• Title/Summary/Keyword: Large generator

Search Result 632, Processing Time 0.029 seconds

Design and Verification of Newly Developed Anti-jamming GPS Test System (새롭게 개발된 항재밍 위성항법장치 점검 시스템 설계 및 검증)

  • Kwon, Byung-Gi;Lee, Jong-Hong;Heo, Yong-Kwan;Lee, Chul
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.12
    • /
    • pp.1-7
    • /
    • 2015
  • These anti-jamming GPS systems are verified using large anechoic chamber or field-test until now. When using a large anechoic chamber, Independent verification from external enviroments like noise is an advantage but high cost and availability of chamber are disadvantages. And in case of field test, verification under real propagation enviroment is an advantage but security problem of military equipments and problem of making same test condition are disadvantages. This paper presents an newly developed anti-jamming GPS test system. This test system mainly consists of small anechoic chamber, jamming divider, jamming signal generator and satellite simulator. The small anechoic chamber is installed many jamming antennas to transmit multi jamming signals and the jamming divider is newly developed to control multi jamming signals. According to self performance test and combined test with Anti-jamming GPS receiver, we verified our system's reliability.

A Study on the Design and Implement of The Function of the Sidelobe Blanking of VHF Radar (초단파 레이다의 부엽 차단 기능에 대한 설계 및 구현에 대한 연구)

  • Kim, Ki-Jung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.4
    • /
    • pp.637-642
    • /
    • 2020
  • In this study, the SLB(Sidelobe Blanking)/BLB(Blacklobe Blanking) design of the VHF band radar using the low-frequency band having a relatively larger beam width than the S-band or X-band radar. The antenna of the VHF band has a relatively large beam width, so it is reflected from the side lobe. If the reflected target signal is not processed into sidelobe, the false alarm rate of the radar increases by recognizing it from the main lobe signal. This method of SLB blocking is the elimination of the side lobe signal in the front of the array antenna using the central radiating element of the array antenna, and the blocking of side lobe signal from the antenna rear through BLB receiver block. After completed the radar implementation, The function of blocking of side lobe signals was confirmed through the system unit test by Simulated signal generator. Through this study, it will be used in the implementation of the side-lobe blocking technology of the array antenna for low-frequency band radar with large antenna size and beam width in the future.

Development of Hybrid AVR for Alternator (교류 발전기용 하이브리드 자동 전압 조정기 개발)

  • Yang, Keun-Ho
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.16 no.4
    • /
    • pp.182-188
    • /
    • 2015
  • An analog AVR has an advantage of short time constant, time to revert again from the abnormal state to a stable one depending on the voltage fluctuations of the load. But the Analog AVR has a disadvantage of large voltage variation according to the load fluctuation. Voltage regulation for digital AVR is very stable, but the time constant is very long compared to that of an analog AVR. Therefore, it indicates that the digital AVR shows unstable output performance in a very large load variations. In this paper, a mixed form of an analog AVR and a digital AVR is proposed. An implemented hybrid AVR has fast time constant and stable voltage regulation capability. Hybrid AVR voltage variations in the load is stable within 1[%] and the voltage stability is also improved. It also showed fast time constant to the level of the analog AVR. Thus hybrid AVR developed in this paper can be used as a power supply for a variety of uses in industry.

Fabrication of K-PHI Zeolite Coated Alumina Hollow Fiber Membrane and Study on Removal Characteristics of Metal Ions in Lignin Wastewater

