A Study on the Comparison of LANDSAT-5 TM and MSS Data -laying stress on the landuse mapping of Incheon area- (LANDSAT-5의 TM과 MSS 데이타의 비교에 관한 연구 -인천지역의 토지이용분류를 중심으로-)

  • 안철호;박병욱
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.4 no.2
    • /
    • pp.27-41
    • /
    • 1986
  • In this study, practical use of TM (Thematic Mapper) data was evaluated by comparison of LANDSAT- 5 TM and MSS (Multispectral Scanner) data. The comparison of TM and MSS data was achieved by analyzing the result of landuse mapping of Incheon area, and in addition, the comparison of accuracy according to image enhancement method was made. From the results of this study, we found that TM data was more accurate by about 20% than MSS data in landuse mapping, and that smoothing was effective in image enhancement processing of TM data.

  • PDF

The Integration of GIS with LANDSAT TM Data for Ground Water Potential Area Mapping (I) - Extraction of the Ground Water Potential Area using LANDSAT TM Data - (지하수 부존 가능지역 추출을 위한 LANDSAT TM 자료와 GIS의 통합(I) - LANDSAT TM 자료에 의한 지하수 부존 가능지역 추출 -)

  • 지종훈
    • Korean Journal of Remote Sensing
    • /
    • v.7 no.1
    • /
    • pp.29-43
    • /
    • 1991
  • The study was performed to extraction the ground water potential area using LANDSAT TM data. The image processing techniques developed for the study are contrast transformation, differential filtering and pseudo stereoscopic image methods. These were examined for lineament extraction, lineament interpretation and the integration of vertor data with LANDSAT data. The differential filtering method is much usefull for lineament extraction, and all direction lineaments are clearly shown on the band 5 image of LANDSAT TM. The pseudo stereoscopic image are made in which color differential method is adopted, the pair images are usefull for the lineament interpretation. The results of the analysis are as follows. 1) there is a close correlation between lineament and cased well in the study area, because 33 wells of the developed 45 cased wells coincide with the lineaments. 2) 21 sites in the study area were selected for pumping test, and as a result 11 sites of them produces over than 200 ton/day.

Method of Integrating Landsat-5 and Landsat-7 Data to Retrieve Sea Surface Temperature in Coastal Waters on the Basis of Local Empirical Algorithm

  • Xing, Qianguo;Chen, Chu-Qun;Shi, Ping
    • Ocean Science Journal
    • /
    • v.41 no.2
    • /
    • pp.97-104
    • /
    • 2006
  • A useful radiance-converting method was developed to convert the Landsat-7 ETM+thermal-infrared (TIR) band's radiance ($L_{{\lambda},L7/ETM+}$) to that of Landsat-5 TM TIR ($L_{{\lambda},L5/TM+})$ as: $L_{{\lambda},L5/TM}=0.9699{\times}L_{{\lambda},L7/ETM+}+0.1074\;(R^2=1)$. In addition, based on the radiance-converting equation and the linear relation between digital number (DN) and at-satellite radiance, a DN-converting equation can be established to convert DN value of the TIR band between Landsat-5 and Landsat-7. Via this method, it is easy to integrate Landsat-5 and Landsat-7 TIR data to retrieve the sea surface temperature (SST) in coastal waters on the basis of local empirical algorithms in which the radiance or DN of Lansat-5 and 7 TIR band is usually the only input independent variable. The method was employed in a local empirical algorithm in Daya Bay, China, to detect the thermal pollution of cooling water discharge from the Daya Bay nuclear power station (DNPS). This work demonstrates that radiance conversion is an effective approach to integration of Landsat-5 and Landsat-7 data in the process of a SST retrieval which is based on local empirical algorithms.

