• 제목/요약/키워드: Laser Induced Damage

검색결과 63건 처리시간 0.032초

Analysis on Design and Fabrication of High-diffraction-efficiency Multilayer Dielectric Gratings

  • Cho, Hyun-Ju;Lee, Kwang-Hyun;Kim, Sang-In;Lee, Jung-Hwan;Kim, Hyun-Tae;Kim, Won-Sik;Kim, Dong Hwan;Lee, Yong-Soo;Kim, Seoyoung;Kim, Tae Young;Hwangbo, Chang Kwon
    • Current Optics and Photonics
    • /
    • 제2권2호
    • /
    • pp.125-133
    • /
    • 2018
  • We report an in-depth analysis of the design and fabrication of multilayer dielectric (MLD) diffraction gratings for spectral beam combining at a wavelength of 1055 nm. The design involves a near-Littrow grating and a modal analysis for high diffraction efficiency. A range of wavelengths, grating periods, and angles of incidence were examined for the near-Littrow grating, for the $0^{th}$ and $-1^{st}$ diffraction orders only. A modal method was then used to investigate the effect of the duty cycle on the effective indices of the grating modes, and the depth of the grating was determined for only the $-1^{st}$-order diffraction. The design parameters of the grating and the matching layer thickness between grating and MLD reflector were refined for high diffraction efficiency, using the finite-difference time-domain (FDTD) method. A high reflector was deposited by electron-beam evaporation, and a grating structure was fabricated by photolithography and reactive-ion etching. The diffraction efficiency and laser-induced damage threshold of the fabricated MLD diffraction gratings were measured, and the diffraction efficiency was compared with the design's value.

토끼의 관절병증에 미치는 SCAN-BIO 레이저의 치료효과 (Effect of scan-bio laser therapy on arthropathy in rabbits)

  • 조형진;김영수;오동민;심경미;강성수;임성철;조용성;이수한;최석화;배춘식
    • 대한수의학회지
    • /
    • 제44권3호
    • /
    • pp.475-482
    • /
    • 2004
  • For the induction of arthropathy, 4% hydrogen peroxide ($H_2O_2$) was injected for 4 weeks into the intra-articular space of the 25 New Zealand white rabbits to damage articular cartilage. The verification of arthropathy induction and the effect of scan-bio laser treatment were determined by measuring superoxide dismutase (SOD) activity, by observing gross and histopathologic findings. The SOD activity increased by about 40% in arthropathy group, as compared to controls. Although SOD activity in arthropathy group was not significantly different from the 2-week group, it was significantly different from the 4-week control and treatment groups. There was also a significant difference between the 4-week control and treatment groups. Grossly, erosions formed on the articular cartilage surface, and the lateral femoral condyle was damaged in arthropathy group. In comparison, there was slight, but not significant, progression of the lesion in the 2-week control group, and no difference between the 2-week treatment and control groups. Conversely, severe erosions damaged the articular cartilage in the 4-week control group. Cartilage proliferation was seen in gross observations in the 4-week treatment group, suggesting a treatment effect. Histopathologically, there was slight articular surface damage and apoptosis in arthropathy group, and serious cartilage damage, despite slight chondrocyte proliferation, in the 4-week control group. By contrast, the 4-week treatment group showed chondrocyte replacement, with close to normal articular cartilage on the articular surface. There was significant cartilage proliferation with regeneration of the articular cartilage on the articular surface in the group treated with low-level laser, as compared to control group, when arthropathy was induced by $H_2O_2$ injections. Therefore, low-level laser was effective in the treatment of chemically induced arthropathy.

빔 중첩율에 따른 티타늄 합금의 펨토초 레이저 어블레이션 (The Femto Second Laser Induced Ablation on the Titanium Alloy for Various Beam Overlap Ratio)

  • 정일영;강경호;김재도
    • 한국정밀공학회지
    • /
    • 제27권11호
    • /
    • pp.17-23
    • /
    • 2010
  • Titanium alloy is one of the hard processing materials made by the traditional manufacturing method because of the excellent mechanical strength. Ablation of titanium alloy is investigated by using a femtosecond laser which is a regenerative amplified Ti:sapphire laser with 1kHz repetition rate, 184fs pulse duration time and 785nm wavelength. Experiments are carried out under various ablation conditions with different pulse overlap ratios for the rectangular shape and micro hole. Test results show that the ablation characteristic according to pulse overlap ratio of titanium alloy seems to be as non-linear type at the different zone of energy fluence. The optimal condition of rectangular shape processing is obtained at the laser peak power 1.3mW, pulse overlap ratio of 90%, beam gap of $1\;{\mu}m$. The micro hole has a good quality from the pulse overlap ratio of 99% at the same laser peak power. With the optimal processing condition, the fine rectangular shape and micro hole without burr and thermal damage are achieved.

