• 제목/요약/키워드: Laser Surface Treatment

검색결과 323건 처리시간 0.028초

산부식후 상아질 표면의 습윤 또는 건조가 상아질 결합에 미치는 영향 (EFFECTS OF DENTIN SURFACE WETNESS OR DESICCATION AFTER ACID ETCHING ON DENTIN BONDING)

  • 양원경;권혁춘;손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제25권2호
    • /
    • pp.243-253
    • /
    • 2000
  • The purpose of this in vitro study was to evaluate dentin bonding by two different dentin bonding systems(DBS) using acetone based primer or adhesive [All Bond 2(AB2), One Step(OS)] when they were applied by wet or dry bonding technique. Morphology of resin-dentin interface and hybrid layer thickness(HLT) were investigated using Confocal Laser Scanning Microscope(CLSM) and compared to shear bond strength(SBS). 72 extracted sound human molars were randomly divided into 4 groups of 18 teeth each - Group 1.(AW); AB2 by wet bonding. Group 2(AD); AB2 by dry bonding. Group 3.(OW); OS by wet bonding, Group 4.(OD); OS by dry bonding. In 6 teeth of each group, notch-shaped class V cavities(depth 2mm) were prepared on buccal and lingual surface at the cementoenamel juction(12 cavities per group). To obtain color contrast in CLSM observation, bonding resins of each DBS were mixed with rhodamine B and primer of AB2 was mixed with sodium fluorescein. Prepared teeth of each group were treated with AB2, OS, respectively according to the manufacturer's instructions except for dentin surface moisture treatment after acid etching. In group 1 and 3, after acid etching, excess water was removed with wet tissue(Kimwipes), leaving consistently shiny, visibly hydrated dentin surface. In group 2 and 4, dentin surface was dried for 10 seconds at 1 inch distance. The treated teeth were then packed with composite resin(${\AE}$litefil) and light-cured. 12 microscopic samples($60{\sim}80{\mu}m$ thickness) of each group were obtained after longitudinal section and grinding(Exakt cutting and grinding system). Morphological investigation of resin-dentin interface and HLT measurement using CLSM were done. For measurement of SBS, remaining 12 teeth of each group were flattened occlusally to remove all enamel and grinded to 500 grit SiC(Pedemet Specimen Preparation Equipment). After applying DBS on the exposed dentin surface, composite resin was applied in the shape of cylinder, which has 5mm diameter, 1.5mm thickness, and light cured. SBS was measured using Instron with a crosshead speed of 0.5mm/min. It was concluded as follows, 1. HLT of AW(mean: $2.59{\mu}m$) was thicker than any other group, and followed by AD, OW, OD in descending order(mean; 2.37, 2.28, $1.92{\mu}m$). Only OD had statistically significant differences(p<0.05) to AW and AD. 2. There were intimate contact of resin and dentin at the interface in wet bonding groups, but gaps or irregular interfaces were observed in dry bonding groups. 3. The length, diameter, density of resin tags were various even in the same group without significant differences between groups and lots of adhesive lateral branches were observed. 4. There were no statistically significant difference of SBS between AB2 and OS, but SBS of wet bonding groups were significantly higher(p<0.05) than dry bonding groups. 5. There were no consistent relationships between HLT and SBS.

  • PDF

타액에 오염된 상아질에 대한 콤포머의 접합양상 (THE ADHESIVE PATTERNS OF COMPOMER TO SALIVA-CONTAMINATED DENTIN)

