• Title/Summary/Keyword: Large Capacity storage

검색결과 312건 처리시간 0.042초

Implementation of Hardware RAID and LVM-based Large Volume Storage on Global Data Center System of International GNSS Service

  • Lee, Dae-Kyu;Cho, Sung-Ki;Park, Jong-Uk;Park, Pil-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1553-1557
    • /
    • 2005
  • High performance and reliability of the storage system to handle a very large amount of data has been become very important. Many techniques have been applied on the various application systems to establish very large capacity storage that satisfy the requirement of high I/O speed and physical or logical failure protection. We applied RAID and LVM to construct a storage system for the global data center which needs a very reliable large capacity storage system. The storage system is successfully established and equipped on the latest Linux application server.

  • PDF

가압식 대용량 액체수소 저장탱크의 단열 성능과 BOR (Insulation Performance and BOR of Pressurized Large-capacity Liquid Hydrogen Storage Tank)

  • 서흥석;이영범;김동혁;박창원
    • 한국수소및신에너지학회논문집
    • /
    • 제34권6호
    • /
    • pp.650-656
    • /
    • 2023
  • In order to efficiently control boil-off rate of a liquefied hydrogen tank, the important thing is to maintain an appropriate vacuum level. however, compared to small and medium-sized storage tank, it is very difficult to create and maintain vacuum in large-capacity storage tanks. In this study, we aim to determine the target level of future large-capacity storage tank technology development and secure basic data on performance test methods by analyzing the corelation between evaporation gas and thermal conductivity of liquefied hydrogen storage tanks.

신재생에너지가 연계된 마이크로그리드에서 에너지 저장장치의 최적 용량 선정에 관한 연구 (A Study on Optimal Capacity of Energy Storage System in Renewable Energy Based Micorgrids)

  • 김욱원;이남형;이윤성;신제석;김진오
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.529-533
    • /
    • 2012
  • By introducing RPS(Renewable Portfolio Standard) for reduction of greenhouse gas, Renewable energy sources have becoming widespread gradually. However, Renewable energy sources, such as wind power and PV are difficult to control the output and they have intermittent characteristics of the output. These characteristics would cause some problems when it is connected in the power system. In order to solve these problems, Energy Storage Systems(ESS) are considered to use. Although there are many different storage devices, the utilization of Secondary Battery is the one of the best ways to stabilize an output fluctuation of RES because of its fast responsibility. For that reason, it would better fit a large-capacity of Secondary battery for stabilization. However, batteries cannot be installed with a large capacity blindly because of its expensive cost. So to select proper capacity of the battery is an important consideration. This paper presented a methodology for the optimal capacity and operation of ESS in microgrids.

  • PDF

충진층 현열 축열조의 성태해소에 관한 연구 (A Study on the Performance for the Cylindrical Packed Bed Sensible Heat Storage Unit)

  • 권순석;김시범;구본영
    • 한국해양공학회지
    • /
    • 제4권2호
    • /
    • pp.85-93
    • /
    • 1990
  • A numerical study on the cylindrical packed bed sensible heat storage unit was accomplished by finite difference method. Relation between the heat storage rate and the mechanical pumping energy and the characteristics of the heat storage were investigated for various in let velocities and porosities. In this study, the numerical results are as follows: 1) The temperature distributions of solid and fluid rapidly reached the steady state as the heat capacity ratio was increased. 2) The efficiency of the heat storage was increased as the heat capacity ratio was decreased. For constant heat capacity ratio, however, the efficiency of the heat storage was increased at lower porosity. 3) It is very profitable to design the heat storage system such that the porosity is larger for the large flow rate and samller for small flow rate.

  • PDF

충진층 현열 축열조의 성태해소에 관한 연구 (A Study on the Performance for the Cylindrical Packed Bed Sensible Heat Storage Unit)

  • 권순석;김시범;구본영
    • 한국해양공학회지
    • /
    • 제4권2호
    • /
    • pp.235-235
    • /
    • 1990
  • A numerical study on the cylindrical packed bed sensible heat storage unit was accomplished by finite difference method. Relation between the heat storage rate and the mechanical pumping energy and the characteristics of the heat storage were investigated for various in let velocities and porosities. In this study, the numerical results are as follows: 1) The temperature distributions of solid and fluid rapidly reached the steady state as the heat capacity ratio was increased. 2) The efficiency of the heat storage was increased as the heat capacity ratio was decreased. For constant heat capacity ratio, however, the efficiency of the heat storage was increased at lower porosity. 3) It is very profitable to design the heat storage system such that the porosity is larger for the large flow rate and samller for small flow rate.

겨울철 난방시 탑상형 아파트 구조체의 축·방열 특성에 대한 현장측정 연구 (A Field Measurement Study on Heat Storage/Emission Characteristics of Tower Type Apartment Structures in Winter Season)

  • 장현재;조근제
    • 설비공학논문집
    • /
    • 제24권2호
    • /
    • pp.190-195
    • /
    • 2012
  • In this study, as a complementary study of the former study on indoor thermal environment in a tower type apartment house at tropical nights, a field measurement was conducted in winter season. Mainly, characteristics of heat storage and heat emission in apartment structures, in this study, were investigated. As results, indoor air temperature was changed in the range of $22.5^{\circ}C{\pm}1.0^{\circ}C$, and followed not the change of outdoor air temperature but the changed pattern of floor surface temperature. Wall surface temperature was unresponsive to the change of floor surface temperature compared with the change of indoor air temperature because wall structure was composed of concrete which has large heat capacity, and was changed in the range of $22.3^{\circ}C{\pm}0.6^{\circ}C$. Heat was stored continuously into the structures of wall and ceiling through the measurement term. and this means that a large heat capacity of the apartment structure acts as a disadvantage in winter season, too. As a total review of the study with the former study, a large heat capacity of the apartment structure acts against indoor thermal comfort in winter season as well as in summer season.

