A Study on the Motion Characteristics of the Ultrasonic Transport System using Laser Scanning Vibrometer

레이저 진동 측정기를 이용한 초음파 이송 시스템의 동작특성에 관한 연구

  • 정상화 (조선대학교 기계공학과) ;
  • 신병수 (조선대학교 대학원 기계공학과) ;
  • 이경형 (조선대학교 대학원 기계공학과)
  • Published : 2003.10.01

Abstract

In the semiconductor and the optical industry a new transport system which can replace the conventional sliding system is required. These systems are driven by magnetic field and conveyer belt. The magnetic field damages semiconductor and contact force scratches the optical lens. The ultrasonic wave driven system can solve these problem. In this paper, the vibration behavior of flexural beam in the ultrasonic transport system is verified using Laser Scanning Vibrometer. The experiments for verifying vibration are performed in three conditions such as in the maximum transport speed, in the zero speed, and in the change of transport direction.

Keywords