  • 조영곤;김병태;이석종
    • Restorative Dentistry and Endodontics
    • /
    • 제25권4호
    • /
    • pp.575-586
    • /
    • 2000
  • In this study, adaptation of compomer to saliva contaminated dentin was evaluated with scanning electron microscope(SEM) and confocal laser scanning microscope(CLSM). For the SEM study, the occulusal surfaces of thirty two molar teeth were grounded to exposure dentin surfaces. The specimen were randomly assigned to control and three experimental groups with four samples in each group. In control group, Dyract and F-2000 compomer were bonded on the specimens according to the manufactures direction. Experimental groups were subdivided into three groups. They were contaminated with saliva on dentin surfaces ; Experimental group 1 : Saliva was dried with compressed air. Experimental group 2 : Saliva was rinsed with air-water spray and dried. Experimental group 3 : After polymerization of an adhesive, they were contaminated with saliva, and then saliva was rinsed with air-water spray and dried. Dyract and F-2000 compomer were bonded on saliva-treated dentin surfaces. The interfaces between dentin and compomer were observed with SEM. For the CLSM study, Class V cavities were prepared in buccal and ligual surfacess of thirty two molars. The specimens were divided into control and experimental groups. Class V cavities in experimental group were contaminated with saliva and those surfaces in each experimental groups received the same treatments as for the SEM study. Cavities were applied Prime & Bond 2.1 and F-2000 compomer primer/adhesive that were mixed with fluorescein, and then were filled with Dyract and F-2000 compomer. Specimens were embedded in transparent acrylic resin and sectioned buccolingual1y with diamond wheel saw, and then mounted on cover slide for CLSM study. The interface between cavity and compomer was observed by fluoresence imaging with a CLSM. The results were as follows : 1. In SEM exammination of Dyract group, control group, experimental group 2, 3 showed close adaptation to dentin and hybrid layer of $3{\sim}4{\mu}m$ diameter. Interfacial gap between compomer and dentin in experimental group 1 was wider than in control group. 2. In SEM examination of F-2000 group, adaptation to dentin of control group was closer than Dytact control group, but hybrid-like layer was not observed. Interfacial gap between compomer and dentin in experimental group 1 was wider than in Dyract experimental group 1. 3. In dissolution specimens of Dyract and F-2000 group, resin tags penetrated through dentinal tubules in control group and experimental group 1 and 3, but the penetration of resin tag was irregular and partial in experimental group 1. 4. In CLSM exammination of Dyract and F-2000 group, adhesive patterns of control and experimental groups showed same as in SEM. This result suggests the treatment methods, rinsing & drying, repeating all adhesive procedures, will produce good effect on adaptation of compomer to dentin if the dentin surface or polymerized adhesive is contaminated by saliva.

  • PDF

Efficacy of an LED toothbrush on a Porphyromonas gingivalis biofilm on a sandblasted and acid-etched titanium surface: an in vitro study

  • Lee, Hae;Kim, Yong-Gun;Um, Heung-Sik;Chang, Beom-Seok;Lee, Si Young;Lee, Jae-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • 제48권3호
    • /
    • pp.164-173
    • /
    • 2018
  • Purpose: The aim of this study was to evaluate the antimicrobial effect of a newly devised toothbrush with light-emitting diodes (LEDs) on Porphyromonas gingivalis attached to sandblasted and acid-etched titanium surfaces. Methods: The study included a control group, a commercial photodynamic therapy (PDT) group, and 3 test groups (B, BL, and BLE). The disks in the PDT group were placed in methylene blue and then irradiated with a diode laser. The B disks were only brushed, the BL disks were brushed with an LED toothbrush, and the BLE disks were placed into erythrosine and then brushed with an LED toothbrush. After the different treatments, bacteria were detached from the disks and spread on selective agar. The number of viable bacteria and percentage of bacterial reduction were determined from colony counts. Scanning electron microscopy was performed to visualize bacterial alterations. Results: The number of viable bacteria in the BLE group was significantly lower than that in the other groups (P<0.05). Scanning electron microscopy showed that bacterial cell walls were intact in the control and B groups, but changed after commercial PDT and LED exposure. Conclusions: The findings suggest that an LED toothbrush with erythrosine treatment was more effective than a commercial PDT kit in reducing the number of P. gingivalis cells attached to surface-modified titanium in vitro.

Chitosan/hydroxyapatite composite coatings on porous Ti6Al4V titanium implants: in vitro and in vivo studies