Deformation and stress behavior analysis of high concrete dam under the effect of reservoir basin deformation

  • Zheng, Dongjian;Xu, Yanxin;Yang, Meng;Gu, Hao;Su, Huaizhi;Cui, Xinbo;Zhao, Erfeng
    • Computers and Concrete
    • /
    • 제18권6호
    • /
    • pp.1153-1173
    • /
    • 2016
  • According to deformation data measured in some high concrete dams, for dam body deformation, there is a complex relationship with dam height and water head for different projects, instead of a simple monotonic relationship consistently. Meanwhile, settlement data of some large reservoirs exhibit a significant deformation of reservoir basin. As water conservancy project with high concrete dam and large storage capacity increase rapidly these decades, reservoir basin deformation problem has gradually gained engineers' attentions. In this paper, based on conventional analytical method, an improved analytical method for high concrete dam is proposed including the effect of reservoir basin deformation. Though establishing FEM models of two different scales covering reservoir basin and near dam area respectively, influence of reservoir basin on dam body is simulated. Then, forward and inverse analyses of concrete dam are separately conducted with conventional and proposed analytical methods. And the influence of reservoir basin deformation on dam working behavior is evaluated. The results of two typical projects demonstrate that reservoir basin deformation will affect dam deformation and stress to a certain extent. And for project with large and centralized water capacity ahead of dam site, the effect is more significant than those with a slim-type reservoir. As a result, influence of reservoir basin should be taken into consideration with conducting analysis of high concrete dam with large storage capacity.

사용후핵연료 다목적 캐니스터의 운반 및 저장 보조 설비에 대한 예비설계 평가 (Preliminary Design Evaluation of Auxiliary Equipment for Transportation and Storage of Multi-purpose Canister)

  • 신창민;이상환;이연오;정인수;차길용
    • 방사선산업학회지
    • /
    • 제17권3호
    • /
    • pp.309-320
    • /
    • 2023
  • A multi-purpose canister (MPC) was developed for the purpose of transportation, storage and disposal of spent nuclear fuel (SNF) and has the advantage of minimizing repackaging between management stages of SNF. Considering the typical rock characteristics in Korea, a disposal canister is expected to contain 4 assemblies of Pressurized water reactor (PWR) SNF. The capacity of the MPC should be similarly designed with the disposal canister. However, the MPC with four SNF assemblies is expected to be less efficient in transporting and storing compared to a large-capacity canister. Therefore, a preliminary concept was derived for an auxiliary equipment that can transport and store multiple MPCs in a large overpack. A previously derived concept from US was thoroughly reviewed, and the preliminary concept was revised considering domestic situations including crane capacity and others. In addition, the safety of the normal transportation and storage of the MPC placed in transportation and storage overpack was evaluated with the auxiliary equipment.

저장용 초전도 에너지 저장장치의 최적규모 산정을 위한 투자모형 수립에 관한 연구 (A Study on Optimal Size Evaluation Model for Large Scale SMES System)

  • 김정훈;김주락;장승찬;임재윤
    • 전력전자학회논문지
    • /
    • 제4권2호
    • /
    • pp.215-222
    • /
    • 1999
  • 전기에너지의 저장은 발전효율면이나 전력의 품질향상 등 전력시스템에서 뚜렷한 장점을 가지고 있다. 초전도 에너지 저장장치는 전기에너지를 저장할 수 있는 설비의 하나로 높은 효율과 속응성, 긴 수명 등의 특성으로 전력시스템 적용시 곧 이루어지리라 예상된다. 본 논문에서는 SMES의 국내도입시 필요한 투자정보를 제공하기 위한 최적규모 산정의 알고리즘을 제안한다. 제안한 알고리즘은 SMES의 경제적 운전 양상을 결정하는 확률적 운전모형과 최대원리를 이용한 투자계획모형으로 구성되어 있다.

  • PDF

Key parameters of toroidal HTS coil for a superconducting magnetic energy storage system

  • Miyeon, Yoon;Jinwoo, Han;Ji-Kwang, Lee;Kyeongdal, Choi;Jung Tae, Lee;Seungyong, Hahn;Woo-Seok, Kim
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제24권4호
    • /
    • pp.50-54
    • /
    • 2022
  • High temperature superconducting (HTS) magnets for large-capacity energy storage system need to be composed of toroid magnets with high energy density, low leakage magnetic fields, and easy installation. To realize such a large capacity of a toroid HTS magnet, an HTS cable with large current capacity would be preferred because of the limited DC link voltage and instantaneous high power required for compensation of the disturbance in the power grid. In this paper, the optimal operating strategies of the SMES for peak load reduction of the microgrid system were calculated according to the load variation characteristics, and the effect of compensation of the frequency change in microgrid with a SMES were also simulated. Based on the result of the simulation, key design parameters of SMES coil were presented for two cases to define the specification of the HTS cable with large current capacities for winding of HTS toroid coils, which will be need for development of the HTS cable as a future work.