• 제목/요약/키워드: Laser Energy

검색결과 1,581건 처리시간 0.055초

Nd:YAG레이저조사가 경화상아질에 미치는 영향에 관한 주사전자현미경적 연구 (A Scanning Electron Microscopic Study on the Effect of Nd:YAG Laser Irradiation on the Sclerotic Dentin)

  • 김문현;신금백
    • Journal of Oral Medicine and Pain
    • /
    • 제24권4호
    • /
    • pp.397-410
    • /
    • 1999
  • In order to obtain the basic data concerning the optimal parameters in using Nd:YAG laser as a therapeutic modality to dentinal hypersensitivity, the author prepared 3 sections of sound dentin and 10 sections of sclerotic dentin with thickness of $0.5mm{\pm}0.1mm$ from human extracted teeth of anteriors and premolars, and applied the laser energy from a fiberoptic delivered, free running, pulsed Nd:YAG laser (wavelength 1064nm, pulse duration $120{\mu}sec$, fiber diameter $320{\mu}m$) to surfaces of sound and sclerotic dentin sections for 1 second with contact/unidirectional moving mode of the fiber under speed of 3mm~4mm/sec and parameters of 0.5W/10Hz, 1.0W/10Hz, 1.5W/10Hz, 2.0W/10Hz: $62J/cm^2$, $124J/cm^2$, $187J/cm^2$, $249J/cm^2$. The author comparatively evaluated the characteristics of ultrastructural changes on surfaces of sound and sclerotic dentin sections irradiated by the pulsed Nd:YAG laser using the scanning electron microscopy. A fairly ill-defined bordered surface of partially closed and melted dentinal tubules can be seen on the scanning electron microscopic feature of the sound dentin surface irradiated by the pulsed Nd:YAG laser with energy density of $62J/cm^2$. The physical modification of sound dentin surface extensively occurred depended on the increase of energy density from $62J/cm^2$ to $124J/cm^2$, $187J/cm^2$, $249J/cm^2$. While, a fairly well-defined bordered surface of partially closed and melted dentinal tubules with thickened peritubular dentin can be seen on the scanning electron microscopic feature of the sclerotic dentin surface irradiated by the pulsed Nd:YAG laser with energy density of $62J/cm^2$. The physical modification of sclerotic dentin surface of a fairly rough, shallow depression with many cracks, thickened peritubular dentin and structureless dentinal tubules extensively occurred depended on the increase of energy density from $62J/cm^2$ to $124J/cm^2$, $187J/cm^2$, $249J/cm^2$ compared to those of sound dentin surface irradiated by the pulsed Nd:YAG laser under the same parameters. Therefore, it is recommended that the pulsed Nd:YAG laser as a therapeutic modality to dentinal hypersensitivity should be applied with the less energy density than $62J/cm^2$ on the sound dentin surface, and its energy density on the partially sclerotic dentin surface should be lower than that on the sound dentin surface to preserve tooth from unnecessary excessive structural destruction.

  • PDF

엑시머 레이저를 이용하여 결정화한 PECVD 및 LPCVD 비정질 실리콘 박막의 특성 분석 (Characterization of PECVD and LPCVD a-Si films crystallized by excimer laser)

  • 최홍석;이성규;장근호;전명철;한민구
    • 전자공학회논문지A
    • /
    • 제33A권6호
    • /
    • pp.172-177
    • /
    • 1996
  • We have characterized XeCl excimer-laser-induced crystallization of thin amorphous silicon films deposited by PECVD (${\alpha}$-Si:H) and LPCVD (${\alpha}$-Si). The electrical properties, surface roughness and crystallinity of crystallized thin films have been measured. The dc conductivities, crystallinity andsurface roughness of the films increased as the laser energy density and shot density were increased. The properties of laser annealed films deposited by LPCVD were better than those of thin films deposite by PECVD. We have also found that the multiple shots with relative low energy density were more benifical to the improsvement of surface roughness than the single shot with high energy density preserving the crystallinity.

  • PDF

Surface roughness changes in Al2O3 induced by Nd:YAG laser irradiation

  • 여순목;이성준;박재원
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.331-331
    • /
    • 2011
  • We investigated the surface roughness and surface morphology changes for the laser irradiated alumina plates by a Q-switched Nd:YAG laser. For the laser irradiation on the alumina plates with ${\lambda}$ = 1064 nm, the surface roughness decreases with the increasing energy density. The surface morphology shows that the edges of alumina grains become dull with the increasing energy density. For ${\lambda}$ = 532 nm, increasing scan time at the same energy density causes a rough surface. We discuss the physical reason of the surface roughness and surface morphology changes.