  • Zhang, Ting;Zhang, Xinwei;Mao, Mengyun;Li, Jiayi;Wei, Ting;Sun, Huiqiang
    • Journal of Periodontal and Implant Science
    • /
    • 제50권6호
    • /
    • pp.392-405
    • /
    • 2020
  • Purpose: Titanium implants are widely used in the treatment of dentition defects; however, due to problems such as osseointegration failure, peri-implant bone resorption, and periimplant inflammation, their application is subject to certain restrictions. The surface modification of titanium implants can improve the implant success rate and meet the needs of clinical applications. The goal of this study was to evaluate the effect of the use of porous titanium with a chitosan/hydroxyapatite coating on osseointegration. Methods: Titanium implants with a dense core and a porous outer structure were prepared using a computer-aided design model and selective laser sintering technology, with a fabricated chitosan/hydroxyapatite composite coating on their surfaces. In vivo and in vitro experiments were used to assess osteogenesis. Results: The quasi-elastic gradient and compressive strength of porous titanium implants were observed to decrease as the porosity increased. The in vitro experiments demonstrated that, the porous titanium implants had no biological toxicity; additionally, the porous structure was shown to be superior to dense titanium with regard to facilitating the adhesion and proliferation of osteoblast-like MC3T3-E1 cells. The in vivo experimental results also showed that the porous structure was beneficial, as bone tissue could grow into the pores, thereby exhibiting good osseointegration. Conclusions: Porous titanium with a chitosan/hydroxyapatite coating promoted MC3T3-E1 cell proliferation and differentiation, and also improved osseointegration in vitro. This study has meaningful implications for research into ways of improving the surface structures of implants and promoting implant osseointegration.

Glass/Al/$SiO_2$/a-Si 구조에서 마이크론 크기의 구멍을 통한 금속유도 실리콘 결정화 특성 (Characteristics of metal-induced crystallization (MIC) through a micron-sized hole in a glass/Al/$SiO_2$/a-Si structure)

  • 오광환;정혜정;지은옥;김지찬;부성재
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.59.1-59.1
    • /
    • 2010
  • Aluminum-induced crystallization (AIC) of amorphous silicon (a-Si) is studied with the structure of a glass/Al/$SiO_2$/a-Si, in which the $SiO_2$ layer has micron-sized laser holes in the stack. An oxide layer between aluminum and a-Si thin films plays a significant role in the metal-induced crystallization (MIC) process determining the properties such as grain size and preferential orientation. In our case, the crystallization of a-Si is carried out only through the key hole because the $SiO_2$ layer is substantially thick enough to prevent a-Si from contacting aluminum. The crystal growth is successfully realized toward the only vertical direction, resulting a crystalline silicon grain with a size of $3{\sim}4{\mu}m$ under the hole. Lateral growth seems to be not occurred. For the AIC experiment, the glass/Al/$SiO_2$/a-Si stacks were prepared where an Al layer was deposited on glass substrate by DC sputter, $SiO_2$ and a-Si films by PECVD method, respectively. Prior to the a-Si deposition, a $30{\times}30$ micron-sized hole array with a diameter of $1{\sim}2{\mu}m$ was fabricated utilizing the femtosecond laser pulses to induce the AIC process through the key holes and the prepared workpieces were annealed in a thermal chamber for 2 hours. After heat treatment, the surface morphology, grain size, and crystal orientation of the polycrystalline silicon (pc-Si) film were evaluated by scanning electron microscope, transmission electron microscope, and energy dispersive spectrometer. In conclusion, we observed that the vertical crystal growth was occurred in the case of the crystallization of a-Si with aluminum by the MIC process in a small area. The pc-Si grain grew under the key hole up to a size of $3{\sim}4{\mu}m$ with the workpiece.

  • PDF

최신 근관 세척 방법과 기구에 대한 고찰 (Review of root canal irrigant delivery techniques and devices)

  • 유연지;신수정;백승호
    • Restorative Dentistry and Endodontics
    • /
    • 제36권3호
    • /
    • pp.180-187
    • /
    • 2011
  • 서론: 근관 치료의 성공을 위해 근관계 내에 남아있는 조직 잔사와 박테리아를 제거하는 것은 매우 중요하다. 그러나 충분한 근관 형성과 근관 세척을 하더라도 근관의 복잡한 형태로 인하여 근관 내 박테리아의 biofilm이나 괴사된 치수 조직이 남아 있게 된다. 근래 보다 효과적으로 근관 세척을 하기 위한 여러 가지 방법과 근관 세척을 위한 기구들이 개발되었다. 본 종설에서는 근관 치료 영역에서 사용되는 근관 세척 방법과 기구에 대해 고찰하고자 한다. 본론: 아래와 같은 기구와 방법이 논의된다. - syringe-needle irrigation, manual dynamic irrigation, brushes - sonic and ultrasonic irrigation, passive ultrasonic irrigation, rotary brush, RinsEndo, EndoVac, Laser 결론: 최근 근관 세척을 위한 기구와 세정 방법이 개발되었으나, syringe와 needle을 이용한 근관 세척법과 ultrasonic을 이용한 근관 세척법을 제외하고는 새로 개발된 많은 기구들의 임상적 치료 결과의 향상에 대한 근거 중심 연구가 아직은 부족하며, 어떠한 기구나 장치도 근관 내 잔사를 완벽하게 제거할 수는 없다. 효과적인 근관 세척을 위해서는 적절한 근관 세척제의 선택과 함께, 근관 세척제를 근관장까지 충분한 양이 도달할 수 있도록 적절한 근관 세척 기구와 방법을 선택하여야 한다.

