• Title/Summary/Keyword: Lamp load

Search Result 92, Processing Time 0.02 seconds

A Study on Application of Wavelet Transform to Electrical Load Discriminations (부하 판별을 위한 Wavelet 변환의 응용에 관한 연구)

  • 정종원;김민성;김태홍;이준탁
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2001.05a
    • /
    • pp.109-112
    • /
    • 2001
  • Recently, the subject of \"wavelet analysis\" has drawn much attention from both mathematical and engineering application fields such as Signal Processing, Compression/Decomposition, Statistics and ets. Analogous to Fourier analysis, wavelets is a versatile tool with very rich mathematical content and great potential for applications. Specially, wavelet transform uses localizable various mother wavelet functions in time-frequency domain. In this paper, discrimination analyses of acquired electrical current signals for each and mixed loads were tried by using Morlet wavelet transform. Their representative loads were classified as TV, DRY(Dryer), REF(Refrigerate), and FL(Fluorescent Lamp).

  • PDF

Characterization of LED Lighting according to Voltage Variation (전압변동에 따른 LED 조명의 특성분석)

  • Lee, Dae-Woo;Lee, Jong-Pil;Ji, Pyeong-Shik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.4
    • /
    • pp.271-276
    • /
    • 2014
  • LED lighting has received worldwide attention as advantages, such as environment-friendly than the conventional light, the excellent energy efficiency, and a semi-permanent lifetime. The use of the SMPS increased with the rapid growth in the LED industry. Increased use of SMPS means an increase in the harmonic generation load. Therefore, LED lighting compared with conventional fluorescent lamps were tested in this paper for characterized by a light source, electrical and harmonic characteristics. Experiments results for LED lighting showed different characteristics from the existing fluorescent lamp. Especially harmonic characteristic results showed different characteristics in accordance with the power device manufacturing method for LED lighting.

A Study on the LCD Backlight Drive using Piezoelectric Transformer (압전 변압기를 이용한 LCD Backlight 구동에 관한 연구)

  • 강태구;이동균;유영한;안형근;한득영
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.273-277
    • /
    • 1999
  • A cold cathode flourescent lamp for the backlight in the notebook computer requires high input voltage about 1300(V) when it turns on. But once a discharge starts, the input voltage can be dropped by about one-third for continued output. The equivalent impedance also varies from open to several dozens of kilo-ohms. The piezoelectric transformer converts electrical energy into mechanical energy and then converts it back to electrical energy at a high voltage. Its high output voltage, high efficiency and small size are suitable for driving the LCD backlight in the notebook computer. The piezoelectric transformer operates near the resonance frequency and the output waveform is close to sine wave with very little noise. This paper suggests an inverter for LCD backlight of notebook computer using piezoelectric transformer that includes voltage to frequency converter for gate signal which is useful for tracking of variable resonance frequency depending on load impedance.

  • PDF

Effect of Process Parameters of UV Enhanced Gas Phase Cleaning on the Removal of PMMA (Polymethylmethacrylate) from a Si Substrate

  • Kwon, Sung Ku;Kim, Do Hyun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.4
    • /
    • pp.204-207
    • /
    • 2016
  • Experimental study of UV-irradiated O2/H2 gas phase cleaning for PMMA (Polymethylmethacrylate) removal is carried out in a load-locked reactor equipped with a UV lamp and PBN heater. UV enhanced O2/H2 gas phase cleaning removes polymethylmethacrylate (PMMA) better at lower process pressure with higher content of H2. O2 gas compete for UV (184.9 nm) absorption with PMMA producing O3, O(1D) and lower dissociation of PMMA. In our experimental conditions, etching reaction of PMMA at the substrate temperature between 75℃ and 125℃ had activation energy of about 5.86 kcal/mol indicating etching was controlled by surface reaction. Above the 180℃, PMMA removal was governed by a supply of reaction gas rather than by substrate temperature.

A Study on characteristics of the forward type high frequency pulse power supply for lamp type ozonizer (램프형 오존발생기용 Forward type 고주파 펄스 전원장치의 특성에 관한 연구)

  • 김경식;김동희;이광식;원재선;송현직
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.2
    • /
    • pp.89-96
    • /
    • 2000
  • This paper describes the forward type pulse power supply which is the simple circuit configuration and easy to be managed using a power semiconductor switching device(Power-MOSFET) in the view of commercialization. The maximum value of output pulse voltage of the proposed pulse power supply system can be realized by the variation of phase angle($\phi$) of bridge rectifier circuit and also its pulse period is determined by the duty ratio of Power-MOSFET. The principle of basic operating and the operating characteristics of the forward type pulse power supply are estimated by the switching frequency, the variation of phase angle($\phi$)It is shown that theoretical and experimental results are in good agreement by comparing simulation and experimental results of proposed pulse power supply when a lamp type ozonizer can be used as a load. This proposed pulse power system shows that it can be practically used in the future as a power source system in various fields.