  • Zhuang, XueLong;Shin, Min Chang;Jeong, Byeong Jun;Lee, Seung Hwan;Park, Jung Hoon
    • Korean Chemical Engineering Research
    • /
    • v.59 no.2
    • /
    • pp.174-179
    • /
    • 2021
  • Recently, hybrid coal research is underway to upgrade low-grade coal. The hybrid coal is made by mixing low-grade coal with bioliquids such as molasses, sugar cane, and lignin. In the case of lignin used here, a large amount of lignin is included in the wastewater of the papermaking process, and thus, research on hybrid coal production using the same is attracting attention. However, since a large amount of metal ions are contained in the lignin wastewater from the papermaking process, substances that corrode the generator are generated during combustion, and the amount of fly ash is increased. To solve this problem, it is essential to remove metal ions in the lignin wastewater. In this study, metal ions were removed by ion exchange with a alumina hollow fiber membrane coated with K-Phillipsite (K-PHI) zeolite. The alumina hollow fiber membrane used as the support was prepared by the nonsolvent induced phase separation (NIPS) method, and K-PHI seeds were prepared by hydrothermal synthesis. The prepared K-PHI seed was seeded on the surface of the support and coated by secondary growth hydrothermal synthesis. The characteristic of prepared coating membrane was analyzed by Scanning Electron Microscope (SEM), X-Ray Diffraction (XRD), Energy Dispersive Spectroscopy (EDX), and the concentration of metal ions before and after ion exchange was measured by Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES). The extraction amount of K+ is 86 mg/kg, and the extraction amount of Na+ is 54.9 mg/kg. Therefore, K-PHI zeolite membrane has the potential to remove potassium and sodium ions from the solution and can be used in acidic lignin wastewater.

Assessment on Plant-Specific PSA for Power Uprates of Westing-House Type Nuclear Power Plants in Korea (국내 WH형원전의 출력증강에 따른 PSA 영향평가)

  • Lee, Keun-Sung;Lim, Hyuk-Soon;Lee, Eun-Chan
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3464-3466
    • /
    • 2007
  • Power uprate is the process of increasing the maximum power level at which a commercial nuclear power plant may operate. Power uprate applications(113 units) for NPPs(Nuclear Power Plants) were recently approved in the United States. Utilities have been using power uprates since the 1970s as a way of increasing the power output of their nuclear plants. To increase the power output of a reactor, typically more highly enriched uranium fuel and/or more fresh fuel is used. This enables the reactor to produce more thermal energy and therefore more steam, driving a turbine generator to produce electricity. In this paper, the propriety of power uprate is explained through the review on the power uprate method and the changes of the physical parameters due to power uprate. The analysis results showed that the CDF(Core Damage Frequency) and LERF(Large Early Release Frequency) are affected in the current probabilistic safety assessment (PSA) model.

  • PDF

Design of a Radix-8/4/2 variable FFT processor for OFDM systems (OFDM 시스템을 위한 radix-8/4/2 가변 FFT 프로세서의 설계)

  • Kim, Young-Jin;Kim, Hyung-Ho;Lee, Hyon-Soo
    • Journal of Digital Convergence
    • /
    • v.11 no.2
    • /
    • pp.287-297
    • /
    • 2013
  • In this paper, we propose an efficient variable-length radix-8/4/2 FFT architecture for OFDM systems. The FFT processor is based on radix-8 FFT algorithm and also supports radix-4 or radix-2 FFT computation. We are using efficient "In-place" memory access method to maintain conflict-free data access and minimize memory size. Also we replace a very large lookup table with a twiddle factor generator which consumes less area then a ROM-based lookup table. The proposed FFT processor performs variable-length FFT including 64, 256, 512, 1024, 2048, 4096 and 8192 points which cover all the required FFT lengths used in 802.11a, 802.16a, DAB, DVB-T, VDSL and ADSL.

