• 제목/요약/키워드: Laser Irradiation

검색결과 624건 처리시간 0.028초

생혈액분석을 통한 저용량 He-Ne 레이저 유침치료에 관한 임상적 연구 (Study on Clinical Effect of Low Level Laser Therapy by Live Blood Analysis)

  • 김성철
    • Journal of Acupuncture Research
    • /
    • 제18권3호
    • /
    • pp.23-34
    • /
    • 2001
  • Objective : The purpose of this study was to investigate the effect of Intravascular Laser Irradiation of Blood(ILIB) by the live blood analysis. Methods : We had analysed the changing forms of the live blood samples with Ultra Darkfield Microscope before and after Intravascular Laser Irradiation of Blood. Results and Conclusion : 1. Nomal Erythrocytes were increased significantly after ILIB by the live blood analysis. 2. Poikilocytes were decreased significantly after ILIB by the live blood analysis. 3. Target Cells were decreased significantly after ILIB by the live blood analysis. 4. Somatid was improved significantly after ILIB by the live blood analysis. 5. Erythrocyte Aggregtion was improved significantly after ILIB by the live blood analysis.

  • PDF

장기간 사용한 Cr-Mo강의 내식성 향상 방법에 관한 연구 (A Study of Corrosion Resistance Improvement for Cr-Mo Steel in Long Term Service)

  • 진영준
    • 한국안전학회지
    • /
    • 제21권3호
    • /
    • pp.8-15
    • /
    • 2006
  • It is no wonder that mechanical structures are accompanied by problems related to corrosion after being exposed to long hours of work. Corrosion of mechanical structures has been the most serious problem in the field of industry. The present study employed a laser beam irradiation test to improve the corrosion resistance of degraded Cr-Mo steel, which was used for more than 60,000 hours. To find the optimum irradiation test condition for the corrosion resistance of degraded Cr-Mo steel, hardness and residual stress measurements, micro-structural observation, and the electrochemical potentiokinetic reactivation (EPR) tests were performed with changes in laser beam test conditions including laser beam output, diameter, and velocity. Thus, the present study indicates that the optimum test condition and absorption energy for a laser beam test need to be determined to enhance corrosion resistance of degraded Cr-Mo steel.

$CO_2$ 레이저의 조사시 치아의 온도변화 (Temperature effect in dental tissue irradiated by $CO_2$ laser)

  • 엄효순;신상훈;박용환;고동섭;김웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.659-661
    • /
    • 1989
  • $CO_2$ laser beam was focused a ZnSe lens onto the center of the occlusal surface of extracted lower molars. K-type thermocouple was contacted with the pulp chamber and the changes of temperature in the pulp chamber during and after the laser irradiation were measured as function of the power of laser beam, the time of laser irradiation and thickness of the sample. An empirical formula for temperature effect was derived from the measured data.

  • PDF

Surface roughness changes in Al2O3 induced by Nd:YAG laser irradiation

  • 여순목;이성준;박재원
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.331-331
    • /
    • 2011
  • We investigated the surface roughness and surface morphology changes for the laser irradiated alumina plates by a Q-switched Nd:YAG laser. For the laser irradiation on the alumina plates with ${\lambda}$ = 1064 nm, the surface roughness decreases with the increasing energy density. The surface morphology shows that the edges of alumina grains become dull with the increasing energy density. For ${\lambda}$ = 532 nm, increasing scan time at the same energy density causes a rough surface. We discuss the physical reason of the surface roughness and surface morphology changes.

  • PDF

초단파 레이저 조사시 티슈 열완화 시간 분석 (Analysis of Thermal Relaxation Time of Tissues Subject to Pulsed Laser Irradiation)

  • 김경한;이제훈;서정
    • 한국레이저가공학회지
    • /
    • 제12권2호
    • /
    • pp.17-25
    • /
    • 2009
  • Two methodologies for predicting thermal relaxation time of tissue subjected to pulsed laser irradiation is introduced by the calculation the optical penetration depth and by the investigation of the temperature diffusion behavior. First approach is that both x-axial and y-axial thermal relaxation times are predicted and they are superposed to achieve the thermal relaxation time (${\tau}_1$) for two-dimensional square tissue model. Another approach to achieve thermal relaxation time (${\tau}_2$) is measuring the time required for local temperature drop until $e^{-1}$ of the maximum laser induced heating.

  • PDF

레이저 어브레이션법에 의해 제조된 산화물 박막의 분위기가스 의존성 (Dependence of ambient gas of oxide films fabricated by laser ablation method)

  • 최충석;이덕출
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제9권4호
    • /
    • pp.357-363
    • /
    • 1996
  • The superconducting properties of YBa$_{2}$Cu$_{3}$$O_{7-x}$(YBaCuO) thin films prepared by laser ablation have been investigated. The x-ray diffraction patterns of the films were substantially different from one another. The Y and Ba oxides are formed by the collisions with oxygen molecules. On the other hand, the Cu oxide is mainly formed at initial stage of the laser irradiation. The YBaCuO films manufactured on MgO(100) substrate were indicated T$_{c}$(zero)=90 K, T$_{c}$(onset)=92 K, and J$_{c}$=3.5*10$^{5}$ A/cm$^{2}$(at 77.3K). The optimum conditions were found to be a substrate temperature of 710.deg. C, an energy density of 2 J/cm$^{2}$, and a target-substrate distance of 60mm in an oxygen partial pressure of 200 mTorr.0 mTorr.