$Al_{0.3}Ga_{0.7}As/GaAs$ 다층구조의 레이저 직접 건식에칭 (Laser Direct Ory Etching for $Al_{0.3}Ga_{0.7}As/GaAs$ Multi-layer Structures)

  • 박세기;이천;김성일;김은규;민석기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1980-1981
    • /
    • 1996
  • Laser direct dry etching is a new technique in semiconductor processing which has a lot of advantage, including decrease of etching-induced damage, maskless, photoresistiess, and high selectivity. This study presents characteristics of a laser direct dry etching for $Al_{0.3}Ga_{0.7}As/GaAs$ multi-layer structures for the first time. In this study, we were able to obtain the unusual aching profiles. The cross sectional analysis of etched groove was peformed for reaction characteristics and their applications.

  • PDF

The Effect of Scutellariae Radix on Ischemia Induced Brain Injury in Rats

  • Park, Ji-Eun;Kim, Young-Kyun
    • 대한중풍순환신경학회지
    • /
    • 제10권1호
    • /
    • pp.8-19
    • /
    • 2009
  • Scutellaria Radix, originated from Scutellaria baicalensis Georgi, is one of the most important medicine in traditional Oriental medicine, and possesses anti-bacterial activity and sedative effects, can be applied in the treatment of a range of conditions including diarrhea and hepatitis. It is reported that chronic global ischemia induces neuronal damage in selective, vulnerable regions of the brain, especially the hippocampus and cerebral cortex. In the present study, to investigate the effect of Scutellaria Radix extract on cerebral disease, the changes of regional cerebral blood flow and pial arterial diameter on ischemia/reperfusion state was determinated by Laser-Doppler Flowmetry and some parameters concerned with oxidative stress also measured. When SRe were administered for five days with the concentration of 100 mg/kg, GSH activity significantly increased. But SRe administeration showed no significant change in lipid peroxidation. When the activities of CAT, Cu, Zn-SOD and GSH were measured, CAT and GSH were activated by SRe administration. When 1 and 3 ㎍/㎖ SRe was applied to the neuronal cell cultures, the quantities of LDH was significantly reduced when compared with cultures treated only with NMDA. Through this study, it can be concluded that the ischemia/reperfusion induced brain stress may have contributed to cerebral damage in rats, and the present study provides clear evidence for the beneficial effect of SRe on ischemia induced brain injury.

  • PDF

Development of Bio-ballistic Device for Laser Ablation-induced Drug Delivery

  • Choi, Ji-Hee;Gojani, Ardian B.;Lee, Hyun-Hee;Jeung, In-Seuk;Yoh, Jack J.
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제9권3호
    • /
    • pp.68-71
    • /
    • 2008
  • Transdermal and topical drug delivery with minimal tissue damage has been an area of vigorous research for a number of years. Our research team has initiated the development of an effective method for delivering drug particles across the skin (transdermal) for systemic circulation, and to localized (topical) areas. The device consists of a micro particle acceleration system based on laser ablation that can be integrated with endoscopic surgical techniques. A layer of micro particles is deposited on the surface of a thin metal foil. The rear side of the foil is irradiated with a laser beam, which generates a shockwave that travels through the foil. When the shockwave reaches the end of the foil, it is reflected as an expansion wave and causes instantaneous deformation of the foil in the opposite direction. Due to this sudden deformation, the microparticles are ejected from the foil at very high speeds, and therefore have sufficient momentum to penetrate soft body tissues. We have demonstrated this by successfully delivering cobalt particles $3\;{\mu}m$ in diameter into gelatin models that represent soft tissue with remarkable penetration depth.

