
    • 제8권2호
    • /
    • pp.133-138
    • /
    • 1999
  • In this pager, the authors have implemented a blood flow simulator and a LDF(laser Doppler flowmeter) probe using self-mixing effect of the laser diode. The purpose of the blood flow simulator is to simulate microvascular blood flow in tissue. It consists of melinex film (thickness = $123\;{\mu}m$) which has similar optical characteristics to epidermis and porous polyethylene filter (Vyon, porosity 35%, mean pore size $50\;{\mu}m$, thickness=1 mm) which has similar optical characteristics to dermis. The blood flowmeter probe consists of laser diode(5 mW, 780 nm wavelength), CD lens(focal length 12 mm). current-to-voltage converter, highpass filter, and premplifier. It doesn't need optical fiber, therefore, implementation of the probe is simpler than conventional probe using optical fiber.

  • PDF

청색 레이저 다이오드를 이용한 홀로그래픽 데이터 저장장치 (Holographic Data Storage System Using Blue Laser Diode)

  • 곽봉식;이성훈;하상우;정용우;김진아;서정교;최인호
    • 정보저장시스템학회:학술대회논문집
    • /
    • 정보저장시스템학회 2005년도 추계학술대회 논문집
    • /
    • pp.42-43
    • /
    • 2005
  • Higher density in the holographic storage can be obtained by using shorter wavelength laser and higher numerical aperture (NA). In this paper, we adopted a blue laser diode with a wavelength of 405nm and high NA object lens. And the phase conjugation method is applied to prevent image distortion due to high NA. The performance of the system has been shown experimentally.

  • PDF

레이저용접부 온도측정을 위한 적외선 온도측정장치의 개발에 관한 연구 (II) - 적외선 온도측정에서 제인자의 영향 - (A Study of the Infrared Temperature Sensing System far Measuring Surface Temperature in Laser Welding(II) - Effect of the System Parameter on Infrared Temperature Measurement -)

  • 이목영;김재웅
    • Journal of Welding and Joining
    • /
    • 제20권1호
    • /
    • pp.69-75
    • /
    • 2002
  • This study investigated the effect of the system parameters on penetration depth measurement using infrared temperature sensing system. The distance from focusing lens to detector was varied to diminish the error in measuring weld bead width. The effect of bead surface shape on measured surface temperature profile was evaluated using specimen heated by electric resistance. The measuring distance from laser beam was changed to optimize the measuring point. The results indicated that the monitoring device of surface temperature using infrared detector array was applicable to real time penetration depth control.

극초단 펄스 Cr4+:YAG 레이저의 제작 및 동작 특성 (Construction and operational characteristics of a Ultra-Short pulse Cr4+:YAG laser)

  • 이봉연;이동한;이치원;윤석범;추한태
    • 한국광학회지
    • /
    • 제15권5호
    • /
    • pp.455-460
    • /
    • 2004
  • 1.064 $\mu\textrm{m}$ 파장의 연속발진 Nd:YAG 레이저를 펌핑 광원으로 하여 적외선 영역에서 광대역으로 파장 가변되는 연속발진 및 극초단펄스 C $r^{4+}$ :YAG 레이저를 자체 제작하였다. C $r^{4+}$ :YAG 레이저의 연속발진 및 펄스의 출력특성과 파장 가변 영역은 다음과 같다. 연속발진일 경우 1.436 $\mu\textrm{m}$에서 600 mW의 평균출력을 보였으나, 복굴절 필터를 삽입했을 경우는 1.492 $\mu\textrm{m}$근처에서 400 mW의 평균출력을 보였다. 펄스발진일 경우 1.436 $\mu\textrm{m}$에서 최초로 평균출력 320 mW의 모드록킹된 펄스가 발생하였지만 물 흡수대의 영향으로 불안정함을 피할 수 없었다. 따라서, 복굴절 필터를 사용하여 중심파장을 1.492 $\mu\textrm{m}$로 이동시켰으며 이 영역에서 안정한 상태의 모드록킹된 43 fs의 극초단 펄스를 생성하였다. 이 때의 평균출력은 280 mW이고, 반치폭(FWHM)은 45 nm이었다.