INTERGRANULAR CORROSION-RESISTANT STAINLESS STEEL BY GRAIN BOUNDARY ENGINEERING

  • Hiroyuki Kokawa;Masayuki Shimada;Wang, Zhan-Jie;Yutaka S. Sato
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2002년도 Proceedings of the International Welding/Joining Conference-Korea
    • /
    • pp.250-254
    • /
    • 2002
  • Intergranular corrosion of austenitic stainless steels is a conventional and momentous problem during welding and high temperature use. One of the major reasons for such intergranular corrosion is so-called sensitization, i.e., chromium depletion due to chromium carbide precipitation at grain boundaries. Conventional methods for preventing sensitization of austenitic stainless steels include reduction of carbon content in the material, stabilization of carbon atoms as non-chromium carbides by the addition of titanium, niobium or zirconium, local solution-heat-treatment by laser beam, etc. These methods, however, are not without drawbacks. Recent grain boundary structure studies have demonstrated that grain boundary phenomena strongly depend on the crystallographic nature and atomic structure of the grain boundary, and that grain boundaries with coincidence site lattices are immune to intergranular corrosion. The concept of "grain boundary design and control", which involves a desirable grain boundary character distribution, has been developed as grain boundary engineering. The feasibility of grain boundary engineering has been demonstrated mainly by thermomechanical treatments. In the present study, a thermomechanical treatment was tried to improve the resistance to the sensitization by grain boundary engineering. A type 304 austenitic stainless steel was pre-strained and heat-treated, and then sensitized, varying the parameters (pre-strain, temperature, time, etc.) during the thermomechanical treatment. The grain boundary character distribution was examined by orientation imaging microscopy. The intergranular corrosion resistance was evaluated by electrochemical potentiokinetic reactivation and ferric sulfate-sulfuric acid tests. The sensitivity to intergranular corrosion was reduced by the thermomechanical treatment and indicated a minimum at a small roll-reduction. The frequency of coincidence-site-lattice boundaries indicated a maximum at a small strain. The ferric sulfate-sulfuric acid test showed much smaller corrosion rate in the thermomechanically-treated specimen than in the base material. An excellent intergranular corrosion resistance was obtained by a small strain annealing at a relatively low temperature for long time. The optimum parameters created a uniform distribution of a high frequency of coincidence site lattice boundaries in the specimen where corrosive random boundaries were isolated. The results suggest that the thermomechanical treatment can introduce low energy segments in the grain boundary network by annealing twins and can arrest the percolation of intergranular corrosion from the surface.

  • PDF

티타늄 표면에 형성한 Staphylococcus aureus 바이오필름에 대한 인도시아닌 그린을 활용한 광역학치료의 항미생물 효과 (Antimicrobial effect of infrared diode laser utilizing indocyanine green against Staphylococcus aureus biofilm on titanium surface)

