• Title/Summary/Keyword: Laser Ray

Search Result 578, Processing Time 0.028 seconds

Efficient keV X-ray Generation from Irradiation of in-situ Produced Silver Clusters by Ti:sapphire Laser Pulses

  • Chakravarty, U.;Naik, P.A.;Kumbhare, S.R.;Gupta, P.D.
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.1
    • /
    • pp.80-85
    • /
    • 2009
  • An experimental study of energy absorption and x-ray emission from ultrashort laser pulse irradiation of in-situ produced solid clusters has been performed. Silver clusters produced by a 30 mJ, 300 ps laser pulse were irradiated up to an intensity of $3{\times}10^{17}\;W/cm^2$ by a 70 mJ, 45 fs compressed laser pulse from the same Ti:sapphire laser. Absorption of the laser light exceeding 70% was observed, resulting in an x-ray yield (>1 keV) of ${\sim}60{\mu}J$ pulse. This may constitute a much simpler means of intense x-ray generation using ultrashort laser pulses as compared to the irradiation of structured / pre-deposited cluster targets, and it offers higher x-ray conversion efficiency than that from gas clusters and planar solid targets.

LASER-PRODUED PLASMA AS AN X-RAY SOURCE

  • 김효근
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1991.06a
    • /
    • pp.64-64
    • /
    • 1991
  • The interaction of high-intensity, focused, nanosecond laser light with matter results in the production of high-temperature plasma, which in turn emits an intense pulse of x rays. The x-ray spectrum consists of strong line components of several keV photon energy and broad continuum. Such an x-ray source provides many advantages over conventional ones for many applications. Pulse nature of the x-ray emission is well-suited for studying transient phenomena and for imaging living biological specimen. Recent experiments have also shown that the laser plasma x ray may be used for x ray lithography. These studies and other applications will be discussed in detail.

  • PDF

Temperature Characteristic and Writing Quality Improvement of Blu-ray Laser Diode for Optical Disc Recording (광학 디스크 기록을 위한 Blu-ray Laser Diode의 온도특성 및 기록품질 개선)

  • Lee, Do-Han;Kim, Young-Kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.7
    • /
    • pp.1687-1692
    • /
    • 2010
  • In this paper, we research the method for write quality improvement by temperature characteristic of Laser diode for optical recording. Differential Resistance of Blu-ray laser diode is changed by temperature. We analyze the effect of the change of the differential resistance in low temperature and propose the method for the write quality improvement.

A Study of Temperature Characteristic and Recording Quality Improvement of Blu-ray Laser Diode for Optical Media Recording (광학 디스크 기록을 위한 Blu-ray Laser Diode의 온도특성 및 기록품질 개선에 관한 연구)

  • Lee, Do-Han;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.503-505
    • /
    • 2009
  • In this paper, we research the method for write quality improvement by temperature characteristic of Laser diode for optical recording. Differential Resistance of Blu-ray laser diode is changed by temperature. We analyze the effect of the change of the differential resistance and propose the method for the write quality improvement.

  • PDF

High-resolution Spectroscopy of the Nickel-like Molybdenum X-ray Laser Toward the Generation of Circularly Polarized X-ray Laser

  • Hasegawa, Noboru;Sasaki, Akira;Yamatani, Hiroshi;Kishimoto, Maki;Tanaka, Momoko;Ochi, Yoshihiro;Nishikino, Masaharu;Kunieda, Yuichi;Kawachi, Tetsuya;Yoneda, Hitoki;Iwamae, Atsushi
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.1
    • /
    • pp.60-64
    • /
    • 2009
  • We attempted the first measurement of the spectral width of the nickel-like molybdenum x-ray laser (${\lambda}\;=\;18.895\;nm$) by use of a high-resolution spectrometer in order to determine the strength of the magnetic field required for the generation of a circularly polarized x-ray laser. The spectral width was measured to be ${\Delta}{\lambda}\;=\;18\;m{\AA}$ under the substantial lasing condition. The magnetic field required for the generation of a circularly polarized x-ray laser was 40 T. The splitting of the x-ray laser line was clearly obtained under 15 T external magnetic field. The strength of the magnetic field estimated from the splitting of the x-ray laser line was large compared with the external magnetic field. It implies that there might be an alternative mechanism for enhancement of the magnetic field in the gain medium plasma.

