• Title/Summary/Keyword: Laser Scanning Microscope

Search Result 323, Processing Time 0.029 seconds

Comparison of the Morphological Properties of the Traditional Handmade Papers Using CLSM (CLSM을 이용한 전통 수록지의 형태학적 특성 비교)

  • 조중연;민춘기;이선호
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.32 no.4
    • /
    • pp.87-94
    • /
    • 2000
  • The morphological properties of the traditional handmade papers made in Korea, China and Japan were identified using CLSM(Confocal Laser Scanning Microscope). It was shown that the primary and secondary wall of the Hanji fibers were separated. The lumen of the fibers was not observed. Dochim, a traditional way of Hanji calendering, was turned out to accelerate the separation of the two walls, by which the unique effects of Dochim could be obtained. There were no separation of the two walls in Chinese handmade paper and Japanese handmade paper. Lumen was not observed in Senji fibers but it was observed in Whasi fibers. It was postulated that the morphological properties of the fibers are closely related with the calligraphic writings or drawings properties of handmade papers.

  • PDF

Measurements of Evanescent Wave using a Mano-size Optical Probe (나노 사이즈 광프로브에 의한 에버네슨트파의 측정)

  • 최영규
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.1
    • /
    • pp.30-35
    • /
    • 2004
  • We have carried out a basic experiment in order to develope a super high-resolution optical microscope which transcend the limitation of diffraction and the wavelength of lightwave. The image of this scope is composed by measuring the evanescent wave which is localized on the surface of the testing materials. A detecting probe was fabricated with a single mode optical fiber to be sharpened by the chemical etching, and drived by PZT. The standing wave of $0.33\mu\textrm{m}$ wavelength evanescent wave which was generated from the $0.78\mu\textrm{m}$-wavelength semiconductor laser was detected by the $0.5\mu\textrm{m}$-thickness optical fiber probe.

Surface roughness model of end-milling surface (엔드밀 가공면의 표면거칠기 모델)

  • Chin, Do-Hun;Kim, Jong-Do;Yoon, Moon-Chul
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.2
    • /
    • pp.68-74
    • /
    • 2013
  • In this paper, an average surface roughness, $R_a$, was measured by optical measurement and its mathematical model according to spindle speed and feedrate was obtained by least square method. Also, its result is compared and investigated with real measured average surface roughness. The optical measurement of surface roughness is performed by CLSM(confocal laser scanning microscope) and the captured HEI(height encoded image) data is used as an original data for the generation of average surface roughness and its mathematical plane or contour surface of surface roughness. Using this polynomial model with two independent variables, the behavior of an average surface roughness is investigated and analyzed with an experimental modeling of least square algorithm. And it can be used for the prediction of $R_a$ in different condition of machining.

The effect of multiple application on microtensile bond strength of all-in-one dentin adhesive systems

  • Son, Sung-ae;Hur, Bock
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.567-567
    • /
    • 2003
  • The purpose of this study was to evaluate the effect of multiple application of all-in-one dentin adhesive system on microtensile bond strength using confocal laser scanning microscope and microtensile bond strength test. The dentin surface of human molars, sectioned to remove the enamel from the occlusal surface were prepared. In group I, Scotchbond Multipurpose(SM, 3M ESPE) was applied by manufature's recommended. In group II, after the all-in-one adhesive, Adper Prompt L-Pop was applied for 15s, and light cured for 10s, the second coat was re-applied and light-cured.(omitted)

  • PDF

Reconstruction of Collagen Using Tensor-Voting & Graph-Cuts

  • Park, Doyoung
    • Journal of Advanced Information Technology and Convergence
    • /
    • v.9 no.1
    • /
    • pp.89-102
    • /
    • 2019
  • Collagen can be used in building artificial skin replacements for treatment of burns and towards the reconstruction of bone as well as researching cell behavior and cellular interaction. The strength of collagen in connective tissue rests on the characteristics of collagen fibers. 3D confocal imaging of collagen fibers enables the characterization of their spatial distribution as related to their function. However, the image stacks acquired with confocal laser-scanning microscope does not clearly show the collagen architecture in 3D. Therefore, we developed a new method to reconstruct, visualize and characterize collagen fibers from fluorescence confocal images. First, we exploit the tensor voting framework to extract sparse reliable information about collagen structure in a 3D image and therefore denoise and filter the acquired image stack. We then propose to segment the collagen fibers by defining an energy term based on the Hessian matrix. This energy term is minimized by a min cut-max flow algorithm that allows adaptive regularization. We demonstrate the efficacy of our methods by visualizing reconstructed collagen from specific 3D image stack.