Ocean Current Power Parks using Garyuk Draining Sluices of Saemankeum (새만금 가력배수갑문을 이용한 해류발전단지)

  • Jang, Kyungsoo;Lee, Jungeun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.235.1-235.1
    • /
    • 2010
  • Two ocean current power parks are suggested in the front and back of the Garyuk draining sluices of Saemankeum in Korea. They are characterized by installing a plurality of ocean current turbine generators which are arranged in five rows respectively in the land-side ocean current power park behind the Garyuk draining sluices and in the sea-side ocean current power park before the Garyuk draining sluices, generating electricity using the ocean current flowing through the Garyuk draining sluices in the ebbs and tides of Yellow sea. The potential energy of tidal difference of 2.611m at neap in Saemankeum can be converted into the kinetic energy of high speed ocean current via the Garyuk draining sluices which makes it possible to run the ocean current power parks on a large scale. The total facility capacity of two ocean current power parks that consist of 240 ocean current turbine generators with 4m diameter of turbine blades is about 134MW, and the expected total annual power output is about 586GWh.

  • PDF

Generation Efficiency Characteristics of Small Wind Power for Green Energy Utilization (그린에너지 활용을 위한 소형풍력발전기의 효율 특성)

  • Lee, You-Seok;Kim, Jae-Yong
    • Applied Chemistry for Engineering
    • /
    • v.26 no.4
    • /
    • pp.489-494
    • /
    • 2015
  • As the world-wide supply of fossil fuel sources decreases, the need for efficient energy conservation in addition to developing green energy technologies becomes critical. Wind energy is now regarded as one of the most rapidly expanding energy sources in the world. However, due to the high cost for the foundation of large turbines and the high wind speed (over 12 m/s) required, it is very difficult to establish inland wind power plants. In order to solve issues mentioned above, experiments were performed using the small wind power system operated in a low wind speed. In this research, inland wind condition was first analyzed, and 300 W and 1 kW small wind power generators were then installed on a roof and efficiencies of generating electricities were compared.

A Two-stage Stochastic Programming Model for Optimal Reactive Power Dispatch with High Penetration Level of Wind Generation

  • Cui, Wei;Yan, Wei;Lee, Wei-Jen;Zhao, Xia;Ren, Zhouyang;Wang, Cong
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.53-63
    • /
    • 2017
  • The increasing of wind power penetration level presents challenges in classical optimal reactive power dispatch (ORPD) which is usually formulated as a deterministic optimization problem. This paper proposes a two-stage stochastic programming model for ORPD by considering the uncertainties of wind speed and load in a specified time interval. To avoid the excessive operation, the schedule of compensators will be determined in the first-stage while accounting for the costs of adjusting the compensators (CACs). Under uncertainty effects, on-load tap changer (OLTC) and generator in the second-stage will compensate the mismatch caused by the first-stage decision. The objective of the proposed model is to minimize the sum of CACs and the expected energy loss. The stochastic behavior is formulated by three-point estimate method (TPEM) to convert the stochastic programming into equivalent deterministic problem. A hybrid Genetic Algorithm-Interior Point Method is utilized to solve this large-scale mixed-integer nonlinear stochastic problem. Two case studies on IEEE 14-bus and IEEE 118-bus system are provided to illustrate the effectiveness of the proposed method.

A Study on the Out-of-Step Detection Algorithm using Time Variation of Complex Power-Part I : The Variation of Complex Power Trajectory in Complex Plane (복소전력의 변화율을 이용한 동기탈조 검출 알고리즘에 관한 연구-Part I: 복소평면에서의 복소전력의 궤적변화)

  • Kwon O-Sang;Kim Chul-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.7
    • /
    • pp.345-351
    • /
    • 2005
  • An out-of-step condition results from the loss of the synchronism of the generators. A disturbance in a power system causes the generator angle to oscillate. When there is a severe disturbance such as a heavy current fault loss of major generation or loss of a large block of load, the oscillation can be severe and even increase largely and finally the out-of-step condition may un. During the power swing and out-of-step conditions, the apparent impedance at a relay location changes, and the power flow also changes as the angle difference is varied. This paper presents a method to analyze the trajectory of complex power during a power swing and out-of-step condition. The trajectory of the complex power is analyzed when a power swings and a fault occurs. Moreover, the complex power is analyzed when the ratios between the voltages at both sides and the line impedances are changed. These methods are verified through simulation using the ATP/EMTP MODELS.