A Monochromatic Soft X-ray Generation from Femtosecond Laser-produced Plasma with Aluminum

  • Son, Joon-Gon;Hwang, Byung-Jun;Seo, Okkyun;Kim, Jae Myung;Noh, Do Young;Ko, Do-Kyeong
    • Journal of the Korean Physical Society
    • /
    • v.73 no.12
    • /
    • pp.1834-1839
    • /
    • 2018
  • A tabletop ultrafast soft x-ray has been generated from the laser-produce plasma with a femtosecond pulsed Ti:Sapphire laser. The estimated total flux of Al $K{\alpha}$ is of $2.2{\times}10^9photons/sec$ in $4{\pi}$ radian and the parameters related to the optical performance were obtained. The tungsten/silicon multilayer, flat quartz and bent thallium acid phthalate (TLAP) crystal were used for monochromatization of soft x-ray to refine the aluminum $K{\alpha}$ radiation and compared the respective value of $E/{\Delta}E$. To estimate the size of the x-ray source beam generated by a fs laser, the approximation using the FWHM obtained from the x-ray beam scan near the focal point was discussed, and the size of the diameter was about $9.76{\mu}m$.

Characteristics of Metal Surface Heat Treatment by Diode Laser (다이오드 레이저를 이용한 금속 표면 열처리 특성)

  • Choi, Seong-Dae;Cheong, Seon-Hwan;Kim, Gi-Man;Yang, Seung-Cheol;Kim, Jam-Gyu
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.6 no.3
    • /
    • pp.16-23
    • /
    • 2007
  • An experimental investigation with diode laser system was carried out to study the effect of surface heat treatment on the die materials(SM45C, SKD11, SK3). The surface heat treatment characteristics of the laser beam are evaluated using hardness tests, optical microscopy, X-ray diffraction and energy dispersive X-ray spectroscopy(EDS). Results indicated that the beam size, focal length, feed rates are changed surface hardened characteristics. SM45C is higher hardness than other materials and composed to martensite grain at hardened zone, whereas other materials(SKD11, SK3)are low hardness than expected and composed to austenite and allayed martensite at hardened zone. The intensive X-ray diffraction patterns of (110)-(200)-(211) is detected hardened surface and the hardened surface distributed plenty of carbon density than metal zone.

  • PDF

Conceptual Design of Soft X-ray Microscopy for Live Biological Samples

  • Kim, Kyong-Woo;Nam, Ki-Yong;Kwon, Young-Man;Shim, Seong-Taek;Kim, Kyu-Gyeom;Yoon, Kwon-Ha
    • Journal of the Optical Society of Korea
    • /
    • v.7 no.4
    • /
    • pp.230-233
    • /
    • 2003
  • This study describes the conceptual design of a soft x-ray microscope system based on a laserbased source for biomedical application with high resolution (${\leq}$50nm). The laboratory scale soft x-ray microscope consists of high power laser plasma x-ray source and grazing incidence mirrors with high reflectivity. The laser plasma source used for developing this system employs Q-switched Nd-YAG pulsed laser. The laser beam is focused on a tantalum (Ta) target. The Wolter type I mirror was used as condenser optics for sample illumination and as objective mirror for focusing on a detector. The fabrication of the Wolter type I mirror was direct internal cutting using ultraprecision DTM. A hydrated biological specimen was put between the two silicon wafers, the center of which was $Si_3N_4$ windows of 100㎚ thickness. The main issues in the future development work are to make a stable, reliable and reproducible x-ray microscope system.

X-ray laser development using laser-produced plasmas (레이저-플라즈마를 이용한 X-선 레이저의 연구)

  • 남창희
    • Korean Journal of Optics and Photonics
    • /
    • v.3 no.1
    • /
    • pp.67-72
    • /
    • 1992
  • Since the inception of the idea to develop an X-ray laser in 1960's, a rapid progress to demonstrate soft X-ray lasers in the wavelength region below 300$\AA$ has been made during the last ten years. Among many prospective proposals, the recombination scheme and the collisional exitation scheme have been most successful in achieving a significant gain. An appreciable single-pass amplification was achieved at 182 $\AA$ from CVI ions using the recombination scheme and at 206 and 290$\AA$ from the Se XXV ions using the collisional excitation scheme. The current research on X-ray lasers emphasizes the enhancement of amplification upto saturation and the extension of operating wavelength to shorter wavelengths, especially to the water window region between 23 and 44 $\AA$. X-ray lasers are expected to open many application fields, such as X-ray laser microscopy, X-ray holography, X-ray lithography, and more, in the near future.

  • PDF

Real-time Temporal Characterization and Performance Optimization of a kHz Femtosecond Ti:Sapphire Laser Using a Comprehensive SPIDER

  • Luu, Tran Trung;Park, Ju-Yun;Lee, Jae-Hwan;Nam, Chang-Hee
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.146-151
    • /
    • 2010
  • A comprehensive real-time spectral phase interferometry for direct electric field reconstruction (SPIDER) apparatus for characterizing femtosecond laser pulses is demonstrated. The SPIDER provides the temporal profiles of femtosecond laser pulses, reconstructed at the speed of 3.5 Hz, with parameters of the spectral phase such as group delay dispersion and third-order dispersion. The apparatus is applied successfully to optimize the spectral dispersion of a kHz femtosecond Ti:Sapphire laser by adjusting a grating compressor in real time.