The effect of a desensitizer and $CO_2$ laser irradiation on bond performance between eroded dentin and resin composite

  • Ding, Meng;Shin, Sang-Wan;Kim, Min-Soo;Ryu, Jae-Jun;Lee, Jeong-Yol
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.3
    • /
    • pp.165-170
    • /
    • 2014
  • PURPOSE. This study was aimed to evaluate effect of the desensitizing pretreatments on the micro-tensile bond strengths (${\mu}TBS$) to eroded dentin and sound dentin. MATERIALS AND METHODS. Forty-two extracted molars were prepared to form a flat dentin surface, and then they were divided into two groups. Group I was stored in distilled water while group II was subjected to a pH cycling. Each group was then subdivided into three subgroups according to desensitizing pretreatment used: a) pretreatment with desensitizer (Gluma); b) pretreatment with $CO_2$ Laser (Ultra Dream Pluse); c) without any pretreatment. All prepared surfaces were bonded with Single Bond 2 and built up with resin composite (Filtek Z250). The micro-tensile bond test was performed. Fracture modes were evaluated by stereomicroscopy. Pretreated surfaces and bonded interfaces were characterized by scanning electron microscope (SEM). The data obtained was analyzed by two-way ANOVA (${\alpha}$=0.05). RESULTS. For both sound and eroded dentin, samples treated with desensitizer showed the greatest ${\mu}TBS$, followed by samples without any treatment. And samples treated with $CO_2$ laser showed the lowest ${\mu}TBS$. SEM study indicated that teeth with eroded dentin appeared prone to debonding, as demonstrated by existence of large gaps between adhesive layers and dentin. CONCLUSION. Pretreatment with Gluma increased the ${\mu}TBS$ of Single Bond 2 for eroded and sound teeth. $CO_2$ laser irradiation weakened bond performance for sound teeth but had no effect on eroded teeth.

A STUDY ON THE DISTRIBUTION OF CALCITONIN GENE-RELATED PEPTIDE CONTAINING NERVE FIBERS IN RAT PULP FOLLOWING DENTINAL INJURY (상아질 손상 후 흰쥐 대구치 치수의 calcitonin gene-related peptide(CGRP) 함유 신경섬유 분포에 관한 연구)

  • Moon, Joo-Hoon;Park, Sang-Jin;Min, Byung-Soon;Choi, Ho-Young;Cho, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.1
    • /
    • pp.100-115
    • /
    • 1999
  • The purpose of this study was to investigate the distribution of calcitonin gene-related peptide containing nerve fibers in rat pulp after dentinl injury by means of immunohistochemistry and confocal laser scanning microscope. The Spague-Dawley rats weighing about 250-300gm were used. The animals were devided into normal control and experimental groups. Experimental animals were sacrified 1, 2, 4, 7, 10, 21days after dentinal injury (dentin cutting, and then acid etching with 35% phosphoric acid) on the maxillary molar teeth. The maxillary teeth and alveolar bone were removed and immersed in the 4% paraformaldehyde in 0.1M phosphate buffer (pH 7.4), then were decalcified with 15% formic acid for 10 days. Serial frozen $50{\mu}m$ thick sections were cut on a cryostat. The rabbit CGRP antibody was used as a primary antibody with a dilution of 1:2000 in 0.01M PB. The sections were incubated for 48 hours at $4^{\circ}C$, and placed into biotinylated antirabbit Ig G as a secondary anti body with dilution of 1:200 in 0.01M PB and incubated in ABC(avidin-biotin complex). The peroxidase reaction was visualized by incubating the sections in 0.05% 3,3 diaminobenzidine tetrahydrochloride containing 0.02% $H_2O_2$. For the confocal laser scanning microscopic examination, Primary antibody reaction was same as immunoperoxidase stainning, but fluorescein isothiocyanate(FITC)-conjugate antirabbit IgG as a secondary antibody was used. The confocal laser scanning microscope was used for the examination. A series of images of optical sections was collected with a 20x objective at $3{\mu}m$ intervals throughout the depth of specimen. FITC fluerescence was registrated through a 488nm and 568nm excitation filter, and images were saved on optical disk. The stereoscopic images and three dimentionnal images were reconstructed by computer software, and then were analyzed. The results were as follows : 1. In normal control group, CGRP containing nerve fibers were coursed through the root with very little branching, and then formed a dense network of terminals in coronal pulp. 2. A slight increase in CGRP containing nerve fibers at 1 and 2day postinjury was noted subjacent to the injury site. In the 4day group, there were an extensive increase in the number of reactive fibers, followed by a partial return toward normal levels at 7~10 day postinjury, and return by 21days. 3. The sprouting of the CGRP containing nerve fibers was evident within 2day after dentinal injury, and by 4days there was a maximal increased, but was decreased at 7days and returned to normal 10~21 day postinjury. 4. In confocal laser scanning microscopic exammination, the distinct distribution pattern and sprouting reaction of CGRP containing nerve fibers were observed in stereoscopic images and three dimentional images. These results suggest that CGRP containing nerve fiber can be important role in the response to dental injury and pain regulation.