Monitoring of Rice Growth by RADARSAT and Landsat TM data (RADARSAT과 Landsat TM자료를 이용한 벼 생육모니터링)

  • Hong Suk-Young;Rim Sang-Kyu
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.2 no.1
    • /
    • pp.9-15
    • /
    • 2000
  • The objective of this study is to evaluate the use of RADARSAT and Landsat TM data for the monitoring of rice growth. The relationships between backscatter coefficients($\sigma$$^{0}$ ) of RADARSAT data and digital numbers (DN) of Landsat TM and rice growth parameters were investigated. Radar backscatter coefficients were calculated by calibration process and then compared with rice growth parameters; plant height, leaf area index (LAI), and fresh and dry biomass. When radar backscatter coefficient ($\sigma$$^{0}$ ) of rice was expressed as a function of time, it is shown that the increasing trend ranged from -22--20dB to -9--8dB as growth advances. The temporal variation of backscatter coefficient was significant to interpret rice growth. According to the relationship between leaf area index and backscatter coefficient, backscatter coefficient underestimated leaf area index at the beginning of life history and overestimated, at the reproductive stage. The same increasing trend between biomass and backscatter coefficient was shown. From these results, RADARSAT data appear positive to the monitoring of rice growth. Each band of time-series Landsat TM data had a significant trend as a rice crop grows during its life cycle. Spectral indices, NDVI[(TM4-TM3)/(TM4+TM3)] and RVI(TM4/TM2), derived from Landsat TM equivalent bands had the same trend as leaf area index.

  • PDF

A Correlation Analysis between Land Surface Temperature and NDVI in Kunsan City using Landsat 7 TM/ETM+ Satellite Images (Landsat 7 TM/ETM+ 위성영상을 이용한 군산지역 지표 온도와 NDVI에 대한 상관분석)

  • Lee, Hong-Ro;Kim, Hyung-Moo
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.8 no.2
    • /
    • pp.31-43
    • /
    • 2005
  • Four time points of the fractional area data during the 15 years of the highest group of land surface temperature and the lowest group of NDVl of the Kunsan city Chollabuk_do, Korea located beneath the Yellow sea coast, are observed and analyzed their correlations for the intention to detect the changes of urban land cover. As long as the effective contributions of satellite images in the continuous monitoring of the wide area for wide range of time period, Landsat-5 TM and Landsat-7 ETM+ artificial satellite images, acquisited over the Kunsan city area, are surveyed by the compared calibration after quantization and classification of the deviations between TM and ETM+ images substituted approved error correction thresholds such as gains and biases or offsets. This experiment and research applied Landsat-5 TM and Landsat-7 ETM+ artificial satellite images in change detection of urban land cover in urbanized Kunsan city, then detected strong and proportional correlation relationship between the highest group of land surface temperature and the lowest group of NDVI which exceeded R=(+)0.9478, so the proposed Correlation Analysis Model between the highest group of land surface temperature and the lowest group of NDVI will be able to give proof an effective suitability to the land city change detection monitoring.

  • PDF

An Analysis of the Landuse Classification Accuracy Using IHS Merged Images from IRS-1C PAN Data and Landsat TM Data (IRS-1C PAN 데이터와 Landsat TM 데이터의 IHS중합화상을 이용한 토지이용분류 정확도 분석)

  • 안기원;이효성;서두천;신석효
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.16 no.2
    • /
    • pp.187-194
    • /
    • 1998
  • In this study, effective multispectral Landsat TM band combinations for a merging with the high resolution IRS-1C PAN data using the IHS method to improve landuse accuracy is discussed. From the pre-classified image using the merged images with TM all six band images(with the exception of band 6 image) and PAN image, a sample data which has ten classes was generated. An evaluation of the overall classification accuracy for the representative seven merged images which were merged using each TM three-band images and IRS-1C PAN image by IHS method for the sample area. The increase in classification accuracy is most significant with the inclusion of two of TM4, TM5 and TM7 infrared band images. Especially, the largest increase(11.8 percent) in landuse classification accuracy were investigated when Landsat TM247 bands were merged with IRS-1C PAN data. The classification accuracy when TM three band image and PAN image were used without merging is higher than result of the case of using the merged images.

