• Title/Summary/Keyword: Lamp load

Search Result 92, Processing Time 0.029 seconds

A Study on Railroad Vehicle Lighting Environment (철도차량 조명 환경 연구)

  • Kang, Og-Goo;Jang, Woojin
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.3
    • /
    • pp.178-182
    • /
    • 2014
  • This paper investigates the lighting environment of railway system which are mainly used in KTX, Saemaul and Mugunghwa. When lighting used in KTX such as fluorescent lamp and incandescence is being replaced with LED lamp, illumination load of each railroad vehicle has been compared. The comparison result shows that the reduction of power consumption is 43.34% before and after the change. Also it has been performed the economic evaluation.

High Flux LED Garden Lamp Using PV Generation System (태양광 발전을 이용한 하이 플럭스 LED 정원등)

  • Choi, Guang-Soo;Jung, Doo-Yong;Kim, Jea-Hyung;Won, Chung-Yuen;Kim, Young-Real
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.445-448
    • /
    • 2008
  • There are increased interests in using new regeneration energy due to the effect of the latest rising oil price. On this account, various practical applications using small stand-alone PV generation system are being made. In this paper, with intent to change mercury lamp using for existing garden lamp with high flux LED, we have considered load characteristic using high flux LED modules applied to PV system. It is simulated with PSIM and made experiment set with a 75[W] solar cell module, DC-DC converter, controller and battery.

  • PDF

Integrated High Voltage Trigger and Simmer power supply for Xenon Lamp (제논 램프 구동용 트리거 및 지머 통합 회로)

  • Jia, Ziyi;Cho, Chan-Gi;Song, Seung-Ho;Jeong, Woo-choel;Park, Hyun-Il;Ryoo, Hong-Je
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.51-53
    • /
    • 2018
  • This paper describes the design and implementation of a circuit consisting of a simmer power supply unit and a series trigger unit that can be applicable to xenon lamp driving. An LCC resonant converter based on the continuous conduction mode (CCM) is applied to the simmer circuit and by using the current output control it is possible to maintain the ionization of the lamp which has the negative resistance load characteristic. At the same time, in order to generate a high voltage, a series trigger circuit which has a number of capacitors and diodes is designed. The generated high trigger output voltage could ionize the xenon gas. This paper explains the configuration and features of the integrated circuit system, and verifies the proposed design and stable operation of the xenon lamp. The experimental and simulation results show the not only rationality but also stability of the proposed circuit.

  • PDF

Electrical Characteristics of Piezoelectric Transformer for Driving A 28W Fluorescent Lamp (28W(T5) 형광등 구동용 압전트랜스포머의 전기적 특성)

  • 류주현;황상모;윤광희;김종선;박창엽
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.847-851
    • /
    • 2000
  • In this study, contour-vibration-mode Pb($Ni_{1/2}$,$W_{1/2}$)$O_3$-Pb(Zr,Ti)$O_3$ piezoelectric transformers for driving a 28W(T5) fluorescent lamp were fabricated to the modified filter structure with ring and dot electrodes which has been developed for application in 455kHz AM radios. The piezoelectric transformers were fabricated to the size of $31.5$\times$31.5$\times$2.5$mm^3$ with the variations of ring/dot electrode area ratio. Driving of piezoelectric transformer was carried out with input region for the ring electrode and output region for the dot electrode. The electrical properties and characteristic temperature rises caused by the vibration were measured at various load resistances. A 28 W fluorescent lamp, T5, was successfully driven by the fabricated transformer. The transformer with ring/dot electrode area ratio of 1.83 exhibited the best properties in terms of output power, efficiency and characteristic temperature rise, 30.95 W, 97.57% and8.3$^{\circ}C$ respectively.

  • PDF

A Study on the Efficiency of a High Power Factor LED Driver Circuit (고역률 LED 구동회로의 효율화에 관한 연구)

  • Lee, Dong Won;Kim, Byungcheul
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.8
    • /
    • pp.629-634
    • /
    • 2013
  • The rectified voltage supplied to LED lamp is used in load and then the surplus voltage can be produced in LED lighting. In this case, LED lighting is proposed that can recyclable the excess voltage to supply power to the controller.

