• 제목/요약/키워드: Large generator

검색결과 630건 처리시간 0.028초

대용량 발전소 재열재생 증기터빈 제어알고리즘에 관한 고찰 (A Study on Turbine Control Algorithms for Large Steam Turbine in a Power Plant)

  • 최인규;정창기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1665-1666
    • /
    • 2008
  • There are three main devices such as boiler producing steam, turbine driving generator and generator producing electricity. An electrical generator in power plant is driven and maintained its speed at rated by steam turbine which is coupled into generator directly. Therefore after the steam turbine reaches its rated speed and the generator gets into parallel operation with power grid, the electrical power can be increased by turbine controller or governor. The first governor was invented by James Watts for the steam engine to be maintained at a constant speed. The first governor by him was mechanical type with fly balls. The electrical type governor was created due to the progress of electronic devices such as operational amplifiers or integrated circuits. and Today digital electronic type of governor is being widely used in most prime movers.

  • PDF

전력망에 연결된 디젤 발전기 세트의 비틀림 진동에 대한 기초 연구 (The Fundamental Study for Torsional Vibration of Diesel Generator Set connected Electric Power Grids)

  • 김효정;윤현우;로날드 디 바로;이돈출
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.294-297
    • /
    • 2014
  • A Shipboard power system consists of three or four diesel generator sets connected to a grid. In case of dual fuel diesel generator sets employed LNG ship as a prime mover, large amounts of electricity are required for electric propulsion, auxiliary machinery and accommodation facilities. The electrical connection between generators through a network, torsional vibration can lead power swings. In this paper, the influence on the network by the torsional vibration of diesel generator sets in grid operation were studied. The torsional vibration characteristics were investigated and analyzed through theoretical analysis and the vibration measurement and the results were presented.

  • PDF

대 전력 후진파 발진기의 설계를 위한 마르크스 발생기의 제작 및 검증 (Fabrication and Identification of Marx Generator for the Design of High Power Backward Wave Oscillator)

  • 김원섭;황낙훈
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권8호
    • /
    • pp.391-399
    • /
    • 1999
  • We have designed the backward wave oscillator, a power-pulsed generator oscillated at 20 GHz has higher frequency than current one. An absolute instability linear analysis was used for the purpose of designing the slow wave structure. A large diameter (D/$\lambda$=4.8) of the slow wave structure was adopted to prevent the breakdown brought about by the increase of power density. We have fabricated a marx generator, pulse forming line and diode. And the development of a compact pulsed power generator with short period and low amplitude is expected.

  • PDF

스타인메츠결선 자기여자 유도발전기의 운전특성 분석 (Analysis of Operating Characteristic of Self Excited Induction Generator with Steinmetz Connection)

  • 강상수;좌종근
    • 전기학회논문지P
    • /
    • 제57권4호
    • /
    • pp.383-387
    • /
    • 2008
  • This paper analyzes the operation characteristics of a self excited induction generator with Steinmetz connection. For this analysis, the symmetrical components analysis is used to obtain the related expressions and the excitation capacitance and the magnetizing reactance are determined in turn by the condition of self excitation which includes the input impedance of the generator as viewed across load terminals. Two simultaneous equations of the condition of self excitation itself are solved by using the real and imaginary function in an application software. This method is applied to simulate the operation characteristics when the generator is driven at rated speed and the specified excitation capacitor is connected across the lagging phase. The results show that better operation characteristics except generated frequency are obtained by using relatively large excitation capacitance and resistive load.

부호율 변경이 가능한 BCH Ecoder의 FPGA구현 (FPGA Implementation of BCH Encoder to change code rate)

  • 제갈동;변건식
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2009년도 춘계학술대회
    • /
    • pp.485-488
    • /
    • 2009
  • 본 논문에서는 블록 채널 부호 계열에서 다중 오류정정 능력을 갖는 BCH Encoder를 FPGA로 구현한 논문이다. 또한 부호율의 변경이 가능하게 하여 다양화 부호 율에 따른 부호를 생성할 수 있게 하였다. 본 논문에서는 FPGA 구현을 위해 Matlab을 이용하여 시뮬레이션을 하였고, 이를 HDL로 설계하고, 동시에 Xilinx사의 System Generator를 사용하여 구현하였고, Timming Analysis와 Resource estimation도 하였다.

  • PDF

Hydrodynamic Design of Thrust Ring Pump for Large Hydro Turbine Generator Units

  • Lai, Xide;Zhang, Xiang;Chen, Xiaoming;Yang, Shifu
    • International Journal of Fluid Machinery and Systems
    • /
    • 제8권1호
    • /
    • pp.46-54
    • /
    • 2015
  • Thrust-ring-pump is a kind of extreme-low specific speed centrifugal pump with special structure as numerous restrictions from thrust bearing and operation conditions of hydro-generator units. Because the oil circulatory and cooling system with thrust-ring-pump has a lot of advantages in maintenance and compactness in structure, it has widely been used in large and medium-sized hydro-generator units. Since the diameter and the speed of the thrust ring is limited by the generator set, the matching relationship between the flow passage inside the thrust ring (equivalent to impeller) and oil bath (equivalent to volute) has great influence on hydrodynamic performance of thrust-ring-pump. On another hand, the head and flow rate are varying with the operation conditions of hydro-generator units and the oil circulatory and cooling system. As so far, the empirical calculation method is employed during the actual engineering design, in order to guarantee the operating performance of the oil circulatory and cooling system with thrust-ring-pump at different conditions, a collaborative hydrodynamic design and optimization is purposed in this paper. Firstly, the head and flow rate at different conditions are decided by 1D flow numerical simulation of the oil circulatory and cooling system. Secondly, the flow passages of thrust-ring-pump are empirically designed under the restrictions of diameter and the speed of the thrust ring according to the head and flow rate from the simulation. Thirdly, the flow passage geometry matching optimization between thrust ring and oil bath is implemented by means of 3D flow simulation and performance prediction. Then, the pumps and the oil circulatory and cooling system are collaborative hydrodynamic optimized with predicted head-flow rate curve and the efficiency-flow rate curve of thrust-ring-pump. The presented methodology has been adopted by DFEM in design process of thrust-ring-pump and it shown can effectively improve the performance of whole system.