MC3T3-E1 osteoblast adhesion to laser induced hydroxyapatite coating on Ti alloy

  • Huang, Lu;Goddard, Samuel C.;Soundarapandian, Santhanakrishnan;Cao, Yu;Dahotre, Narendra B.;He, Wei
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • 제1권2호
    • /
    • pp.81-93
    • /
    • 2014
  • An in vitro cell study evaluating cell adhesion to hydroxyapatite (HA) coated prosthetic Ti-6Al-4V alloy via laser treatment is presented in comparison with uncoated alloy. Based on our previous in vitro biocompatibility study, which demonstrated higher cell attachment and proliferation with MC3T3-E1 preosteoblast cells, the present investigation aims to reveal the effect of laser coating Ti alloy with HA on the adhesion strength of bone-forming cells against centrifugal forces. Remaining cells on different substrates after centrifugation were visualized using fluorescent staining. Semi-quantifications on the numbers of cells were conducted based on fluorescent images, which demonstrated higher numbers of cells retained on HA laser treated substrates post centrifugation. The results indicate potential increase in the normalized maximum force required to displace cells from HA coated surfaces versus uncoated control surface. The possible mechanisms that govern the enhancing effect were discussed, including surface roughness, chemistry, wettability, and protein adsorption. The improvement in cell adhesion through laser treatment with a biomimetic coating could be useful in reducing tissue damage at the prosthetic to bone junction and minimizing the loosening of prosthetics over time.

하드디스크 드라이브에서 슬라이더의 DLC 층 손상에 의한 진동 특성 변화에 관한 연구 (Analysis for flying stability with damaged DLC layer by confined optical energy in TAMR system)

  • 박노철;최종학;임건엽;박경수;박영필
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.984-985
    • /
    • 2014
  • This research investigates to analyze the effect of laser of thermally assisted magnetic recording system on diamond like carbon (DLC) layer of slider. We investigated a damaged DLC layer of slider with laser spot-induced damage and analyze the effect of the damaged DLC layer in slider dynamics. The damaged DLC layer resulted in change of flying height and air bearing stiffness pressure.

  • PDF

실리콘 웨이퍼에서 소수 반송자 재결합 수명과 표면 부위 미세 결함에 의한 기계적 손상 평가 (Estimation of mechanical damage by minority carrier recombination lifetime and near surface micro defect in silicon wafer)

  • 최치영;조상희
    • 한국결정성장학회지
    • /
    • 제9권2호
    • /
    • pp.157-161
    • /
    • 1999
  • 초크랄스키 실리콘 기판의 뒷면에 형성된 기계적 손상이 미치는 효과에 대하여 고찰하였다. 기계적 손상의 정도는 레이저 여기/극초단파 반사 광전도 감쇠법에 의한 소수반송자 재결합 수명, 습식산화/선택적 식각 방법, 표면 부위 미소 결함 및 X-선 단면 측정 분석으로 평가하였다. 그 결과, 웨이퍼 뒷면에 가해지는 기계적 손상의 세기가 강할수 록 소수반송자 재결합 수명은 짧아지고, 표면 부위 미소 결함 밀도는 비례적으로 증가하였으며, 산화 유기 적충 결함 밀 도와도 상호 일치하였다. 그래서, 표면 부위 미소 결함 기술은 산화 유기 적층 결함을 측정하는데 있어서 통상적인 부식 방법과는 별도로 사용될 수 있다.

  • PDF

Beer-Lambert 법칙을 적용한 레이저 열원 프로파일 모델링 및 레이저무기용 반사경의 열변형 해석을 통한 구조-열-광학 성능 연구 (A Study on Structural-Thermal-Optical Performance through Laser Heat Source Profile Modeling Using Beer-Lambert's Law and Thermal Deformation Analysis of the Mirror for Laser Weapon System)

  • 홍대기
    • 항공우주시스템공학회지
    • /
    • 제17권4호
    • /
    • pp.18-27
    • /
    • 2023
  • 본 논문에서는 열해석의 하중조건으로 레이저 열원을 설정하여 반사경의 구조-열-광학 성능 분석을 수행하였다. 레이저 열원 모델은 가우시안 빔을 바탕으로 반투명한 소재를 고려한 Beer-Lambert 법칙을 적용하여 하중조건으로 선정하였으며, 반사경만의 성능 분석을 위하여 기구부는 고려하지 않았다. 열변형해석을 수행하여 반사경 표면의 온도 변화로 인한 열응력과 열변형 데이터를 얻었다. 열변형에 의한 반사경 표면의 변위 데이터를 Zernike 다항식에 피팅하여 파면오차를 계산하였으며, 이를 통해 고에너지 레이저가 반사경으로 입사될 때 반사경의 광학 성능을 예측할 수 있었다.