  • PDF

An Analysis of the Landuse Classification Accuracy Using PCA Merged Images from IRS-1C PAN Data and Landsat TM Data (IRS-1C PAN 데이터와 Landsat TM 데이터의 PCA 중합화상을 이용한 토지이용 분류 정확도 분석)

  • Ahn, Ki-Won;Lee, Hyo-Sung;Seo, Doo-Chun;Shin, Sok-Hyo
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.7 no.1 s.13
    • /
    • pp.87-95
    • /
    • 1999
  • The min object of this study was to prove the effectiveness of PCA(principal component analysis) merged images produced by PCA method using high resolution IRS-1C PAN data and multispectral Landsat TM data A sample data which has ten classes was generated for evaluation of the overall classification accuracy. In result, merged sample image which TM13457 bands with IRS-1C PAN data by PCA method showed best result (95.1%). Especially, the largest improve (6.2%) in classification accuracy was resulted when IRS-1C PAN data was merged with TM123457 or TM13457 images. In addition, landuse classification accuracy of the PCA merged images was improved (5.16%) than original color composite images of Landsat TM data.

  • PDF

The Analysis Errors of Surface Water Temperature Using Landsat TM (Landsat TM을 이용한 표층수온 분석 오차)

  • 정종철;유신재
    • Korean Journal of Remote Sensing
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 1999
  • The estimation technique of surface water temperature by satellite remote sensing has been applied to ocean and large lakes using AVHRR. However, the spatial resolution AVHBR is not abquate for coastal region and small lakes. Landsat 5 TM has 120 m spatial resolution, which suits better. We carried out analysis of surface water temperature in Lake Sihwa and near coastal area using Landsat 5 TM. To relate digital number to the brightness temperature, we applied Empirical, NASA, RESTEC, Quadratic methods. Comparing calculated and observed value, we obtained as follows; NASA method, $R^2=0.9343$, RMSE(Root Mean Square Error)=3.5876$^{\circ}C$; RESTEC method, $R^2=0.8937$, RMSE=3.76$^{\circ}C$; Quadratic method, $R^2=0.8967$, RMSE=2.949$^{\circ}C$. Because Landsat TM has only one band for extracting surface temperature, it was difficult to correct for the atmospheric errors. For improving the accuracy of surface temperature detection using Landsat TM, there is a need for a method to decrease the effect of atmospheric contents.

Estimating the Forest Cover Types on Experimental Forest of Kangwon National University using Landsat-5 TM data (Landsat-5 TM 위성의 영상자료를 이용한 강원대학교 연습림의 임상분석)

  • Woo, Jong-Choon;Kim, Han-Soo;Won, Hyun-Kyu
    • Journal of Forest and Environmental Science
    • /
    • v.15 no.1
    • /
    • pp.65-70
    • /
    • 1999
  • The study analyze Conifer and Hardwood area and their distribution to seek an efficient survey for Experimental Forest of Kangwon National University using Landsat-5 TM data. Through forest cover types, we try to study on the possibility to use Satellite Data. development of Satellite Interpretation Skill and Digital Mapping Method. As analysis tools we use IMAGINE 8.3 and ArcView 3.0 software. The result showed that Hardwood took approximately 73%, 2,224ha of the total 3,058ha and Conifer takes 27%, 832ha.

  • PDF

How is SWIR useful to discrimination and a classification of forest types?

  • Murakami, Takuhiko
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.760-762
    • /
    • 2003
  • This study confirmed the usefulness of short-wavelength infrared (SWIR) in the discrimination and classification of evergreen forest types. A forested area near Hisayama and Sasaguri in Fukuoka Prefecture, Japan, served as the study area. Warm-temperate forest vegetation dominates the study site vegetation. Coniferous plantation forest, natural broad-leaved forest, and bamboo forest were analyzed using LANDSAT5/TM and SPOT4/HRVIR remote sensing data. Samples were extracted for the three forest types, and reflectance factors were compared for each band. Kappa coefficients of various band combinations were also compared by classification accuracy. For the LANDSAT5/TM data observed in April, October, and November, Bands 5 and 7 showed significant differences between bamboo, broad-leaved, and coniferous forests. The same significant difference was not recognized in the visible or near-infrared regions. Classification accuracy, determined by supervised classification, indicated distinct improvements in band combinations with SWIR, as compared to those without SWIR. Similar results were found for both LANDSAT5/TM and SPOT4/HRVIR data. This study identified obvious advantages in using SWIR data in forest-type discrimination and classification.

  • PDF