  • PDF

SURFACE CHARACTERISTICS OF ANODIC OXIDIZED TITANIUM ACCORDING TO THE PORE SIZE

  • Ha Heon-Seok;Kim Chang-Whe;Lim Young-Jun;Kim Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.3
    • /
    • pp.343-355
    • /
    • 2006
  • Statement of problem. The success of osseointegration can be enhanced with an implant that has improved surface characteristics. Anodic oxidation is one of the surface modifying method to achieve osseointegration. Voltage of anodic oxidation can change surface characteristics and cell activity Purpose. This study was performed to evaluate MG63 cell responses such as affinity, proliferation and to compare surface characteristics of anodic oxidized titanium in various voltage. Material and method. The disks for cell culture were fabricated from grade 3 commercially pure titanium,1 m in thickness and 12 mm in diameter. Surfaces of 4 different roughness were prepared. Group 1 had a machined surface, used as control. Group 2 was anodized under 220 V, group 3 was anodized under 300 V and group 4 was anodized under 320 V. The microtopography of specimens was observed by scanning electron microscope (JSM-840A, JEOL, Japan) and atomic force microscope(Autoprobe CP, Park Scientific Instrument, USA). The surface roughness was measured by confocal laser scanning microscope(Pascal, LSM5, Zeiss, Germany). The crystal structure of the titanium surface was analyzed with x-ray diffractometer(D8 advanced, Broker, Germany). MG63 osteoblast-like cells were cultured on these specimens. The cell morpholgy was observed by field emission electron microscope(Hitachi S-4700, Japan). The cell metabolic and proliferative activity was evaluated by MTT assay Results and conclusion. With in limitations of this in vitro study, the following conclusions were drawn. 1. In anodizing titanium surface, we could see pores which did not show in control group. In higher anodizing voltage, pore size was increased. 2. In anodizing titanium surface, we could see anatase. In higher anodizing voltage, thicker oxide layer increased crystallinity(anatase, anatase and rutile mixed). 3. MG63 cells showed more irregular, polarized and polygonal shape and developed more lamellipodi in anodizing group as voltage increased. 4. The activity of cells in MTT assay increased significantly in group 3 and 4 in comparison with group 1 and 2. However, there was no difference between group 3 and 4 at P<0.05. Proliferation of MG63 cells increased significantly in pore size($3-5.5{\mu}m$) of group 3 and 4 in comparison with in pore size($0.2-1{\mu}m$ ) of group 2.

The Fabrication and Characterization of Embedded Switch Chip in Board for WiFi Application (WiFi용 스위치 칩 내장형 기판 기술에 관한 연구)

  • Park, Se-Hoon;Ryu, Jong-In;Kim, Jun-Chul;Youn, Je-Hyun;Kang, Nam-Kee;Park, Jong-Chul
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.15 no.3
    • /
    • pp.53-58
    • /
    • 2008
  • In this study, we fabricated embedded IC (Double Pole Double throw switch chip) polymer substrate and evaluate it for 2.4 GHz WiFi application. The switch chips were laminated using FR4 and ABF(Ajinomoto build up film) as dielectric layer. The embedded DPDT chip substrate were interconnected by laser via and Cu pattern plating process. DSC(Differenntial Scanning Calorimetry) analysis and SEM image was employed to calculate the amount of curing and examine surface roughness for optimization of chip embedding process. ABF showed maximum peel strength with Cu layer when the procuring was $80\sim90%$ completed and DPDT chip was laminated in a polymer substrate without void. An embedded chip substrate and wire-bonded chip on substrate were designed and fabricated. The characteristics of two modules were measured by s-parameters (S11; return loss and S21; insertion loss). Insertion loss is less than 0.55 dB in two presented embedded chip board and wire-bonded chip board. Return loss of an embedded chip board is better than 25 dB up to 6 GHz frequency range, whereas return loss of wire-bonding chip board is worse than 20 dB above 2.4 GHz frequency.

  • PDF

Weldability with Process Parameters During Fiber Laser Welding of a Titanium Plate (I) - Effect of Type and Flow Rate of Shielding Gases on Weldability - (티타늄 판재의 파이버 레이저 용접시 공정변수에 따른 용접특성 (I) - 실드가스 종류 및 유량에 따른 영향 -)

  • Kim, Jong Do;Kim, Ji Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.12
    • /
    • pp.1047-1053
    • /
    • 2016
  • In this study, welding of pure titanium was carried out by using a continuous wave fiber laser with a maximum output of 6.3 kW. Because brittle regions form easily in titanium as a result of oxidation or nitriding, the weld must be protected from the atmosphere by using an appropriate shielding gas. Experiments were performed by changing the type and the flow rate of shielding gases to obtain the optimal shielding condition, and the weldability was then evaluated. The degree of oxidation and nitriding was distinguished by observing the color of beads, and weld microstructure was observed by using an optical microscope and a scanning electron microscope. The mechanical properties of the weld were examined by measuring hardness. When the weld was oxidized or nitrified, the bead color was gray or yellow, and the oxygen or nitrogen content in the bead surface and overall weld tended to be high, as a result of which the hardness of the weld was thrice that of the base metal. A sound silvery white bead was obtained by using Ar as the shielding gas.