  • 김승기;이시영;이종빈;엄흥식;이재관
    • 구강회복응용과학지
    • /
    • 제40권2호
    • /
    • pp.55-63
    • /
    • 2024
  • 목적: 이 연구의 목적은 거친 티타늄 표면에 형성된 Staphylococcus aureus 바이오필름에 대해 인도시아닌 그린을 활용한 광역학치료(photodynamic therapy; PDT)의 항미생물 효과를 평가하고, 이를 임상에서 널리 사용되는 다른 화학 처치 방법과 비교하는 것이다. 연구 재료 및 방법: 멸균된 거친 표면 티타늄 디스크에 S. aureus ATCC 25923을 접종한 후 48시간 동안 배양하여 바이오필름을 형성하였다. 실험은 대조군, 클로르헥시딘군(CHX), 테트라싸이클린군(TC), 인도시아닌 그린군(ICG), 인도시아닌 그린을 활용한 광역학치료군(ICG-PDT)으로 구분하여 진행하였다. 군에 따른 처리 후 세균을 배양하여 세균 수(colony forming unit; CFU)를 계산하고, 바이오필름을 공초점 현미경을 통해 분석하였다. 통계 분석은 CFU값을 로그값으로 변환한 후 분산 분석을 시행하였다. 결과: 모든 실험군은 대조군과 비교하여 유의한 항미생물 효과를 나타냈으며(P < 0.05), 특히 CHX, TC, PDT 군에서 90% 이상의 유의한 효과를 보였다(P < 0.01). CHX 군은 TC, PDT 군과 유의한 차이를 보이지 않았으나(P > 0.05), PDT 군은 TC보다 유의하게 효과적이었다(P = 0.035). 공초점현미경 상에서 PDT 군에서 사균의 비율이 더 높게 관찰되었다. 결론: 이번 연구를 통해 인도시아닌 그린을 활용한 광역학치료가 SLA 티타늄 표면에 형성된 S. aureus 바이오필름 제거에 있어 효과적임을 확인하였다.

SLA 3D 프린팅 방식 기반의 미세 유체 시스템 제작을 위한 소수성 표면 처리 연구 (A Study on Hydrophobic Surface Treatment for Microfluidic System Fabrication Based on SLA 3D Printing Method)

  • 허재욱;배서준;임도진
    • Korean Chemical Engineering Research
    • /
    • 제62권1호
    • /
    • pp.105-111
    • /
    • 2024
  • SLA (Stereo Lithography Apparatus) 방식은 액체 상태의 광경화성 레진(Resin)이 자외선 레이저에 닿으면 고체가 되는 원리를 활용한 3D 프린팅 방식으로 다양한 분야에서의 활용도가 증가하고 있다. 본 연구에서는 이 SLA 3D 프린팅 출력물의 표면 특성 중 소수성과 투명도를 개선하여 미세 유체 시스템의 제작에 활용하기 위한 기초 연구를 수행하였다. SLA 출력물은 소수성 코팅 방법을 이용해 표면 소수성의 특성을 개선할 수 있었으나, 소수성 코팅 방법의 종류에 따라 다양한 환경에서의 코팅 유지력은 차이를 보였다. 또한, 미세 유체 시스템의 제작에 요구되는 충분한 투명도와 소수성의 특성을 함께 확보하기 위해 선행된 연구에서 제안한 투명도 확보 방법에 소수성 코팅을 적용하여 접촉각의 변화를 비교하였다. Teflon 코팅법이 이산화 티타늄 코팅법과 비교하여 우수한 투명도의 확보가 가능하며, 다양한 환경에 노출되었을 때 높은 코팅의 유지력을 가져 미세 유체 시스템의 제작에 활용되기에 적합한 소수성 코팅법으로 제안되었다. 마지막으로 본 연구를 통해 제안된 미세 유체 시스템의 제작에 적합한 소수성 코팅 방법인 Teflon 코팅법 중 Fluoropel 800을 이용하여 디지털 미세 유체 시스템 중 하나인 액적 접촉 충전 현상(Electrophoresis of Charged Droplet, ECD) 칩을 SLA 3D 프린팅으로 제작, 액적의 조작을 성공적으로 시연함으로써 SLA 3D 프린팅 기술의 미세 유체 시스템의 제작에 활용 가능성을 확인하였다.

상기도 폐색을 초래한 기관내 다발성 유두종증 1예 (Tracheal Papillomatosis Causing Upper Airway Obstruction)

  • 이승룡;김제형;권영환;이소라;이상엽;이신형;서정경;심재정;조재연;인광호;강경호;유세화
    • Tuberculosis and Respiratory Diseases
    • /
    • 제45권4호
    • /
    • pp.876-881
    • /
    • 1998
  • 기관지 확장제 등의 치료에도 호전되지 않는 운동성 호흡 곤란을 주소로 내원하여 기관지 내시경, 경부 컴퓨터 단층 촬영상 기관 유두종증 진단 받고 2 차례 레이저 치료를 시행받은 후 호흡 곤란 증상과 폐기능 검사 소견이 호전된 기관 유두종증 1예를 경험하였기에 문헌 고찰과 함께 보고하는 바이다.

  • PDF