  • PDF

고출력 연속발진 레이저에 의한 금속 관통율 모델링 (Modeling of Metal Penetration Rate by a High Power Continuous Wave Laser)

  • 신완순;고해석;박병서;강응철
    • 한국군사과학기술학회지
    • /
    • 제15권5호
    • /
    • pp.705-711
    • /
    • 2012
  • The purpose of this study is to develop the model to estimate the penetration rate of metal under a high power continuous wave laser irradiation. To estimate it, an empirical modeling is more practical when the penetration phenomena of metal by laser irradiation is too complex to be analyzed by the numerical simulation. When several methods published earlier were applied to our results, we found out that their methods were not appropriate as the model. Therefore, we suggested the new empirical method considering effective intensity as a key variable. As a result, we confirmed that the new method was effective to model the penetration rate of SUS304 metal and expected that it could be available to other metals.

Optical Stimulation and Pacing of the Embryonic Chicken Heart via Thulium Laser Irradiation

  • Chung, Hong;Chung, Euiheon
    • Current Optics and Photonics
    • /
    • 제3권1호
    • /
    • pp.1-7
    • /
    • 2019
  • Optical stimulation provides a promising alternative to electrical stimulation to selectively modulate tissue. However, developing noninvasive techniques to directly stimulate excitable tissue without introducing genetic modifications and minimizing cellular stress remains an ongoing challenge. Infrared (IR) light has been used to achieve optical pacing for electrophysiological studies in embryonic quail and mammalian hearts. Here, we demonstrate optical stimulation and pacing of the embryonic chicken heart using a pulsed infrared thulium laser with a wavelength of 1927 nm. By recording stereomicroscope outputs and quantifying heart rates and movements through video processing, we found that heart rate increases instantly following irradiation with a large spot size and high radiant exposure. Targeting the atrium using a smaller spot size and lower radiant exposure achieved pacing, as the heart rate synchronized with the laser to 2 Hz. This study demonstrates the viability of using the 1927 nm thulium laser for cardiac stimulation and optical pacing, expanding the optical parameters and IR lasers that can be used to modulate cardiac dynamics.

Nd:YAG 레이저를 이용한 철제유물의 표면부식물 제거 및 성분 변화 연구 (Experimental Study of Removing Surface Corrosion Products from Archaeological Iron Objects and Alternating Iron Corrosion Products by Nd:YAG Laser Cleaning System)

  • 이혜연;조남철;이종명;유재은
    • 대한금속재료학회지
    • /
    • 제50권5호
    • /
    • pp.353-360
    • /
    • 2012
  • The corrosion product of archaeological iron objects is supposed to be removed because it causes re-corrosion. So far it is removed by scapel and sand blaster but they depend on the skill and experience of a conservator and the glass-dust of the sand blaster is harmful to humans. Therefore this study applies a laser cleaning system which is used in various industrial cleaning processes, to remove corrosion product from archaeological iron objects. In addition, this work studies the alternation of corrosion product after laser irradiation, which evaluates the reliability of the laser cleaning system. Optical microscopy, SEM-EDS, XRD, Raman have been used to observe and analyse the surface of the objects. The results show the capacity of laser cleaning some corrosion product, but blackening appears with increasing pulses and laser energy, and some corrosion products, goethite and hematite, are partially altered to magnetite. These problems, blackening and alternation of corrosion product, should be solved by further studies which find the optimal laser irradiation condition and use a wetting agent.

Nd : YAG 및 Er : YAG 레이저로 치아표면 조사시 브라켓 전단접착강도에 관한 실험적 연구 (ORTHODONTIC BRACKET SHEAR BOND STRENGTH TO Nd:YAG LASER Er:YAG LASER IRRADIATED ENAMEL)

  • 최승훈;양원식
    • 대한치과교정학회지
    • /
    • 제27권1호
    • /
    • pp.141-155
    • /
    • 1997
  • 교정장치의 직접접착으로 인한 프라켓 주위의 탈석회화 개선 및 산부식시 야기되는 법랑질의 목적 부위 이상으로의 산의 유출방지와 시술시 시간소요 개선을 목적으로 레이저를 조사한 치면의주사전자현미경 소견을 관찰하고 브라켓과 치면 사이의 전단접착강도 및 적합한 조사에너지량을 측정, 평가하기 위하여 실험을 시행하였다. 실험재료로 189개의 소구치를 사용하여 산부식 및 Nd:YAG 레이저로 100mj 10pps, 100mj 20pps, 150mj 20pps, 200mj 20pps를, Er:YAG 레이저로 60mj 5pps, 60mj 10pps, 100mj 10pps, 200mj 10pps, 200mj 15pps, 400mj 10pps를 조사한 각 15개 총 165개의 치 아를 교정용 접착제로 접착한후 24시간, 1주, 3주 후로 나누어 전단 접착강도를 측정하였으며, 나머지 24개의 치아에서 산부식군과 각 레이저 조사군 및 정상치아인 비처치대조군을 주사전자현미경으로 관찰하여 다음과 같은 결과를 얻었다. 1. Nd:YAG 레이저 및 Er:YAG 레이저의 각 조사에너지량에 따른 평균 및 표준편차를 얻었다. 2. 같은 에너지 밀도를 조사한 경우 Er:YAG 레이저 조사군의 전단접착강도가 Nd:YAG 레이저 조사군보다 높았다. 3. Nd:YAG 레이저 조사군에서는 150mj 20pps에서, Er:YAG 레이저 조사군에서는 200mj 15pps에서 가장 높은 전단접착강도를 보였다. 4. 전단접착강도 및 주사전자현미경 관찰 결과 브라켓 접착시 Nd:YAG 레이저 조사군에서는 150mj 20pps, Er:YAG 레이저 조사군에서는 60mj 10pps 조사가 적합하다고 인정되었다.

  • PDF