  • PDF

초단파 레이저 조사시 티슈 열완화 시간 분석 (Analysis of Thermal Relaxation Time of Tissues Subject to Pulsed Laser Irradiation)

  • 김경한;이제훈;서정
    • 한국레이저가공학회지
    • /
    • 제12권2호
    • /
    • pp.17-25
    • /
    • 2009
  • Two methodologies for predicting thermal relaxation time of tissue subjected to pulsed laser irradiation is introduced by the calculation the optical penetration depth and by the investigation of the temperature diffusion behavior. First approach is that both x-axial and y-axial thermal relaxation times are predicted and they are superposed to achieve the thermal relaxation time (${\tau}_1$) for two-dimensional square tissue model. Another approach to achieve thermal relaxation time (${\tau}_2$) is measuring the time required for local temperature drop until $e^{-1}$ of the maximum laser induced heating.

  • PDF

Study on A Laser-induced Photoredox Reaction for the Extraction of Precious Elements from Aqueous Solutions

  • Kyuseok Song;Hyungki Cha;Lee, Jongmin;Park, Jongsoo;Lee, Yong-Ill
    • Nuclear Engineering and Technology
    • /
    • 제32권6호
    • /
    • pp.531-536
    • /
    • 2000
  • The extraction of precious metals from aqueous solutions is performed by using a photoredox reaction with a Q-switched Nd:YAG laser. The metallic silver was efficiently precipitated and extracted from the silver nitrate solution by laser photolysis. An optimum reaction condition for silver extraction was determined by adjusting various experimental factors such as type of reducing agent, type of acids and reaction time. The composition of the reaction product was analyzed and it was identified as metallic silver, not other molecular types. The photoreaction of chromium(III) chloride in an acidic aqueous solution was also investigated. The 355 nm laser light was better suited for the reaction of silver nitrate as well as chromium(III) chloride in an acidic solution compared to the 532 nm light.

  • PDF

펄스 Nd:YAG 레이저를 이용한 $\mu$-BGA 기판의 개별칩 분리 연구 (The singulation study of $\mu$-BGA(Ball Grid Array) board using a pulsed Nd:YAG laser)

  • 백광렬;이경철;이천
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.524-527
    • /
    • 2000
  • In this paper, we have studied minimization of the burr which occurred after $\mu$-BGA(ball grid array) singulation process, singulation of the multilayer with a pulsed Nd:YAG(266, 532 nm) laser is used to cut the metal layer which doesn't well absorb laser beam. Especially, the photoresist and $N_2$blowing is effective to minimize of the surface demage and burr. In this experiment, the $N_2$ blowing reduces a laser energy loss by debris and suppress a surface oxidation. The SEM(scanning electron microscopes) and non-contact 3D inspector are used to measure cutting line-width and surface demage. The $\mu$-BGA singulation threshold energy is 75.0 J/cm$^2$at 30 ${\mu}{\textrm}{m}$/s scan speed.

  • PDF

Design of an Nd:YAG Slab Structure for a High-power Zigzag Slab Laser Amplifier Based on a Wavefront Simulation

  • Shin, Jae Sung;Cha, Yong-Ho;Cha, Byung Heon
    • Current Optics and Photonics
    • /
    • 제3권3호
    • /
    • pp.236-242
    • /
    • 2019
  • An Nd:YAG slab structure was designed for a high-power zigzag slab laser amplifier based on computational simulation of the wavefront distortion. For the simulation, the temperature distribution in the slab was calculated at first by thermal analysis. Then, the optical path length (OPL) was obtained by a ray tracing method for the corresponding refractive index variation inside the slab. After that, the OPL distribution of the double-pass amplified beam was calculated by summing the results obtained for the first and second passes. The amount of wavefront distortion was finally obtained as the peak-to-valley value of the OPL distribution. As a result of this study, the length and position of the gain medium were optimized by minimizing the transverse wavefront distortion. Under the optimized conditions, the transverse wavefront distortion of the double-pass amplified beam was less than $0.2{\mu}m$ for pump power of 14 kW.