Application of HHT for Online Detection of Inter-Area Short Circuits of Rotor Windings of Turbo-Generators Based on the Thermodynamics Modeling Method

  • Wang, Liguo;Wang, Yi;Xu, Dianguo;Fang, Bo;Liu, Qinghe;Zou, Jing
    • Journal of Power Electronics
    • /
    • 제11권5호
    • /
    • pp.759-766
    • /
    • 2011
  • This paper focuses on monitoring and predicting the short circuit faults of the rotor windings of large turbo-generator systems. For the purpose of increasing efficiency and decreasing maintenance cost, a method that combines the HHT (Hilbert Huang Transform) with a wavelet has been studied. This method is based on analyzing a classical Albright detecting coil. Due to the Empirical Mode Decomposition (EMD) and the Intrinsic Mode Functions (IMF) of the HHT the exact location of a short circuit of rotor windings may be given. However, a part of the useful information is eliminated by the unreasonable decomposing scale of the wavelet. Based on the thermodynamics modeling method, this study was illustrated with a 50MW turbo-generator system that is installed in Northern China. The analysis results, which have very good agreement with those of a previous study, show that the method of combining the HHT with a wavelet is an effective way to analyze and predict the short circuit faults of the rotor windings of large generators, such as supercritical turbo-generator systems and wind turbo-generator systems. This work can offer a useful reference for analyzing smart grids by improving the power quality of a distribution network that is supplied by a turbo-generator system.

15 MW급 초전도 풍력 발전기의 설계 및 전자기 해석 (Design and Electromagnetic Analysis of a 15 MW Class Superconducting Wind Power Generator)

  • 정가은;성해진;박민원;유인근
    • 한국산업정보학회논문지
    • /
    • 제24권1호
    • /
    • pp.39-44
    • /
    • 2019
  • 고온 초전도 (HTS) 발전기는 무게, 크기 및 효율의 장점 때문에 활발히 연구되어왔다. 대규모의 초전도 풍력 발전기는 매우 저속의 고토크 회전 기계이다. 이 기계에서는 높은 전자기력과 토크가 중요한 문제이다. 하나의 축에 직렬로 연결된 2개의 발전기는 고토크의 문제를 극복하기위한 하나의 해결 방안이 될 수 있다. 본 논문에서 저자는 15 MW 급 HTS 발전기를 설계하고 분석했다. 3D 유한 요소법을 사용하여 15 MW HTS 발전기의 자기장 분포 및 토크 성능을 확인하였다. 결과적으로 설계된 발전기는 기존의 발전기보다 적은 토크를 생성한다. 제시된 15 MW 초전도 발전기의 설계방식은 대용량 초전도 풍력 발전기의 제작에 있어 고토크로 인한 문제를 해결하는데 활용될 수 있다.

권선단락 유형별 동기발전기의 공극자속 파형 분석 (Analysis on Air-Gap Magnetic Flux of Synchronous Generator According to Short-Circuit Types in Winding)

  • 배덕권;김동훈;박중신;이동영;이성일
    • 전기학회논문지
    • /
    • 제58권5호
    • /
    • pp.929-935
    • /
    • 2009
  • As modem industrialized society progresses, the demand for electric power is increasing rapidly. The electric power system is getting amazingly bigger and complicated, which can easily induce serious troubles from the potential of large fault problems and/or system failure. The monitoring and diagnosis of the electric machine for the fault detection and protection has been important part in the electric power system. Most faults in the generator appear in the winding. This paper presents the air-gap magnetic flux characteristic of a small-scale 2-pole synchronous generator according to the faults in the field winding to protect the generator from the fault. The magnetic flux patterns in air-gap of a generator under various fault conditions as well as a normal state are simulated by using finite element method. These results are successfully applied to the detection and diagnosis of the short-circuit condition in rotor windings of a high capacitor generator.

A Novel SIME Configuration Scheme Correlating Generator Tripping for Transient Stability Assessment

  • Oh, Seung-Chan;Lee, Hwan-Ik;Lee, Yun-Hwan;Lee, Byong-Jun
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권5호
    • /
    • pp.1798-1806
    • /
    • 2018
  • When a contingency occurs in a large transmission route in a power system, it can generate various instabilities that may lead to a power system blackout. In particular, transient instability in a power system needs to be immediately addressed, and preventive measures should be in place prior to fault occurrence. Measures to achieve transient stability include system reinforcement, power generation restriction, and generator tripping. Because the interpretation of transient stability is a time domain simulation, it is difficult to determine the efficacy of proposed countermeasures using only simple simulation results. Therefore, several methods to quantify transient stability have been introduced. Among them, the single machine equivalent (SIME) method based on the equal area criterion (EAC) can quantify the degree of instability by calculating the residual acceleration energy of a generator. However, method for generator tripping effect evaluation does not have been established. In this study, we propose a method to evaluate the effect of generator tripping on transient stability that is based on the SIME method. For this purpose, the measures that reflect generator tripping in the SIME calculation are reviewed. Simulation results obtained by applying the proposed method to the IEEE 39-bus system and KEPCO system are then presented.