Adjustment of Load Regression Coefficients and Demand-Factor for the Peak Load Estimation of Pole-Type Transformers (주상 변압기 최대부하 추정을 위한 부하상관계수 및 수용율 조정)

  • Yun, Sang-Yun;Kim, Jae-Chul;Park, Kyung-Ho;Moon, Jong-Fil;Lee, Jin;Park, Chang-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.2
    • /
    • pp.87-96
    • /
    • 2004
  • This paper summarizes the research results of the load management for pole transformers done in 1997-1998 and 2000-2002. The purpose of the research is to enhance the accuracy of peak load estimation in pole transformers. We concentrated our effort on the acquisition of massive actual load data for modifying the load regression coefficients, which related to the peak load estimation of lamp-use customers, and adjusting the demand-factor coefficients, which used for the peak load prediction of motor-use customers. To enhance the load regression equations, the 264 load data acquisition devices are equipped to the sample pole transformers. For the modification of demand factor coefficients, the peak load currents are measured in each customer and pole transformer for 13 KEPCO (Korea Electric Power Corporation) distribution branch offices. Case studies for 50 sample pole transformers show that the proposed coefficients could reduce estimating error of the peak load for pole transformers, compared with the conventional one.

High Efficiency Alternating Current Driver for Capacitive Loads Using a Current-Balance Transformer

  • Baek, Jong-Bok;Cho, Bo-Hyung;Park, Joung-Hu
    • Journal of Power Electronics
    • /
    • v.11 no.1
    • /
    • pp.97-104
    • /
    • 2011
  • This paper proposes a new alternating current driving method for highly capacitive loads such as plasma display panels or piezoelectric actuators, etc. In the proposed scheme, a current balance transformer, which has two windings with the same turn-ratio, provides not only a resonance inductance for energy recovery but also a current balance among all of the switching devices of the driver for current stress reduction. The smaller conduction loss than conventional circuits occurs due to the dual conduction paths which are parallel each other in the current balance transformer. Also, the leakage inductances of the transformer are utilized as resonant inductors for energy recovery by the series resonance to the capacitive load. Furthermore, the resonance contributes to the small switching losses of the switching devices by soft-switching operation. To confirm the validity of the proposed circuit, prototype hardware with a 12-inch mercury-free flat fluorescent lamp is implemented. The experimental results are compared with a conventional energy-recovery circuit from the perspective of luminance performances.

Power supply design and discharge characteristics analysis of xenon flashlamp by using LLC resonance rhenomena (LLC 공진현상을 이용한 제논 플래쉬램프 전원회로의 설계 및 방전특성분석)

  • Lee, Hee-Chang
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.3
    • /
    • pp.312-317
    • /
    • 2014
  • In this paper, I propose the design technology of LLC resonant converter for the xenon flashlamp that is used to the solid state laser. Through the fabrication of 1.5kW large scale LLC resonant converter, the discharge characteristics are carried out, and introduce the new control method for limiting inrush current by the abrupt load current changes. The mathematical modeling for the lamp discharge includes the internal loss and lamp parameters. I propose the optimal method for the driving conditions of xenon flashlamp from the simulation results comparing the real measurements.

Load Pattern Considerations of The Photovoltaic Lighting System by Using Computer-based Date Acquisition System (컴퓨터기반의 DAS를 적용한 태양광 조명설비의 운용패턴 고찰)

  • 황명근;허창수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.3
    • /
    • pp.1-10
    • /
    • 2003
  • Comparing to the conventional power systems, PV(photovoltaic) outdoor lighting system applications are evaluated as the most economical application. In this paper, we installed two PV lighting systems, which uses LPS(low pressure sodium) and electrodeless lame as their loads, and applied a computer-based data acquisition system using the Labview program for monitering purpose and effective operations, considering battery life time Also, we observed the generated power from the solar array, and energy losses comparing to its installed capacity. Because most PV system performance procedures have looked at the performance of the individual components and have deficiency of addressing how the integrated system works, we confirmed the decrease possibility of the solar amy capacity after analyzing the performance of the installed PV lighting systems.

Pulse Density Modulated Zero Voltage Soft-Switching High-Frequency Inverter with Single Switch for Xenon Gas Dielectric Barrier Discharge Lamp Dimming

  • Sugimura, Hisayuki;Suh, Ki-Young;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.391-394
    • /
    • 2006
  • This paper presents soft switching zero voltage switching high frequency inverter for rare gas fluorescent lamp using dielectric-barrier discharge phenomenon. The simple high-frequency inverter can completely achieve stable zero voltage soft switching (ZVS) commutation for wide its output power regulation ranges and load variations under its constant high frequency pulse density modulation (PDM) scheme. Its transient and steady state operating principle is originally described and discussed for a constant high-frequency PDM control strategy under a stable ZVS operation commutation, together with its output effective power regulation characteristics-based on the high frequency PDM strategy. The experimental operating performances of this high frequency Inverter are illustrated as compared with computer simulation results and experimental ones. Its light dimming characteristics due to power regulation scheme are evaluated and discussed on the basis of simulation and experimental results. The feasible effectiveness of this high frequency inverter appliance implemented here is proven from the practical point of view.

  • PDF