저용량(低容量) He-Ne 레이저침의 혈락적용(血絡適用) 연구(硏究) (The Study on the Application of He-Ne Laser with Low Energy ILIB to the Superficial Venules)

  • 김성철;조은희;나창수
    • Korean Journal of Acupuncture
    • /
    • 제20권3호
    • /
    • pp.35-47
    • /
    • 2003
  • Objective : The purpose of this study was to investigate the significance of the Oriental medical treatment using He-Ne laser with low energy intravascular Laser Irradiation of Blood(ILIB) through the superficial venules. Methods : The investigation of details connected with the superficial venules in the literature is performed. The investigation of details connected with the pricking blood techniques through the superficial venules in the literature is performed. The classification of the pricking blood techniques through the superficial venules by the blood-letting puncture methods in the literature is performed. The arrangement of domestic clinical treatises on the effectiveness of medical treatment using He-Ne laser with low energy ILIB through the superficial venules is performed. The consideration on the methodology for the improvement of the clinical effectiveness of He-Ne laser with low energy ILIB through superficial venules is performed. Results and Conclusions : The superficial venules are small arteries, veins and capillaries in the superficial region of the human body. In the pricking blood techniques, there are the blood-letting puncture using the implement of acupuncture to the Jing points, Extra points and superficial blood vessels and the acupuncture using the Hirudo. The methods of the blood-letting puncture are classified into the venous blood-letting puncture, the pricking , the picking out white fiber-like substances from the subcutaneous tissue, the cluster needling, the scattered needling, the blood-letting puncture of the tready collateral branch of the large channel and the blood-letting puncture of skin. The He-Ne laser with low energy ILIB through the superficial venules belongs to the Oriental medical treatment as the method of the blood-letting puncture in the vein of cubital fossa. The He-Ne laser with low energy ILIB has an effect on hyperfibrinogenemia, hyperlipidemia, speech and motor dysfunction in the case of cerebral infarction, headache, dizziness, pain and numbness. It is considered that fundamental research on the biological change of the human body, the experimental animal and the unicellular animal, and research on the effectiveness and the safety, and the development of He-Ne laser with low energy ILIB of an effective wavelength range are necessary.

  • PDF

The Application of a Laser to the Chemical Characterization of Radionuclides

  • Park, Y.J.;Park, K.K.;M/Y. Suh;S.K. Yoon;Park, Y.S.;Kim, D.Y.;Kim, W.H.
    • Nuclear Engineering and Technology
    • /
    • 제32권5호
    • /
    • pp.446-456
    • /
    • 2000
  • Laser induced photoacoustic, fluorescence, and photon correlation spectroscopies were applied to the chemical characterization of radionuclides in connection with the radiowaste treatment and disposal. Their measuring principles and systems were briefly described together with their advantages over conventional spectroscopies. Also, other applications of lasers are introduced. Laser induced photoacoustic spectra were measured for a P $r^{3+}$ solution with a very low molar absorptivity. The detection sensitivity was 4.3 $\times$10$^{-5}$ c $m^{1}$ and was 100 times better than that of a UV/VIS spectrophotometer. The Eu(III) excitation spectra($^{7}$ $F_{0}$ longrightarrow $^{5}$ $D_{0}$ transition) were measured for Eu(III)-phthalate complexes using laser fluorescence spectroscopy, showing that only two species, 1:1 and 1:2 complexes, are present in the Eu(III)-phthalic acid system. The size and size distribution for colloidal humic acids and Eu(III)-humate colloids was determined using photon correlation spectroscopy. The presence of Eu(III) enhanced the aggregation of humic acids.s.

  • PDF

Evaluating Laser Beam Parameters for Ground-to-space Propagation through Atmospheric Turbulence at the Geochang SLR Observatory

  • Ji Hyun Pak;Ji Yong Joo;Jun Ho Lee;Ji In Kim;Soo Hyung Cho;Ki Soo Park;Eui Seung Son
    • Current Optics and Photonics
    • /
    • 제8권4호
    • /
    • pp.382-390
    • /
    • 2024
  • Laser propagation through atmospheric disturbances is vital for applications such as laser optical communication, satellite laser ranging (SLR), laser guide stars (LGS) for adaptive optics (AO), and laser energy transmission systems. Beam degradation, including energy loss and pointing errors caused by atmospheric turbulence, requires thorough numerical analysis. This paper investigates the impact of laser beam parameters on ground-to-space laser propagation up to an altitude of 100 km using vertical atmospheric disturbance profiles from the Geochang SLR Observatory in South Korea. The analysis is confined to 100 km since sodium LGS forms at this altitude, and beyond this point, beam propagation can be considered free space due to the absence of optical disturbances. Focusing on a 100-watt class laser, this study examines parameters such as laser wavelengths, beam size (diameter), beam jitter, and beam quality (M2). Findings reveal that jitter, with an influence exceeding 70%, is the most critical parameter for long-exposure radius and pointing error. Conversely, M2, with an influence over 45%, is most significant for short-exposure radius and scintillation.