  • PDF

The Characteristics of $\lambda$ Vibration-Mode Type Piezoelectric Transformer ($\lambda$ 진동모드형 압전 변압기의 특성)

  • Jeong, S.H.;Lee, J.S.;Hong, J.K.;Chai, H.I.;Yoon, M.S.;Lim, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.981-983
    • /
    • 1999
  • In this paper, the electrical characteristics of $\lambda$ vibration-mode piezoelectric transformer for applying to CCFL driving inverter was investigated. Piezoelectric transformer was made of PZT - PMN - 0.5wt% $Nb_{2}O_{5}$ composition. As a results of the electrical characteristics of piezoelectric transformer, when applied voltage was $35[V_{rms}]$ in $100[k{\Omega}]$ load resistance, output voltage was about $710[V_{rms}]$ and output power was more than 2[W]. As output power increased, step-up ratio and temperature was very stable until output power was 2.5[W]. Also, Efficiency was maximum in $70[k{\Omega}]$ load resistance, and about 89[%]. Also, when CCFL was used as load, the maintaining voltage was $700[V_{rms}]$ and the luminescence was $2000[cd/m^2]$ in applying $25[V_{rms}]$ to piezoelectric transformer. Conclusively, piezoelectric transformer fabricated in this paper can be applied to piezoelectric inverter for CCFL driving.

  • PDF

Detection Method of Series Arc Signal (직렬아크신호지 검출방법)

  • Kil, Gyung-Suk;Ji, Hong-Keun;Park, Dae-Won;Kim, Il-Kwon;Rhyu, Keel-Soo;Song, Jae-Yong
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.5
    • /
    • pp.477-481
    • /
    • 2008
  • This paper dealt with a detection method of series arc existence which is a symptom of electric fires in low-voltage system. The proposed detection circuit consists of a high-pass filter with a low cut-off frequency of 3kHz to attenuate power frequency voltage by 80 dB and an active band-pass filter with a center frequency of 4kHz to detect only the series arc signals. The performance of the circuit was evaluated in a phase-controlled incandescent lamp as a non-linear load and an inverted-fed induction motor as a high frequency load by using the arc generator specified in UL1699. From the experimental results, it was confirmed that the proposed method solved the detection error, which is being the most problem, by discriminating the series arc signal even in non-linear and high frequency loads.

Investigation of Lateral Resistance of Short Pile by Large-Scale Load Tests (실물 재하시험을 통한 짧은말뚝의 횡방향 저항거동 평가)

  • Lee, Su-Hyung;Choi, Yeong-Tae;Lee, Il-Wha;Yoo, Min-Taek
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.8
    • /
    • pp.5-16
    • /
    • 2017
  • When a lateral load is applied to a short pile whose embedded depth is relatively smaller than its diameter, an overturning failure occurs. To investigate the behavior of laterally loaded short piles, several model tests in laboratory scales had been carried out, however the behavior of large moment carrying piles for electric poles, traffic sign and road lamp, etc. have not been revealed yet. This paper deals with the real-scale load tests for 750 mm diameter short piles. To simulate the actual loading condition, very large moment was mobilized by applying lateral loads to the location 8 m away from the pile head. Three load tests changing the pile embedded lengths to 2.0 m, 2.5 m, and 3.0 m were carried out. The test piles overturned abruptly with very small displacement and rotation before the failures. These brittle failures are in contrast with the ductile failures shown in the former model tests with the relatively smaller moment to lateral load ratio. Comparisons of the test results with three existing methods for the estimation of the ultimate lateral capacity show that the method assuming the rotation point at pile tip matches well when the embedded depth is small, however, as the embedded depth increases the other two methods assuming the inversion of soil pressure with respect to rotation points in pile length match better.

Feasibility Study on Detection of Crack in Bovine Incisor Using Active Thermography (보빈 치아 균열의 적외선 열화상 검사 가능성에 관한 실험적 연구)

  • Kim, Woo-Jae;Yang, Seung-Yong;Kim, No-Hyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.5
    • /
    • pp.508-515
    • /
    • 2011
  • Bovine incisor was investigated using active infrared thermography(IRT) to visualize crack on bovine teeth. An artificial crack was carefully created in bovine incisor sample by compression load of universal tensile machine. While applying a sinusoidal heat wave to the cracked bovine incisor through halogen lamp, consecutive digital infrared images was captured from the sample surface at a frequency synchronized with heat excitation. Phase information of thermal image was calculated by four-point correlation method and processed to produce the phase image of bovine incisor. This phase image showed clearly the crack on the incisor, which was hardly detected in traditional passive thermography.

A Study on the Control Method of Hand & Automatic Operation of On-Off Wiring of an Easy Elevator (간이 엘리베이터 수.자동 개폐배선 제어방식에 관한연구)

  • Wee, Sung-Dong;Gu, Hal-Bon;Kim, Tae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.1107-1112
    • /
    • 2002
  • An easy elevator originated is an opened system to compare an existing equipment, and learning efficient is high as a wiring that the sequence control circuit is on and off. The structure of an equipment to be controled from the first floor to the fifth floor is constructed by a lamp to express the function of the open-close of the door according to the cage moving, to express the mechanical actuation of the forward-reverse break and motor of load and of hand-worked control component of Push-Button S/W, L/S and Relay. In order to act of the elevator function that these components connected, designed the auto program and the sequence control circuit. Consequently the process that these(1~5steps) operated the cage with an auto program of the elevator and the sequence control circuit is controled by the step of forward and reverse that the L/S1~L/S5 of sensor adjust function let posit, by the adjustable S/W1~S/W5 of PLC testing panel and the S/W1~S/W5 which installed on the transparent acryl plate of a frame. In here, improved apparatus is the learning equipment of combined use to study the principle and the technique of the originated sequence control circuit and the auto program of PLC.

  • PDF